BZ7355 STN RMVR W/PEROXIDE R00701 6QT/CS
BZ7355 STN RMVR W/PEROXIDE R00701 6QT/CS
1310 Seaboard Industrial Blvd., NW
Atlanta, GA 30318
Telephone
Emergency telephone numbers
Compliance Services 1-877-428-9937
877-541-2016 Toll Free - All Calls Recorded
For a Transportation
Emergency
CHEMTREC: 800-424-9300 - All Calls Recorded.
In the District of Columbia 202-483-7616
H271 May cause fire or explosion; strong oxidiser.
H314 Causes severe skin burns and eye damage.
Prevention:
P210 Keep away from heat.
P220 Keep/Store away from clothing/ combustible materials.
P221 Take any precaution to avoid mixing with combustibles.
P264 Wash skin thoroughly after handling.
P280 Wear protective gloves/ protective clothing/ eye
protection/ face protection.
P283 Wear fire/ flame resistant/ retardant clothing.
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Manufacturer or supplier's details
SECTION 2. HAZARDS IDENTIFICATION
Emergency Overview
GHS Classification
GHS Label element
1 / 11

BZ7355 STN RMVR W/PEROXIDE R00701 6QT/CS
Response:
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT
induce vomiting.
P303 + P361 + P353 IF ON SKIN (or hair): Remove/ Take off
immediately all contaminated clothing. Rinse skin with water/
shower.
P304 + P340 + P310 IF INHALED: Remove victim to fresh air
and keep at rest in a position comfortable for breathing.
Immediately call a POISON CENTER or doctor/ physician.
P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with
water for several minutes. Remove contact lenses, if present
and easy to do. Continue rinsing. Immediately call a POISON
CENTER or doctor/ physician.
P306 + P360 IF ON CLOTHING: rinse immediately
contaminated clothing and skin with plenty of water before
removing clothes.
P363 Wash contaminated clothing before reuse.
P370 + P378 In case of fire: Use dry sand, dry chemical or
alcohol-resistant foam for extinction.
P371 + P380 + P375 In case of major fire and large quantities:
Evacuate area. Fight fire remotely due to the risk of explosion.
Storage:
P405 Store locked up.
Disposal:
P501 Dispose of contents/container in accordance with local
regulation.
No component of this product present at levels greater than or
equal to 0.1% is identified as probable, possible or confirmed
human carcinogen by IARC.
Confirmed animal carcinogen with unknown relevance to
humans
No component of this product present at levels greater than or
equal to 0.1% is identified as a carcinogen or potential
carcinogen by OSHA.
No component of this product present at levels greater than or
equal to 0.1% is identified as a known or anticipated carcinogen
by NTP.
Potential Health Effects
Carcinogenicity:
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Hazardous components
2 / 11

BZ7355 STN RMVR W/PEROXIDE R00701 6QT/CS
Consult a physician.
Show this safety data sheet to the doctor in attendance.
Do not leave the victim unattended.
If unconscious place in recovery position and seek medical
advice.
If symptoms persist, call a physician.
Immediate medical treatment is necessary as untreated
wounds from corrosion of the skin heal slowly and with
difficulty.
If on skin, rinse well with water.
If on clothes, remove clothes.
In the case of contact with eyes, rinse immediately with plenty
of water and seek medical advice.
Remove contact lenses.
Protect unharmed eye.
Keep eye wide open while rinsing.
Keep respiratory tract clear.
Do NOT induce vomiting.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
If symptoms persist, call a physician.
Suitable extinguishing media
Alcohol-resistant foam
Carbon dioxide (CO2)
Dry chemical
Unsuitable extinguishing
media
Hazardous combustion
products
Carbon dioxide (CO2)
Carbon monoxide
Specific extinguishing
methods
Use extinguishing measures that are appropriate to local
circumstances and the surrounding environment.
Collect contaminated fire extinguishing water separately. This
must not be discharged into drains.
Fire residues and contaminated fire extinguishing water must
be disposed of in accordance with local regulations.
For safety reasons in case of fire, cans should be stored
separately in closed containments.
Use a water spray to cool fully closed containers.
Special protective equipment
for firefighters
Wear self-contained breathing apparatus for firefighting if
necessary.
SECTION 4. FIRST AID MEASURES
SECTION 5. FIREFIGHTING MEASURES
3 / 11

BZ7355 STN RMVR W/PEROXIDE R00701 6QT/CS
Personal precautions,
protective equipment and
emergency procedures
Use personal protective equipment.
Evacuate personnel to safe areas.
Environmental precautions
Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform
respective authorities.
Methods and materials for
containment and cleaning up
Contain spillage, and then collect with non-combustible
absorbent material, (e.g. sand, earth, diatomaceous earth,
vermiculite) and place in container for disposal according to
local / national regulations (see section 13).
Do not breathe vapours/dust.
Avoid contact with skin and eyes.
For personal protection see section 8.
Smoking, eating and drinking should be prohibited in the
application area.
To avoid spills during handling keep bottle on a metal tray.
Dispose of rinse water in accordance with local and national
regulations.
Conditions for safe storage
Prevent unauthorized access.
Keep container tightly closed in a dry and well-ventilated
place.
Containers which are opened must be carefully resealed and
kept upright to prevent leakage.
Observe label precautions.
Electrical installations / working materials must comply with
the technological safety standards.
Oxidizing agents
Do not freeze.
Value type
(Form of
exposure)
Control
parameters /
Permissible
concentration
SECTION 6. ACCIDENTAL RELEASE MEASURES
SECTION 7. HANDLING AND STORAGE
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters