Zennio KLIC-DA LT User Manual

KLIC-DA LT
ZN1CL-KLIC-DA
USER MANUAL
Application Program Version: [2.2]
User Manual Version: [2.2]_a
www.zennio.com
KLIC-DA LT
http://www.zennio.com Technical Support: http://support.zennio.com
2
CONTENTS
Contents ........................................................................................................................................ 2
Document Updates ....................................................................................................................... 3
1 Introduction .......................................................................................................................... 4
1.1 KLIC-DA .......................................................................................................................... 4
1.1.1 KLIC-DA LT ............................................................................................................. 5
1.2 Installation ..................................................................................................................... 6
2 Configuration......................................................................................................................... 8
2.1 Domestic Hot Water Management (DHW) ................................................................... 8
2.2 Climate control management ....................................................................................... 8
2.3 Error Handling ............................................................................................................... 8
2.4 Additional Indicators ..................................................................................................... 9
2.5 Start-up.......................................................................................................................... 9
3 ETS Parameterisation .......................................................................................................... 11
3.1 Default Configuration .................................................................................................. 11
3.1.1 Configuration ....................................................................................................... 12
3.1.1.1 Domestic Hot Water ........................................................................................ 14
3.1.1.2 Climate ............................................................................................................ 15
3.1.1.3 Error Handling ................................................................................................. 17
3.1.1.4 Temperatures (Status) ..................................................................................... 18
3.1.1.5 Actuators (Status) ............................................................................................ 18
3.1.1.6 Energy (Status) ................................................................................................ 19
3.1.1.7 Additional Information (Status) ...................................................................... 20
ANNEX I. Communication Objects............................................................................................... 21
KLIC-DA LT
http://www.zennio.com Technical Support: http://support.zennio.com
3
DOCUMENT UPDATES
Version
Changes
Page(s)
[2.2]_a
Changes in the application program:
New object to notify malfunction code.
-
New object to notify malfunction code.
17
Remark about measurements in the event of malfunction.
17
Remark about energy values updating.
20
[2.1]_a
Changes in the application program:
Code optimisation.
-
[2.0]_a
Changes in the application program:
Compatibility with newer (CB) models of the
Altherma LT system.
Possibility of configuring a minimum period between
transmissions of the status objects.
New energy consumption / production objects per
circuit (only in CB systems).
-
[1.4]_a
Changes in the application program:
Code optimisation.
-
[1.3]_a
Changes in the application program:
Improvement in the interoperability with the Altherma
LT system clock.
-
[1.2]_a
Changes in the application program:
Compatibility with additional Altherma LT systems.
-
[1.1]_a
Changes in the application program:
Internal optimisation of the ETS project.
-
KLIC-DA LT
http://www.zennio.com Technical Support: http://support.zennio.com
4
1 INTRODUCTION
1.1 KLIC-DA
KLIC-DA from Zennio is the ideal solution for the integration of Altherma climate systems into a KNX domotic environment.
As a bidirectional KNX / Altherma interface, KLIC-DA provides full communication between any KNX device (e.g., the InZennio Z41 touch screen from Zennio) and the Altherma system, which can therefore be controlled analogously as from the specific Altherma user interfaces. Moreover, any status updates and feedback received from the Altherma system will also be forwarded by KLIC-DA towards other KNX devices.
Figure 1. KLIC-DA
Daikin Altherma is an integral solution for climate control. Although mainly based on the heat pump technology, Altherma systems can optionally perform cooling as well, therefore providing the user with heating, air-conditioning and domestic hot water.
Depending on the structure of the system (e.g.: location of the external unit, integration or not of the hydrobox within the same unit, etc.) and on whether A/C is required or not, different Altherma systems are available.
KLIC-DA LT
http://www.zennio.com Technical Support: http://support.zennio.com
5
1.1.1 KLIC-DA LT
The KLIC-DA LT application program provided by Zennio focuses on controlling
Altherma LT (from Low Temperature) systems, in contrast to the Altherma HT (from High Temperature) systems.
