YPZ
7000 BTU Portable A/C
Owners Manual
Thank you for selecting our high-quality mobile air conditioner from Yoau. Before
use, please read this entire manual carefully for information regarding setting up your
portable A/C, operating it, and tips on regular maintenance. For any problems, please
contact (GCR Warranty Information).
Table of Contents
Table of Contents-----------------------------------------------------1
Important Safety Precautions--------------------------------------2
Key Features-----------------------------------------------------------3
Parts & Accessories------------------------------------------------4-5
Control Panel----------------------------------------------------------6
Remote Control--------------------------------------------------------7
Installation-------------------------------------------------------------8
Operating Methods---------------------------------------------------9
Drainage Operation-------------------------------------------------10
Maintenance----------------------------------------------------------11
Troubleshooting------------------------------------------------------12
Limited Warranty Information-----------------------------------13
-
- 1 -
-
Important Safety Precautions
* Please put the air conditioner in flat and dry places. Keep the air conditioner 50cm
away from the surrounding objects.
* Power supply of the air conditioner shall comply with the safety regulations where it
is used and ensure reliable grounding.
* After installation of the air conditioner, ensure the plug is perfect and can be inserted
into the socket securely.
* Keep air inlet and outlet unimpeded.
* The air conditioner shall be far away from gasoline, cooking stoves or other
combustibles and heat sources.
* Always keep regular and orderly placement of wires to avoid stumbling people or
* The air conditioner is only used for households other than other places.
* Please do not install the air conditioner in washhouses or other places with water and
* Please do not turn on or off the air conditioner by inserting or pulling out the plug.
* Do not place things on the air conditioner.
* Do not put anything into air inlet and outlet.
* Do not use insecticide spray or other flammable matters in the vicinity of the air
* Do not splash oil or water into the air conditioner.
* Do not clean the air conditioner with water, but wipe with semi-wet soft cloth.
* Do not wipe the air conditioner with chemical solvents such as benzene, gasoline
and alcohol, etc. If the air conditioner is dirty indeed, please scrub with neutral
For your and your families’ health, please read the following safety precautions
carefully before use of this air conditioner:
Requirements
*The appliance shall be installed in accordance with national wiring regulations.
* If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
* This appliance can be used by children aged from 8 years and above and persons
with reduced physical ,sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not
play with the appliance.Cleaning and user maintenance shall not be made by
children without supervision
Recommended operation environment: temperature: 17℃-35℃, relative humidity:
20-85%RH
- 2 -
-
-
Key Features
* Brand new generation condensate self-evaporation design, environment friendly
*L type evaporator design, enabling more compact and efficient body.
*Ultrahigh loading quantity, greatly saving logistics cost.
*Downsizing and compact design of the whole air conditioner.
*Simple and convenient installation of accessories such as exhaust pipe, etc.
*Self-diagnosis function and 24h on/off timer function.
*Design of universal wheel with convenience for movement.
*Quiet design, applicable to use during sleep.
*Low noise and powerful air supply.
*Protective function of automatic restart of compressor after 3min time delay.
and Parts
- 3 -
-
-
-
Attention: if the air conditioner is restarted immediately after shutdown in COOL or
HEAT mode, 3min protection time is necessary before automatic start.
POWER: press this button to turn on or off the air conditioner.
MODE:During on or timer on pressing this button can select COOL, DEHUMIDIFY,
FAN and HEAT modes, etc. (the HEAT mode only exists in COOL/HEAT YPZ-H
The corresponding indicator lamp to the selected mode is on.
UP and DOWN:If the timer on or timer off is set, pressing UP or DOWN can adjust
on/off time; in running state of COOL or HEAT mode or timer state, pressing UP or
DOWN can adjust the set temperature; and pressing UP and DOWN simultaneously
can realize conversion between ℃ and ℉.
SPEED:Pressing this button can select different speeds in cycle of LOW and HIGH;
the corresponding indicator lamp to the selected speed is on.
TIMER:Press this button to enter timer setting state, and the indicator lamp is on.
DUAL 88:This pattern displays the set temperature in COOL and HEAT modes, and
displays room temperature in FAN and DEHUMIDIFIES modes; display of℃shows
current centigrade temperature, and display of ℉ shows current Fahrenheit
temperature. 88 when displayed as E2 means abnormal sense of room temperature
sensor; 88 when displayed as E3 means abnormal sense of evaporator temperature
sensor; 88 when displayed as df means the cooling system is in anti-freezing state or
defrosting state; and 88 when displayed as FL means the air conditioner is in water
full alarm state currently.
SLEEP: This indicator lamp is normally on when SLEEP state is started.
WATER FULL: In water full state this indicator lamp flickers with buzzer to prompt
- 4 -
-