York YMA024 User Manual

TECHNICAL GUIDE
AFFINITY R-22 SPLIT-SYSTEM HEAT PUMPS 12 SEER MODELS: YMA024 THRU 060
(2 THRU 5 NOMINAL TONS)
O
T
A
D
R
E
I
I
A
F
S
I
T
R
C
E
O
C
M
P
R
L
E
Y
H
E
I
Y
R
A
R
T
A
C
E
R
A
T
I N
U
E
T
I
F
I
C
A
R
I
S
T
WITH ARI.
N
G
P
U
M P
R
T
Q
F
N
U
E
I
P
M
O
S
N
O
I
T
C
E
T
S
I
0
N
O
4
2
D
A
R
N
A
D
ISO 9001
Certified Quality
Management System
U
T C
A
F
U N
A
M
CERTIFICATIONAPPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
LISTED
Due to continuous product improvement, specific ations are subject to change without notice.
Visit us on the web at www.york.com for the most up-to-date technical information.
Additional rating information can be found at www.ariprimenet.org.
036-21570-002 Rev. D (0605)
DESCRIPTION
The YMA Series unit is the outdoor part of a versatile hea t pump system. It is designed to be custom matched with one of our complete line of evaporator sections, each designed to serve a specific function. Matching air handlers are available for upflow, downflow, and horizontal left or right application to provide a complete system. Electric heaters are available if required. Add­on coils are available for use with upflow, downflow, or horizon­tal furnaces. Field installed accessories are available as needed.
WARRANTY
5-year limited parts warranty. 10-year limited compressor warranty.
FEATURES
Superior Coil Protection – A stamped decorative metal coil guard completely protects coil from debris and other large damaging material while a polymer mesh further protects the coil against smaller particles.
Color Grilles - Engineered around the needs and wants of the consumer, Af fi nity unit s are now a vailab le wi th a ch oice of color options designed to compliment any home.
Protected Compressors – Each compressor is protected against abnormal pressures by an internal pressure relief valve and factory installed high pressure controls. Additional protection against moisture and debris is provided by factory installed liquid line filter driers.
Durable Finish – Automotive quality finish provides the ulti­mate protection from harmful U.V. rays and rust creep ensur­ing long-lasting, high quality appearance. A powder-paint topcoat is applied over a baked-on primer, using a galva­nized, zinc coated steel base material. The result is a finish that has been proven in testing to provide 33% greater dura­bility than conventional powder-coat finishes.
Lower Installed Cost – Designed to provide enhanced installability by featuring a slide-down control compartment and angled service valves to reduce overall installation time and cost.
Low Operating Sound Levels – Unit discharges upward to reduce sound transmission. An integrated fan venturi reduces fan sound levels even further. An isolator-mounted compressor covered by a sound-deadening blanket which is mounted to a composite polymer base pan insures unwanted compressor noises are not introduced into the environment.
Filter-Drier – A factory installed, solid core liquid line filter­drier filters harmful debris and moisture from the system.
Easy Service Access – A full end, full service, access panel with handle makes for easy entry to internal components.
Long Lasting Operation – Strong and durable composite base pan provides added strength while resisting rust and corrosion as well as reducing sound and vibration.
Complete System Control – These heat pumps utilize the unique microprocessor defrost control system to provide opti­mal comfort and to monitor the overall system for reliable operation. The defrost control system continuously monitors the space environment to maintain optimum efficiency. It ini­tiates defrost only when necessary to further reduce heating costs and improve reliability. In the event improper operating conditions occur, the control will automatically shut the sys­tem down to extend the life of the heat pump. Rapid cycling is prevented by use of an internal anti-recycle timer.
Composite Base - Strong and durable composite base pan resists rust and corrosion while it helps reduce vibrations and noise.
Low RPM fan motor - Helps to reduce airflow noise.
Certified in accordance with the Unitary Small Equipment certifi­cation program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
036-21570-002 Rev. D (0605)
Physical and Electrical Data
MODEL
Unit Supply Voltage 208-230V, 1φ, 60Hz Normal Voltage Range
Minimum Circuit Ampacity 14.3 18.1 21.9 32.6 34.7 39.0 Max. Overcurrent Device Amps
Compressor Type Recip Recip Recip Scroll Scroll Scroll Compressor Amps Crankcase Heater Yes Yes Yes No No No
Fan Motor Amps Rated Load 0.5 1.5 1.5 1.5 1.5 1.5 Fan Diameter Inches 22 22 22 22 22 22
Fan Motor
Coil
Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 7/8 7/8 7/8 1-1/8
Unit Charge (Lbs. - Oz.) Charge Per Foot (Oz.) 0.68 0.68 0.70 0.70 0.70 0.78 Operating Weight (Lbs.) 175 220 225 225 245 285
1 Rated in accordance with ARI Standard 110, utilization range “A”. 2 Dual element fuses or HACR circuit breaker. 3 The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
1
2
Rated Load 11.1 13.3 16.4 24.9 26.6 30 Locked Rotor 60 68 78 115 150 150
Rated HP 1/15 1/4 1/4 1/4 1/4 1/4 Nominal RPM 850 850 850 850 850 850 Nominal CFM 2,300 3,500 3,500 3,850 3,500 3,300 Face Area (Sq. Ft.) 14.86 17.15 20.58 20.58 20.58 20.58 Rows Deep 111112 Fins / Inch 22 22 22 22 22 22
3
YMA02411 YMA03011 YMA03611 YMA04211 YMA04811 YMA06011
187 to 252
25 30 35 50 60 60
7 - 2 7 - 12 8 - 6 8 - 12 9 - 1 14 - 2
VAPOR
LIQUID
2-3/8
3-1/8
6-1/2
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
DIMENSIONS
Unit
Model
A
Dimensions
A
(Inches)
B C Liquid Vapor
024 29-1/2 37 31 030 33-1/2 37 31
C
B
036 39-1/2 37 31
048 39-1/2 37 31 060 39-1/2 37 31 7/8” *
* Expander fitting required for 1-1/8” line set.
