5. Place the short pole extension of the second display into
Second Display
Pole Extension
Existing Display
Pole Extension
Rotation
Limiting
Tab
the vacant slot in the rear housing of the existing display.
NOTE There is a rotation limiting tab on the bottom rib of
the pole extension. This needs to be fitted on one
side, or the other of the mating projection feature in
the rear housing. If not, it may be difficult to replace
the existing front housing.
Figure 5. Attaching Pole Extensions
6. Secure the pole grip in place using the two M3 x 12 self
tapping screws (supplied).
MP6000
SINGLE TO DOUBLE
SCALE DISPLAY
ASSEMBLY GUIDE
Figure 6. Securing in Place
7. Replace the back housing of the existing display. Install
the four M3 x 18 self tapping screws.
Zebra reserves the right to make c hanges to any product to improve reliability,
function, or design. Zebra does not assume any product liability arising out of, or
in connection with, the application or use of any product, circuit, or application
described herein. No license i s granted, either expressly or by implication,
estoppel, or otherwise under any patent right or patent, covering or relating to any
combination, system, apparatus, machine, material, method, or process in w hich
Zebra products might be used. An implied license exists only for equipment,
circuits, and subsystems contained in Zebra products.
Warranty
For the complete Zebra hardware product warranty statement, go to:
http://www.zebra.com/support
Refer to the MP6000 Integrator Guide for detailed product information. The latest
product documentation (Integrator Guide) is available at:
http://www.zebra.com/support
Zebra Technologies Corporation
Lincolnshire, IL U.S.A.
http://www.zebra.com
Zebra and the Zebra head graphic are registered trademarks of ZIH Corp.
The Symbol logo is a registered trademark of Symbol Technologies, Inc., a
Zebra Technologies company.
© 2015 Symbol Technologies, Inc.
MN000095A02 Revision A- February 2015

Assembling the Dual Head Scale Display
The single Scale Display for the MP6000 with scale can be
easily converted into a dual Scale Display. The steps that
follow include instructions to assemble the unit.
NOTE The assembly instructions that follow only apply
when adding a second display head to a single
display.
Required Tools
•
Sharp cutting instrument (e.g., scissors, craft knife,
etc.) to enable easy removal of the second display
from the packaging.
•
Phillips head screw driver.
In the Box
2. Remove the four securing screws from the rear of the
existing display. Remove the front housing assembly,
complete with LCD and PCB (see Figure 3).
The second Scale Display head ships complete with a
routed cable, pole grip, two M3 x 12 self tapping Phillips
screws, and a set of four display faceplate decals.
Figure 1. Second Scale Display
Follow these steps to convert a single display to a double
display:
1. Find the Scale Display faceplate decal with the identical
information that shows on the existing faceplate.
Remove the adhesive backing on the identical faceplate
decal, and carefully adhere it into place on the front face
of the second display.
Figure 2. Removing the Screws from the Existing Display
Figure 3. Removing the Front Housing Assembly
3. Remove the circular cap from the existing display and
either discard it, or keep is as a spare part.
NOTE The new faceplate must contain exactly the same
information as the one on the existing display.
Figure 4. Removing the Circular Cap
4. Connect the cable from the second display to the RJ11
connector on the PCB in the existing display. The words
To Slave appear on the PCB near the connector.