802254NZ - HT BC User Guide 10.18 v3.02 Page 1 of 28
** This user manual has been written according to firmware version B02.6.8
Please check the following website for the latest user manual:
zenithwater.co.nz
BC Residential
BC100/75
BC160/125
BC160/175
BC240/175
Page 2 of 28 802254NZ - HT BC User Guide 10.18 v3.02
Tap Safety Lock
The safety lock feature is provided to prevent boiling water flowing if the hot
lever is inadvertently operated.
This function can be activated and deactivated from either the Tap or from the
touch screen display (Located on the unit in the cupboard).
To set the tap safety setting: (Classic & Elite)
1. Press [MENU] button for main
menu.
2. Press [Setting] button.
3. Press [Safety] button.
4. Press button -YES / NO to
allow or disallow the safety
setting to be changed on the tap.
Note: The Factory setting is set at YES
A
HydroTap Classic
To activate the safety
for Classic & Elite taps
(From the tap):
After selecting to allow the safety setting
from the menu screen. Place a finger on
the safety lock, then depress the Classic
Blue/Chilled lever or touch the Elite Blue/
Chilled Button, while keeping both fingers
in position for a period of approximately
ten seconds.The Classic safety lock
indicator light will now be illuminated or
the Elite lights will flash, momentarily.
A
B
C
To deactivate the safety
(From the tap):
First place a finger on the safety lock,
then depress the Classic Blue/Chilled
lever or touch the Elite Blue/Chilled
Button, while keeping both fingers in
position for a period of approximately ten
seconds. The Classic safety lock indicator
light will now extinguish or the Elite lights
will flash, momentarily.
Safety Lock
For Hot Isolation:
Not for HydroTap Arc/Cube and Celsius
AIO (see page 20).
802254NZ - HT BC User Guide 10.18 v3.02 Page 3 of 28
Elite Tap
Tap functions
Classic Tap:
The Classic tap uses lever control
to dispense Boiling and Chilled
water.
The safety lock can be controlled
from either the tap or from the
touch screen display (see page 3).
Elite Tap:
The Elite tap uses touch sensitive
controls to dispense Boiling and
Chilled water.
When operating the tap, ensure
the touch surface is dry as moisture may interfere with the sensor
touch control.
The safety lock can be controlled
from either the tap or from the
touch screen display (see page 3)
Boiling ButtonChilled Button
Safety Lock
Boiling ButtonChilled Button
Safety Lock
Page 4 of 28 802254NZ - HT BC User Guide 10.18 v3.02
Tap functions
Celsius All-In-One Tap:
The Celsius AIO combines the
tap functions of the Arc/Cube tap
and the Classic Mixer tap. Please
see AIO tap and Arc/Cube tap
functions for the Celsius AIO.
Classic All-In-One Tap:
The top levers and safety lock
button of the Classic AIO tap are
operated in the same way as a
Classic HydroTap to dispense
Boiling and Chilled water.
The Mixer tap lever is operated as a
classic ‘Flick Mixer’. The hot side is
marked with a red mark and the cold
side with a blue mark, for dispensing
cold to warm water.
Lifting the handle up will decrease
the flow rate and lowering the
handle will increase the flow rate.
Lift the handle all the way up to turn
the tap off.
When the handle is moved towards
the blue mark, the temperature is decreased and when moved towards
the red mark, the temperature is increased. The final temperature will be
dependant on the temperature of the incoming cold water.
For convenience, the spout may be swivelled, left or right through 120°.
802254NZ - HT BC User Guide 10.18 v3.02 Page 5 of 28
Tap functions
HydroTap Arc/Cube and Celsius AIO:
Tapping the select button will
allow the choice of Boiling (RED)
with safety, Chilled (BLUE) or
Sparkling (WHITE) water mode.
The Arc/Cube control may be
rotated in a forward or reverse
direction to dispense Boiling or
Chilled water.
The rotary control is spring loaded in the anticlockwise direction
and when released, will return to
the OFF position. When rotated
clockwise the tap operates in a
“Pot fill” mode. Water will flow
from between 5 and 15 seconds
(this is user adjustable). To reset,
return the handle to the “Off”
position and repeat the step. The
lever has to be manually returned
to the “Off” position.
