Zenith Heaters BC100/75 User Manual

®
Zenith HydroTap G4
User Guide
Tap Operation .................. Pages 3-10
LCD Screen & Menu ....... Pages 11-23
Maintenance .................... Pages 24-25
Home Menu Icons ........... Page 26
Cleaning ........................... Page 27
Contact Details ................ Page 28
Date of Installation............../.........../..........
HydroTap BC100/75 HydroTap BC160/125 HydroTap BC160/175 HydroTap BC240/175
HydroTap Residential
Affix Model Number
Label Here
802254NZ - HT BC User Guide 10.18 v3.02 Page 1 of 28
** This user manual has been written according to firmware version B02.6.8 Please check the following website for the latest user manual:
zenithwater.co.nz
BC Residential BC100/75
BC160/125 BC160/175 BC240/175
Page 2 of 28 802254NZ - HT BC User Guide 10.18 v3.02
Tap Safety Lock
The safety lock feature is provided to prevent boiling water flowing if the hot lever is inadvertently operated. This function can be activated and deactivated from either the Tap or from the touch screen display (Located on the unit in the cupboard).
To set the tap safety setting: (Classic & Elite)
1. Press [MENU] button for main menu.
2. Press [Setting] button.
3. Press [Safety] button.
4. Press button -YES / NO to allow or disallow the safety setting to be changed on the tap.
Note: The Factory setting is set at YES
A
HydroTap Classic
To activate the safety for Classic & Elite taps
(From the tap):
After selecting to allow the safety setting from the menu screen. Place a finger on the safety lock, then depress the Classic Blue/Chilled lever or touch the Elite Blue/ Chilled Button, while keeping both fingers in position for a period of approximately ten seconds.The Classic safety lock indicator light will now be illuminated or the Elite lights will flash, momentarily.
A
B
C
To deactivate the safety
(From the tap):
First place a finger on the safety lock, then depress the Classic Blue/Chilled lever or touch the Elite Blue/Chilled Button, while keeping both fingers in position for a period of approximately ten seconds. The Classic safety lock indicator light will now extinguish or the Elite lights will flash, momentarily.
Safety Lock
For Hot Isolation:
Not for HydroTap Arc/Cube and Celsius AIO (see page 20).
802254NZ - HT BC User Guide 10.18 v3.02 Page 3 of 28
Elite Tap
Tap functions
Classic Tap:
The Classic tap uses lever control to dispense Boiling and Chilled water.
The safety lock can be controlled from either the tap or from the touch screen display (see page 3).
Elite Tap:
The Elite tap uses touch sensitive controls to dispense Boiling and Chilled water.
When operating the tap, ensure the touch surface is dry as mois­ture may interfere with the sensor touch control.
The safety lock can be controlled from either the tap or from the touch screen display (see page 3)
Boiling Button Chilled Button
Safety Lock
Boiling Button Chilled Button
Safety Lock
Page 4 of 28 802254NZ - HT BC User Guide 10.18 v3.02
Tap functions
Celsius All-In-One Tap:
The Celsius AIO combines the tap functions of the Arc/Cube tap and the Classic Mixer tap. Please see AIO tap and Arc/Cube tap functions for the Celsius AIO.
Classic All-In-One Tap:
The top levers and safety lock button of the Classic AIO tap are operated in the same way as a Classic HydroTap to dispense Boiling and Chilled water.
The Mixer tap lever is operated as a classic ‘Flick Mixer’. The hot side is marked with a red mark and the cold side with a blue mark, for dispensing cold to warm water.
Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Lift the handle all the way up to turn the tap off.
When the handle is moved towards the blue mark, the temperature is decreased and when moved towards the red mark, the temperature is increased. The final temperature will be dependant on the temperature of the incoming cold water.
For convenience, the spout may be swivelled, left or right through 120°.
802254NZ - HT BC User Guide 10.18 v3.02 Page 5 of 28
Tap functions
HydroTap Arc/Cube and Celsius AIO:
Tapping the select button will allow the choice of Boiling (RED) with safety, Chilled (BLUE) or Sparkling (WHITE) water mode. The Arc/Cube control may be rotated in a forward or reverse direction to dispense Boiling or Chilled water.