Refrigerant Connection
Service Valve Size
3/4”
3/8”
7/8”042 39-1/2 37 31
2 Unitary Products Group
036-21570-002 Rev. D (0605)
Additional R-22 Charge / TXV Size for Various Matched Systems
Outdoor Unit YMA02411 YMA03011 YMA03611 YMA04211 YMA04811 YMA06011 Unit Orifice (s) 63 69 78 87 - 96
Approved System Thermal Expansion Valve Factory R-22 Charge, lbs-oz 7 - 2 7 - 12 8 - 6 8 - 12 9 - 1 14 - 2
Indoor Coil
3
Coil Orifice G2FD030(S,H)17 65 63/(701) + 2 69/(701) + 0 - - ­G2FD035(S,H)14 65 63/(701) + 2 69/(701) + 0 - - ­G2FD036(S,H)17 65 - - 78/(702) + 3 - - ­G2FD036(S,H)21 75 - - 78/(702) + 5 - - ­G2FD048(S,H)21,24 84 - - - 87/(702) + 3 - ­G2FD060(S,H)24 90 ----703 + 6 96 + 6 G2FD061H24 90 ----703 + 12 96 + 12 G1HA036H14 75 63/(701) + 8 69/(701) + 6 78/(702) + 5 - - ­G1HA036H17 78 63/(701) +12 69/(701) + 9 78/(702) + 8 - - ­G1HA048H21 84 - - - 87/(702) + 4 - ­G1HA060H24 90 ----703 + 6 96 + 6 G1HD036 69 63/(701) + 8 69/(701) + 5 78/(702) + 5 - - ­G1HD048 81 - - - 87/(702) + 0 - ­G1HD060 93 ----703 + 0 96 + 0 G1NA036S17J 67 63/(701) + 4 69/(701) + 2 78/(702) + 1 - - ­G1NA036S21C 67 63/(701) + 4 69/(701) + 2 78/(702) + 1 - - ­G1NA060S24T 87 - - - 87/(702) + 8 703 + 1 96 + 0 G1FA/G1UA036S14 73 63/(701) + 4 69/(701) + 2 78/(702) + 1 - - ­G1FA/G1UA036S17,21 73 63/(701) + 2 69/(701) + 0 78/(702) + 0 - - ­G1FA/G1UA048S21 84 - - - 87/(702) + 5 - ­G1FA/G1UA060S21,24 90 ----703 + 6 96 + 6 F2RC/F2FC036 75 63/(701) + 2 69/(701) + 0 ---­F2RP024 61 63/(701) + 0 ----­F2RP/F2FP030 65 63/(701) + 2 69/(701) + 0 ---­F2RP/F2FP036 75 - - 78/(702) + 5 - - ­F2FP040 63 - - 78/(702) + 8 - - ­F2RP/F2FP042 78 - - 78/(702) + 8 - - ­F2FP045 78 ----703 + 6 ­F2FP048 84 - - - 87/(702) + 7 - ­F2FP060 90 ----703 + 6 96 + 6 F2FV060 90 ----703 + 6 96 + 6
Indoor Coil with factory installed TXV
2,4
Factory installed
coil orifice G2FD030(S,H)17T - 2 0 - - ­G2FD035(S,H)14T - 2 0 - - ­G2FD036(S,H)17T - - - 3 - - ­G2FD036(S,H)21T - - - 5 - - ­G2FD060(S,H)24T - ----6 ­G1HA036H14T - - - 5 - - ­G1HA036H17T - - - 8 - - ­G1HA060H24T - ----6 ­G1FA/G1UA036S14T - - - 1 - - ­G1FA/G1UA036S17,21T - - - 0 - - ­G1FA/G1UA060S21,24T - ----6 ­F3RP024 - 0 ----­F3RP030 - 2 0 ---­F3RP036 - - - 5 - - ­F3RP042 - - - 8 - - ­F3FP040 - - - 8 - - ­F3FP060 - ----6 ­F3FV060 - ----6 -
FOOTNOTES:
1 Only the TXV kits listed above are approved for use in these systems. The charge adder is the same as that listed for the orifice. 2 Models with recipr oca ting compressors requir e start kits when matched to TXV indoor coils.
