Zephyr WHIRLWIND AK9800 User Manual

Loading...

Use, Care and Installation Guide

Read all Instructions before Installing and operating this appliance

Important Safety Notice

MODEL: AK2000,AK6000,AK9800

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.

WARNING

TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.

b.Before servicing or cleaning unit, switch power off at service panel and lock panel

to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning agents or detergents.

Suitable for use in household cooking area.

WARNING

TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:

a.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b.Always turn hood ON when cooking at high heat or when flaming food

c.Clean ventilating fans frequently. Grease should not be allowed to accumulate

on fan or filter.

d. Use proper pan size. Always use cookware appropriate for the size of the surface element.

e. Keep fan, filters and grease laden surfaces clean. f. Use high setting on hood only when necessary. g. Don’t leave hood unattended when cooking.

h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:

a.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

b.NEVER PICK UP A FLAMING PAN – You may be burned.

c.DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.

Rev:0605

www.zephyronline.com

Important Safety Notice

Read and save these instructions

MODEL: AK2000,AK6000,AK9800

d.Use an extinguisher ONLY if:

1.You know you have a Class ABC extinguisher, and you already know how to operate it.

2.The fire is small and contained in the area where it started.

3.The fire department is being called.

4.You can fight the fire with your back to an exit

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.Installation work and electrical wiring must be done by qualified person (s) in accordance with all applicable codes and standards. Including fire-rated construction.

b.Sufficient air is needed for power combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

c.When cuttig or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

d.Ducted fans must always vent to the outdoors.

e.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCL (Ground Fault Interrupter protected branch circuit).

g.NEVER place a switch where it can be reached from a tub or shower.

h.Make sure the power is off before installing, wiring or maintenancing.

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

CAUTION

To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.

WARNING

TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL CONTROL/SWITCH.

OPERATION

Always leave safety grills and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.

*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.

1

PRODUCT OVERVIEW

HURRICANE SERIES

Model number: AK2000, 2036

, QuattroVent Air Curtain

, Dual “Thrust-Fore" Self Clean Blowers

, Digital Touch Pad Controls

, Clock, Timer, 3 stage Delay Shutoff.

CYCLONE SERIES

Model number: AK6000, 6036, 6042, 6048

, Dual “Thrust-Fore" Self Clean Blowers

, Independent Rocker Controls w/ High, Low speed

, 3 Way convertible ducting option

WHIRLWIND SERIES

Model number: AK9800

, Dual Self Clean Blowers

, Independent Rocker Controls w/ High, Low speed

, Slim Line Design

Overview

3

1.

QuattroVent Air Curtain

1

 

(Hurricane only)

 

2.Self Clean Blowers

3.

Controls

4

4.Light

5.

Residue Cup

2

 

 

6

6.

Underside splash guard

5

CONTROLS

2

HURRICANE SERIES

 

 

3

14

13 12 11 10

 

2

 

 

 

 

hr

 

HI LO

HI LO

1

12:01

4

DELAY

 

 

 

 

min

5

FAN-L

FAN-R ON-OFF

 

 

OFF

 

 

 

 

 

6 7 8 9

Controls Overview

1.Set Time

2.Digital Display

3.Set Hours

4.Set Minutes

5.Set Timed Delay Shut Off

6.Light On-Off

7.Left Blower: On-High-Low-Off

8.Right Blower: On-High-Low-Off

9.Operations: On-Off

10.Right Blower Low Speed Indicator

11.Right Blower High Speed Indicator

12.Left Blower Low Speed Indicator

13.Left Blower High Speed Indicator

14.Delay Off Indicator

Setting Clock

press:

hr

HI LO HI LO

Press "clock".

Hour Indicator will flash indicating clock setting function is ready.

Press "hr" to set hours (from 1-12). Press "min" to set minutes (from 00-59).

Let clock flash for 7 seconds and your new time input will automatically be stored.

