Your safety and the safety of others are very important.
We have provided many important safety messages in this manual for your appliance. Always read
and obey all safety messages.
This is the Safety Alert Symbol. This symbol alerts you to potential hazards that can cause severe
bodily injury or death. All safety messages will follow the Safety Alert Symbol and either the words
“DANGER” “WARNING” or “CAUTION”
MONSOON I
INSERT
DANGER
Danger means that failure to heed this safety
statement may result in severe injury or death.
WARNING
Warning means that failure to heed this safety
statement may result in extensive product damage,
serious personal injury, or death.
CAUTION
4
Caution means that failure to heed this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
Monsoon I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
General Safety
To reduce the risk of fire or electric shock, do not use this fan
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNING
with any solid-state control device.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning unit, switch power o at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
Monsoon I Use, Care, and Installation Guide
5
CORE
Safety Information
MONSOON I
INSERT
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food. (i.e. Crepes Suzette,
Cherries Jubilee, Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn o the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
6
Monsoon I Use, Care, and Installation Guide
Safety Information
ZEPHYRONLINE.COM
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
Monsoon I Use, Care, and Installation Guide
7
CORE
Safety Information
MONSOON I
INSERT
READ AND SAVE THESE INSTRUCTIONS
CAUTION
Ź To reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within
walls, ceilings, attics, crawl spaces, or garages.
Operation
Ź Always leave safety grilles and filters in place. Without these components, operating blowers could
catch onto hair, fingers and loose clothing.
Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given
here for installation, maintenance and suitable use of the product. The manufacturer further
declines all responsibility for injury due to negligence and the warranty of the unit automatically
expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility to be aware of these below:
Ź To contact a qualified electrical installer.
Ź To assure that the electrical installation is adequate and in conformance with National Electrical
Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1
and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician
determine that the ground path is adequate.
Ź Do not ground to a gas pipe.
Ź Check with a qualified electrician if you are not sure the range hood is properly grounded.
Ź Do not have a fuse in the neutral or ground circuit.
8
Monsoon I Use, Care, and Installation Guide
Safety Information
ZEPHYRONLINE.COM
READ AND SAVE THESE INSTRUCTIONS
Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly
grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire with ground. Please also refer to Electrical Diagram on product.
Ź A cable locking connector (not supplied) might also be required by local codes. Check with local
requirements, purchase and install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
Federal Communication Commission Interface Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment o and on, the user is encouraged to try to correct the interference by one
of the following measures:
Ź Reorient or relocate the receiving antenna.
Ź Increase the separation between the equipment and receiver.
Ź Connect the equipment into an outlet on a circuit dierent from that to which the receiver is
connected.
Ź Consult the dealer or an experienced radio/TV technician for help.
WARNING
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
Monsoon I Use, Care, and Installation Guide
9
CORE
List of Materials
Parts Supplied (AK9228BS & AK9234BS)
QuantityPart
1Liner hood body
2Bae filters
2LumiLight LED, 6W (pre-installed)
1Internal blower (pre-installed)
18” round adapter w/ damper
2Horizontal ducting blower mount
Ducting, conduit and all installation tools
Cable locking connector (if required by local codes)
Monsoon I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Ducting Calculation Sheet
Installation Instructions
Duct pieces
3- 1/ 4” x 10”
Rect.,
straight
6”, 7”, 8”, 10”
Round,
straight
3- 1/ 4” x 10”
0
Rect. 90
elbow
3- 1/ 4” x 10”
0
Rect. 45
elbow
3- 1/ 4” x 10”
0
Rect. 90
flat elbow
7” to 6” or
8” to 7” Round
tapered
reducer
6”, 7“, 8”
Round
in-line
damper
6”, 7”, 8”, 10”
Round,
0
90
elbow
6”, 7”, 8”, 10”
Round,
0
45
elbow
Equivalent number
length x used =
1 Ft. x ( ) =
1 Ft. x ( ) =
15 Ft. x ( ) =
9 Ft. x ( ) =
24 Ft. x ( ) =
25 Ft. x ( ) =
15
Ft. x ( ) =
15 Ft.
9 Ft. x ( ) =
x ( ) =
Subtotal column 1 =
To t a l
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Duct pieces
3- 1/ 4” x 10”
Rect. to
6” round
transition
3- 1/ 4” x 10”
Rect. to
6” round
transition
0
elbow
90
6” round to
3- 1/ 4” x 10”
rect.
