SAFETY DATA SHEET
A07297 ZEP FOAMING COIL 020201 NI 20N18
Version 3.0
Print Date 02/15/2021
Material name
:
A07297 ZEP FOAMING COIL 020201 NI 20N18 Material number
:
000000000000020201
Company
:
Zep Inc.
Address
:
350 Joe Frank Harris Parkway, SE Emerson, GA 30137 Telephone
:
404-352-1680
Emergency telephone numbers
For SDS Information
:
Compliance Services 1-877-428-9937
For a Medical Emergency
:
877-541-2016 Toll Free - All Calls Recorded
For a Transportation Emergency
:
CHEMTREC: 800-424-9300 - All Calls Recorded. In the District of Columbia 202-483-7616
Recommended use
:
Specialty Cleaner and Remover Appearance
Aerosol containing a liquefied gas
Colour
colourless, clear
Odour
characteristic
Gases under pressure
:
Liquefied gas
Skin corrosion
:
Category 1
Serious eye damage
:
Category 1
Hazard pictograms
:
Signal word
:
Danger
Hazard statements
:
H280 Contains gas under pressure; may explode if heated. H314 Causes severe skin burns and eye damage.
Precautionary statements
:
Prevention: P260 Do not breathe dust or mist. P264 Wash skin thoroughly after handling. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Manufacturer or supplier's details
Recommended use of the chemical and restrictions on use
SECTION 2. HAZARDS IDENTIFICATION
Emergency Overview
GHS Classification
GHS label elements
1 / 11
SAFETY DATA SHEET
A07297 ZEP FOAMING COIL 020201 NI 20N18
Version 3.0
Print Date 02/15/2021
P251 Pressurized container: Do not pierce or burn, even after use.
Response:
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water. P304 + P340 + P310 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor. P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor. P363 Wash contaminated clothing before reuse. Storage: P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122 °F. P403 Store in a well-ventilated place. Disposal: P501 Dispose of contents/container in accordance with local regulation. Substance / Mixture
:
Mixture
Chemical name
CAS-No.
Concentration [%]
1-(1-methyl-2-propoxyethoxy)propan-2-ol
29911-27-1
>= 3 - < 5
butane
106-97-8
>= 3 - < 5
propane-1,2-diol
57-55-6
>= 1 - < 3
propane
74-98-6
>= 1 - < 3
General advice
:
Do not leave the victim unattended. Move out of dangerous area. Show this safety data sheet to the doctor in attendance.
If inhaled
:
If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
In case of skin contact
:
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
In case of eye contact
:
Remove contact lenses. Rinse immediately with plenty of water for at least 15 minutes.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Hazardous components
The exact percentages of disclosed substances are withheld as trade secrets.
SECTION 4. FIRST AID MEASURES
2 / 11
SAFETY DATA SHEET
A07297 ZEP FOAMING COIL 020201 NI 20N18
Version 3.0
Print Date 02/15/2021
Keep eye wide open while rinsing.
If swallowed
:
Keep respiratory tract clear. Never give anything by mouth to an unconscious person. DO NOT induce vomiting unless directed to do so by a physician or poison control center.
Most important symptoms and effects, both acute and delayed
:
Effects are immediate and delayed. Effects are dependent on exposure (dose, concentration, contact time). Symptoms may include blistering, irritation, burns, and pain. Causes severe skin burns and eye damage. Review section 2 of SDS to see all potential hazards.
Notes to physician
:
Treat symptomatically. Symptoms may be delayed.
Suitable extinguishing media
:
Alcohol-resistant foam Carbon dioxide (CO2) Dry chemical
Unsuitable extinguishing media
:
High volume water jet
Specific hazards during firefighting
:
Do not allow run-off from fire fighting to enter drains or water courses.
Hazardous combustion products
:
Carbon dioxide (CO2) Carbon monoxide Smoke
Specific extinguishing methods
:
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Further information
:
Standard procedure for chemical fires.
Special protective equipment for firefighters
:
Wear self-contained breathing apparatus for firefighting if necessary.
Personal precautions, protective equipment and emergency procedures
:
Use personal protective equipment. Ensure adequate ventilation. Remove all sources of ignition. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
Environmental precautions
:
Prevent further leakage or spillage if safe to do so. Prevent product from entering drains. If the product contaminates rivers and lakes or drains inform respective authorities. Methods and materials for
:
Soak up with inert absorbent material (e.g. sand, silica gel,
SECTION 5. FIREFIGHTING MEASURES
SECTION 6. ACCIDENTAL RELEASE MEASURES
3 / 11
SAFETY DATA SHEET
A07297 ZEP FOAMING COIL 020201 NI 20N18
Version 3.0
Print Date 02/15/2021
containment and cleaning up
acid binder, universal binder, sawdust). Sweep up or vacuum up spillage and collect in suitable container for disposal.
Advice on safe handling
:
For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. Take precautionary measures against static discharges. Provide sufficient air exchange and/or exhaust in work rooms. Always replace cap after use. Do not breathe vapours or spray mist.
Conditions for safe storage
:
BEWARE: Aerosol is pressurized. Keep away from direct sun exposure and temperatures over 50 °C. Do not open by force or throw into fire even after use. Do not spray on flames or red-hot objects. Keep in a dry, cool and well-ventilated place. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards. No smoking.
Materials to avoid
:
Do not freeze. Store and keep away from, oxidizing agents and acids.
Components
CAS-No.
Value type (Form of exposure)
Control parameters / Permissible concentration
Basis butane
106-97-8
TWA
800 ppm 1,900 mg/m3
NIOSH REL
TWA
800 ppm 1,900 mg/m3
OSHA P0
PEL
800 ppm 1,900 mg/m3
CAL PEL propane-1,2-diol
57-55-6
TWA
10 mg/m3
US WEEL
propane
74-98-6
TWA
1,000 ppm
ACGIH
TWA
1,000 ppm 1,800 mg/m3
NIOSH REL
TWA
1,000 ppm 1,800 mg/m3
OSHA Z-1 TWA
1,000 ppm
OSHA P0
SECTION 7. HANDLING AND STORAGE
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION