ZANDER RELE DNV certifikat

Digitally Signed By: Schaarmann, Arne
Signing Date: 2019-06-12
Location: DNV GL SE Hamburg, Germany
Certificate No: TAE00003JF
TYPE APPROVAL CERTIFICATE
This is to certify:
That the Safety Relays
with type designation(s)
SR3C..., SR3D...., SK3D...
Issued to
H. Zander GmbH & Co. KG
Aachen, Nordrhein-Westfalen, Germany
is found to comply with
DNV GL rules for classification – Ships, offshore units, and high speed and light craft
Application :
Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL.

Issued at Hamburg on 2019-06-11
This Certificate is valid until 2024-06-10. DNV GL local station: Essen
Approval Engineer: Harald Amberger
for DNV GL
Arne Schaarmann
Head of Section
This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed.
Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 1 of 3 © DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.
Job Id: 262.1-031008-1
Certificate No: TAE00003JF
Product description
SR3C…, SR3D… Emergency Stop Safety Relays SK3D… Safety Coupling Relays
Type: SR3C…, SR3D… Ratings: Operating voltage AC 230 V, AC 115 V, AC/DC 24 V*, AC: 50-60 Hz Safety contacts 3 NO AC: 250 V, 2000 VA, 8 A for AC-12 250 V, 3 A for AC-15 DC: SR3C: 40 V, 320 W, 8 A for DC-12
SR3D: 30 V, 240 W, 8 A for DC-12 24 V, 3 A for DC-13 Auxilliary contacts 1 NC AC: 250 V, 500 VA, 2 A for AC-12 250 V, 3 A for AC-15 DC: SR3C: 40 V, 80 W, 2 A for DC-12
SR3D: 30 V, 60 W, 2 A for DC-12
Type: SK3D… Ratings: Operating voltage AC 230 V, AC 115 V, DC 24 V, AC: 50-60 Hz Safety contacts 3 NO AC: 250 V, 2000 VA, 8 A for AC-12 250 V, 5 A for AC-15 DC: 30 V, 240 W, 8 A for DC-12 24 V, 4 A for DC-13 Auxilliary contacts 1 NC AC: 250 V, 500 VA, 2 A for AC-12 DC: 30 V, 60 W, 2 A for DC-12
Safety category 4, PL e acc. to EN ISO 13849-1 and SILCL 3 according IEC 62061 / IEC 61508 Further ratings acc. manufacturer documentation.
Application/Limitation
Location Classes: Temperature: B, Humidity: B, Vibration: A
* Insulating transformer acc. to EN60742 must be used. Operating instruction of the manufacturer to be observed
Type Approval documentation
As per tech.-docs. in NPS 262.1-031008-1
Tests carried out
IEC60204-1:2016, Cold, dry heat, damp heat, vibration.
Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 2 of 3
Loading...