3 Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit
2FD06700224.
4 These orifices or TXVs are factory mounted in the flow device of each indoor coil (701, 702, 703 indicates 1TV07…series). A “T”
suffix indicates a coil or air handler with a factory mounted TXV.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter­connecting line tubing.
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified on the previous page.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.
1,2
3
1TV0701 1TV0701 1TV0702 1TV0702 1TV0703 -
4
Orifice - Additional Charge, Oz
Additional Charge, Oz.
Unitary Products Group 3
036-21570-002 Rev. D (0605)
COOLING CAPACITY - With Air Handler Coils
MODEL
AIR HANDLER
ELECTRIC
2
HEAT KW
W
1 PH 12 SEER HP WITH N1AH / G2FD
1 PH 12 SEER HP / N1VS - VARIABLE SPEED
1 PH 12 SEER HP / F2RP / RC / FP / FC / FV
UNIT
MODEL
YMA02411
YMA03011
YMA03611
YMA04211
YMA04811
YMA06011
YMA02411 N1VSB12 2,5,8,10 17 G2FD030(S,H)17(T) 775 24.2 18.5 13.00 13.00 11.95 YMA03011 N1VSB12 2,5,8,10 17 G2FD030(S,H)17(T) 1000 30.2 22.8 13.00 13.00 11.95
YMA03611
YMA04211
YMA04811
YMA06011
YMA02411
YMA03011
YMA03611
YMA04211
YMA04811 F2FP045 5,8,10,15 24 - 1600 45.5 34.5 - 12.00 10.20
YMA06011
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temp erature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the to tal cooling output in BTU’s at 95°F outdoor ambient divid ed by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a nor mal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
N1AHB08 2,5,8,10 17 G2FD030(S,H)17(T) 800 24.0 18.8 12.00 12.00 10.90 N1AHB12 2,5,8,10 17 G2FD030(S,H)17(T) 800 24.0 18.8 12.00 12.00 10.90 N1AHB08 2,5,8,10 17 G2FD030(S,H)17(T) 1000 30.0 23.0 12.00 12.00 11.10 N1AHB12 2,5,8,10 17 G2FD030(S,H)17(T) 1000 30.0 23.0 12.00 12.00 11.10 N1AHB08 2,5,8,10 17 G2FD036(S,H)17(T) 1200 35.2 27.2 12.00 12.00 11.05 N1AHB12 2,5,8,10 17 G2FD036(S,H)17(T) 1200 35.2 27.2 12.00 12.00 11.05 N1AHC16 5,8,10,15,20 21 G2FD036(S,H)21(T) 1200 35.6 28.0 12.00 12.00 11.30 N1AHC16 5,8,10,15,20 21 G2FD048(S,H)21(T) 1400 42.0 32.8 12.00 12.00 10.70 N1AHD20 8,10,15,20,25,30 24 G2FD048(S,H)24(T) 1400 42.0 32.8 12.00 12.00 10.70 N1AHD20 8,10,15,20,25,30 24 G2FD060(S,H)24(T) 1600 46.0 35.6 - 12.00 10.20 N1AHD20 8,10,15,20,25,30 24 G2FD061H24 1600 46.0 36.0 - 12.00 10.25 N1AHD20 8,10,15,20,25,30 24 G2FD060(S,H)24(T) 1800 54.0 42.2 11.70 - 10.50 N1AHD20 8,10,15,20,25,30 24 G2FD061H24 1800 54.5 42.4 12.00 - 10.55
N1VSB12 2,5,8,10 17 G2FD036(S,H)17(T) 1200 35.4 26.8 12.50 12.50 11.65 N1VSC16 5,8,10,15,20 21 G2FD036(S,H)21(T) 1200 36.0 27.6 13.00 13.00 12.20 N1VSC16 5,8,10,15,20 21 G2FD048(S,H)21(T) 1380 42.5 32.4 13.00 13.00 11.45 N1VSD20 8,10,15,20,25,30 24 G2FD048(S,H)24(T) 1350 42.5 32.0 13.00 13.00 11.40 N1VSD20 8,10,15,20,25,30 24 G2FD060(S,H)24(T) 1600 46.0 35.0 - 12.50 10.65 N1VSD20 8,10,15,20,25,30 24 G2FD061H24 1600 46.5 35.4 - 12.50 10.70 N1VSD20 8,10,15,20,25,30 24 G2FD060(S,H)24 1780 53.5 40.6 12.00 - 10.65 N1VSD20 8,10,15,20,25,3 24 G2FD061H24 1780 54.5 41.4 12.10 - 10.85
F2RC/F2FC036 5,8,10,15 18 - 800 24.0 18.8 12.00 12.00 10.90 F2RP/F2FP/F3FP024 5,8,10,15 18 - 800 23.6 18.6 12.00 12.00 10.90 F2RP/F2FP/F3FP030 5,8,10,15 18 - 800 24.0 18.8 12.00 12.00 10.90
F2RC/F2FC036 5,8,10,15 21 - 1000 29.6 22.2 12.00 12.00 11.05 F2RP/F2FP/F3FP030 5,8,10,15 21 - 1000 29.6 22.2 12.00 12.00 11.05
