Zephyr AK8000AS, AK8200S, AK8100S User Manual

Use, Care and Installation Guide
Read all Instructions before Installing and operating this appliance
Important Safety Notice
MODEL:
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b. Always turn hood ON when cooking at high heat or when flaming food
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d. Use proper pan size. Always use cookware appropriate for the size of the surface element. e. Keep fan, filters and grease laden surfaces clean. f. Use high setting on hood only when necessary. g. Don’t leave hood unattended when cooking. h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
a. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b. NEVER PICK UP A FLAMING PAN – You may be burned. c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
AK8000AS, AK8100S, AK8200S
READ AND SAVE THESE INSTRUCTIONS
Important Safety Notice
Read and save these instructions
d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done by qualified person (s) in accordance with all applicable codes and standards. Including fire-rated construction. b. Sufficient air is needed for power combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. c. When cuttig or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d. Ducted fans must always vent to the outdoors.
e. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCL (Ground Fault Interrupter protected branch circuit).
g. NEVER place a switch where it can be reached from a tub or shower. h. Make sure the power is off before installing, wiring or maintenancing.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
WARNING
TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL CONTROL/SWITCH.
OPERATION
Always leave safety grills and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
JAN07.0201 www.zephyronline.com
MOUNT HEIGHTS
INSTALLATION
Min 24"-Max 32"
36"
Minimum mount height between range top to hood bottom should be no less than 24".
Maximum mount height should be no higher than 32".
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and re haz­ard; while hoods mounted too high will be hard to reach and will loose its performance and eciency.
If available, also refer range manufacturer's height clearance requirements and recom­mended hood mounting height above range.
Minimum clearance of 24”hood above range
height.
Maximum clearance 32" hood above range height.
DUCTING
(AK8000AS, AK8100S, AK8200S)
A minimum of 6" round or 3-1/4” x 10"rectangular duct must be used to maintain maximum air ow eciency for AK8000/AK8100 and 8” minimum must be used for AK8200.
Always use rigid type metal ducts only. Flexible ducts could restrict air ow by up to 50%.
Also use calculation (on right) to compute total available duct run when using elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size from 6" to 7” or 8". If a reducer is used, install a long reducer instead of a pancake reducer. Reduce duct size as far away from open­ing as possible.
If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.
Minimum Duct Size:
Round: 6" minimum for AK8000AS/AK8100S 8" minimum for AK8200S Rectangular: Requires an adapter. Readily available at most hardware stores.
Duct Run Calculation:
Maximum run AK8000
AK8100 (6" or 3-1/4” x 10") AK8200 (8”)
Deduct: each 90 Elbow used each 45 elbow used each 6" to 3/14 x 10" transition used each 3/14 x 10" to 6" each 3/14 x 10" to 6" transition used Side Wall Cap w/ damper Roof Cap
e.g.- 1 roof cap, 2x90 elbows, 1 45 elbow used:
=30' + 30' + 9' =69' used, 31' available for straight duct runs.
100 FT
15 FT
9FT
1FT
5FT 30 FT 30 FT
Page 1
INSTALLATION
INSTALLATION
DUCTING
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside.
Use Metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certied Silver Tape or Duct Tape.
Some Ducting Options:
side wall cap w/ gravity damper
Sot or crawl space
side wall cap w/ gravity damper
SPECIFICATIONS
Twister (AK8000AS)
9-27/32”
5”
BACK
1-1/16”
26-19/32”
27-9/16”
11-13/16”
5-15/16”
4-3/32”
10-11/16”
1-5/32”
10-5/16”
1-1/4”
11-13/16”
Roof Pitch w/ Flashing & Cap
3-3/4”
FRONT
Page 2 Page 3
C/L
cut out dimension
26-7/8” (cut out)
10-5/8” (cut out)
= cut out dimension