Zep ZUNRS128EA User Manual

SAFETY DATA SHEET
Zep(R) No-Rinse Floor Disinfectant
Version 1.0
Print Date 05/02/2016
Material name
:
Zep(R) No-Rinse Floor Disinfectant
EPA ID Number:
1839-168-40849 Material number
:
ZUNRS128
Company
:
Zep Commercial Sales & Service, a unit of Zep, Inc.
Address
:
1310 Seaboard Industrial Blvd., NW Atlanta, GA 30318
Telephone
:
404-352-1680
Emergency telephone numbers
For SDS Information
:
Compliance Services 1-877-428-9937
For a Medical Emergency
:
877-541-2016 Toll Free - All Calls Recorded
For a Transportation Emergency
:
CHEMTREC: 800-424-9300 - All Calls Recorded. In the District of Columbia 202-483-7616
Appearance
liquid
Colour
yellow
Odour
pleasant
Skin irritation
:
Category 2
Eye irritation
:
Category 2A
Hazard pictograms
:
Signal word
:
Warning
Hazard statements
:
H315 Causes skin irritation. H319 Causes serious eye irritation.
Precautionary statements
:
Prevention: P264 Wash skin thoroughly after handling. P280 Wear eye protection/ face protection. P280 Wear protective gloves.
Response:
P302 + P352 IF ON SKIN: Wash with plenty of soap and water. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Manufacturer or supplier's details
SECTION 2. HAZARDS IDENTIFICATION
Emergency Overview
GHS Classification
GHS Label element
1 / 10
SAFETY DATA SHEET
Zep(R) No-Rinse Floor Disinfectant
Version 1.0
Print Date 05/02/2016
for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P332 + P313 If skin irritation occurs: Get medical advice/ attention. P337 + P313 If eye irritation persists: Get medical advice/ attention. P362 Take off contaminated clothing and wash before reuse.
IARC
No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
ACGIH
No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by ACGIH.
OSHA
No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by OSHA.
NTP
No component of this product present at levels greater than or equal to 0.1% is identified as a known or anticipated carcinogen by NTP.
Substance / Mixture
:
Mixture
Chemical Name
CAS-No.
Concentration [%]
Quaternary ammonium compounds, benzyl-C12­16-alkyldimethyl, chlorides
68424-85-1
>= 1 - < 5 decyldimethyloctylammonium chloride
32426-11-2
>= 0.1 - < 1
General advice
:
Move out of dangerous area. Show this safety data sheet to the doctor in attendance. Do not leave the victim unattended.
If inhaled
:
If unconscious place in recovery position and seek medical advice. If symptoms persist, call a physician.
In case of skin contact
:
If skin irritation persists, call a physician. Wash off immediately with plenty of water for at least 15 minutes. If on clothes, remove clothes.
In case of eye contact
:
Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing.
Potential Health Effects
Carcinogenicity:
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Hazardous components
SECTION 4. FIRST AID MEASURES
2 / 10
SAFETY DATA SHEET
Zep(R) No-Rinse Floor Disinfectant
Version 1.0
Print Date 05/02/2016
If eye irritation persists, consult a specialist. Rinse immediately with plenty of water for at least 15 minutes.
If swallowed
:
Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. DO NOT induce vomiting unless directed to do so by a physician or poison control center.
Suitable extinguishing media
:
Water spray jet Carbon dioxide (CO2) Alcohol-resistant foam Dry chemical
Unsuitable extinguishing media
:
High volume water jet
Specific hazards during firefighting
:
Do not allow run-off from fire fighting to enter drains or water courses.
Hazardous combustion products
:
Carbon dioxide (CO2) Carbon monoxide Smoke
Specific extinguishing methods
:
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Further information
:
Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Special protective equipment for firefighters
:
Wear self-contained breathing apparatus for firefighting if necessary.
Personal precautions, protective equipment and emergency procedures
:
Use personal protective equipment. Ensure adequate ventilation. Evacuate personnel to safe areas.
Environmental precautions
:
Prevent further leakage or spillage if safe to do so. Prevent product from entering drains. If the product contaminates rivers and lakes or drains inform respective authorities.
Methods and materials for containment and cleaning up
:
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.
SECTION 5. FIREFIGHTING MEASURES
SECTION 6. ACCIDENTAL RELEASE MEASURES
3 / 10
Loading...