End Product Labeling
This transmitter module is authorized only for use in device where the antenna may be installed such
that 20 cm may be maintained between the antenna and users. The final end product must be labeled in
a visible area with the following: “Contains TX FCC ID: M4Y-AG623C”.
RF Exposure Manual Information That Must be Included
The users manual for end users must include the following information in a prominent location
"IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, the antenna used
for this transmitter must be installed to provide a separation distance of at least 20 cm from all
persons and must not be co-located or operating in conjunction with any other antenna or
transmitter."
Additional Information That Must be Provided to OEM Integrators
The end user should NOT be provided any instructions on how to remove or install the device.
Service Center in U.S.A
Company Name : Zcomax.
Company Address:14545 Valley View Ave., Suite S Santa Fe Springs, CA 90670
Tel:562-926-4588
1. Introduction
54Mbps IEEE802.11a/b/g Wireless Network Mini PCI Adapter is the perfect solution for your wireless network
applications based on the IEEE 802.11a/b/g standard offering a data rate of 54Mbps in a wireless LAN
environment.
AG-623C
Internet Video Server gives you wireless access the web and network resource without the wire.
AG-623C
bit of WEP (Wired Equivalent Privacy) data encryption. With Direct Spread Spectrum Signaling
(DSSS) and Orthogonal Frequency Division Multiplexing (OFDM), domain access control, WEP
encryption and group security, the modules will safeguard all your wireless data transmissions from
your nosy neighbors.
AG-623C
information and online services anytime a nd anywhere.
is designed for Access Point, Router, ATUR, Printer Server series, IP Camera series and
provides high-speed access to network resources and has built-in 40/64-bit, 128 bit and 256
allows you to take full advantage of your devices mobility with access to real-time
2. Feature
Complies with IEEE 802.11a/b/g Standard for 2.4GHz Wireless LAN.
.
Works with All Existing Network Infrastructures.
.
Compatible with Wi-Fi Wireless Products and Services
.
. Capable of up to 256-Bit WEP Encryption.
. Freedom to Roam While staying Connected
. 54 Mbps High-Speed Transfer Rate
. Two UF-L Connectors for External Antenna
. Support Antenna diversity for Better Sensitivity
. Lower Power Consumption.
3.Specification
Product Description
IEEE 802.11a/g compliant 5 & 2.4 GHz WLAN miniPCI card with Super A & Super G
Host Interface
32-bit miniPCI,
Operating Voltage
DC3.3V ± 5%
Chipset
MAC / BB Processor Atheros AR5414 (Single chip)
PA Chip
Power Consumption
11a TX: ≦ 550 mA RX: ≦ 450 mA
11b TX: ≦ 550 mA RX: ≦ 450 mA
11g TX: ≦ 550 mA RX: ≦ 450 mA
Radio
RF5824 RFMD
Antenna
connector
Output Power
Sensitivity
Primary : one U.FL connector
Secondary :one U.FL connector
Temperature (Ambient) Humidity (non-condensing)
Operating -10 ~ 65 ℃
Storage -20 ~ 80 ℃ 5 ~ 90%
Warranty
12 months
4. Hardware Installation
The following sections in this chapter describe how to install AG-623CModule
4.1. Installation Overview
AG-623Cwireless module is design for Access Point, Router, ATU-R, Printer Server series, IP Camera
series and Internet Video Server only.
4.2. Safety Recommendations
The safety guidelines are as follows:
λ Keep the board area clear and dust-free before, during, and after installation.
λ Keep tools away from walk areas where you and others could fall over them.
λ Do not wear loose clothing or jewelry, such as earrings, bracelets, or chains, that could get
caught in the board.
Wear safety glasses if you are working under any conditions that might be hazardous to your
λ
eyes.
λ Do not perform any action that creates a potential hazard to people or makes
the equipment unsafe.
λ Never attempt to lift an object that is too heavy for one person to handle.
4.3. Maintaining Safety with Electricity
Warning: Before working on a board or working near power supplies, unplug the power cord on AC units;
on DC units, disconnect the power at the circuit breaker
Follow these guidelines when working on equipment powered by electricity:
λ Do not work alone if potentially hazardous conditions exist anywhere in your
work space.
λ Never assume that power is disconnected from a circuit; always check the
circuit.
extension cables, frayed power cords, and missing safety grounds.
λ If an electrical accident occurs, proceed as follows:
– Use caution; do not become a victim yourself.
Disconnect power from the system.
–
– If possible, send another person to get medical aid. Otherwise, assess the condition of the victim
and then call for help.
– Determine if the person needs rescue breathing or external cardiac compressions; then take
appropriate action.
- 7 -
4.4. Installing a AG-623C
λ
Remove the AG-623C module from its protective packaging.
λ
Avoiding Electrostatic Discharge
Before you install the AG-623Cmodule, ground yourself by touching a piece of metal
to avoid electrostatic discharge (ESD). You should also take the following
precautions to prevent damage to the AG-623C module:
λ Keep the AG-623Cmodule in its antistatic-shielded bag until
you are ready to install it.
λ Handle the AG-623C module by its edges.
λ Ensure the connector is connected to above Model’s board tightly.
.
Loading...