Your safety and the safety of others are very important.
We have provided many important safety messages in this
manual for your appliance. Always read and obey all safety
messages.
This is the Safety Alert Symbol. This symbol alerts you to
potential hazards that can cause severe bodily injury or death.
All safety messages will follow the Safety Alert Symbol and either
the words “DANGER” “WARNING” or “CAUTION”
DANGER
Danger means that failure to heed this safety statement may
result in severe injury or death.
WARNING
TIDAL I
UNDERCABINET
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power o at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
Warning means that failure to heed this safety statement
may result in extensive product damage, serious personal
injury, or death.
CAUTION
Caution means that failure to heed this safety statement
may result in minor or moderate personal injury, property or
equipment damage.
General Safety
WARNING
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state control device.
WARNING
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
4
Tidal I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn o the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a
violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you
already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside, do
not vent exhaust air into spaces within walls, ceilings, attics,
crawl spaces, or garages.
WARNING
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
Tidal I Use, Care, and Installation Guide
5
PRO
Safety Information
TIDAL I
UNDERCABINET
READ AND SAVE THESE INSTRUCTIONS
Operation
Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and
loose clothing.
Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and
the warranty of the unit automatically expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
Ź Observe all governing codes and ordinances.Ź It is the customer’s responsibility to be aware of these below:Ź To contact a qualified electrical installer.Ź To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest
edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes
and ordinances.
Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path
is adequate.
Ź Do not ground to a gas pipe.Ź Check with a qualified electrician if you are not sure the range hood is properly grounded.Ź Do not have a fuse in the neutral or ground circuit.Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected
by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram
on product.
Ź A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and
install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
Federal Communication Commission Interface Statement
Ź This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Ź This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one of the following
measures:
Ź Reorient or relocate the receiving antenna.
Ź Increase the separation between the equipment and receiver.
Ź Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Ź Consult the dealer or an experienced radio/TV technician for help.
Ducting, conduit and all installation tools
Cable locking connector (if required by local codes)
Recirculating kit
RF remote control
Dual blower motor
Tidal I Use, Care, and Installation Guide
7
PRO
Installation Instructions
Ducting Calculation Sheet
Duct pieces
3- 1/ 4” x 10”
Rect.,
straight
6”, 7”, 8”, 10”
Round,
straight
3- 1/ 4” x 10”
Rect. 90
elbow
3- 1/ 4” x 10”
Rect. 45
elbow
3- 1/ 4” x 10”
Rect. 90
flat elbow
7” to 6” or
8” to 7” Round
tapered
reducer
6”, 7“, 8”
Round
in-line
damper
6”, 7”, 8”, 10”
Round,
0
90
elbow
6”, 7”, 8”, 10”
Round,
0
45
elbow
Equivalent number
length x used =
1 Ft. x ( ) =
1 Ft. x ( ) =
15 Ft. x ( ) =
0
9 Ft. x ( ) =
0
24 Ft. x ( ) =
0
25 Ft. x ( ) =
15
Ft. x ( ) =
15 Ft.
9 Ft. x ( ) =
Subtotal column 1 =
x ( ) =
To t a l
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Duct pieces
3- 1/ 4” x 10”
Rect. to
6” round
transition
3- 1/ 4” x 10”
Rect. to
6” round
transition
0
elbow
90
6” round to
3- 1/ 4” x 10”
rect.
transition
6” round to
3- 1/ 4” x 10”
rect.
transition
0
90
elbow
7” round to
3 1/ 4” x 10”
rect.
transition
7” round to
3- 1/ 4” x 10”
rect.
transition
0
elbow
90
3- 1/ 4” x 10”
Rect.
wall cap
with damper
6”, 7”, 8”, 10”
Round, wall
cap with
damper
6”, 7”, 8”, 10”
Round
roof cap
UNDERCABINET
Equivalent number
length x used =
5 Ft. x ( ) =
20 Ft. x ( ) =
1 Ft. x ( ) =
16 Ft. x ( ) =
8 Ft. x ( ) =
23 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
To t a l
TIDAL I
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
8
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 150 equivalent feet.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Ft.
