Zephyr AK9428BS, AK9434BS, AK9440BS, AK9446BS Use, Care, and Installation Guide

WWW.ZEPHYRONLINE.COM
Monsoon Connect
AK9428BS, AK9434BS, AK9440BS, AK9446BS EN Use, Care, and Installation Guide
DEC20.0201
C
Air flow Control Technology
TM
CORE
MONSOON
CONNECT
INSERT
2
Monsoon Connect Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information ............................................................................ 4-6
Types of Safety Warnings ................................................................... 4
General Safety ..................................................................................4-5
Operation ........................................................................................... 6
Electrical Requirements ...................................................................... 6
Federal Communication Commission Interface Statement ................. 6
List of Materials ................................................................................... 7
Installation Instructions .................................................................... 8-22
Ducting Calculation Sheet .................................................................. 8
Mounting Height, Clearance, & Ducting ...........................................9-10
Ducting Options ................................................................................. 11
Hood Specifications ............................................................................12
Electrical Supply .................................................................................13
Cable Lock .........................................................................................13
Preparation & Installation ................................................................ 14-16
Horizontal Ducting Preparation ........................................................17-19
PBD-1300B Dual Blower Installation .................................................20-22
Features & Controls ......................................................................... 23-29
Proximity Controls ...........................................................................23-25
Zephyr Connect ..............................................................................26-27
Optional RF Remote Control ............................................................28-29
Maintenance ................................................................................... 30-32
Hood & Filter Cleaning .....................................................................30-31
LumiLight LED ................................................................................... 32
ACT™ Conversion ............................................................................ 33-35
Airflow Control Technology (ACT™) ................................................... 33
Enabling ACT™ ................................................................................34-35
Wiring Diagram ............................................................................... 36-37
Troubleshooting............................................................................... 38-40
List of Parts & Accessories .................................................................. 41
Notes ..................................................................................................42
Limited Warranty ...............................................................................43
Product Registration ...........................................................................44
Contents
Page
Monsoon Connect Use, Care, and Installation Guide
3
CORE
Safety Information
READ AND SAVE THESE INSTRUCTIONS
Your safety and the safety of others are very important.
We have provided many important safety messages in this
manual for your appliance. Always read and obey all safety
messages.
This is the Safety Alert Symbol. This symbol alerts you to
potential hazards that can cause severe bodily injury or death.
All safety messages will follow the Safety Alert Symbol and either
the words “DANGER” “WARNING” or “CAUTION”
DANGER
Danger means that failure to heed this safety statement may
result in severe injury or death.
WARNING
MONSOON
CONNECT
INSERT
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power o at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
Warning means that failure to heed this safety statement may result in extensive product damage, serious personal
injury, or death.
CAUTION
Caution means that failure to heed this safety statement
may result in minor or moderate personal injury, property or
equipment damage.
General Safety
WARNING
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state control device.
WARNING
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
4
Monsoon Connect Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn o the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned. c) DO NOT USE WATER, including wet dishcloths or towels – a
violent steam explosion will result. d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors. e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within walls, ceilings, attics,
crawl spaces, or garages.
WARNING
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
Monsoon Connect Use, Care, and Installation Guide
5
CORE
Safety Information
MONSOON
CONNECT
INSERT
READ AND SAVE THESE INSTRUCTIONS
Operation
Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and
loose clothing.
Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
Ź Observe all governing codes and ordinances. Ź It is the customer’s responsibility to be aware of these below: Ź To contact a qualified electrical installer. Ź To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest
edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path
is adequate.
Ź Do not ground to a gas pipe. Ź Check with a qualified electrician if you are not sure the range hood is properly grounded. Ź Do not have a fuse in the neutral or ground circuit. Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected
by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram
on product.
Ź A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and
install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
Federal Communication Commission Interface Statement
Ź This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Ź This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one of the following
measures:
Ź Reorient or relocate the receiving antenna.
Ź Increase the separation between the equipment and receiver.
Ź Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Ź Consult the dealer or an experienced radio/TV technician for help.