transition
6” round to
3- 1/ 4” x 10”
rect.
transition
0
90
elbow
7” round to
3 1/ 4” x 10”
rect.
transition
7” round to
3- 1/ 4” x 10”
rect.
transition
0
elbow
90
3- 1/ 4” x 10”
Rect.
wall cap
with damper
6”, 7”, 8”, 10”
Round, wall
cap with
damper
6”, 7”, 8”, 10”
Round
roof cap
Equivalent number
length x used =
5 Ft. x ( ) =
20 Ft. x ( ) =
1 Ft. x ( ) =
16 Ft. x ( ) =
8 Ft. x ( ) =
23 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
To t a l
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 150 equivalent feet.
Monsoon I Use, Care, and Installation Guide
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Ft.
Ft.
Ft.
11
CORE
Installation Instructions
Mounting Height, Clearance, & Ducting
MONSOON I
INSERT
24” min.
36” max.
36”
12
Monsoon I Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
Mounting Height, Clearance, & Ducting
A minimum of 8” round for AK9228BS and AK9234BS must be used to maintain maximum air flow
eciency.
A minimum of 10” round duct for AK9240BS and AK9246BS must be used to maintain maximum air
flow eciency. Horizontal ducting is not available for AK9240BS and AK9246BS.
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Also use the ducting calculation sheet (on page 11) to compute total available duct run when using
elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood bottom should be no less than 24”.
Maximum mount height should be no higher than 36”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result
in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its
performance and eciency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood
mounting height above range.
For shipment and installation damages:
Ź Please fully inspect unit for damage before installation.
Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.
Monsoon I Use, Care, and Installation Guide
13
CORE
Installation Instructions
MONSOON I
Ducting Options
WARNING
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
Ź Use single wall rigid metal ductwork only.
Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
AK9228AS & AK9234AS
Models Only
INSERT
side wall cap
w/ gravity damper
Roof Pitch w/
Flashing & Cap
side wall cap
w/ gravity
damper
Sot or crawl space
14
Monsoon I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Ů
3”
28-
40-
3/8
”, 34-
3/8
”, 46-
7/8”
(40”, 46”) 5-
(28”, 34”) 5-5/8”
12”
3/8
1/2”
* 1-
3/8
”
”
3/4 View
Installation Instructions
22-
34-
3/8
”, 28-
3/8
”, 40-
3/8
”
3/8
”
12”
”
1/4
19-
(28”) 14-1/4”
(34”) 17(40”) 20(46”) 23-
(28”) 9(34”) 12(40”) 15(46”) 18-
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
2”
3/4”
10-
elec.
k/o
C/L
To p
* 7-3/4”
C/L
1/2”
Back
* Dimensions for 28” and 34” model sizes only
* 5-
Ø 9-3/4”
Ø 7-3/4”
(40”, 46”)
(28”, 34”)
Monsoon I Use, Care, and Installation Guide
15
CORE
Installation Instructions
MONSOON I
INSERT
Electrical Supply
WARNING
Electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
Cable Lock
FIG. A
16
Monsoon I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
2
8-
1/2
”
19
-
3
/
8
”
cu
t
out
(AK9228)
4
6-
1/2
”
(AK9246)
40-
1/2
”
(AK9234)
34
-
1/2
”
(AK9240)
9”
9”
C/L
CABINET BACK
8” Round
5-1/2”
Preparation & Installation
CAUTION
At least two installers are required due to the
weight and size of the liner.
1. Remove all packing materials and protective
film prior to installation. Use caution during
installation to prevent scratches or damage to
the stainless steel.
2. Cut out an opening in the bottom of the
cabinet by following the dimensions in FIG. B.
If ducting the one piece liner horizontally, also
cut out an opening in the back of the cabinet
(if applicable). FIG. C.
Installation Instructions
FIG. B
3. Prepare liner for installation into cabinet by
following the steps on page 19-20 for vertical
ducting or pages 21-22 for horizontal ducting.
Continue to Step 4 after preparation is
completed.
WARNING
Make sure the surface you are securing the liner
to is capable of holding the weight of AK92.
Failure to do so may cause personal injury or
damage to cooking surface or counter.
