DMC01, PMC01
Supply Specifications
General Specifications
Power supply Overvoltage cat. III
Rated operational voltage (IEC 60664, IEC 60038)
through terminals:
A1, A2 or A1, A3 (DMC01)
B48 24 or 48 VAC ± 15%
45 to 65 Hz
B23 115 or 230 VAC ± 15%
45 to 65 Hz
724 24 VDC ± 20%
2, 10 (PMC01)
024 24 VAC ± 15%,45 to 65 Hz
115 115 VAC ± 15%,45 to 65 Hz
230 230 VAC ± 15%,45 to 65 Hz
724 24 VDC ± 20%
Voltage interruption ≤ 10 ms
Rated operational power
AC supply: 5 VA
DC supply: 2 W
Power ON delay ≤ 100 ms
Reaction time from trigger
Delayed contact(s) < 10 ms
Instantaneous contcat < 20 ms
Indication for
Power supply ON LED, green
Output relays ON LED, yellow (flashing when
timing)
Environment (EN 60529)
Degree of protection IP 20
Pollution degree 3 (DMC01), 2 (PMC01)
(IEC 60664)
Operating temperature -20 to 60 °C, R.H. < 95%
Storage temperature -30 to 80 °C, R.H. < 95%
Housing dimensions
DMC01C 22.5 x 80 x 99.5 mm
DMC01D 45 x 80 x 99.5 mm
PMC01 36 x 80 x 94 mm
Weight 120 to 260g depending on
model
Screw terminals (DMC01)
Tightening torque Max 0.5 Nm according to
IEC EN 60947
Approval UL, CSA
CE Marking Ye s
EMC Electromagnetic Compatibility
Immunity According to EN 61000-6-2
Emission According to EN 61000-6-3
Timer Specifications According to EN 61812-1
Function/Range/Time Setting
Adjust the function setting
the DIP switches 1 to 6 as
shown below (1 to 4 for
DMC01Cxxx).
Note 1: DIP switch 5 must
be kept ON when using
PMC01Dxxx.
Note 2: DIP switch 6 does
not have any effect on the
PMC01Cxxx working mode.
To access the DIP switches
open the grey plastic cover
using a screwdriver as
shown below.
Upper knob:
Selection of function:
Op - Delay on operate,
manual start
Oa - Delay on operate,
automatic and manual
start
In - Interval, manual start
Ia - Interval, automatic
and manual start
Nr - Interval with no time
reset, manual start
Na - Interval with no time
reset, automatic and
manual start
Dr - Delay on release
Centre knob:
Time setting on relative
scale: 1 to 10 with respect
to the chosen range.
Lower knob:
Setting of time range
External potentiometer
(DMC01D, PMC01C):
Time setting on relative
scale: 1 to 10 with respect
to the chosen range.
Output Specifications
Output 1 or 2 x SPDT relay
Rated insulation voltage 250 VAC (RMS)
Contact Ratings (AgSnO
2
)µ
Resistive loads AC 1 8 A @ 250 VAC
DC 12 5 A @ 24 VDC
Small inductive loads AC 15 2.5 A @ 250 VAC
DC 13 2.5 A @ 24 VDC
Mechanical life ≥ 30 x 106operations
Electrical life ≥ 10
5
operations
(at 8 A, 250 V, cos ϕ = 1)
Operating frequency < 7200 operations / h
Dielectric strength
Dielectric voltage 2 kVAC (RMS)
Rated impulse withstand volt. 4 kV (1.2/50 µs)
Sensor type selection
ON ON OFF OFF: PNP/NPN sensor,
Open collector
or contact
OFF OFF ON ON: Namur sensor
Time setting (DMC01D and PMC01C)
ON: Centre knob on front
OFF: External trimmer
Second relay
ON: Instantaneous
OFF: DPDT
DMC01D,
PMC01C,
PMC01D
DMC01C