F2FP/F3FP040 5,8,10,15 21 - 1200 36.0 27.2 12.00 12.00 11.30 F2RP/F2FP/F3FP036 5,8,10,15 21 - 1200 35.8 27.0 12.00 12.00 11.20 F2RP/F2FP/F3FP042 5,8,10,15 21 - 1200 36.0 27.2 12.00 12.00 11.30
F2FP048 5,8,10,15,20,25 24 - 1400 41.5 31.8 12.00 12.00 10.55
F2FP/F3FP060 8,10,15,20,25 24 - 1600 45.5 34.2 - 11.50 10.00
F2FP060 8,10,15,20,25 24 - 1800 53.0 40.4 11.25 - 10.25 F2FV060 8,10,15,20,25 24 - 1780 54.0 40.8 12.00 - 10.75
COIL
MODEL
1
RATED
CFM
TOTAL
CAPACITY
3,4
COOLING
SENSIBLE CAPACITY
SEER
W/O TXV
SEER
W/ TXV
EER
1 G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2 Single phase units require single phase 2HK heaters.
3 To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC 4 FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard.
. models. All ratings remain the same.
** Refer to Quick Selection Chart for specific furnace match-up.
4 Unitary Products Group
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
UNIT MODEL
CFM RANGE
(MIN.-MAX.)
WRATED CFM
14 G1FA036S14 800 24.2 19.1 12.00 12.00 11.00
17,21 G1FA036S17,21 800 24.0 18.8 12.00 12.00 10.90
17 G2FD030(S,H)17(T) 800 24.0 18.8 12.00 12.00 10.90
FURNACE**
14 G2FD035(S,H)14(T) 800 24.0 18.8 12.00 12.00 10.90 17 G1NA036S17J 800 24.2 18.8 12.00 12.00 11.00 21 G1NA036S21C 800 24.2 18.8 12.00 12.00 11.00
YMA02411
600
1000
- G1HD036 800 24.4 19.3 12.00 12.00 11.10 14 G1HA036H14 760 24.6 18.8 12.00 12.00 11.20 17 G1HA036H17 760 24.6 18.9 12.00 12.00 11.25
17,21 G1FA036S14 1000 30.2 23.1 12.00 12.00 11.20 17,21 G1FA036S17,21 1 000 30.0 23.0 12.00 12.00 11.10
17 G2FD030(S,H)17(T) 1000 30.0 23.0 12.00 12.00 11.10 14 G2FD035(S,H)14(T) 1000 30.0 23.0 12.00 12.00 11.10 17 G1NA036S17J 1000 30.4 23.0 12.00 12.00 11.25 21 G1NA036S21C 1000 30.4 23.0 12.00 12.00 11.25
YMA03011
800
1200
- G1HD036 1000 30.6 23.4 12.00 12.00 11.30 14 G1HA036H14 950 30.8 23.0 12.00 12.00 11.45 17 G1HA036H17 950 31.0 23.2 12.00 12.00 11.45 14 G1FA036S14(T) 1200 34.8 27.0 12.00 12.00 10.95
17,21 G1FA036S17,21(T) 1200 34.6 27.0 12.00 12.00 10.95
17 G2FD036(S,H)17(T) 1200 35.2 27.2 12.00 12.00 11.05 21 G2FD036(S,H)21(T) 1200 35.6 28.0 12.00 12.00 11.30 17 G1NA036S17J 1200 35.2 26.6 12.00 12.00 11.05 21 G1NA036S21C 1200 35.2 26.6 12.00 12.00 11.05
YMA03611
1000 1400
- G1HD036 1200 35.4 27.4 12.00 12.00 11.10 14 G1HA036H14(T) 1140 35.6 27.2 12.00 12.00 11.30 17 G1HA036H17(T) 1140 35.8 27.4 12.00 12.00 11.40 21 G1FA048S21 1400 42.0 32.6 12.00 12.00 10.65
21,24 G2FD048(S,H)21,24 1400 42.0 32.8 12.00 12.00 10.70
24 G1NA060S24T 1400 42.5 33.0 12.00 12.00 10.90
- G1HD048 1400 41.5 32.4 12.00 12.00 10.60
YMA04211
1200 1600
21 G1HA048H21 1330 41.5 31.6 12.00 12.00 10.60
21,24 G1FA060S21,24(T) 1600 46.0 35.6 - 12.00 10.20
24 G2FD060(S,H)24(T) 1600 46.0 35.6 - 12.00 10.20
YMA04811
1400 1800
24 G2FD061H24 1600 46.0 36.0 - 12.00 10.25 24 G1NA060S24T 1600 45.5 34.8 - 11.75 10.10
- G1HD060 1600 45.0 35.0 - 11.75 10.10 24 G1HA60H24(T) 1520 45.5 34.8 - 12.00 10.20
21,24 G1FA060S21,24 1800 54.0 42.2 11.70 - 10.50
24 G2FD060(S,H)24 1800 54.0 42.2 11.70 - 10.50
YMA06011
1600 2000
24 G2FD061H24 1800 54.5 42.4 12.00 - 10.55 24 G1NA060S24T 1800 53.0 40.6 11.50 - 10.40
- G1HD060 1800 53.0 41.1 11.50 - 10.35 24 G1HA60S24 1710 53.5 40.9 11.70 - 10.50
1 Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. 2 TXV = Use 1TV0700 series kit. ** Refer to Quick Selection Chart for specific furnace match-up.