An Altherma LT system consists of a series of elements (an external unit, a hydrobox, an internal unit, the user interfaces, etc.), and the specific “P1/P2” communication bus, which allows the user interfaces (typically, one acting as the main control and the other as an additional control) communicate to each other and to the Altherma LT system.
KLIC DA LT is compatible with models CA and CB of Altherma LT system hidrokit.
Note: only the main interface interacts with the Altherma LT system. Any order from or to the additional interface will reach the main interface too.
KLIC-DA LT is meant to replace the aforementioned additional interface, and thus to communicate only to the main interface and not to the Altherma LT system directly.
The main functions performed by the KLIC-DA LT application program are:
Management of the domestic hot-water (DHW) system.
Management of the room climate system (Leaving Water Method).
Error handling.
Simultaneous monitoring of multiple indicators (temperature setpoints,
actuator states, sensors…) reported by the Altherma LT system.
On the other hand, Altherma LT systems feature three climate control methods:
Control of the leaving water temperature (LWT),
Control through a user interface configured as a thermostat,
Control though an external thermostat (TH).
The KLIC-DA LT application program is only compatible with Altherma LT systems configured for an LWT control, and with only one climate zone (Altherma LT systems permit up to two climate zones with independent setpoint temperatures).
KLIC-DA LT
http://www.zennio.com Technical Support: http://support.zennio.com
6
1.2 INSTALLATION
Figure 2. Element Diagram
KLIC-DA connects to the KNX bus via the corresponding built-in terminals (1). On the other hand, this device needs to be connected to the P1/P2 bus of the Altherma system (4) in substitution of the original additional user interface.
Once the device is being powered from the KNX bus, both the physical address and the KLIC-DA LT application program can be downloaded.
This device does not need any additional external power as it is entirely powered through the KNX bus.
The functionality of the remaining elements is as follows:
Programming Button (3): a short press on this button will set the device into
the programming mode, making the red component of the LED (2) indicator light up. If the button is held while plugging the device into the KNX bus, KLIC-DA will go into the safe mode, making the red colour of the LED blink intermittently.
LED Indicator (2): this three-colour (red, blue and green) light indicator
reflects the current state of the device. Apart from showing whether the device is under the programming or safe modes, this LED will also react to any communication between KLIC-DA and the P1/P2 bus, which may be useful during the installation process. The meaning of the different colour components is explained next:
1.- KNX Connector
2.- Programming LED
3.- Programming Button
4.- Two-wire Communication Terminal
1 3 4
2
KLIC-DA LT
http://www.zennio.com Technical Support: http://support.zennio.com
7
Red Component (still): KLIC-DA is under the programming mode.
Red Component (blinking): KLIC-DA is under the safe mode.
Green Component (still): KLIC-DA is not connected to the Altherma
system, or the latter is disconnected from the power supply.
Green Component (blinking): transmission or data from the P1/P2 bus
towards KLIC-DA.
Blue Component (blinking): transmission or data from KLIC-DA
towards the P1/P2 bus.
Note: each colour component works with independence of the others. Therefore, if for instance KLIC-DA is under the programming mode being the Altherma system disconnected, the effective colour will be orange (still), as the red and green components will be lighting (still).
Input Terminal for the Two-Wire Communication Cable (4): slot for the
connection of the two-wire communication cable that will connect KLIC-DA to the Altherma P1/P2 bus.
Figure 3. Connection to the P1/P2 bus
As stated in 1.1.1 and shown in Figure 3, KLIC-DA needs to be installed in substitution of the original additional user control, while the main user control needs to be configured as “At Unit under “User Interface Location.
For detailed information about the technical features of KLIC-DA, as well as on security and installation procedures, please refer to the device Datasheet, bundled within the original packaging of the device and also available at http://www.zennio.com.
A. Hydrobox Unit. B. Main User Interface. C. KLIC-DA.