6
Monsoon Connect Use, Care, and Installation Guide
ZEPHYRONLINE.COM
List of Materials
Parts Supplied
Quantity Part
1 Insert hood body 2 Bae filters 3 Bae filters (AK9446BS only) 2 LumiLight LED, 6W (pre-installed) 4 LumiLight LED, 6W (pre-installed) (AK9446BS only)
1 Single blower motor (pre-installed)
1 8” round adapter with damper 2 Horizontal ducting blower mount brackets
1 Top rectangular cover plate
1 Hardware package
#8 x 1/2” (12)
3/16” x 3/8” (10)
Wire Caps (3)
M4 x 6mm (8)
Parts Not Supplied
Ducting, conduit and all installation tools Cable locking connector (if required by local codes) RF remote control Dual blower motor
Monsoon Connect Use, Care, and Installation Guide
7
CORE
Installation Instructions
Ducting Calculation Sheet
Duct pieces
3- 1/ 4” x 10” Rect., straight
6”, 7”, 8”, 10” Round, straight
3- 1/ 4” x 10” Rect. 90 elbow
3- 1/ 4” x 10” Rect. 45 elbow
3- 1/ 4” x 10” Rect. 90 flat elbow
7” to 6” or 8” to 7” Round tapered reducer
6”, 7“, 8” Round in-line damper
6”, 7”, 8”, 10” Round,
0
90
elbow
6”, 7”, 8”, 10” Round,
0
45
elbow
Equivalent number length x used =
1 Ft. x ( ) =
1 Ft. x ( ) =
15 Ft. x ( ) =
0
9 Ft. x ( ) =
0
24 Ft. x ( ) =
0
25 Ft. x ( ) =
15
Ft. x ( ) =
15 Ft.
9 Ft. x ( ) =
Subtotal column 1 =
x ( ) =
To t a l
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Duct pieces
3- 1/ 4” x 10” Rect. to 6” round transition
3- 1/ 4” x 10” Rect. to 6” round transition
0
elbow
90
6” round to 3- 1/ 4” x 10” rect. transition
6” round to 3- 1/ 4” x 10” rect. transition
0
90
elbow
7” round to 3 1/ 4” x 10” rect. transition
7” round to 3- 1/ 4” x 10” rect. transition
0
elbow
90
3- 1/ 4” x 10” Rect. wall cap with damper
6”, 7”, 8”, 10” Round, wall cap with damper
6”, 7”, 8”, 10” Round roof cap
Equivalent number length x used =
5 Ft. x ( ) =
20 Ft. x ( ) =
1 Ft. x ( ) =
16 Ft. x ( ) =
8 Ft. x ( ) =
23 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
MONSOON
CONNECT
INSERT
To t a l
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
8
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 150 equivalent feet.
Monsoon Connect Use, Care, and Installation Guide
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Ft.
Ft.
Ft.
Installation Instructions
ZEPHYRONLINE.COM
Mounting Height, Clearance, & Ducting
24” min. 34” max.
36”
Monsoon Connect Use, Care, and Installation Guide
9
CORE
Installation Instructions
MONSOON
CONNECT
INSERT
Mounting Height, Clearance, & Ducting
A minimum of 8” round or 10” round duct for vertical ducting must be used to maintain maximum air flow eciency. A 8” round duct may be used for horizontal ducting.
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Also use calculation (on page 11) to compute total available duct run when using elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size.
If turns or transitions are required; install as far away from hood duct output and as far apart, between the two as possible.
Minimum mount height between range top to hood bottom should be no less than 24”.
Maximum mount height should be no higher than 34”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its performance and eciency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood mounting height above range.
For shipment and installation damages:
Ź Please fully inspect unit for damage before installation.
Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.
10
Monsoon Connect Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
Ducting Options
WARNING
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
Ź Use single wall rigid metal ductwork only.
Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
side wall cap w/ gravity damper
8” round horizontal ducting
Roof Pitch w/ Flashing & Cap
side wall cap w/ gravity damper
Sot or crawl space
8” round vertical ducting
8” round vertical ducting
Monsoon Connect Use, Care, and Installation Guide
11
CORE
Installation Instructions
Ů
(30”) 22-3/8”, (36”) 28-3/8”,
(42”) 34-3/8”, (48”) 40-1/4”
remote
antenna
3”
(30”) 28-3/8”, (36”) 34-3/8”,
(42”) 40-3/8”, (48”) 46-1/4”
2
1
1
-3/8
9
MONSOON
CONNECT
INSERT
12”
* 8” round ducting ** 10” round ducting
(30”) 11-3/16”
3/4 View
(30”) 9-1/4” (36”) 11-7/8” (42“) 14-7/8” (48”) 17-7/8”
elec.
