This is a three-time controller into the evening (evening) working time, an interval of rest or
pause time, Dawn working time (morning light function), the user can according to their
needs, set a different time.
This is a compatible MPPT charge controller PWM intelligent / efficient / energy saving, he
not only has efficient MPPT controller charging function to automatically track the
maximum power point, 10% -30% higher than the ordinary controller charging efficiency,
also has standby energy saving, more than 30% energy than ordinary controller, the
standby power consumption of only 10mA-15mA.
1:Product introduction
"T" series of an intelligent, multi purpose solar charge controller
LCD screen display Battery reverse discharge protection
Simple (and more time control) operation Battery reverse polarity protection
MPPT+ PWM charging mode Battery under voltage protection
Parameter user can reset Overload, short-circuit protection
A key to open and close the load
Automatic temperature compensation
function
Installation(Installing wires, first loosen the screw counterclockwise)
1 Ready installation tools and materials, and cable. Please
2 ensure that the current density <4A/mm2 This will help reduce the
3 Install the controller fixed to the vertical plane, see Section V mounting aperture and
4 As shown on the right wiring sequence: load, battery, solar
A key to restore the factory settings USB5V charge (current 500mA) Optional
2: Installation Instructions
Check the installation site meets the relevant safety requirements, avoid damp,
dusty, flammable, explosive and corrosive gases
hole spacing. In order to ensure a good controller cooling conditions, the controller
on the bottom of each reserved 10cm space
Battery plate is connected to the controller to be taken to ensure that the load,
battery,
The polarity of the solar cell panel and controller
YSmart Technology Co.,Ltd www.ysmart-tech.com www.chinasolarregulator.com 86-755-85232255
5 Before use: external temperature sensor probe into the left of the controller
6 Warning: In order to prevent accidents from occurring, install: non-professionals can
Stop battery is fully charged
voltage (can be set)
Under voltage battery
Load voltage is switched
on again
Load output state is set:
Set to 00H, said that under the light control mode, after dark (dusk)
open load; after dawn (Dawn) load to stop working.
Set to: 24H represents the load has been open until the battery voltage
protection automatically disconnects the load;
Set time: 01H to 23H, said under the next delay lighting control mode,
the load is loaded loaded loaded automatically after a delay before
disconnecting a few hours in the evening and applications. (Expressed
as the number of time delay)
Load output state is set: the length of the second opening hours or workload;
Set to: 00H means no load open or the length of time the load power 0H;
Set: 01H24H said opening a load length of time; (numbers indicate the
length of time corresponding to the open load).
temperature probe interface probe placed in similar battery temperature. (Line
extension must be built-in devices of the external temperature probe coextensive
Otherwise, the controller will control parameters of the temperature compensation of
the error
not be engaged in loading and unloading operations
3:LCD operating interface description
Charging Charging Fault Is discharging Discharge failure
A
Solar charging
current
PV OFF
V
℃
temperature
Ambient
Load OFF
Load current Battery capacity
V
A %
Load ON
V
Battery under voltage stop
the supply voltage (can be
set)
Evening
H
An interval of time setting (set this time, Dawn to Evening; to stop working
Interval
H
load time)
Set to: 00H indicates Evening to Dawn without the interval or intervals of 0H
Set to: 01H to 24H represents Evening to Dawn stopping power load time
(corresponding to the numbers indicate the length of time delay).
Dawn
H