COIL
MODEL
TOTAL
CAPACITY
SENSIBLE CAPACITY
COOLING
SEER W/O TXV
036-21570-002 Rev. D (0605)
SEER W/TXV
1,2
+ TDR
+ TDR
EER
Unitary Products Group 5
036-21570-002 Rev. D (0605)
COOLING CAPACITY - With Variable Speed Furnaces
UNIT
MODEL
YMA02411
YMA03011
YMA03611
YMA04211
For notes see Page 7.
VARIABLE SPEED FURNACE MODEL
COIL
MODEL
W
1
RATED
CFM
1 PH 12 SEER HP / P1DU / P1XD / P1XU - VARIABLE SPEED
P*DUA12V G1FA036S14 14 750 24.4 18.5 13.00 13.00 11.95 P*DUA12V G2FD035(S,H)14(T) 14 750 24.2 18.5 13.00 13.00 11.90 P*DUB16V G1FA036S17 17 795 24.4 19.0 13.00 13.00 11.95 P*DUB16V G2FD030(S,H)17(T) 17 795 24.4 19.0 13.00 13.00 11.95 P*DUC20V G1FA036S21 21 800 24.4 19.0 13.00 13.00 11.95 P1XUB12V G1FA036S17 17 800 24.4 19.0 13.00 13.00 11.90
P1XUB12V G2FD030(S,H)17(T) 17 800 24.4 19.0 13.00 13.00 11.90 P1XUC16V G1FA036S21 21 770 24.2 18.6 13.00 13.00 11.95 P1XUC20V G1FA036S21 21 790 24.4 18.9 13.00 13.00 12.05
P1XDB12V G2FD030(S,H)17(T) 17 815 24.4 19.2 13.00 13.00 11.95
P1XDB12V G1HA036H17 17 760 24.6 18.9 13.00 13.00 11.95
P*DUB16V G1FA036S17 17 1050 30.6 23.8 13.00 13.00 12.10
P*DUA12V G1FA036S14 14 975 30.2 22.8 13.00 13.00 11.85
P*DUB16V G1FA036S17 17 1050 30.6 23.8 13.00 13.00 12.10
P*DUB16V G2FD030(S,H)17(T) 17 1050 30.6 23.8 13.00 13.00 12.10
P*DUC20V G1FA036S21 21 1000 30.4 23.2 13.00 13.00 12.10
P1XUB12V G1FA036S17 17 1020 30.4 23.4 13.00 13.00 11.80
P1XUB12V G2FD030(S,H)17(T) 17 1020 30.4 23.4 13.00 13.00 11.80 P1XUC16V G1FA036S21 21 1000 30.4 23.2 13.00 13.00 12.10 P1XUC20V G1FA036S21 21 990 30.4 23.0 13.00 13.00 12.05
P1XDB12V G2FD030(S,H)17(T) 17 1000 30.2 23.2 13.00 13.00 11.75
P1XDB12V G1HA036H17 17 950 31.0 23.2 13.00 13.00 11.50
P*DUA12V G1FA036S14(T) 14 1185 35.0 27.0 12.25 12.25 11.30
P*DUB16V G1FA036S17(T) 17 1200 35.0 27.2 12.50 12.50 11.65
P*DUB16V G2FD036(S,H)17(T) 17 1200 35.6 27.6 12.75 12.75 11.75
P*DUC20V G1FA036S21(T) 21 1200 35.2 27.2 12.50 12.50 11.75
P*DUC20V G2FD036(S,H)21(T) 21 1200 36.0 28.4 13.00 13.00 12.20
P1XUB12V G1FA036S17(T) 17 1200 35.0 27.0 12.25 12.25 11.40
P1XUB12V G2FD036(S,H)17(T) 17 1200 35.4 27.4 12.25 12.25 11.40 P1XUC16V G1FA036S21(T) 21 1200 35.0 27.2 12.50 12.50 11.65 P1XUC16V G2FD036(S,H)21(T) 21 1200 36.0 28.2 13.00 13.00 12.05 P1XUC20V G1FA036S21(T) 21 1200 35.0 27.2 12.50 12.50 11.70 P1XUC20V G2FD036(S,H)21(T) 21 1200 36.0 28.4 13.00 13.00 12.15
P1XDB12V G2FD036(S,H)17(T) 17 1200 35.4 27.4 12.25 12.25 11.35
P1XDB12V G1HA036H17(T) 17 1140 36.0 27.4 12.50 12.50 11.40 P1XDC20V G2FD036(S,H)21(T) 21 1225 36.0 28.6 13.00 13.00 11.80
P*DUC20V G1FA048S21 21 1400 42.0 32.8 12.50 12.50 11.15
