Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
10-year limited compressor warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase fo r replacement or closing for new home construction.
LISTED
397855-YTG-G-0509
DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with accessories and documents to serve specific functions.
FEATURES
• Quality Condenser Coils - The coil is constructed of copper
tubing and enhanced aluminum fins for increased efficiency
and corrosion protection.
• Protected Compressor - The compressor is internally protected against high pressure, temperature, and externally by
a factory installed high pressure switch. This is accomplished
by the simultaneous operation of high pressure relief valve
and a temperature sensor which protects the compressor if
undesirable operating conditions occur. A liquid line filterdrier further protects the compressor.
• Durrable Finish - The cabinet is made of pre-painted steel.
The pre-treated galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep. Special
primer formulas and matted-textured finish insure less fading
when exposed to sunlight.
• Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
• Top D is c h ar g e - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. Thi s
allows compact location on multi-unit applications.
• Low Operating Sound Level - The upward air flow carries
the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the rippled fins of the condense r
coil muffle the normal fan motor and compressor operating
sounds.
• Low Maintenance - Long life permanently lubricated motorbearings need no annual servicing.
• Easy Service Access - Fully exposed refrigerant connec-
tions, and a single panel covering the electrical controls
make for easy servicing of the unit.
• Secured Service Valves - Secured re-usable service valves
are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
• Agency Listed - U.L. and C.U.L. listed - approved for o utdoor application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
397855-YTG-G-0509
B
C
A
Physical and Electrical Data
MODEL
YHJD18
S41S1
YHJD24
S41S1
YHJD30
S41S1
YHJD36
S41S1
YHJD42
S41S1
YHJD48
S41S1
YHJD60
S41S2
Unit Supply Voltage208-230V, 1 60Hz
Normal Voltage Range
Locked Rotor47.0 48.0 60.0 83.0 105.0 150.0 150.0
Crankcase HeaterYes Yes Yes Yes No No No
Fan Motor AmpsRated Load0.70 0.80 0.80 1.5 1.5 1.5 1.5
Fan Diameter Inches24 24 24 24 24 24 24
Rated HP1/10 1/8 1/8 1/4 1/4 1/4 1/4
Fan Motor
Nominal RPM825 1075 1075 850 850 850 850
Nominal CFM2200 2900 3100 3800 3800 3600 3600
Face Area Sq. Ft.15.7 18.3 21.0 23.58 23.58 23.58 23.6
Coil
Rows Deep1 1 1 1 1 2 2
Fin / Inches22 22 22 22 22 18 18
Liquid Line Set OD (Field Installed)3/8 3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD (Field Installed)3/4 3/4 3/4 3/4 7/8 7/8 7/8
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add
or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
Unit
Model
1828
Dimensions
(Inches)
1
A
BCLiquidVapor
3434
24323434
30363434
36403434
42403434
60403434
1. Including Fan Guard.
Refrigerant Connection
Service Valve Size
3/4”
3/8”
7/8”48403434
2Johnson Controls Unitary Products
System Charge for Various Matched Systems
Outdoor Unit YHJD18S41S1 YHJD24S41S1 YHJD30S41S1 YHJD36S41S1 YHJD42S41S1 YHJD48S41S1 YHJD60S41S2
Required Orifice or TXV
1. For applications requiring a TXV use 1TVM0 series kit.
2. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
3. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the cond enser, the smallest evaporator and 15 feet of interconnecting
line tubing.
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For TXV matches requiring additional charge, the refrigerant needs to be weighed in for specific coil match and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator +
adder for line set.
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BT U’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.