The rotary control is spring load­ed in the anticlockwise direction and when released, will return to the OFF position. When rotated clockwise the tap operates in a “Pot fill” mode. Water will flow from between 5 and 15 seconds (this is user adjustable). To reset, return the handle to the “Off” position and repeat the step. The lever has to be manually returned to the “Off” position. After activating the Boiling mode, all the lights will flash for 2 seconds, during which time you may dispense water. When the rotary control is returned to the Off position the light will continue to flash for an additional 3 seconds, allowing you to dispense more water.
The control light will automatically default to the Chilled (BLUE) mode after 30 seconds of inactivity.
Rotary control
Select Button
Safety Lock
Mixer Tap:
Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Raise the handle all the way up to turn the tap off.
When the handle is moved towards the BLUE mark, the temperature is decreased and when moved towards the RED mark, the temperature is increased. The final temperature will depend on the temperature of the incoming cold water.
Page 6 of 28 802254NZ - HT BC User Guide 10.18 v3.02
Tap operation
To dispense Chilled water:
HydroTap Classic and Classic All-In-One taps
Depress the “Blue” lever to dispense Chilled water. Pulling forward the Blue lever allows the tap to operate in a “no-touch” mode. Water will flow from between 5 and 15 seconds (this is user adjustable). To reset, return the handle to the “Off” position and repeat the step. The lever has to be manually returned to the “Off” position.
NOTE:
Chilled water will not be dispensed if the safety button is accidentally covered.
Elite Tap
Touch the Chilled button to dispense Chilled water.
Press or pull lever
Classic Tap
Elite Tap
HydroTap Arc/Cube and Celsius AIO
If not showing BLUE, gently tap the select button until the indicator light turns BLUE.
Rotating the control, when the indicator light is BLUE, allows the dispensing of chilled water.
802254NZ - HT BC User Guide 10.18 v3.02 Page 7 of 28
Indicator
light
Select button
Arc/Cube Tap
Tap operation
To dispense Boiling water: (WITH SAFETY ON)
HydroTap Classic:
Depress the Red lever, while simultaneously covering the safety lock button with a second finger. These two actions need to occur simultaneously within 2 seconds for the successful dispensing of boiling water.
Elite Tap:
Place one finger on the safety lock, then touch the boiling button with a second finger while keeping both fingers in position.
These two actions need to occur simultaneously within 2 seconds for the successful dispensing of boiling water.
HydroTap Arc/Cube and Celsius AIO:
Gently tap the select button until the indicator light turns RED. Then tap the safety button twice until the RED light flashes (This will flash for approx 2 seconds). Boiling water may be dispensed by rotating the control while the RED light is flashing.
To dispense Boiling water: (WITH SAFETY OFF)
HydroTap Classic:
Depressing the Red lever allows the dispensing of boiling water.
Pulling forward the Red lever allows the tap to operate in a “no-touch” mode.
Water will flow from between 5 and 15 seconds (This is user adjustable).
To reset, return the handle to the “Off” position and repeat the step. The lever has to be manually returned to the “Off” position.
Elite Tap:
Touching the boiling button allows the dispensing of boiling water.
HydroTap Arc/Cube and Celsius AIO:
Gently tap the select button until the indicator light turns RED.
Rotating the control , when the indicator light is RED, allows the dispensing of boiling water.
Page 8 of 28 802254NZ - HT BC User Guide 10.18 v3.02
Tap lights
Red Boiling Water Light:
On all the time:
This indicates that the boiling water is ready.
Flashing slowly:
This indicates that the boiling water is below the desired temperature. Wait for the light to stop flashing before dispensing water. The flashing light will typically occur after switching on, or coming out of sleep mode.
(All)
Blue Chilled Water Light:
(Not available on Elite)
On all the time:
This indicates that the temperature of the chilled water is within the set temperature range.
Flashing slowly:
This indicates that the chilled water is not within the set temperature range. While flashing, water may be dispensed, but not at the set temperature. When the chilled water is at the set temperature, the light will stop flashing. This may take several minutes. During heavy usage, the temperature may rise out of the normal range.
Blue LightsRed Lights
Filter light
Classic Tap
Filter LightRed Light
Warning: (All)
Flashing warning light:
When the indicator light flashes fast and continuous, a system fault has occurred. Check for details on the command centre LCD screen. If unable to rectify, call a qualified service agent.
Elite Tap
802254NZ - HT BC User Guide 10.18 v3.02 Page 9 of 28
Loading...
+ 19 hidden pages