CLV1150E
Microwave Radios
CATV Modems
Satellite Communications
5
22
2±2
1100 1200
0.3-4.7
40
-111
-20
<1
<1
100
50
-40 to 85
-
Oscillation Frequency Range
Phase Noise @ 10 kHz offset (1 Hz BW, typ.)
Harmonic Suppression (2nd, typ.)
Tuning Voltage
Tuning Sensitivity (avg.)
Power Output
Load Impedance
Input Capacitance (max.)
Pushing
P ulling ( 14 dB R etur n Los s, Any Phas e)
Operating Temperature Range
Package Style
MINI -14S
MH z
dBc/H z
dBc
Vdc
MHz/V
dBm
pF
MHz/V
MH z
°C
Vdc
mA
Supply Voltage (Vcc, nom.)
Supply Current (Icc, typ.)
All specificati ons are t ypical unless otherwis e noted and subjec t to change wit hout notice.