P*DUC20V G2FD048(S,H)21(T) 21 1400 42.5 33.2 12.50 12.50 11.25 P1XUC16V G1FA048S21 21 1400 42.0 32.8 12.50 12.50 11.10 P1XUC16V G2FD048(S,H)21(T) 21 1400 42.5 33.2 12.50 12.50 11.25 P1XUC20V G1FA048S21 21 1410 42.0 32.8 12.25 12.25 11.05 P1XUC20V G2FD048(S,H)21(T) 21 1410 42.5 33.4 12.50 12.50 11.20 P1XDD20V G2FD048(S,H)24(T) 24 1430 42.5 33.4 12.25 12.25 11.00 P1XDC20V G2FD048(S,H)21(T) 21 1425 42.5 33.2 12.25 12.25 10.80 P1XDC20V G1HA048H21 21 1330 41.5 31.6 12.25 12.25 10.70 P1XDD20V G2FD048(S,H)24(T) 24 1420 42.5 33.2 12.50 12.50 11.05
TOTAL
CAPACITY
SENSIBLE CAPACITY
COOLING
SEER
W/O TXV +TDR
3
SEER/
W/TXV +TDR
EER
2
6 Unitary Products Group
COOLING CAPACITY - With Variable Speed Furnaces (Continued)
UNIT
MODEL
YMA04811
YMA06011
1 G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2 TXV = Use 1TV0700 Series Kit. 3 Variable speed furnaces have B.O.D (Blower on Delay) standard. 4 G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 5 TXV = Use 1TV0700 Series Kit. 6 Variable speed furnaces have B.O.D (Blower on Delay) standard.
VARIABLE SPEED FURNACE MODEL
COIL
MODEL
W
4
RATED
CFM
TOTAL
CAPACITY
SENSIBLE CAPACITY
1 PH 12 SEER HP / P1DU / P1XD / P1XU - VARIABLE SPEED
P*DUC20V G1FA060S21(T) 21 1610 46.0 35.8 - 12.10 10.40 P*DUC20V G2FD060(S,H)24(T) 24 1610 46.0 35.8 - 12.10 10.40
P*DUC20V G2FD061H24 24 1500 46.0 36.2 - 12.50 10.65 P1XUC16V G1FA060S21(T) 21 1600 46.0 35.6 - 12.05 10.20 P1XUC16V G2FD060(S,H)24(T) 24 1600 46.0 35.6 - 12.05 10.20 P1XUC16V G2FD061H24 24 1600 46.0 36.0 - 12.10 10.30 P1XUC20V G1FA060S21(T) 21 1590 46.0 35.6 - 12.10 10.35 P1XUC20V G2FD060(S,H)24(T) 24 1590 46.0 35.6 - 12.10 10.35 P1XUC20V G2FD061H24 24 1450 46.0 36.0 - 12.50 10.65 P1XUD20V G1FA060S24(T) 24 1620 46.0 35.8 - 12.10 10.35 P1XUD20V G2FD060(S,H)24(T) 24 1620 46.0 35.8 - 12.10 10.35 P1XUD20V G2FD061H24 24 1500 46.0 36.4 - 12.50 10.70 P1XDC20V G2FD060(S,H)24(T) 24 1575 45.5 35.4 - 12.05 10.25 P1XDC20V G1HA60H24(T) 24 1450 45.5 34.8 - 12.10 10.35 P1XDD20V G2FD060(S,H)24(T) 24 1610 46.0 35.8 - 12.10 10.30 P1XDD20V G2FD061H24 24 1610 46.5 36.2 - 12.10 10.40 P1XDD20V G1HA60H24(T) 24 1520 45.5 34.8 - 12.10 10.40 P*DUC20V G1FA060S21 21 1730 53.5 41.2 12.00 - 10.60 P*DUC20V G2FD060(S,H)24 24 1730 53.5 41.2 12.00 - 10.60 P*DUC20V G2FD061H24 24 1730 54.0 41.9 12.00 - 10.70 P1XUC16V G1FA060S21 21 1600 53.5 40.0 12.00 - 10.60 P1XUC16V G2FD060(S,H)24 24 1600 53.5 40.0 12.00 - 10.60 P1XUC16V G2FD061H24 24 1600 53.5 40.3 12.00 - 10.65 P1XUC20V G1FA060S21 21 1640 53.5 40.1 12.00 - 10.60 P1XUC20V G2FD060(S,H)24 24 1640 53.5 40.1 12.00 - 10.60 P1XUC20V G2FD061H24 24 1640 54.0 40.8 12.00 - 10.70 P1XUD20V G1FA060S24 24 1620 53.5 40.0 12.00 - 10.60 P1XUD20V G2FD060(S,H)24 24 1620 53.5 40.0 12.00 - 10.60 P1XUD20V G2FD061H24 24 1620 54.0 40.6 12.00 - 10.85 P1XDC20V G2FD060(S,H)24 24 1575 53.5 39.7 12.00 - 10.60 P1XDC20V G1HA60H24 24 1520 53.0 39.1 12.00 - 10.70 P1XDD20V G2FD060(S,H)24 24 1610 53.5 39.8 12.00 - 10.65 P1XDD20V G2FD061H24 24 1610 54.0 40.4 12.00 - 10.75 P1XDD20V G1HA60H24 24 1520 53.0 39.1 12.00 - 10.70
