THIS KIT INCLUDES:
ZRC-0100 Recirculating Kit Instructions
(1) return air vent (1) charcoal filter (1) charcoal filter
1. Position and install charcoal filter bracket into
AK8000AS as shown above.
(4) return air
vent screws
(4) bracket
screws
2. Secure filter bracket to AK8000AS body by
installing a bracket screw into each of the (4)
corners.
bracket.
3. Install charcoal filter (plastic side up) into
filter bracket. Insert tab cut-out side A of
charcoal filter into bracket first. Lock
charcoal filter into place by pushing down
on side B with locking tabs.
APR10.0201 - XP022173(1)
A
B
Turn to next page for instructions
on installing return air vent.
1
To install the return air vent to top of the cabinet:
(for installations where cabinet does not extend to the ceiling)
1. Cut a 6-1/2” round opening in top of the
cabinet where the ducting will connect
to the return air vent. FIG.1
2. Connect 6” round ducting from AK8000AS to
return air vent collar. Return air vent collar
will go around the ducing. Secure with duct tape.
3. Secure return air vent to top of cabinet with
(4) screws.
To install the return air vent to a soffit or ceiling:
(for installations where top of cabinet is flush with the ceiling)
1. Cut a 6-1/2” round opening in soffit or ceiling
where the ducting will connect to the return
air vent. FIG.2
2. Connect 6” round ducting from AK8000AS to
return air vent collar. Return air vent collar
will go around the ducing. Secure with duct tape.
3. Secure return air vent to soffit or ceiling with
(4) screws.
ZRC-0100 Recirculating Kit Instructions
screw (1 in each corner
of return air vent)
screw (1 in each corner
of return air vent)
top of cabinet
soffit or
ceiling
top of cabinet
Return Air Vent
6” round
duct from
AK8000AS
FIG.1
Return Air Vent
FIG.2
note: Return air vent deflectors should face
the sides to properly vent the air. FIG.4
airflow airflow
FIG.3
2