Rack Chassis
Get Going Guide
This guide will take you through a typical
installation procedure, and will have you
broadcasting your own HDTV channel
in less than 10 minutes. For additional
assistance or more complex installations,
please refer to the ZeeVee Support page
at www.zeevee.com, where you will nd
answers to frequently asked questions,
and helpful tips from ZeeVee experts.
If you cannot nd the answers you
need, our technical support hot line
at 877-4ZEEVEE (877-493-3833) is
here to help.
Page 2 of 8 www.zeevee.com
HDbridge Rack Chassis Get Going Guide Page 3 of 8
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug.
A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade
or the third prong is provided for your safety. If the provided plug does not
t into your outlet, consult an electrician for replacement of the obsolete
outlet.
10. Protect the power cord from being walked on or pinched, particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
11. Unplug this apparatus during lightning storms or when unused for long
periods of time.
12. Only use attachments/ accessories specied by the manufacturer.
13. Refer all servicing to qualied service personnel. Servicing is required when
the apparatus has been damaged in any way, such as power-supply cord
or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
Rack Chassis – HDb-RK1
6RU TALL*
8 channels
QUALITY RF WIRING
Compression connectors
LAN WIRING
Customer supplied
DC POWER SYSTEM
Supplies up to 8 modules
AC POWER
Single connection
8 CHANNEL COMBINER
Pre-wired at factory
SINGLE RF CONNECTION
Carries all 8 channels
What’s in the Box
HDbridge Rack Chassis•
Get Going Guide•
34 dbmv launch power for
RF AMPLIFIER
all 8 channels
*with modules installed
Specications
RF Output Output Power +34dBmV typical
Power AC Input +120V, 1.6A
Physical Width 19 Inches
Height 7 Inches (empty)
10.49 Inches (with modules installed)
Depth 10.25 Inches
Weight 11.5 Lb. (empty)
30.5 Lb. (with 8 modules installed)
Temperature/Humidity Operating +32F to +104F (0C to +40C) /
20% to 80%, non-condensing