Zennio BIN 44, BIN 4x, ZIO-BIN44, ZIO-BIN4x, ZIO-BIN2x User Manual

...
Universal Interface with Binary Inputs
and/or LED Lighting & Electronic Relay Outputs
ZIO-BIN44 ZIO-BIN4X ZIO-BIN2X
USER MANUAL
Application program version: [1.1], [1.2]
User manual edition: [1.2]_a
www.zennio.com
BIN 44 / 4X / 2X
http://www.zennio.com Technical Support: http://support.zennio.com
2
CONTENTS
Contents ........................................................................................................................................ 2
Document updates ........................................................................................................................ 3
1 Introduction .......................................................................................................................... 4
1.1 BIN .................................................................................................................................... 4
1.1.1 BIN 44 ....................................................................................................................... 4
1.1.2 BIN 4X ....................................................................................................................... 4
1.1.3 BIN 2X ....................................................................................................................... 5
1.2 Installation ........................................................................................................................ 6
2 Configuration......................................................................................................................... 8
2.1 General ............................................................................................................................. 8
2.2 Inputs / Outputs ............................................................................................................. 10
2.2.1 BIN 44 ..................................................................................................................... 10
2.2.2 BIN 4X / 2X ............................................................................................................. 10
2.2.3 Binary Input ............................................................................................................ 10
2.2.4 LED Lighting Output ............................................................................................... 10
2.2.5 Electronic Relay Control (Heating Actuator) .......................................................... 14
ANNEX I. Communication Objects............................................................................................... 15
BIN 44 / 4X / 2X
http://www.zennio.com Technical Support: http://support.zennio.com
3
DOCUMENT UPDATES
Version
Changes
Page(s)
[1.1]_a
Application program changes:
Optimisation of the binary inputs, electronic relay control and heartbeat module.
-
Minor text changes.
-
BIN 44 / 4X / 2X
http://www.zennio.com Technical Support: http://support.zennio.com
4
1 INTRODUCTION
1.1 BIN
The BIN product family from Zennio consists of a variety of small-size KNX interfaces, designed to be installed, for instance, inside electric appliance boxes. They allow connecting a variable number of binary inputs (pushbuttons, switches) while they also provide LED and electronic relay control outputs (up to 12V DC, 2 mA). Therefore, the same device is able to provide feedback to the LED indicators incorporated by many pushbuttons and switches or to operate low-current relays (e.g., heating system relays).
The BIN product family also incorporates the Heartbeat function, which consists in sending a periodical “still-alive” notification to the KNX bus.
The number of input and output channels depends on each specific model, being fixed in some of them or configurable by the integrator in those models where a sole channel can work either as an input or as an output:
1.1.1 BIN 44
4 fixed inputs, configurable as:
Binary inputs.
4 fixed outputs, configurable as:
LED lighting outputs. Electronic relay control outputs (heating actuators).
1.1.2 BIN 4X
4 input / output channels, freely configurable as:
Binary inputs. LED Lighting Output. Electronic Relay Control (Heating Actuator).
BIN 44 / 4X / 2X
http://www.zennio.com Technical Support: http://support.zennio.com
5
1.1.3 BIN 2X
2 input / output channels, freely configurable as:
Binary inputs. LED Lighting Output. Electronic Relay Control (Heating Actuator).
BIN 44 / 4X / 2X
http://www.zennio.com Technical Support: http://support.zennio.com
6
1.2 INSTALLATION
BIN is connected to the KNX bus through the incorporated terminal connector, while the input lines are connected to BIN through a screw terminal block, bundled with the stripped cables already connected.
Once the device is provided with power from the KNX bus, both the individual address and the associated application program may be downloaded.
This device does not need any additional external power since it is entirely powered through the KNX bus.
Figure 1. Element diagram.
The main elements are described next:
Prog./Test Button (2): a short press on this button sets the device into the
programming mode, making the associated LED (3) light in red. If this button is held at the same time of applying bus power to the device, BIN will enter the Safe Mode. In such case, the LED will intermit in red.
Slots for the input / output lines: slot for the insertion of the terminal block
with cables (see Figure 2) that permits BIN interfacing with the different input and output elements.
Figure 2. Input / output terminal block
1.- Slots for the input / output channels
2.- Programming button
3.- Programming LED
4.- KNX
3 2 4
1
Loading...