To enable you to use your appliance effectively and safely, please read this instruction book
carefully before using the appliance and retain for future reference. If you require guidance in
the use of the appliance or require further information on Zanussi Products, please contact
our Customer Care Department.
Customer Care Department
Zanussi
55 - 77 High Street
Slough
Berkshire
SL1 1DZTel: 08705 727 727
To register ownership, please ensure you complete and return the guarantee card supplied with the appliance.
For the User
Important Safety Information
Your Appliance
Operating Instructions
Cooker Hood Controls
To Operate
Recirculation
Extraction
Maintenance and Cleaning
External Cleaning
Metal Grease Filters
Charcoal Filters
To Remove/Replace the Charcoal Filters
Changing the Light Bulb
Something Not Working
Service and Spare Parts
Guarantee Conditions
For the Installer
Technical Information
Electrical Connection
Electrical Requirements
Electrical Connection
Installing the Cooker Hood
Installation Requirements
Unpacking
Clearance Heights
Fitting the Wall Brackets
Fitting the Canopy Hood
Venting
Recirculation
Fitting the Chimney Stack
Guide to use the instruction book
The following Symbols will be found in the text to guide you through the instruction book
Safety instructionsStep by step instructions
2
IMPORTANT SAFETY INFORMATION
These warnings are provided in the interests of safety. Ensure that you understand them all before installing or using this appliance. Your safety is of paramount importance. If you are unsure
about any of the meanings of these warnings contact the Customer Care Department.
•Installation
•Any installation work must be undertaken
by a qualified electrician or a competent
person.
•This hood must be installed in accordance
with the installation instructions and all
measurements must be adhered to.
•If the cooker hood is installed for use above
a gas appliance then the provision for
ventilation must be in accordance with the
Gas Safety Codes of Practice BS.6172,
BS.5440 and BS.6891 (Natural Gas) and
BS.5482 (LP Gas) 1994, the Gas Safety
(Installation & Use) Regulations, the
Building Regulations issued by the
Department of the Environment, the Building
Standards (Scotland) (Consolidated)
Regulations issued by the Scottish
Development Department.
•The fan motor of this cooker hood
incorporates a cut-out device which will
operate if the cooker hood is installed below
the height recommended under the section
‘Clearance Height’, or if the motor becomes
overheated. If the cut-out device is activated,
switch off the fan motor and allow the cooker
hood to cool. The cut-out device will reset
itself when the fan motor has cooled
significantly.
•It is dangerous to alter the specifications or
modify this product in any way.
•When installed between adjoining wall
cabinets the wall cabinets must not overhang
the hob.
•If the room where the cooker hood is to be
used contains a fuel burning appliance such
as a central heating boiler then its flue must
be of the room sealed or balanced flue type.
•If other types of flue or appliances are fitted
ensure that there is an adequate supply of air
to the room.
•The ducting system for this appliance must
not be connected to any existing ventilation
system which is being used for any other
purpose.
•Do not install above a cooker with a highlevel grill.
•Child Safety
•This appliance is designed to be operated by
adults. Children should not be allowed to
tamper with the appliance.
•During Use
•This product is for domestic use only.
•Never leave frying pans unattended during
use as overheated fats and oils might catch
fire.
•Never do flambé cooking under this cooker
hood.
•Do not leave naked flames under the cooker
hood.
•Maintenance and Service
•This appliance can be a hazard if the grease
filters and charcoal filters are not cleaned
and replaced as recommended.
•Under no circumstances should you attempt
to repair the appliance yourself. Repairs
carried out by inexperienced persons may
cause injury or more serious malfunction.
Refer to your local Zanussi Service Force
Centre. Always insist on genuine spare parts.
3
YOUR APPLIANCE
L
V1V2V3
S
0
-
1M
ID
M
A
X
0
-
1
265
300
500
898
OPERATING INSTRUCTIONS
73
433
740 min
740
950 max
This cooker hood is designed to extract
unpleasant odours from the kitchen, it will not
extract steam.
Cooker Hood Controls
The cooker hood functions are controlled by five
push button switches located centrally in the
control fascia.
LPush to switch ON the worktop lighting.
SRed neon indicates the fan motor is
switched ON.
V1Push to switch ON the motor at the low
speed, for use with one burner or
when simmering.
V2Push to engage the medium speed, for
normal cooking up to four pans.
V3Push to engage the high speed, for use
when frying or cooking foods with
strong odours.
4
To Operate
Select the required fan speed and light if required.
The appliance can be installed to recirculate or
extract contaminated air. The cooker hood is more
effective when used in the extraction mode.
Recirculation
The cooker hood is supplied specified for use in the
recirculation mode with the charcoal filter fitted.
The contaminated air is cleaned by passing through
the filters and then back into the kitchen.
The activated charcoal filter absorbs odours arising
from cooking. In use it will slowly become saturated
in grease and less effective. The filter normally
requires changing at least every three months or
more frequently if the hood is used for more than
three hours per day.
Extraction
The contaminated air enters the cooker hood
passing through the grease filters and out through
the ducting into the atmosphere.
When used in the extract mode the charcoal filter is
not required and must be removed.
Never do flambé cooking under this cooker
hood.
Take extra care when frying and never leave
frying pans unattended during use, as overheated fats and oils can catch fire.
Do not leave naked flames under the cooker
hood.
Ensure the hood is switched ON before
using the hob.
Ensure heating areas on your hob are
covered with pots and pans when using the
hob and cooker hood simultaneously.
Ensure not to damage the charcoal filter
when cleaning or replacing as the activated
charcoal inside is saturated with grease,
which will stain if it comes into contact with
clothing or furnishings.
5
MAINTENANCE AND CLEANING
Before carrying out any maintenance or
cleaning isolate the cooker hood from the
mains supply.
The cooker hood must be kept clean, as a
build up of grease or fat can be a fire
hazard.
External Cleaning
The metal casing, visor and chimney should be
cleaned at least once a month to keep the hood
looking like new. Wipe over the hood with a soft
cloth wrung out in mild soapy water and then dry
thoroughly.
Always wear protective gloves when
cleaning the hood.
Never use scouring pads or abrasive
cleaners as they may scratch of damage
the surfaces.
Never use excessive amounts of water
when cleaning particularly around the
control panel.
Metal Grease Filter
The metal grease filter should be cleaned at least
every month. The filter may be washed by hand
using mild soapy water, or can be machine washed
in a dishwasher. Allow to dry completely before
replacing.
To Remove the Grease Filter
Remove the metal grease filter by pushing
inwardly on the two steel handles; replace,
making sure the handles have sprung back
into position and are completely visible.
6
Loading...
+ 13 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.