Monsoon I Use, Care, and Installation Guide
FIG. C
17
CORE
1/4”
1-
1/8
”
Installation Instructions
Preparation & Installation
4. Lift liner into bottom opening of cabinet and
secure to interior of cabinet using (8) #8 x 1/2”
stainless steel screws; (4) screws in the front
and (4) screws in the sides. FIG. D.
5. Finalize installation of electrical and duct work.
Seal duct work with certified aluminum duct
tape. Power on liner, check for leaks around
duct tape and verify proper operation.
NOTE: If access to top of liner is not available
after installation, electrical and duct work
connection may need to be made prior to
installing the liner.
MONSOON I
INSERT
6. Re-install the previously removed bottom panel,
side spacer panels (if applicable), grease tray,
and bae filters.
FIG. D
18
Monsoon I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Vertical Ducting Preparation
1
2
Installation Instructions
1. Remove bae filters by: 1) Pulling
filter toward front of liner. 2)
Pivoting rear of filter down.
2. Remove grease tray by: 1) Pulling
1
2
1
up on tray to release from bottom
panel. 2) Lifting tray out of liner
body.
3. (If applicable) Remove left and
right side-spacer panels by
removing (2) screws from behind
each panel.
Monsoon I Use, Care, and Installation Guide
19
CORE
Installation Instructions
Vertical Ducting Preparation
1
Bottom Panel Screws
2
Locking Tabs
MONSOON I
INSERT
4. Remove bottom panel by: 1)
Removing (2) screws from left and
right sides of bottom panel. 2)
Pulling bottom panel toward front
of liner to release from locking
tabs.
5. Secure 8” round adapter or 10”
round adapter to top of liner by
(4) M4 x 6mm screws.
6. Vertical ducting preparation is
complete. Refer to page 18, step
4 to complete installation.
20
Monsoon I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Horizontal Ducting Preparation
1
2
Installation Instructions
AK9228BS & AK9234BS Models Only
1. Remove bae filters by: 1) Pulling
filter toward front of liner. 2)
Pivoting rear of filter down.
2. Remove grease tray by: 1) Pulling
1
2
1
up on tray to release from bottom
panel. 2) Lifting tray out of liner
body.
3. (If applicable) Remove left and
right side-spacer panels by
removing (2) screws from behind
each panel.
Monsoon I Use, Care, and Installation Guide
21
CORE
Installation Instructions
Horizontal Ducting Preparation
1
Bottom Panel Screws
2
Locking Tabs
MONSOON I
INSERT
AK9228BS & AK9234BS Models Only
4. Remove bottom panel by: 1)
Removing (2) screws from left and
right sides of bottom panel. 2)
Pulling bottom panel toward front
of liner to release from locking
tabs.
5. Disconnect blower molex plug.
6. Remove blower from liner by
removing the (4) 3/16” x 3/8”
screws from the top of the liner.
Set screws aside for later usage.
22
Monsoon I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
At this point, install the one piece liner
into the cabinet by following the steps
on Page 18, Step 4. After the liner
installation, continue to page 24.
Horizontal Ducting Preparation
Installation Instructions
AK9228BS & AK9234BS Models Only
7. Using a flat head screwdriver,
remove 8” round knock-out
plates at the back of the liner.
8. Remove the round ducting knockout.
9. Place top rectangular cover plate
over opening on top of the liner.
NOTE: Make sure the cover plate
tabs are on top of the cover plate
as shown. From inside the liner,
secure plate to top of liner with
(2) 3/16 x 3/8 screws.
At this point, install the one piece liner
into the cabinet by following the steps
on Page 18, Step 4. After the liner
installation, continue to page 24.
Monsoon I Use, Care, and Installation Guide
23
CORE
Installation Instructions
Horizontal Ducting Preparation
MONSOON I
INSERT
AK9228BS & AK9234BS Models Only
10. From inside the liner, push 8”
round adapter through the back
knock-out and secure to interior
back wall of liner with (4) M4 x
6mm screws.
11. Secure (2) horizontal ducting
blower brackets to blower as
shown above by using the (4)
3/16” x 3/8” screws previously
removed from Page 22, Step 6;
(2) screws for each bracket.
2
1
1
12. Position blower inside liner body
as shown by: 1) Rest the bottom
horizontal ducting bracket on
the two support clips located on
the interior back wall of the liner.
2) Pivot top horizontal ducting
bracket to meet captive nuts on
interior back wall.
24
Monsoon I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Horizontal ducting preparation is now
complete. Refer to Page 18, Step 5 to
complete installation.
