Zephyr AK8300BSX, AK8200BS Use, Care, and Installation Guide

WWW.ZEPHYRONLINE.COM
Tornado II
AK8200BS
Tornado III
AK8300BSX (blower sold separately)
EN Use, Care, and Installation Guide
FR Guide d’utilisation, d’entretien et d’installation
JUL21.0201
PRO
TORNADO II &
TORNADO III
INSERT
Tornado II & Tornado III Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information ............................................................................ 4-6
Types of Safety Warnings ................................................................... 4
General Safety ..................................................................................4-5
Operation ........................................................................................... 6
Electrical Requirements ...................................................................... 6
Federal Communication Commission Interface Statement ................. 6
List of Materials ................................................................................... 7
Installation Instructions .....................................................................8-16
Ducting Calculation Sheet .................................................................. 8
Mounting Height, Clearance, & Ducting ............................................. 9
Ducting Options .................................................................................10
Hood Specifications ............................................................................11
Electrical Supply .................................................................................12
Cable Lock .........................................................................................12
Preparation & Installation ...................................................................13
Repositioning the Electrical Box ..........................................................14
AK8300BSX Single & Dual Internal Blower Installation .........................15
AK8300BSX Remote Blower Preparation .............................................16
Features & Controls ..........................................................................17-20
Touch Controls .................................................................................17-18
RF Remote Control ..........................................................................19-20
Maintenance ....................................................................................21-22
Hood & Filter Cleaning .....................................................................21-22
LumiLight LED ................................................................................... 22
Wiring Diagram ............................................................................... 23-24
Troubleshooting............................................................................... 25-26
List of Parts & Accessories .................................................................. 27
Notes ..................................................................................................28
Limited Warranty ...............................................................................29
Product Registration ...........................................................................30
Contents
Page
Tornado II & Tornado III Use, Care, and Installation Guide
3
PRO
Safety Information
READ AND SAVE THESE INSTRUCTIONS
Your safety and the safety of others are very important.
We have provided many important safety messages in this
manual for your appliance. Always read and obey all safety
messages.
This is the Safety Alert Symbol. This symbol alerts you to
potential hazards that can cause severe bodily injury or death.
All safety messages will follow the Safety Alert Symbol and either
the words “DANGER” “WARNING” or “CAUTION”
DANGER
Danger means that failure to heed this safety statement may
result in severe injury or death.
WARNING
TORNADO II &
TORNADO III
INSERT
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power o at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
Warning means that failure to heed this safety statement may result in extensive product damage, serious personal
injury, or death.
CAUTION
Caution means that failure to heed this safety statement
may result in minor or moderate personal injury, property or
equipment damage.
General Safety
WARNING
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state control device.
WARNING
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
Tornado II & Tornado III Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn o the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned. c) DO NOT USE WATER, including wet dishcloths or towels – a
violent steam explosion will result. d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors. e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within walls, ceilings, attics,
crawl spaces, or garages.
WARNING
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
Tornado II & Tornado III Use, Care, and Installation Guide
5
PRO
Safety Information
TORNADO II &
TORNADO III
INSERT
READ AND SAVE THESE INSTRUCTIONS
Operation
Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and
loose clothing.
Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
Ź Observe all governing codes and ordinances. Ź It is the customer’s responsibility to be aware of these below: Ź To contact a qualified electrical installer. Ź To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest
edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path
is adequate.
Ź Do not ground to a gas pipe. Ź Check with a qualified electrician if you are not sure the range hood is properly grounded. Ź Do not have a fuse in the neutral or ground circuit. Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected
by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram
on product.
Ź A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and
install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
Federal Communication Commission Interface Statement
Ź This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Ź This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one of the following
measures:
Ź Reorient or relocate the receiving antenna.
Ź Increase the separation between the equipment and receiver.
Ź Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Ź Consult the dealer or an experienced radio/TV technician for help.
