Yoshimasa YMAC36, YMAC48, YMAC60 User Manual

USER’S MANUAL
www.YOSHIMASAUSA.com
Instruction Manual
READ AND SAVE THESE INSTRUCTIONS
Read and follow all instructions before Operating Fan. Do not use fan if any part is damaged or missing.
WARNING:
z To Reduce the Risk of Fire or Electrical shock, Do Not Expose to Water or Rain. z To Reduce the Risk of Fire or Electrical shock, Do Not Use This Fan with Any Solid State
Speed Control Device.
z DO NOT use fan in windows. Rain and moisture may create electrical hazard. z Unplug fan from outlet when not in use, when moving fan from one location to another or
before cleaning.
1: WIRING DIAGRAM
2: SPECIFICATION (110-127V-60Hz)
3: INSTALLATION DIMENSIONS
[Inch]
4: INSTALLATION METHOD WARNING: INSTALLATION & ELECTRICAL CONNECTION MUSTBE PERFORMED
BY QUALIFIED TECHNICIAN
1) Accessories: 6sets of (M60L) Fastening bolt, Washer, Spring washer, and (M8) Nut
2) Check to ensure the voltage /frequency on rating label is complied with the local power source before use.
3) Follow the right diagram for installation position.
4) Coverage height: 99 Inches (for horizontal air curtain installation).
Installation on concrete wall:
a. Take down INSTALLATION PLATE (Unscrew the fixing screws down the REAR and take down INSTALLATION PLATE). See Following diagram:
b. Install INSTALLATION PLATE on the wall:
- To fix position of installation.
- Insert bolts and fill with cement for consolidation.
- After cement solidifies, Install INETALLATION PLATE on bolts and fasten it with washers, spring washers and nuts. (See diagram on the right)
- To ensure INSTALLATION PLATE is fixed securely.
c. Install BODY (Hang up BODY onto the INSTALLATION PLATE,
check to ensure it is proper and secure, and then tighten the fixing screws). (See following diagram)
6) Other installation methods.(See following diagram)
7) Use more than one piece of air curtain with appropriate length to fill up the width of the doorway.
8) The recommended distance between 2 adjacent sets of air curtain is to be 1-2 inch.
5. OPERAT ION INSTRUCTIONS
1) Switch on the power.
2) Press the key stoke of OFF, LO, HI on the switch to set speed at OFF, LOW and HIGH. Press relevant function key stoke for remote Controlling unit.
3) Adjust AIR DEFLECTOR to preferred positions. (See following diagram)
6. CAUTIONS AND MAINTENANCE
1) Install at location firm enough for safety, check installation quality periodically.
2) Do Not install air curtain at location with water-splash, or with permanent exposure to high temperature and places close to explosive and corrosive gases.
3) Have reliable earthling set when use.
4) In case of damage or breakdown, should consult qualified technician.
5) Clean air curtain periodically. Note: Do Not clean unit with benzene or corrosive liquid.
WARNING: UNPLUG POWER BEFORE CLEANING!!!!
7. Installation for Micro Door Switch for Automatic Start/Stop
See attached instruction guide comes with Micro Door Switch
or available at www.YOSHIMASAUSA.com
8. Remote Control (optional)
Remote control is available at www.YOSHIMASAUSA.com or call at 1(800)789-9835
Remote Control
[YMAC36-Remote, YMAC48-Remote,YMAC60-Remote]
* YOSHIMASAUSA has the right to change specifications without prior notice.
WARRANTY CERTIFICATE
Warranty Valid Only In USA & CANADA
Warranty Information
1Year parts and labor Warranty In USA & CANADA
Warranty Claims
All labor claims or parts must include copy of original invoice submitted directly to YOSHIMASAUSA. All claims must include: a copy of original invoice (Customer Name, Customer Address, Model Name, and Date of Sale), Customer Name, Address, Phone Number, Model and Serial Number of the unit, Date of Sale, Distributor Name, and a Brief Description of Complai n t. On all compressor warranties the compressor model tag must be returned to YOSHIMASAUSA along with the above listed information. All claims must be reported to YOSHIMASAUSA within one (1) year of occurrence
What Is Not Covered By This Warranty
Warranty Is Not Transferable- This warranty is not assignable and applies only to the original purchaser/user to whom delivered. Any such assignment or transfer will void this warranty and all other warranties implied. Improper Usage- YOSHIMASAUSA is not liable in any way for parts or labor coverage for component failure or other damages resulting from improper usage or installation or failure to clean and/or maintain product. Outside U.S. - This warranty does not apply to, and YOSHIMASAUSA is not responsible for, any warranty claims made on products sold or used outside the United States.
Improper Electrical Connections- YOSHIMASAUSA is not responsible for the repair or replacement of failed or
damaged components resulting from electrical power failure, the use of extension cords, low voltage, or voltage interference to the unit.
SALES TERMS AND CONDITIONS
Warranty Valid Only In USA
Freight Classes & Weights
All YOSHIMASAUSA products ship under various classifications and all weights are approximate.
YOSHIMASAUSA is not responsible for any variations thereof. YOSHIMASAUSA will make every attempt to
ship only by responsible and preferred carriers.
Customer’s Freight Damage Procedure
Before signing the UPS or carrier’s freight bill the customer should do the following:
VISIBLE DAMAGE:
1. Inspect shipment for ANY possible damage. If you are suspicious in any way
then mark the carrier’s copy of the freight bill “damaged”. (DO NOT SEND IT BACK TO US UNTIL WE GIVE PERMISSION TO DO SO)
2. Make sure that the condition of the damage is noted on your copy of the freight bill and signed by
the driver.
3. Ask them to send their agent to complete an inspection report.
4. Action must be taken by you to notify the carrier within 48 hours upon receipt. It is the
responsibility of the carrier to provide you with a written report. After notifying the carrier and filing a damage report, then you should notify us.
5. Be sure to keep ALL cartons and merchandise for inspection.
CONCEALED DAMAGE
1. Action must be taken by you to notify the carrier within 48 hours upon receipt. After notifying the
carrier and filing a damage report, then you should notify us.
2. Request for the carrier to send their agent to complete an inspection report immediately.
3. Be sure to keep ALL cartons and merchandise for inspection. (DO NOT SEND IT BACK TO US
UNTIL WE GIVE PERMISSION TO DO SO)
4. Styrofoam may hide any hidden dents on the shipment that may not be visible. You must inspect
all corners and grills thoroughly.
ALL UNITS ARE INSPECTED AT THE WAREHOUSE PRIOR TO SHIPPING AND ARE CHECKED FOR ANY DAMAGES THOROUGHLY BEFORE BEING RELEASED!!! Product Returns
It is mandatory that returned product(s) and/or parts must be shipped prepaid, packed in the original carton, and be received in GOOD condition to be authorized credit to your account by YOSHIMASAUSA . Do not send the damaged equipment back to YOSHIMASAUSA until you retain permission to do so. If you do, NO credit will be applied to your account and you will be held completely responsible for ALL returning shipping costs.
www.YOSHIMASAUSA.com