RANGE
COMPOSITION
Chilling means bringing the temperature of
cooked food from +90ºC to +3°C in a short
time lap to minimize bacteria proliferation and
avoid loss of food consistency and texture.
The ZANUSSI easyChill Blast
Chillers/Freezers reduce temperature to
+3°C at food core in less than 90 minutes
and down to -18°C in less than four hours.
After the Blast Chilling a holding cycle starts
automatically to respectively maintain food at
+3°C and -18°C. Blast freezed food has a
solid 6 months/1 year shelf life without loss of
flavour, nutritional values and weight. The
opportunity to prepare in a single shot the
food to be used in different times during the
week enables a better work scheduling and
therefore a sensible reduction in labour costs.
110723
ACTIVE BLAST CHILLER / FREEZERS
FUNCTIONAL AND
CONSTRUCTION
FEATURES
� Soft Chilling (Air temperature
–2°C).
� Hard Chilling (Air temperature
–20°C).
� All the probe-driven cycles feature
ARTE (Algorithm for Remaining
Time Estimation): the machine
displays the actual time needed to
end the cycle and to make planning
the activities easier.
� Holding at +3°C (automatically
activated at the end of each cycle).
� Turbo cooling: the chiller works
continuously at the desired
temperature. Ideal for continuous
production and for pastry application.
� Automatic recognition of the
insertion of the food probe (cycles
piloted either by food probe
temperature or by time)
� Single sensor core probe as
standard.
56 KG - 20 GN 1/1
ZANUSSI
P R O F E S S I O N A L
TECHNICAL DATA
CHARACTERISTICS MODELS
BCF64A
110723
Power supply Electric
Productivity per cycle - kg.
NF Regulations - chilling / freezing 43.2
UK Guide lines - chilling / freezing 64, 56
Gross capacity (D.I.N. 8952) - l. 560
Cooling unit Built-In
External dimensions - mm
width 800
depth/with open doors 835, 1570
height 2230
Internal dimensions - mm
width 680
depth 450
height 1500
N° and type of door 1
Door hinges Right Side
Trays type GN 1/1; 600x400
Max load capacity - trays h 65 mm - n° 12
Compressor power - HP 3
N° defrost in 24 hrs. 3
Refrigerant type R404a
Refrigerant quantity - g. 3600
Refrigeration power - W 2810
Refrigerant power
at evaporation temperature - °C -30
Power - kW
installed-electric 3.933
Noise level - dBA 71.5
Net weight - kg. 235
Power supply - V, phases, Hz 400 V, 3N, 50
INCLUDED ACCESSORIES
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER 1
REMOVABLE TRAY SUPPORT RACK FOR 20 GN1/1 4
ACTIVE BLAST CHILLER / FREEZERS
56 KG - 20 GN 1/1
� The control unit provides several
operating settings: time/core
temperature according to NF and UK
regulations, time/air
temperature/probe personalised
according to national regulations,
sterilizing cycle: UV lamps built-in
(on request), 3 single sensor or
3-sensor temperature probes (as
accessory), ideal for meats,
automatic defrosting and manual
defrosting. All parameters are
programmable.
� The control unit provides two large
displays to read out: time, core
temperature, residual time, alarms,
service information.
� Two customizable cycles for each
operating modes, allowing setting
time and air temperature. These two
programs (P1-P2) can be converted
into ice-cream specialist cycles
(shape maintenance and holding).
� All information related to the
different operating models are
recorded: date, time, cycle, core
temperature, holding temperature,
HACCP accordance.
� An audible alarm starts when the
cycle ends or terminates abnormally.
� Chilling times can vary according
to food quantity, density, moisture
contents and type of containers.
� Internal and external finishing in
304 AISI stainless steel and
backpanel in galvanized steel.
� HCFC, CFC and HFC free
insulation (Cyclopentane), HCFC
and CFC free refrigerant gas
(R404a).
� Developed and produced in ISO
9001 and ISO 14001 certified
factory.
� Inner cell with rounded corners.
� Door equipped with removable
magnetic gasket with hygienic
design.
� Evaporator with antirust
protection.
� Ventilator swinging panel foreasy
access to the evaporator.
� Automatic heated door frame.
� Hot gas defrosting system.
� Thermostatic expansion valve to
optimize the cooling unit efficiency.
� Adjustable feet 150 mm high.
� Stand alone printer as accessory.
� PC connection as accessory, gate
RS 485. No water connections
required: Waste water can be
plumbed into drain, but can also be
collected in an optional waste
container.
OPTIONAL ACCESSORIES
ACCESSORIES MODELS
3-SENSOR PROBE FOR CHILLER+C/FREEZER 880088
60-MM PITCH ROLL-IN RACK FOR 20X1/1 922203
80MM PITCH ROLL-IN RACK 14X1/1GN 922205
KIT 3 SINGLE SENSOR PROBES FOR BC/BCF 880269
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW 880183
KIT HACCP EKIS 922166
PAIR OF 1/1 GN AISI 304 S/S GRIDS 921101
PLASTIC COATED GRID-600X400 MM 880864
PRINTER FOR HACCP BASIC VERSION 881532
RACK RAILS FOR VERTICAL BLAST CHILLER 881182
REMOVABLE TRAY SUPPORT RACK FOR 20 GN1/1 881010
RILSAN COATED GRID 881061
TROLLEY FOR 20X1/1 ROLL-IN RACK 922132
DCB03 2009-09-23 The Company reserves the right to alter technical specifications without prior notice.
BCF64A
110723
ZANUSSI
P R O F E S S I O N A L
www.zanussiprofessional.com