ENS20 is a compact, in all usual functions and time ranges simply
programmable digital timer/counter. By use of a tight-fitting
keyboard the front of the equipment is protected against splashwater completely. Therefore ENS20 is suitable ideally for the
employment at bakery machines, machine tools, manufacturing
automats etc..
Front protection IP65
Simple programming by integrated keyboard
7 programmable time ranges 0.01 s - 999 h
All usual functions programmable
Only 48 x 48 mm front size
Timing begins either with the programmed time value
(preselection) and ends at zero or it begins with zero and
ends at the preselected value. Stop, resetting as well as
adjusting new parameters during the timing operation are
possible.
Keyboard function during timing/counting
The keyboard disabling (LOCK) is activated, if the keys "<"
and "R" are pressed while connecting the supply voltage.
By this the keyboard can be blocked against inadvertent
adjusting in critical applications. Deactivating is effected by
renewed actuation "<" and "R" while switching on the supp-
ly voltage.
Reset functions
By operation of the backspace key "R" or the RESET-input
(1-2) the ENS20 is set to the programmed preselected
value in each operating condition. The RESET signal (1-2)
and "R" - key have priority in relation to the START signal.
ENS20 can be used in numerous modes of operation as
timer or as counter. The different functions are now described in detail.
Reset on zero or to the preselected
value
Announcement of the preselected
value; timing continues in the background with all switching functions
Programming mode; depending on
function attitudes only possible if no
+
starting signal is acticvated
With power on activate the simultan-
+
eous pressing of these keys the
LOCK function (keyboard disabling)
Errors and technical changes reserved
English translation
Safety
Precautions
The installation and operation must be carried out by
qualified personnel only,
who is familiar with the professional handling of machine
equipment,
who is familiar with the valid rules of industrial safety
and accident prevention,
who read and understood the operating instructions.
The safe function of the device during machine operation
cannot be guaranteed in case of wrong connection or
improper operation. This may lead to fatal injuries.
Pay attention to country specific regulations.
The electrical installation must be performed after dis-
connecting the device and the machine from the mains
supply.
The wiring must be carried out according to the instruc-
Non-observance of the instructions above will cause the
loss of warranty.
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany
2
Digital Timer/Counter ENS20
Operating Instructions
Programming
ENS20 as timer (2-0 to 2-6, see function 2)
Timing begins with turning on the starting signal (1-3) and
can be interrupted by this input as desired. The START
input 1-3 can be closed by a cable link. In this case timing
begins directly with switching on the mains voltage. RESET
and START input have an internal noise pulse suppression.
They may be activated by contacts or electronic initiators.
ENS20 as counter (2-7, see function 2)
All functions 3 to 8 also apply to the counter mode. The
clock input is provided at the terminals 3 (+12..24 V) and 1
(0 V). Counting is done by closing an external counting
contact. Also 2- or 3-wire semiconductor outputs of initiators can be used. The falling edge is counted.
The following function settings are valid depending on the
value of the function 2 for timer mode (2-0 to 2-6) or
counter mode (2-7).
Display
Function 3:
Timing functions
3– 0 On-delay. Timing begins with applying of
the mains voltage and closing of the
START-contact. After timing the contacts
switch from 15-16 to 15-18 until the arrival
of a resetting signal, at least however for
100 ms.
3 – 1 Impulse-limiting. As On-delay, however
the contacts are switched on with application of the mains voltage immediately (15-
18) and back to 15-16 after timing.
Errors and technical changes reserved
Display
2 – 0 0.01 - 9.99 s
2 – 1 0.1 - 99.9 s
2 – 2 1 - 999 s
2 – 3 0.1 - 99.9 min
2 – 4 1 - 999 min
2 – 5 0.1 - 99.9 h
2 – 6 1 - 999 h
2—7 Counter mode
Display
Function 5:
Function 2
Timing ranges
Power failure function
5 – 0Continuation. Timing is continued after
power failure with the value reached last.
5 – 1Restart. Timing begins after power failure
with zero or with the preselected value
(RESET after power failure).
Display
Function 6:
Enable/disable programming
6 – 0 Programming enabled during timing.
Programming during timing (i.e. the START
signal is turned on) is enabled. Timing is
stopped and continued after the recent
time preselection with the new values.
English translation
3 – 2Flashing (T1=T2). The ENS20 works after
applying of the mains voltage and closing
of the START contact as symmetrical cycling timer. The cycle starts with output off
(relay switched off). On and off time are
equal.
3 – 3Flashing (T2=100ms). In this operating
condition the output relay switches periodically for 100ms. The total cycle time is determined by the preselected current value.
3 – 4 Signal off-delay. The control is made by
the START contact. The contacts switch on
immediately and after opening the starting
contact timing begins. After timing the
contacts switch back to 15-16. A stop is not
possible here.
3 – 5... Free for customized special functions
Dispaly
Function 4:
Counting direction
4 – 0upward. Timing/counting begins with zero
and ends with the preselected value. A
RESET signal sets back to zero.
4 – 1downward. Timing begins with the presel-
ected value and ends with zero. A RESET
signal sets back to the preselected value.
6 – 1 Programming disabled during timing.
The programming mode by "<" and ">" -
keys is not possible during timing (i.e. the
START signal is turned on). Programming
only, if the START input is turned off.
Display
Function 7:
Aux. contact, only version 52311x
7 – 0 Auxiliary contact is immediate contact.
Timer mode: The 2nd contact switches
with applying the START signal .
Counter mode: The 2nd contact switches
on with the first counting pulse.
7 – 1 Auxiliary contact is progammable pre-
contact
The display shows next "Pxx ".
xx is the timer/counter value of the 2nd
contact. Set the value with <, > e.g."P52".
Through this the 2nd contact switches on
52 clocks before reaching the timer/counter
preselection (1st contact). With the value
"P00 " the 2nd contact switches at the
same time as the 1st contact with reaching
the preselection value.
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany
L05
E61-282-00
3
8
100
45
48
55
R
PR
LOCK
Digital Timer/Counter ENS20
Operating Instructions
Maintenance
Techn. Data
The device must be checked once per month for proper
function and for signs of tampering.
Operating voltage DC 24 V, AC 230V / AC 115 V, 50-60 Hz
Residual ripple + / - 10%
Power consumption < 2 VA
LED´s 3 digits, 7 mm red, time up indication
Protection IP65 front
Internal data storage time 10 years
Contacts 2 changeover contacts
Switching capacity AC 250 V, 8 A; DC 24 V, 3 A
Contact life mechanical 2x107 operations
electrical 105 operations
Inputs 2, 3 DC10..30 V or external contact
Time base quartz-stabilized, time tolerance: < 0.1%
Min. power-off time function 5-1:100 ms, function 5-0: 200 ms
Input frequency / counter 50 / 500 Hz programmable
Trigger closing of the contact / falling edge
Time ranges 7 between 0.01 s and 999 h
Temperature range 0°C - +500C
Dielectric strength 4 kV DIN VDE 0110-1:1997-04
Weight approx. 200 g
The device is otherwise maintenance free, provided that it
was installed properly.