Zennio RailQUAD 8, ZIO-RQUAD8 User Manual

Analogue/Digital Multifunction Input Module
for DIN rail
ZIO-RQUAD8
USER MANUAL
Application program version: [1.3], [1.4]
User manual edition: [1.4]_a
www.zennio.com
RailQUAD 8
http://www.zennio.com Technical Support: http://support.zennio.com
2
CONTENTS
Contents ........................................................................................................................................ 2
Document Updates ....................................................................................................................... 3
1 Introduction .......................................................................................................................... 4
1.1 RailQUAD 8 ....................................................................................................................... 4
1.2 Installation ........................................................................................................................ 5
2 Configuration......................................................................................................................... 7
2.1 General ............................................................................................................................. 7
2.2 Inputs ............................................................................................................................... 8
2.2.1 Binary Input .............................................................................................................. 9
2.2.2 Temperature Probe .................................................................................................. 9
2.2.3 Motion Detector ...................................................................................................... 9
2.3 Thermostats ................................................................................................................... 10
ANNEX I. Communication Objects............................................................................................... 11
RailQUAD 8
http://www.zennio.com Technical Support: http://support.zennio.com
3
DOCUMENT UPDATES
Version
Changes
Page(s)
[1.3]_a
Changes in the application program:
Optimisation of inputs, thermostat and heartbeat modules.
-
Minor text changes.
-
[1.2]_a
Changes in the application program:
Optimisation of the binary inputs, motion detector and thermostat modules.
-
[1.1]_a
Changes in the application program:
Support for custom NTC probes.
Heartbeat functionality added.
-
RailQUAD 8
http://www.zennio.com Technical Support: http://support.zennio.com
4
1 INTRODUCTION
1.1 RailQUAD 8
RailQUAD 8 is an analogue / digital input module from Zennio featuring eight separate inputs, each configurable as:
Binary Input.
Temperature probe, either models provided by Zennio or other NTC
temperature probes from other suppliers, being in that case possible to configure their parameters in ETS.
Motion detector.
Moreover, RailQUAD 8 implements:
8 independent thermostats, which can be enabled and configured
separately.
Heartbeat or periodical “still-alive” notification.
In sum, RailQUAD 8 is an updated version of the popular QUAD from Zennio, with twice the number of inputs and intended to be installed on a DIN rail
RailQUAD 8
http://www.zennio.com Technical Support: http://support.zennio.com
5
1.2 INSTALLATION
RailQUAD 8 is connected to the KNX bus through the incorporated terminal connector.
Once powered through the KNX bus, the device may be downloaded both, an individual address or the application program.
This device does not need any additional external power since it is entirely powered through the KNX bus.
Figure 1 RailQUAD 8. Element diagram.
The main elements are described next:
Prog./Test Pushbutton (5): a short press on this button sets the device into
the programming mode, making the associated LED (4) light in red.
Note: if this button is held while plugging the device into the KNX bus, the device will enter into safe mode. In such case, the LED will blink in red every
0.5 seconds.
Inputs (1)(3): input ports for the insertion of the stripped cables of external
elements such as switches / motion detectors / temperature probes, etc. One of the two cables of each element needs to be connected to one of the slots
labelled “1” to “8”, while the other cable should be connected to the slot
labelled as “C”. Note that all the external input devices share the “C” slot for
one of the two cables. Please secure the connection by means of the on­board screws.
1. Analogue/digital inputs 1 to 4
2. KNX bus connector
3. Analogue/digital inputs 5 to 8
4. Prog./Test LED
5. Prog./Test button
1
2
3
4
5
1 2 34 5
RailQUAD 8
http://www.zennio.com Technical Support: http://support.zennio.com
6
To obtain further information about the technical features of RailQUAD 8 and on security and installation procedures, please refer to the Datasheet of the device, bundled with the original packaging and also available at the Zennio website,
http://www.zennio.com.
Loading...
+ 12 hidden pages