1600W Power Supplies and Battery Chargers
ZAT1600 SERIES
TASHEET
/ OPERATING INSTRUCTIONS
Wide output adjustment range 0…72VDC
Analog control by external 0-5VDC voltage
Temp.comp charging, sense as on option
Power fail relay alarm
Master-Slave connection
Analog control
modular connector
Microprocessor controlled charging curves for all kind of batteries
Master-Slave
connection
©We reserve the right to change the specification without
AC/DC
zentro-elektrik
GmbH KG | Tel.: +49
(0)
72 32 / 3131 0 | Fax: +49
(0)
72 32 / 3131 399 | E-mail: info@zentro-elektrik.de
DATASHEET
/ OPERATING INSTRUCTIONS
POWER SUPPLIES AND BATTERY CHARGERS, TRIMMER ADJUSTABLE
Type
Input voltage range
**)
Nominal output voltage
Voltage setting range
Nominal output current
Current setting range
Max power
Installation / dimensions
(Width x Height x Depth, mm)
ZAT1600/24/60/_/
55-264VAC/78-340VDC
24 VDC
0-36 VDC
60 A
0-60 A
1600W
Wall//Bench 267x135x85
ZAT1600/36/45/_/
55-264VAC/78-340VDC
36 VDC
0-54 VDC
40 A
0-40 A
1600W
Wall//Bench 267x135x85
ZAT1600/48/30/_/
55-264VAC/78-340VDC
48 VDC
0-72 VDC
30 A
0-30 A
1600W
Wall//Bench 267x135x85
ANALOG CONTROLLABLE MODELS BY EXTERNAL 0-5VDC VOLTAGE
Type
*)
Input voltage range
**)
Nominal output voltage
Voltage setting range
Nominal output current
Current setting Range
Max power
Installation /
dimensions
(Width x Height x Depth, mm)
ZAT1600/24/60/AI/
55-264VAC/78-340VDC
24 VDC
0-36 VDC
60 A
0-60 A
1600W
Wall//Bench 267x135x85
ZAT1600/36/45/AI/
55-264VAC/78-340VDC
36 VDC
0-54 VDC
40 A
0-40 A
1600W
Wall//Bench 267x135x85
ZAT1600/48/30/AI/
55-264VAC/78-340VDC
48 VDC
0-72 VDC
30 A
0-30 A
1600W
Wall//Bench 267x135x85
BATTERY CHARGERS WITH TEMPERATURE COMPENSATION
Type *)
Input voltage range **)
Output voltage factory setting
Programmed output voltages
(see table)
Output current
(see table)
Max power
Installation /
dimensions
(Width x Height x Depth, mm)
ZAT1600/27,4/60/T/
55-264VAC/78-340VDC
27.4 VDC
5…36VDC
60 A
1600W
Wall//Bench 267x135x85
ZAT1600/41,1/45/T/
55-264VAC/78-340VDC
41.1 VDC
12…54VDC
40 A
1600W
Wall//Bench 267x135x85
ZAT1600/54,8/30/T/
55-264VAC/78-340VDC
54.8 VDC
24…72VDC
30 A
1600W
Wall//Bench 267x135x85
*) Cable sets with modular connectors are included in packing: 1.5m cable set for analog control and 2.5m for or temp.comp models **) Reduced power 55…200VAC or 78…200VDC, see curves at next page
MODELS WITH POWER FAIL RELAY ALARM (24V models as a type number example)
Type
Option description
Cable set
ZAT1600/24/60/H
Trimmer adjustable model with power fail relay alarm
1.5 m, modular connector
ZAT1600/24/60/AIH
Analog controllable model with power fail relay alarm
Analog 1.5m + relay cables 1.5m
ZAT1600/24/60/TH
Temp.comp model with Power fail relay alarm
Temp.comp 2.5m + relay cables 1.5m
MASTER-SLAVE CONNECTION (24V models as a type number example)
Master units ***)
Slave units
ZAT1600/24/60 or ZAT1600/24/60 AI or ZAT1600/27,4/60 T Control to slave via RS-232 bus
ZAT1600/24/60 S RS-232 control bus in and out
ZAT1600/24/60 SH slave unit with relay, RS-232 bus in only
Cable set for master slave connection is included in slave unit type number, length 0.6m modular connectors in both ends
***) Master unit or slave with RS-232 bus output can not include the relay alarm
CUSTOMISED VERSIONS ON
Cyclic battery chargers or customzed charging curves for all kind of batteries
Sense models
Customised mechanics
©We reserve the right to change the specification without
AC/DC
zentro-elektrik
GmbH KG | Tel.: +49
(0)
72 32 / 3131 0 | Fax: +49
(0)
72 32 / 3131 399 | E-mail: info@zentro-elektrik.de
Status LED indication
Standard models
Orange Power OK LED
Cyclic chargers
Three color LED, red-yellow-green
Isolations
Input - chassis
1500VAC
Input - output
3750VAC
Output - chassis
500VAC
Standards
Safety
EN60335-2-29 +A2
EMC
EN55022B, EN50081-1, EN50082-2
Approvals
CE marking
Protection class
Mechanical
IP20 metal enclosure
Electrical
Class I
Connectors
Input
Output
Input power cord
10 m
2
2m output cables
Dimensions
l x w x h
267 x 135 x 85 mm with rubber ends
Weight
1,9kg without output cables
Mounting
Wall, bench
Cooling
Temperature controlled fan
Operating temperature range
Full power typically
-25ºC...+40ºC
Reduced power
+40…+ 70ºC, see curve below
Humidity
0…95%, non condensing
DATASHEET
/ OPERATING INSTRUCTIONS
TECHNICAL DATA
Input voltage 50…260 VAC (50…200VAC reduced power, see curve below)
50…340 VDC (50…200VDC reduced power) Input current 9 A Power factor >0.99 Efficiency (230VAC, 10…100% load) > 88% Inrush current <30A, cold start Line regulation 0.01% Load regulation 0.2V Output setting accuracy ± 0.1% Output ripple (f > 50Hz) <30mVrms Hold up time > 5ms
Nominal output voltage / current characteristics 1600W models