7-11/16
k/o
10-3/8
C/L
5-1/2
*8-1/16”
**10-3/8”
Back View
(30” only) 5-9/16
(36“, 42”, 48“) 6-1/8”
C/L
*9-1/2” **14-3/16”
Top View
(36”) 14-3/16” (42“) 17­(48”) 17-
(30”) 9-1/4” (36”) 11-7/8” (42“) 14-7/8” (48”) 17-7/8”
Ø *7-
11/16
** 9-15/16”
3/16 7/8
2”
elec.
k/o
12
Monsoon Connect Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
Electrical Supply
WARNING
Electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
Cable Lock
FIG. A
Monsoon Connect Use, Care, and Installation Guide
13
CORE
28-3/8” or 34-3/8” or 40-3/8” or 46-1/4”
19
-
3/
8
cut o
u
t
(AK9428)
(AK9434)
(AK9446)
(AK9440)
1/4 po
1-1/8 po
Installation Instructions
Preparation & Installation
CAUTION
At least two installers are required due to the
weight and size of the liner.
1. Remove all packing materials and protective film prior to installation. Use caution during installation to prevent scratches or damage to the stainless steel. Remove safety screw on top of hood body.
2. Cut out an opening in the bottom of the cabinet by following the dimensions in FIG. B.
MONSOON
CONNECT
INSERT
FIG. B
3. Prepare liner for installation into cabinet by following the steps on page 15-16 for vertical ducting and 17-19 for horizontal ducting and 20-22 for dual blower installation, if desired.
4. Lift liner into bottom opening of cabinet and secure to interior of cabinet using (8) #8 x 1/2” stainless steel screws; (4) screws in the front and (4) screws in the sides. FIG. C.
WARNING
Make sure the surface you are securing the liner
to is capable of holding the weight of AK94.
Failure to do so may cause personal injury or
damage to cooking surface or counter.
5. If using RF remote control, remove the light panel by (5) screws and extend the blue antenna wire. There is no need to secure it. Reinstall light panel.
6. Finalize installation of electrical and duct work. Seal duct work with certified aluminum duct tape. Power on liner, check for leaks around duct tape and verify proper operation.
FIG. C
NOTE: If access to top of liner is not available after installation, electrical and duct work connection
7. Re-install the previously removed bottom panel, side spacer panels (if applicable), grease tray,
14
may need to be made prior to installing the liner.
and bae filters.
Monsoon Connect Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Preparation & Installation
1
2
Installation Instructions
1. Remove bae filters by: 1) Pulling filter toward front of liner. 2) Pivoting rear of filter down.
2. Remove grease tray by: 1) Pulling
1
2
1
up on tray to release from bottom panel. 2) Lifting tray out of liner body.
3. Remove left and right side­spacer panels by removing (2) screws from behind each panel, if applicable.
Monsoon Connect Use, Care, and Installation Guide
15
CORE
Installation Instructions
Preparation & Installation
1
Bottom Panel Screws
2
Locking Tabs
MONSOON
CONNECT
INSERT
4. Remove bottom panel by: 1) Removing (2) screws from left and right sides of bottom panel. 2) Pulling bottom panel toward front of liner to release from locking tabs.
5. Secure 8” or 10” round ducting collar to top of insert by (4) M4 x 6mm screws.
6. Vertical ducting preparation is complete. Refer to page 14, step 4 to complete installation.
16
Monsoon Connect Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Horizontal Ducting Preparation
Installation Instructions
1. Follow steps 1 to 4 from pages 15 and 16. Remove blower molex plug.
2. Remove blower from liner by removing the (4) 3/16” x 3/8” screws from the top of the liner. Set screws aside for later usage.
3. Using a flat head screwdriver, remove 8” round knock-out plate at the back of the liner.
Monsoon Connect Use, Care, and Installation Guide
17
CORE
Installation Instructions
Horizontal Ducting Preparation
4. Place top rectangular cover plate over opening on top of the liner. NOTE: Make sure the cover plate tabs are on top of the cover plate as shown. From inside the liner, secure plate to top of liner with (2) 3/16 x 3/8 screws.
At this point, install the liner into the cabinet by following the steps on page 14, step 4. After liner installation, continue on page 18.
MONSOON
CONNECT
INSERT
5. From inside the liner, push 8” round adapter through the back knock-out and secure to interior back wall of liner with (4) M4 x 6mm screws.
6. Secure (2) horizontal ducting blower brackets to blower as shown above by using the (4) 3/16” x 3/8” screws previously removed from Page 17, Step 2; (2) screws for each bracket.
18
Monsoon Connect Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Horizontal Ducting Preparation
Installation Instructions
2
1
1
7. Position blower inside liner body as shown by: 1) Rest the bottom horizontal ducting bracket on the two support clips located on the interior back wall of the liner.
2) Pivot top horizontal ducting bracket to meet captive nuts on interior back wall.
8. Secure blower to captive nuts on interior back wall of liner with (8) 3/16” x 3/8” screws, (4) screws for each bracket. Seal any gaps around the knock-out plate by using certified aluminum duct tape. Plug in blower molex plug.
Horizontal ducting preparation is now complete. Refer to page 14, step 5 to complete installation.
Monsoon Connect Use, Care, and Installation Guide
19
CORE
Installation Instructions
MONSOON
CONNECT
INSERT
PBD-1300B Dual Blower Installation
This range hood is equipped standard with a single blower vertical duct option. To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below.
PBD-1300B dual blower kit compatible only with AK9434BS, AK9440BS, and AK9446BS.
1. Remove the bae filters and if applicable, remove the side panels. Disconnect blower plug.
2. Remove (4) screws at top of hood body attaching blower to blower plate. Remove blower from interior of hood body.
3. Remove (4) screws from interior of hood body attaching blower plate to hood body. Remove blower plate.
4. Install dual blower plate from PBD-1300B kit into hood body. Attach by (4) screws previously removed from step 3.
20
Monsoon Connect Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
PBD-1300B Dual Blower Installation
5. Install previously removed blower
6. Install blower from PBD-1300B
onto one side of dual blower plate and attach by (4) previously removed screws from step 2.
kit onto other side of dual blower plate by (4) 3/16 x 3/8 screws.
7. Dual blower screw mount locations.
8. Remove (5) screws to remove the light panel. Install dual blower PCB inside the hood body.
Monsoon Connect Use, Care, and Installation Guide
21
CORE
Installation Instructions
PBD-1300B Dual Blower Installation
9. Refer to page 36-37 section for
10. Place 10” round adapter
MONSOON
CONNECT
INSERT
this step. Connect the wiring from the dual blower including both blower plugs, blower cable 6 pin connector (E), dual blower switch cable (H), black single pin power cord from dual blower (K), and white single pin power cord (F) to dual blower PCB.
(included with PBD-1300B) on top of hood and secure with (4) M3.5 x 8 screws.
NOTE: To secure the 10” transition adapter to top of hood a cut out of 14-1/2” width x 10-1/2” depth
will need to be made in the cabinet bottom.
If internal cabinet dimensions prevent this size of a cut out then the 10” transition adapter may be mounted to the cabinet bottom rather than the top of the hood. Cut out dimensions for this type of installation are 13-1/4” width x 6-1/4” depth.
22
Monsoon Connect Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Proximity Controls
Power Lights
PROXIMITY SENSOR
Ź When approaching the hood while it is powered o, the Power, Fan Decrease, Fan Increase,
and Light icons will illuminate, and “HELLO” will appear on the LCD display for 2 seconds.
Features & Controls
Display & Icons
Adjust 6 Speed Levels
Ź If neither the fan nor lights are turned on within 60 seconds, the icons will turn o, and
“GOODBYE” will appear on the LCD display for 2 seconds.
Ź The icons will not disappear until the fan and lights are turned o.
CONTROL ICONS
Power
Ź Press the power icon to power on or o the fan and lights.
Ź The hood has a memory function to remember the last used settings for the fan and lights.
Ź After pressing the power icon to power o the hood, “GOODBYE” will appear on the LCD
display for 2 seconds.
Ź The 3s icon under the power icon only illuminates when the fan is powered on. It is an
indicator to enable Automatic Delay O by pressing and holding the power button for 3 seconds.
Decrease Fan Speed
Ź Press the icon to decrease fan speed from 6, 5, 4, 3, 2, 1, o.
Increase Fan Speed
Ź Press the icon to increase fan speed from o, 1, 2, 3, 4, 5, 6.
Lights
Ź Press the lights icon to change lighting level from 1, 2, 3, o.
Monsoon Connect Use, Care, and Installation Guide
23
CORE
Features & Controls
Proximity Controls
DISPLAY ICONS & FUNCTIONS
Ů
Ź The notification bell icon will illuminate when an action needs to be taken. Tapping the
icon will cycle through the notifications. The notification bell will remain illuminated until all notifications are resolved. The notification bell will not illuminate when the hood and controls are powered o.
Bluetooth®
Ź The Bluetooth® icon will illuminate the device when connected with the hood via Bluetooth®.
The words “BLUETOOTH CONNECTED” or “BLUETOOTH DISCONNECT” will appear on the LCD display whenever the connection changes.
MONSOON
CONNECT
INSERT
Wi-Fi
Ź The Wi-Fi icon will illuminate when the hood is connected to the Wi-Fi. The words “WIFI
CONNECTED” or “WIFI DISCONNECTED” will appear on the LCD display whenever the connection changes which will be managed via the Zephyr Connect app.
Ű
Ź While the fan is on, press and hold for 3 seconds to enable the delay o timer. The fan will
change to speed 1, the timer display will illuminate, the LCD display will show “AUTOMATIC DELAY OFF”, and the timer will begin counting down from 10 minutes. After the timer reaches 0, the fan and lights will power o.
Ź The automatic delay o function timer begins at 10 minutes by default. The Zephyr Connect
app provides the options for either 5 or 10 minutes.
CleanAir
Ź When the fan is o, press and hold and simultaneously for 3 seconds to enable or
disable the CleanAir function. The LCD display will show “CLEAN AIR ENABLED” or “CLEAN AIR DISABLED”.
24
Ź When enabled, the fan will turn on speed 1 every 4 hours for 10 minutes. While the fan is
running, the LCD display will show “CLEAN AIR ACTIVE” and the CleanAir icon will illuminate.
Monsoon Connect Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Proximity Controls
ĻŮ
Ź Airflow Control Technology (ACT™) allows the installer to set the maximum fan CFM to align
with local codes and regulations. When the fan is o, press and hold display ACT™ status.
Ź ACT 290 = 3 speeds, ACT 390 = 4 speeds, ACT 590 = 5 speeds.
Grease Filter Clean Reminder
Ź After 60 hours of fan use, the notification bell icon will illuminate. When the bell is tapped,
the LCD display will cycle between showing “CLEAN GREASE FILTERS” and then “HOLD DOWN TO RESET” every 2 seconds. If no action is taken for 30 seconds, the display turns o and the notification bell icon will remain illuminated.
Ź To hold down and reset, press and hold the fan decrease button for 3 seconds to
reset. The Zephyr Connect app provides the option to reset the reminder.
Features & Controls
for 3 seconds to
Recirculating Mode - Charcoal Filter Replacement Reminder
Ź Hold and for 3 seconds to enable or disable recirculating mode which will remind you
to replace the charcoal filter. The LCD display will show “RECIRCULATING ENABLED” to enable and “RECIRCULATING DISABLE” to disable for 2 seconds.
Ź After 200 hours of fan use, the notification bell icon will illuminate. When the bell is tapped,
the LCD display will cycle between showing “REPLACE CHARCOAL FLTR” and “HOLD UP TO RESET” every 2 seconds. If no action is taken for 30 seconds, the display turns o and the notification bell will remain illuminated.
Ź To hold up and reset, press and hold the fan increase button for 3 seconds to reset.
The Zephyr Connect app provides the option to reset the reminder.
Remote Control Pairing Mode
Ź Hold for 3 seconds to enable remote control pairing mode. Once pairing mode is enabled,
the LCD display will illuminate “REMOTE PAIRING”. Press a button on the remote control to synchronize it with the hood.
Monsoon Connect Use, Care, and Installation Guide
25
CORE
Features & Controls
MONSOON
CONNECT
INSERT
Zephyr Connect
Your range hood is compatible with our Zephyr Connect app. All you need is a WiFi connection with access to the Internet that can reach the location of your range hood. Zephyr Connect allows you to control your range hood from anywhere using a mobile device or your Amazon Alexa or Google Home smart speaker. Zephyr Connect also includes real time diagnostics and provides you with important product information.