Ft.
Ft.
Tidal I Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
Mounting Height, Clearance, & Ducting
36”
24” min.
34” max.
Tidal I Use, Care, and Installation Guide
9
PRO
Installation Instructions
UNDERCABINET
TIDAL I
Mounting Height, Clearance, & Ducting
A minimum of 8” round duct or 3-1/4” x 10” rectangular duct is recommended to maintain maximum
air flow eciency for single blower and 10” round duct for dual internal blower.
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Also use the ducting calculation sheet (on page 11) to compute total available duct run when using
elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required,
increase duct size from 8” to 10”.
If turns or transitions are required; install as far away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood bottom should be no less than 24”.
Maximum mount height should be no higher than 34”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result
in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its
performance and eciency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood
mounting height above range. Always check your local codes for any dierences.
For shipment and installation damages:
Ź Please fully inspect unit for damage before installation.
Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.
10
Tidal I Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
Ducting Options
WARNING
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
Ź Use single wall rigid metal ductwork only.
Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
Cable Lock
FIG. A
Tidal I Use, Care, and Installation Guide
13
PRO
Installation Instructions
UNDERCABINET
TIDAL I
Horizontal Ducting Conversion
By default the Tidal I is pre-configured for 8” round vertical ducting. These steps are for 8” round and
3-1/4”x10” rectangular horizontal ducting. If you are continuing with vertical ducting, please skip
these steps.
NOTE: Horizontal ducting is only available for the single internal blower.
1. Disconnect blower plug.
2. Remove (4) screws at top of
hood body attaching blower to
blower plate. Remove blower from
interior of hood body.
3. Remove (4) screws from interior
of hood body attaching blower
plate to hood body. Remove
blower plate.
14
Tidal I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Horizontal Ducting Conversion
B
A
Installation Instructions
4. Knock out rear plates B for 8”
round rear ducting or plate A only
for 3-1/4” x 10” rectangular rear
ducting.
5. Place blower inside hood as
shown.
6. Attach blower to hood body
from the back of hood using (4)
previously removed blower screws
and reconnect blower plug.
Tidal I Use, Care, and Installation Guide
15
PRO
Installation Instructions
Horizontal Ducting Conversion
TIDAL I
UNDERCABINET
7. Attach 8” round duct collar or 3
1/4” x 10” rectangular duct collar
to back of hood body using (4)
M3.5 x 8 screws.
8. From inside hood body, position
top cover plate to top of hood
body. From outside hood body,
attach top cover plate to top of
hood body using (4) 3/16” x 3/8”
screws.
16
Tidal I Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
PBD-1300B Dual Blower Installation
This range hood is equipped standard with a single blower vertical duct option. To convert from
single blower vertical ducting to dual blower vertical ducting please following the instructions below.
PBD-1300B dual blower kit compatible only with AK7336AS.
1. Remove the bae filters and
if applicable, remove the side
panels. Disconnect blower plug.
2. Remove (4) screws at top of
hood body attaching blower to
blower plate. Remove blower from
interior of hood body.
3. Remove (4) screws from interior
of hood body attaching blower
plate to hood body. Remove
blower plate.
4. Install dual blower plate from
PBD-1300B kit into hood body.
Attach by (4) screws previously
removed from step 3.
Tidal I Use, Care, and Installation Guide
17
PRO
Installation Instructions
PBD-1300B Dual Blower Installation
5. Install previously removed blower
6. Install blower from PBD-1300B
TIDAL I
UNDERCABINET
onto one side of dual blower plate
and attach by (4) previously
removed screws from step 2.
kit onto other side of dual blower
plate by (4) 3/16 x 3/8 screws.
7. Dual blower screw mount
locations.
8. Remove (4) screws to remove the
light panel. Install dual blower
PCB inside the hood body.