036-21570-002 Rev. D (0605)
COOLING
SEER
W/O TXV +TDR
6
SEER/
W/TXV +TDR
EER
5
Unitary Products Group 7
036-21570-002 Rev. D (0605)
HEATING PERFORMANCE - With Air Handler
UNIT
MODEL*
YMA02411
YMA03011
YMA03611
YMA04211
YMA04811
YMA06011
YMA02411 N1VSB12 G2FD030(S,H)17(T) 23.4 3.70 1.85 13.3 2.64 1.48 8.50 6.5 1.23 9.9 1.36 15.4 1.55 17.4 1.62 26.9 1.98 YMA03011 N1VSB12 G2FD030(S,H)17(T) 29.4 3.46 2.49 17.5 2.60 1.97 8.50 9.6 1.63 13.6 1.81 20.1 2.10 22.6 2.22 33.5 2.67
YMA03611
YMA04211
YMA04811
YMA06011
YMA02411
YMA03011
YMA03611
YMA04211
YMA04811
YMA06011
1 Rated CFM same as for cooling. 2 Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental
electric heat operation.
3 Integrated heating capacities include the effect of defrost cycles in the temperat ure range where they occur.
COP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric
power input during the same period.
— = Not Applicable.
AIR
HANDLER
N1AHB08 G2FD030(S,H)17(T) 24.0 3.46 2.03 13.8 2.44 1.66 8.00 7.0 1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16 N1AHB12 G2FD030(S,H)17(T) 24.0 3.46 2.03 13.8 2.44 1.66 8.00 7.0 1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16 N1AHB08 G2FD030(S,H)17(T) 30.0 3.28 2.68 17.8 2.44 2.14 8.00 9.8 1.80 13.9 1.97 20.4 2.27 22.9 2.38 34.0 2.86 N1AHB12 G2FD030(S,H)17(T) 30.0 3.28 2.68 17.8 2.44 2.14 8.00 9.8 1.80 13.9 1.97 20.4 2.27 22.9 2.38 34.0 2.86 N1AHB08 G2FD036(S,H)17(T) 35.2 3.54 2.91 21.0 2.54 2.42 8.00 11.5 2.10 16.3 2.26 23.2 2.52 25.4 2.62 39.9 3.08 N1AHB12 G2FD036(S,H)17(T) 35.2 3.54 2.91 21.0 2.54 2.42 8.00 11.5 2.10 16.3 2.26 23.2 2.52 25.4 2.62 39.9 3.08 N1AHC16 G2FD036(S,H)21(T) 35.2 3.54 2.91 21.0 2.54 2.42 8.00 11.5 2.10 16.3 2.26 23.2 2.52 25.4 2.62 39.9 3.08 N1AHC16 G2FD048(S,H)21(T) 42.0 3.50 3.52 28.2 2.50 3.31 8.00 18.7 3.14 23.5 3.22 29.3 3.26 30.5 3.22 47.2 3.63 N1AHD20 G2FD048(S,H)24(T) 42.0 3.50 3.52 28.2 2.50 3.31 8.00 18.7 3.14 23.5 3.22 29.3 3.26 30.5 3.22 47.2 3.63 N1AHD20 G2FD060(S,H)24(T) 48.0 3.66 3.84 31.0 2.52 3.60 8.00 19.7 3.44 25.3 3.52 33.6 3.59 36.1 3.57 53.7 3.94 N1AHD20 G2FD061H24 48.0 3.66 3.84 31.0 2.52 3.60 8.00 19.7 3.45 25.4 3.53 33.7 3.60 36.3 3.58 53.9 3.95 N1AHD20 G2FD060(S,H)24(T) 59.0 3.72 4.65 36.2 2.58 4.11 8.00 21.0 3.75 28.6 3.93 38.9 4.14 41.5 4.18 66.6 4.83 N1AHD20 G2FD061H24 59.0 3.72 4.65 36.2 2.58 4.11 8.00 21.0 3.75 28.6 3.93 38.9 4.14 41.5 4.18 66.6 4.83