6
Tornado II & Tornado III Use, Care, and Installation Guide
ZEPHYRONLINE.COM
List of Materials
Parts Supplied (AK8200BS)
Quantity Part
1 Insert hood 2 Pro bae filters 2 LumiLight LED, 6W (pre-installed)
1 Dual internal blower (pre-installed)
1 10” round adapter w/ damper
1 RF remote control
1 Hardware package
M4 x 8 (4)
Parts Supplied (AK8300BSX)
Quantity Part
1 Insert hood 3 Pro bae filters 4 LumiLight LED, 6W (pre-installed)
1 Single blower mounting plate
1 Remote blower wiring harness
1 10” round adapter w/ damper
1 RF remote control
1 Hardware package
M4 x 1” (4)
Wire Caps (3)
RF Remote Control (1) Remote Holder (1)
Parts Not Supplied
Ducting, conduit and all installation tools Cable locking connector (if required by local codes) Single internal blower (CBI-290C, CBI-390A, CBI-600A) - AK8300BSX only Dual internal blower (PBI-1100B) - AK8300BSX only External blower (CBE-1000) - AK8300BSX only In-line blower (PBN-1000A) - AK8300BSX only Optional stainless steel hood liner (AK08xxAS)
Tornado II & Tornado III Use, Care, and Installation Guide
7
PRO
Installation Instructions
Ducting Calculation Sheet
Duct pieces
3- 1/ 4” x 10” Rect., straight
6”, 7”, 8”, 10” Round, straight
3- 1/ 4” x 10” Rect. 90 elbow
3- 1/ 4” x 10” Rect. 45 elbow
3- 1/ 4” x 10” Rect. 90 flat elbow
7” to 6” or 8” to 7” Round tapered reducer
6”, 7“, 8” Round in-line damper
6”, 7”, 8”, 10” Round,
0
90
elbow
6”, 7”, 8”, 10” Round,
0
45
elbow
Equivalent number length x used =
1 Ft. x ( ) =
1 Ft. x ( ) =
15 Ft. x ( ) =
0
9 Ft. x ( ) =
0
24 Ft. x ( ) =
0
25 Ft. x ( ) =
15
Ft. x ( ) =
15 Ft.
9 Ft. x ( ) =
Subtotal column 1 =
x ( ) =
To t a l
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Duct pieces
3- 1/ 4” x 10” Rect. to 6” round transition
3- 1/ 4” x 10” Rect. to 6” round transition
0
elbow
90
6” round to 3- 1/ 4” x 10” rect. transition
6” round to 3- 1/ 4” x 10” rect. transition
0
90
elbow
7” round to 3 1/ 4” x 10” rect. transition
7” round to 3- 1/ 4” x 10” rect. transition
0
elbow
90
3- 1/ 4” x 10” Rect. wall cap with damper
6”, 7”, 8”, 10” Round, wall cap with damper
6”, 7”, 8”, 10” Round roof cap
Equivalent number length x used =
5 Ft. x ( ) =
20 Ft. x ( ) =
1 Ft. x ( ) =
16 Ft. x ( ) =
8 Ft. x ( ) =
23 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
TORNADO II &
TORNADO III
INSERT
To t a l
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
8
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 150 equivalent feet.
Tornado II & Tornado III Use, Care, and Installation Guide
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Ft.
Ft.
Ft.
Installation Instructions
ZEPHYRONLINE.COM
Mounting Height, Clearance, & Ducting
A minimum of 10” round duct must be used for AK8200BS to maintain maximum air flow eciency.
A minimum of 6” or 10” round duct must be used for AK8300BSX.
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Also use calculation (on page 8) to compute total available duct run when using elbows, transitions and caps.
Min 24” - Max 36”
36”
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its performance and eciency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood mounting height above range.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size.
If turns or transitions are required; install as far away from hood duct output and as far apart, between the two as possible.
Minimum mount height between range top to hood bottom should be no less than 24”.
Maximum mount height should be no higher than 36”.
For shipment and installation damages:
Ź Please fully inspect unit for damage before installation.
Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.
Tornado II & Tornado III Use, Care, and Installation Guide
9
PRO
Installation Instructions
TORNADO II &
TORNADO III
Ducting Options
WARNING
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
Ź Use single wall rigid metal ductwork only.
Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
INSERT
side wall cap w/ gravity damper
Roof Pitch w/ Flashing & Cap
side wall cap w/ gravity damper
Sot or crawl space
10
Tornado II & Tornado III Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Ů
14-3/16”
10-3/8”
13-7/8”
C/L
26-7/8”
6-3/8”
9-15/16”
Installation Instructions
25-15/16”
25-1/8”
C/L
15-13/16”
29-3/16”
4-5/16”
11-1/2”
AK8200BS
Top
14-11/16”
11-7/16”
5-1/4”
2-1/2”
15-13/16”
AK8200BS
Front
AK8200BS & AK8300BSX
Side
34-1/2”
33-3/4”
14-3/16”
6-3/8”
10-3/8”
13-7/8”
C/L
15-13/16”
C/L
4-5/16”
11-1/2”
9-15/16”
35-7/16” 38-3/8”
AK8300BSX
Top
Tornado II & Tornado III Use, Care, and Installation Guide
AK8300BSX
Front
11
PRO
Installation Instructions
TORNADO II &
TORNADO III
INSERT
Electrical Supply
WARNING
Electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
Cable Lock
FIG. A
12
Tornado II & Tornado III Use, Care, and Installation Guide
ZEPHYRONLINE.COM
cabinet bottom cut-out size
26-1/16” - 34-11/16
AK8200BS AK8300BSX
14-3/4
Front View
minimum 3/4” wood base
metal or other non combustible material
(4) M4 ss wood screws (1) in each corner
F
ront View
m
inimum
3/4” wood base
Ductwork
Elec.
Preparation & Installation
CAUTION
At least two installers are required due to the
weight and size of the insert.
1. Install blower into insert: AK8200BS - Blower is pre-installed AK8300BSX - Refer to page 15 for instructions
NOTE: Remove blower mounting support screw
located on top of the motor housing before installing the hood into cabinet.
Installation Instructions
FIG. B
2. Install 10” round adapter to the top of insert
3. Install optional AK08xxAS Stainless Steel Liner. Review manual included with liner for more details.
4. If no liner is used, cut an opening in the bottom of the cabinet by following the dimensions in FIG. B.
5. Lift insert into opening and secure to bottom of cabinet using (4) M4 stainless steel screws, (1) in each corner; see FIG. C.
NOTE: Wood blocking may need to be added
to cabinet base if additional support is needed.
6. Install ductwork and seal with duct tape.
7. Install electrical.
8. Remove all packaging materials before using insert. Switch power on and check for leaks around duct tape.
FIG. C
9. Install bae filters.
Tornado II & Tornado III Use, Care, and Installation Guide
13
PRO
Installation Instructions
TORNADO II &
TORNADO III
Repositioning the Electrical Box
The electrical box in the front can be repositioned to the top of the blower housing if additional clearance is required during installation.
1. Remove the (2) screws from the electrical box in front of the blower housing.
INSERT
2. Position the electrical box on top of the blower housing and secure with (2) screws. Reroute the wiring inside the hood for the new electrical box placement.
14
Tornado II & Tornado III Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
AK8300BSX Single & Dual Internal Blower Installation
Multiple blowers are compatible with AK8300BSX only. CBI-290C, CBI-390A, and CBI-600A are single internal blowers and PBI-1100B is a dual internal blower. For remote blower preparation instructions, turn to page 16.
1. Position blower plate over the bracket inside the back of the hood and pivot up. Secure the plate to insert with (2) 3/16x3/8” screws. If using single blower, replace current blower plate with
OR
the single blower mounting plate.
Dual Blower Bracket
Single Blower Bracket
2. Connect both 6 pin male connectors from blower wiring to both 6 pin female connectors in the insert. For single blower, connect 9 pin to 6 pin adapter cable. The 9 pin end connects to the blower, and the 6 pin end connects to the hood.