18
Tidal I Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
PBD-1300B Dual Blower Installation
9. Refer to page 32 section for this
10. Place 10” round adapter
step. Connect the wiring from
the dual blower including both
blower plugs, blower cable 6 pin
connector (E), dual blower switch
cable (H), black single pin power
cord from dual blower (K), and
white single pin power cord (F) to
dual blower PCB.
(included with PBD-1300B) on top
of hood and secure with (4) M3.5
x 8 screws.
NOTE: To secure the 10” transition adapter to top of hood a cut out of 14-1/2” width x 10-1/2” depth
will need to be made in the cabinet bottom.
If internal cabinet dimensions prevent this size of a cut out then the 10” transition adapter may be
mounted to the cabinet bottom rather than the top of the hood. Cut out dimensions for this type of
installation are 13-1/4” width x 6-1/4” depth.
Tidal I Use, Care, and Installation Guide
19
PRO
Aluminum duct
tape
Duct
opening/
cutout
Add 1” x 2”
wood strips
Pro bae filters
Electrical
Installation Instructions
UNDERCABINET
TIDAL I
Mounting the Hood
If recirculating range hood refer to the manual included with ZRC-70xxC recirculating kit or on our
website prior to installing hood.
Hood is designed for installation under a kitchen
cabinet.
1. Prepare duct location on hood (vertical or
horizontal).
2. Begin installation by removing the safety screw
on top of hood body and filters. Then remove
side panels by (2) screws.
3. Reinforce cabinet with 1” x 2” wood strips
if additional strengthening is required or if
cabinets are framed.
4. Temporarily position the range hood in the
desired mounting location. Measure and
mark the mounting holes, duct and electrical
locations with a pencil.
5. Drill/cut out the required openings for duct and
electrical access; make sure the duct opening
is large enough to apply duct tape.
9. If using RF remote control, remove the light
panel by (4) screws and extend the blue
antenna wire. There is no need to secure it.
Reinstall light panel.
10. Reinstall the filters and side panels.
FIG. B
11. Power up hood and check for leaks around
duct tape.
20
Tidal I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Proximity Controls
PowerLights
PROXIMITY SENSOR
Ź When approaching the hood while it is powered o, the Power, Fan Decrease, Fan Increase,
and Light icons will illuminate, and “HELLO” will appear on the LCD display for 2 seconds.
Features & Controls
Display & Icons
Adjust 6 Speed Levels
Ź If neither the fan nor lights are turned on within 60 seconds, the icons will turn o, and
“GOODBYE” will appear on the LCD display for 2 seconds.
Ź The icons will not disappear until the fan and lights are turned o.
CONTROL ICONS
Power
Ź Press the power icon to power on or o the fan and lights.
Ź The hood has a memory function to remember the last used settings for the fan and lights.
Ź After pressing the power icon to power o the hood, “GOODBYE” will appear on the LCD
display for 2 seconds.
Ź The 3s icon under the power icon only illuminates when the fan is powered on. It is an
indicator to enable Automatic Delay O by pressing and holding the power button
for 3 seconds.
Decrease Fan Speed
Ź Press the icon to decrease fan speed from 6, 5, 4, 3, 2, 1, o.
Increase Fan Speed
Ź Press the icon to increase fan speed from o, 1, 2, 3, 4, 5, 6.
Lights
Ź Press the lights icon to change lighting level from 1, 2, 3, o.
Tidal I Use, Care, and Installation Guide
21
PRO
Features & Controls
Proximity Controls
DISPLAY ICONS & FUNCTIONS
Ů
Ź The notification bell icon will illuminate when an action needs to be taken. Tapping the
icon will cycle through the notifications. The notification bell will remain illuminated until all
notifications are resolved. The notification bell will not illuminate when the hood and controls
are powered o.
Bluetooth®
Ź The Bluetooth® icon will illuminate the device when connected with the hood via Bluetooth®.
The words “BLUETOOTH CONNECTED” or “BLUETOOTH DISCONNECT” will appear on the
LCD display whenever the connection changes.