N1VSB12 G2FD036(S,H)17(T) 34.8 3.70 2.76 20.6 2.68 2.25 8.50 11.3 1.95 16.1 2.12 23.0 2.38 25.2 2.48 39.7 2.94 N1VSC16 G2FD036(S,H)21(T) 34.8 3.76 2.71 20.6 2.72 2.22 8.50 11.2 1.90 15.9 2.06 22.9 2.32 25.1 2.42 39.6 2.88 N1VSC16 G2FD048(S,H)21(T) 41.0 3.64 3.30 27.2 2.60 3.07 8.50 17.9 2.92 22.6 3.00 28.4 3.04 29.5 3.00 45.9 3.39 N1VSD20 G2FD048(S,H)24(T) 41.0 3.68 3.26 27.4 2.62 3.06 8.50 18.1 2.91 22.8 2.99 28.5 3.03 29.7 2.99 46.1 3.38 N1VSD20 G2FD060(S,H)24(T) 47.0 3.82 3.60 30.2 2.60 3.40 8.50 19.0 3.27 24.6 3.37 32.8 3.38 35.3 3.35 52.6 3.67 N1VSD20 G2FD061H24 47.5 3.80 3.70 30.8 2.64 3.42 8.50 19.5 3.27 25.2 3.36 33.5 3.42 36.0 3.41 53.7 3.78 N1VSD20 G2FD060(S,H)24 58.5 3.74 4.58 35.6 2.60 4.01 8.00 20.3 3.63 28.0 3.82 38.3 4.06 41.0 4.10 66.1 4.77 N1VSD20 G2FD061H24 58.5 3.74 4.58 35.6 2.60 4.01 8.00 20.3 3.63 28.0 3.82 38.3 4.06 41.0 4.10 66.1 4.77
F2RC/F2FC036 - 24.0 3.46 2.03 13.8 2.44 1.66 8.00 7.0 1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16 F2RP/F2FP/F3FP024 - 23.6 3.46 2.00 13.4 2.44 1.61 8.00 7.0 1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16 F2RP/F2FP/F3FP030 - 24.0 3.46 2.03 13.8 2.44 1.66 8.00 7.0 1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16
F2RC/F2FC036 - 30.0 3.30 2.66 17.6 2.42 2.13 8.00 9.4 1.80 13.6 1.97 20.2 2.26 22.7 2.38 34.2 2.84 F2RP/F2FP/F3FP030 - 30.0 3.32 2.65 17.6 2.42 2.13 8.00 9.4 1.80 13.6 1.97 20.2 2.26 22.7 2.38 34.2 2.83
F2FP/F3FP040 - 35.0 3.54 2.90 20.8 2.54 2.40 8.00 11.5 2.09 16.2 2.26 23.2 2.52 25.4 2.61 39.9 3.07 F2RP/F2FP/F3FP036 - 34.8 3.52 2.90 20.6 2.50 2.41 8.00 11.2 2.09 15.9 2.26 22.9 2.52 25.1 2.61 39.6 3.07 F2RP/F2FP/F3FP042 - 35.0 3.54 2.90 20.8 2.54 2.40 8.00 11.5 2.09 16.2 2.26 23.2 2.52 25.4 2.61 39.9 3.07
F2FP048 - 41.5 3.46 3.51 27.8 2.48 3.28 8.00 18.7 3.14 23.3 3.22 29.1 3.26 30.2 3.22 46.6 3.63
F2FP/F3FP060 - 47.5 3.58 3.89 30.8 2.48 3.64 8.00 19.6 3.46 25.2 3.55 33.4 3.62 35.9 3.60 53.4 3.99
F2FP045 - 47.5 3.68 3.78 30.8 2.54 3.55 8.00 19.6 3.46 25.2 3.55 33.4 3.62 35.9 3.60 53.4 3.99 F2FV060 - 47.0 3.82 3.60 30.2 2.60 3.40 8.50 19.0 3.27 24.6 3.37 32.8 3.38 35.3 3.35 52.6 3.67 F2FP060 - 59.0 3.72 4.65 36.2 2.58 4.11 8.00 21.0 3.75 28.6 3.93 38.9 4.14 41.5 4.18 66.6 4.83 F2FV060 - 58.5 3.74 4.58 35.6 2.60 4.01 8.00 20.3 3.63 28.0 3.82 38.3 4.06 41.0 4.10 66.1 4.77
COIL
MODEL
1
MBH COP KW MBH COP KW STD MBH KW MBH KW MBH KW MBH KW MBH KW
1 PH 12 SEER WITH N1VS - VARIABLE SPEE D
1 PH 12 SEER HP / F2RP / RC / FP / FC /FV
ARI HEATING
47 17.00 HSPF -3 7 27 37 57
1 PH 12 SEER HP WITH N1AH/G2FD
2
OUTDOOR TEMP
3
8 Unitary Products Group