After activating the Boiling mode, all the lights will flash for 2 seconds, during
which time you may dispense water. When the rotary control is returned to the
Off position the light will continue to flash for an additional 3 seconds, allowing
you to dispense more water.
The control light will automatically default to the Chilled (BLUE) mode after 30
seconds of inactivity.
Rotary control
Select Button
Safety Lock
Mixer Tap:
Lifting the handle up will
decrease the flow rate and
lowering the handle will increase
the flow rate. Raise the handle
all the way up to turn the tap off.
When the handle is moved
towards the BLUE mark, the
temperature is decreased
and when moved towards the
RED mark, the temperature is
increased. The final temperature
will depend on the temperature
of the incoming cold water.
Page 6 of 28 802254NZ - HT BC User Guide 10.18 v3.02
Tap operation
To dispense Chilled water:
HydroTap Classic and
Classic All-In-One taps
Depress the “Blue” lever to dispense
Chilled water. Pulling forward the Blue
lever allows the tap to operate in a
“no-touch” mode. Water will flow from
between 5 and 15 seconds (this is
user adjustable). To reset, return the
handle to the “Off” position and repeat
the step. The lever has to be manually
returned to the “Off” position.
NOTE:
Chilled water will not be dispensed
if the safety button is accidentally
covered.
Elite Tap
Touch the Chilled button to dispense
Chilled water.
Press or pull lever
Classic Tap
Elite Tap
HydroTap Arc/Cube and
Celsius AIO
If not showing BLUE, gently tap the select
button until the indicator light turns BLUE.
Rotating the control, when the indicator
light is BLUE, allows the dispensing of
chilled water.
802254NZ - HT BC User Guide 10.18 v3.02 Page 7 of 28
Indicator
light
Select
button
Arc/Cube Tap
Tap operation
To dispense Boiling water: (WITH SAFETY ON)
HydroTap Classic:
Depress the Red lever, while simultaneously covering the safety lock button
with a second finger. These two actions need to occur simultaneously within
2 seconds for the successful dispensing of boiling water.
Elite Tap:
Place one finger on the safety lock, then touch the boiling button with a
second finger while keeping both fingers in position.
These two actions need to occur simultaneously within 2 seconds for the
successful dispensing of boiling water.
HydroTap Arc/Cube and Celsius AIO:
Gently tap the select button until the indicator light turns RED. Then tap the
safety button twice until the RED light flashes (This will flash for approx 2
seconds). Boiling water may be dispensed by rotating the control while the
RED light is flashing.
To dispense Boiling water: (WITH SAFETY OFF)
HydroTap Classic:
Depressing the Red lever allows the dispensing of boiling water.
Pulling forward the Red lever allows the tap to operate in a “no-touch” mode.
Water will flow from between 5 and 15 seconds (This is user adjustable).
To reset, return the handle to the “Off” position and repeat the step. The lever
has to be manually returned to the “Off” position.
Elite Tap:
Touching the boiling button allows the dispensing of boiling water.
HydroTap Arc/Cube and Celsius AIO:
Gently tap the select button until the indicator light turns RED.
Rotating the control , when the indicator light is RED, allows the dispensing of
boiling water.
Page 8 of 28 802254NZ - HT BC User Guide 10.18 v3.02
Tap lights
Red Boiling Water Light:
On all the time:
This indicates that the boiling water is ready.
Flashing slowly:
This indicates that the boiling water is below
the desired temperature.
Wait for the light to stop flashing before
dispensing water. The flashing light will typically
occur after switching on, or coming out of sleep
mode.
(All)
Blue Chilled Water Light:
(Not available on Elite)
On all the time:
This indicates that the temperature of the
chilled water is within the set temperature
range.
Flashing slowly:
This indicates that the chilled water is not within
the set temperature range. While flashing,
water may be dispensed, but not at the set
temperature. When the chilled water is at the
set temperature, the light will stop flashing. This
may take several minutes.
During heavy usage, the temperature may rise
out of the normal range.
Blue LightsRed Lights
Filter light
Classic Tap
Filter LightRed Light
Warning: (All)
Flashing warning light:
When the indicator light flashes fast and
continuous, a system fault has occurred.
Check for details on the command centre
LCD screen. If unable to rectify, call a
qualified service agent.
Elite Tap
802254NZ - HT BC User Guide 10.18 v3.02 Page 9 of 28
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.