Wi-Fi
TIDAL I
UNDERCABINET
Ź The Wi-Fi icon will illuminate when the hood is connected to the Wi-Fi. The words “WIFI
CONNECTED” or “WIFI DISCONNECTED” will appear on the LCD display whenever the
connection changes which will be managed via the Zephyr Connect app.
Ű
Ź While the fan is on, press and hold for 3 seconds to enable the delay o timer. The fan will
change to speed 1, the timer display will illuminate, the LCD display will show “AUTOMATIC
DELAY OFF”, and the timer will begin counting down from 10 minutes. After the timer reaches
0, the fan and lights will power o.
Ź The automatic delay o function timer begins at 10 minutes by default. The Zephyr Connect
app provides the options for either 5 or 10 minutes.
CleanAir
Ź When the fan is o, press and hold and simultaneously for 3 seconds to enable or
disable the CleanAir function. The LCD display will show “CLEAN AIR ENABLED” or “CLEAN
AIR DISABLED”.
Ź When enabled, the fan will turn on speed 1 every 4 hours for 10 minutes. While the fan is
running, the LCD display will show “CLEAN AIR ACTIVE” and the CleanAir icon will illuminate.
22
Tidal I Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Proximity Controls
ĻŮ
Ź Airflow Control Technology (ACT™) allows the installer to set the maximum fan CFM to align
with local codes and regulations. When the fan is o, press and hold
display ACT™ status.
Ź After 60 hours of fan use, the notification bell icon will illuminate. When the bell is tapped,
the LCD display will cycle between showing “CLEAN GREASE FILTERS” and then “HOLD
DOWN TO RESET” every 2 seconds. If no action is taken for 30 seconds, the display turns o
and the notification bell icon will remain illuminated.
Ź To hold down and reset, press and hold the fan decrease button for 3 seconds to
reset. The Zephyr Connect app provides the option to reset the reminder.
Ź Hold and for 3 seconds to enable or disable recirculating mode which will remind you
to replace the charcoal filter. The LCD display will show “RECIRCULATING ENABLED” to
enable and “RECIRCULATING DISABLE” to disable for 2 seconds.
Ź After 200 hours of fan use, the notification bell icon will illuminate. When the bell is tapped,
the LCD display will cycle between showing “REPLACE CHARCOAL FLTR” and “HOLD UP TO
RESET” every 2 seconds. If no action is taken for 30 seconds, the display turns o and the
notification bell will remain illuminated.
Ź To hold up and reset, press and hold the fan increase button for 3 seconds to reset.
The Zephyr Connect app provides the option to reset the reminder.
Remote Control Pairing Mode
Ź Hold for 3 seconds to enable remote control pairing mode. Once pairing mode is enabled,
the LCD display will illuminate “REMOTE PAIRING”. Press a button on the remote control to
synchronize it with the hood.
Tidal I Use, Care, and Installation Guide
23
PRO
Features & Controls
UNDERCABINET
TIDAL I
Zephyr Connect
Your range hood is compatible with our Zephyr Connect app. All you need is a WiFi connection with
access to the Internet that can reach the location of your range hood. Zephyr Connect allows you to
control your range hood from anywhere using a mobile device or your Amazon Alexa or Google Home
smart speaker. Zephyr Connect also includes real time diagnostics and provides you with important
product information.
The Zephyr Connect app is available on iOS devices using iOS 11.0 or later or Android devices using
Android version 8 or later. Visit the Apple App Store or Google Play Store for more information.
If your range hood is not connected to WiFi, the functionality will operate similarly to a typical range
hood without WiFi connectivity.
Please review the included Zephyr Connect Quick Start Guide for more information.
If you have connected your hood with either Amazon Alexa or Google Home smart speakers, you now
have voice control capabilities. The list of commands for Amazon Alexa and Google Home are on the
next page.
NOTE: Amazon Alexa and Google Home cannot support the voice commands in French.
24
Tidal I Use, Care, and Installation Guide