Robert Brunner’s bold re-imagining of a classic island range-hood form is a streamlined fusion of black or white glass and stainless steel. A slim profile and a quartet of halogens enhance the floating effect to lend new meaning to leading edge. Optional duct cover extensions can accommodate contemporary loft-style kitchens with ceilings of up to 12 feet.
ALL-M90ABX
A L L -M 9 0 AW X
ALL-E42ABX
ALL-E42AW X
SIZE
36”
36”
42”
42”
35 7/16”
35 7/16”
42”
42”
COLOR NET WIDTH
Stainless Steel/Black Gl ass
Stainless Steel/ White Glass
Stainless Steel/Black Gl ass
Stainless Steel/ White Glass
ARC COLLECTION
Top
(blower housing and ceiling bracket)
elec. k/o
ext. blower connection
C
L
“8
6”
9 1/4”
5/8”
6 11/16”
7 1/2”
Front
min. ducted - 30” min. recirc. - 30" max. - 34"
blower housing
12 15/16”
27 9/16”
35 7/16” or 42”
12 3/8”
3 1/2”
Side
11 3/16”
16 9/16”
26”
L AYE RS
ISLAND
MODEL
ALL-M90ABX
A L L-M 9 0 AW X
ALL-E42ABX
AL L-E4 2 AW X
FE ATURES
CleanAir Function
Tri-Level Lighting
Duct Cover Extension
*PERFORMANCE
Internal Blower - CBI-290A
Internal Blower - CBI-600A
In-Line Blower - PBN-1000A
External Blower - CBE-1000
MOUNTING HEIGHTS
Height from the cooking sur face
Controls
Speed Levels
Auto Delay-Off
Remote Control
Lighting
Filters
Recirculating
AC INPUT
**AC POWER
Hood Only
36” 36” 42” 42”
Memor y Touch Glass 3 Yes Yes Yes, RF Halogen, 20W x 4 Yes Decorative Mesh x 2 Yes Yes
290 CFM, 3.2 Sones Max. 600 CFM, 6 Sones Max. 1000 CFM, Sones NA 1000 CFM, Sones NA
120V - 60Hz
Max. 80W, 0.66 Amps
Min. 24”–Max. 36”
HOOD HEIGHTS
Standard
Minimum Ducted
Minimum Recirculating
Maximum
Short Kit - Z1C-00LL
Minimum Ducted
Minimum Recirculating
Maximum
Long Kit - Z1C -01LL
Minimum Ducted
Minimum Recirculating
Maximum
DUCT SPECIFICATIONS
Vertical - In-Line/External
OPTIONAL ACCESSORIES
Duct Cover Extension Kit, Short
Duct Cover Extension Kit, Long
* Requires purchase of Zephy r blower, sold separa tely. **AC power listed above is for hood with li ghts only. See blower specs on our web site for more A C power deta ils. ***10” round duct connects to exter nal and in-l ine blower. Mus t transition from 10 ” to 8” before duct pass es through c eiling. A 10” to 8 ” adapter is i ncluded wi th the exter nal and in-line blo wers.
Vertical - Internal
Horizontal
Recirculating Kit
(8 1/2’–9 1/2’ ceiling)
(9 1/2’–12’ ceiling)
30” 30” 34”
37 1/2” 37 1/2” 49”
53 1/2” 53 1/2” 79”