The Zephyr Connect app is available on iOS devices using iOS 11.0 or later or Android devices using Android version 8 or later. Visit the Apple App Store or Google Play Store for more information.
If your range hood is not connected to WiFi, the functionality will operate similarly to a typical range hood without WiFi connectivity.
Please review the included Zephyr Connect Quick Start Guide for more information.
If you have connected your hood with either Amazon Alexa or Google Home smart speakers, you now have voice control capabilities. The list of commands for Amazon Alexa and Google Home are on the next page.
NOTE: Amazon Alexa and Google Home cannot support the voice commands in French.
26
Monsoon Connect Use, Care, and Installation Guide
Features & Controls
ZEPHYRONLINE.COM
Zephyr Connect
Control Type Amazon Alexa Voice Commands Description
Power
Fan
Light
Delay-O
Alexa, turn on [Hood Name] Turn on range hood power Alexa, turn o [Hood Name] Turn o range hood power Alexa, increase [Hood Name] Fan Speed Increase fan speed on range hood Alexa, decrease [Hood Name] Fan Speed Decrease fan speed on range hood Alexa, set [Hood Name] Fan Speed to [1-6] Set range hood to specific fan speed Alexa, set [Hood Name] Fan Speed to Maximum Set fan speed to 6 on range hood Alexa, set [Hood Name] Fan Speed to Minimum Set fan speed to 1 on range hood Alexa, turn on [Hood Name] Light Turn on the light on range hood Alexa, turn o [Hood Name] Light Turn o the light on range hood Alexa, increase [Hood Name] Light(s) Increase light level on range hood Alexa, decrease [Hood Name] Light(s) Decrease light level on range hood Alexa, set [Hood Name] Light(s) to High
Alexa, set [Hood Name] Light(s) to Bright Alexa, set [Hood Name] Light(s) to Low
Alexa, set [Hood Name] Light(s) to Dim Alexa, set [Hood Name] Light(s) to [1-3] Set range hood to specific light level Alexa, set delay time to 1 minute on [Hood Name]
Alexa, set delay time to 2-10 minutes on [Hood Name] Alexa, [Start/Enable] [Hood Name] Delay O Timer Enable delay o timer for 10 minutes. After 10
Alexa, [Stop/Disable] [Hood Name] Delay O Timer Disable delay o timer
Set light level to High on range hood
Set light level to Low on range hood
Enable delay timer for 1-10 minutes. After 1-10 minutes, the hood will be power o.
minutes, the hood will power o.
Control Type Google Home Voice Command Description
Power
Fan
Light
Delay-O
Hey Google, turn on [Hood Name] Turn on range hood power Hey Google, turn o [Hood Name] Turn o range hood power Hey Google, increase [Hood Name] speed Increase fan speed on range hood
Hey Google, decrease [Hood Name] speed Decrease fan speed on range hood Hey Google, set [Hood Name] to speed [1-6] Set range hood to specific fan speed Hey Google, set [Hood Name] to maximum speed Set fan speed to the maximum on range hood Hey Google, set [Hood Name] to minimum speed Set fan speed to the minimum on range hood Hey Google, turn on [Hood Name] light(s) Turn on the light on range hood Hey Google, turn o [Hood Name] light(s) Turn o the light on range hood Hey Google, set [Hood Name] light(s) to High
Hey Google, set [Hood Name] light(s) to Bright Hey Google, set [Hood Name] light(s) to Low
Hey Google, set [Hood Name] light(s) to Dim Hey Google, set [Hood Name] light(s) to 1-3 Set range hood to specific light level Hey Google, Run [Hood Name] for 1-10 minutes Enable delay timer for 1-10 minutes. After 1-10
Hey Google, Start 1-10 minute timer on [Hood Name] Enable delay timer for 1-10 minutes. After 1-10
Hey Google, Stop [Hood Name] timer Disable delay timer Hey Google, Cancel [Hood Name] timer Disable delay timer
Set light level to High on range hood
Set light level to Low on range hood
minutes, the hood will be power o.
minutes, the hood will be power o.
Monsoon Connect Use, Care, and Installation Guide
27
Loading...