Horizontal Ducting Preparation
Installation Instructions
AK9228BS & AK9234BS Models Only
13. Secure blower to captive nuts on
interior back wall of liner with (8)
3/16” x 3/8” screws, (4) screws
for each bracket. Seal any gaps
around the knock-out plate by
using certified aluminum duct
tape. Plug in blower molex plug.
Horizontal ducting preparation is now
complete. Refer to Page 18, Step 5 to
complete installation.
Monsoon I Use, Care, and Installation Guide
25
CORE
Features & Controls
MONSOON I
INSERT
Touch Controls
1
Blower On/O
2
Adjust 6 Speed Levels
1. Blower On/O
By pressing the blower is switched on and o. When switched on, the blower starts up on speed level 1.
ACT Verification
- Airflow Control Technology (ACT) allows the installer to set the maximum blower CFM to align with local
codes and regulations.
- To verify the maximum blower CFM for AK9228BS and AK9234BS models:
- With hood o, hold the button for 3-4 seconds. If number 6 displays = default max. CFM, if
number 3 displays = max. 390 CFM, and if number 2 displays = max. 290 CFM.
- To verify the maximum blower CFM for AK9240BS and AK9246BS models:
- With hood o, hold the button for 3-4 seconds. If number 6 displays = default max. CFM, if
number 3 displays = max. 590 CFM, and if number 2 displays = max. 390 CFM.
Display (speed level, delay o, filter clean)
5
Lights Low/High/O
4
3
5 Min Delay O
2. Speed Selection
- Press to decrease fan speed. 6, 5, 4, 3, 2, 1.
- If fan is on Speed 1 and is pressed, the fan will power o.
- Press to increase fan speed. Fan On, 1, 2, 3, 4, 5, 6.
- If hood is o and is pressed, the fan will turn on speed 1.
ACT Enabled Speed Selections
- When ACT is enabled, the number of blower speeds will be reduced as follows:
AK9228BS & AK9234BS AK9240BS & AK9246BS
- 390 CFM = Maximum 3 speeds - 590 CFM = Maximum 3 speeds
- 290 CFM = Maximum 2 speeds - 390 CFM = Maximum 2 speeds
3. Delay O
This feature is used for programmed shut down of blower 5 minutes after the function is activated. Press
once, a dot flashes in the lower right side of display indicating the function is on. The blower will
completely shut down after 5 minutes.
4. Lights Low/High/O
Switch lights on to low by pressing once, press a second time for high and again to shut o lights.
5. Display Window
The display window indicates speed levels and features such as bae filter clean reminder, delay o and
clean air indicator.
26
Monsoon I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
F
F
F
A
A
A
1
1
A
F
F
Touch Controls
Bae Filter Clean Reminder
A set of bae filters are fitted by the factory, these bae filters are intended to filter
out residue from cooking. The filters need not be replaced on a regular basis but are
required to be kept clean. The BaeFilter Clean reminder function in the microprocessor will automatically indicate by a flashing when the bae filters need to be
cleaned after every 60 hours of use. Filters can be cleaned by hand with non-abrasive
soap or in a dishwasher. Heavily soiled filters should also be soaked in grease cutting
detergent prior to cleaning.
Features & Controls
Bae Filter Clean Indicator
When flashes on the display, the bae
filters needo be cleaned. This will occur
after every 60 hours of use.
Reset the filter clean reminder timer after
filters are cleaned and re-installed. With
hood o, press and hold for approximately 5 seconds until on display
disappears . The filter clean reminder
function is now reset and a new 60 hours
elapse cycle is initiated.
Clean Air Function
Clean Air is a feature that turns on the blower on low speed every 4 hours for 10 minutes
to remove stagnant air in the kitchen. The Clean Air function is disabled by default and
must be enabled by the user.
Clean Air Indicator
While Clean Air is active, the display will
alternate between , , , .
After 10 minutes of Clean Air operation, the
blower will power o and the 4 hour timer
will reset.
Clean Filters
display < F > flashes
To Reset
hold 5 sec.display from < F > to < >
To Enable
hold 3 sec.
and
To Disable
hold 3 sec.display from < A > to < >
display < A > flashes
If the blower speed is changed while the
Clean Air Function is in use, the cycle will be
interrupted and the timer will reset after.
Monsoon I Use, Care, and Installation Guide
and
27
Loading...
+ 61 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.