3. Single Blower - Connect 6” round ductwork to blower collar.
Dual Blower - Place 10” round adapter on top of insert and secure it with (4) M4x8 screws. Connect 10” round ductwork to 8” round adapter.
Tornado II & Tornado III Use, Care, and Installation Guide
15
PRO
Installation Instructions
AK8300BSX Remote Blower Preparation
1. Place 10” round adapter on top of insert and secure it with (4) M4x8 screws. Connect 10” round ductwork to 10” round adapter.
2. Install threaded end of remote blower wiring through external blower wiring knock out locked in junction box on top of insert.
TORNADO II &
TORNADO III
INSERT
3. Place cap over threaded end of remote blower wiring and secure by turning clockwise. Connect 6 pin male connector from blower wiring to 6 pin female connector in the insert.
CBE-1000 / PBN-1000A: WIRING DIAGRAM
4. Secure green ground wire from remote blower wiring to ground screw located inside the insert.
Remote Blower
Wiring Box
(hood)
White (common) Black (high) Blue (med) Red (low) Green (ground)
Junction Box
(Remote Blower)
NOTE: For instructions on installing remote blowers, please refer to the CBE-1000 or PBN-1000A
manuals included in the blower packaging and on our website: www.zephyronline.com
16
Tornado II & Tornado III Use, Care, and Installation Guide
Features & Controls
ZEPHYRONLINE.COM
Touch Controls
1
Blower On/O
2
Adjust 3 Speed Levels
1. Blower On/O
By pressing the blower is switched on and o. When switched on, the blower starts up on speed level 1.
Display (speed level, delay o, filter clean)
5
4
Lights Low/Medium/High/O
3
5 Min Delay O
2. Speed Selection
- Press to decrease fan speed. 3, 2, 1.
- If fan is on Speed 1 and is pressed, the fan will power o.
- Press to increase fan speed. Fan On, 1, 2, 3.
- If hood is o and is pressed, the fan will turn on speed 1.
3. Delay O
This feature is used for programmed shut down of blower 5 minutes after the function is activated. Press once, a dot flashes in the lower right side of display indicating the function is on. The blower will completely shut down after 5 minutes.
4. Lights Low/Medium/High/O
Switch lights on to low by pressing once, press a second time for medium, press a third time for high and again to shut o lights.
5. Display Window
The display window indicates speed levels and features such as bae filter clean reminder, delay o and clean air indicator.
Tornado II & Tornado III Use, Care, and Installation Guide
17
PRO
F
F
F
A
A
A
1
1
A
F
F
Features & Controls
Touch Controls
Bae Filter Clean Reminder
A set of bae filters are fitted by the factory, these bae filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The Bae Filter Clean reminder function in the microproces­sor will automatically indicate by a flashing when the bae filters need to be cleaned after every 60 hours of use. Filters can be cleaned by hand with non-abrasive soap or in a dishwasher. Heavily soiled filters should also be soaked in grease cutting detergent prior to cleaning.
Bae Filter Clean Indicator
When flashes on the display, the bae filters needo be cleaned. This will occur after every 60 hours of use.
Reset the filter clean reminder timer after filters are cleaned and re-installed. With hood o, press and hold for approxi­mately 5 seconds until on display disappears . The filter clean reminder function is now reset and a new 60 hours elapse cycle is initiated.
TORNADO II &
TORNADO III
INSERT
Clean Filters
display < F > flashes
To Reset
hold 5 sec. display from < F > to < >
Clean Air Function
Clean Air is a feature that turns on the blower on low speed every 4 hours for 10 minutes to remove stagnant air in the kitchen. The Clean Air function is disabled by default and must be enabled by the user.
Clean Air Indicator
While Clean Air is active, the display will alternate between , , , .
After 10 minutes of Clean Air operation, the blower will power o and the 4 hour timer will reset.
If the blower speed is changed while the Clean Air Function is in use, the cycle will be interrupted and the timer will reset after.
To Enable
hold 3 sec.
and
To Disable
hold 3 sec. display from < A > to < >
and
display < A > flashes
18
Tornado II & Tornado III Use, Care, and Installation Guide