Light On-Off

hr

min

12:01

min

DELAY

FAN-L FAN-R

ON-OFF

 

 

OFF

12:01

hr

 

HI LO HI LO

 

min

DELAY

FAN-L FAN-R

ON-OFF

 

 

OFF

press:

Press "light" button once to turn light on. Press again to turn off.

to turn light On/Off

3

CONTROLS

Blower Controls

You can simultaneously turn On the light and both blowers on Hi speed by simply pressing "On/Off" once.

During this time, you can select blowers and speed as indicated by pressing the "Fan-L" and "Fan-R" button.

press:

ON-OFF

FAN-L FAN-R

to turn light and both blowers on Hi

or turn individual blowers On/Off and select Hi/Lo speed

Note:

press again to turn all

ON-OFF operations Off

The third press on the "Fan-L" and "Fan-R"

 

button will turn blower Off the selected side (as

 

indicator light turns off).

 

You can also turn individual blowers On/Off

 

and select speed by simply pressing the

 

desired "Fan-L" or "Fan-R" button.

 

Press "On/Off" again and all operations will stop.

Timed Delay Off

While blowers are in operation, pressing

"Delay Off" button once will set the unit to

press:

DELAY

turn off in 3 minutes. Press again for the

preset 5 minutes countdown and third

OFF

press for 10 minutes.

 

oncecountdown in 3 minutes twicein 5 minutes

3rd timein 10 minutes

Light will turn off when pressed and blowers will decelerate to Lo speed.

Once a desired time is selected,

countdown will start as the delay off indicator: indicator light flashes. All operation will

cease as the countdown reaches zero.

hr

Note: At any time when the delay function is selected, the light will turn off automatically and all blower will decelerate to Lo speed.

3

min

DELAY

OFF

CONTROLS

4

Setting Timer (Alarm)

Press "hr" and "min" button to set desired timer countdown.

Once timer is set, countdown will start in 7 seconds as delay indicator light flashes.

When countdown reaches 0, 10 short beeps will sound.

To cancel timer after setting, press "On/Off" button to terminate all operations and restart.

Note: Timer function cannot be operated simultaneously with the "Delay Off" function. Nevertheless, setting the timer function will not effect any other operations.

press:

hr

min

hr

1:04

min

DELAY

OFF

set "hr" & "min" for timer countdown alarm will sound at end of timer

CYCLONE & WHIRLWIND

Rocker Controls

(1)Lightturns light On/Off

(2)(3) Blower ControlsIndependently controls Right and Left blowers. Rock switch up (I) for Lo speed, (II) for Hi speed, and center (.) to turn off.

(1)Light On/Off

(2)Right Blower (Hi/Lo, Off)

(3)Left Blower (Hi/Lo, Off)

3

2

1

L

R

 

5

MAINTENANCE

Self Clean Feature

All Zephyr Range Hoods are filter-less and are designed with a self clean feature. The centrifugal blower system automatically liquefies grease accumulated in its internal housing. All systems are equipped with dishwasher safe grease containers for its self clean function.

Grease and residue from cooking are often automatically liquefied and can accumulate in the containers from everyday use. Nevertheless, grease from cooking could also dry and adhered in its internal housing. Running the self clean function periodically will flush out the accumulated grease in the range hood’s internal housing.

Cleaning Frequency

Cleaning should be approximately once a month under normal use.

Detergent

Grease cutting detergent such as ‘409’ or its equivalent are recommended.

Cleaning

Safety Grill

Remove both safety grills for cleaning by simply loosening Philips screws. Clean safety grills in dishwasher under normal wash cycle.

WARNING: Use with extreme caution as both safety grills are removed. Beware of blowers catching on to hair, loose clothing, and fingers. NEVER leave children unattended.

Self Clean

Turn both blowers on Low speed for cleaning.

For Hurricane series, simply set Timed Delay Off to 5 minutes as indicated.

press:

twicecountdown in 5 DELAY minutes

OFF

indicator:

hr

5

min

DELAY

OFF