York YHJD Technical Guide

TECHNICAL GUIDE
LX SERIES SPLIT -SYSTEM HEAT PUMPS
14.5 SEER – R-410A – 1 PHASE
1.5 THRU 5 NOMINAL TONS
MODELS: YHJF18 THRU 60
Due to continuous product improvement, specifications are subject to change without notice.
Visit us on the web at
www.upgnet.com and www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY*
Extended 10-Years limited parts warranty. Standard 10-Years limited compressor warranty.
Extended 10-Years limited parts warranty requires online registration within 90 days of purchase for replacement or closing for new home construction.
*Does not apply to R-22 models, 3-Phase models, or internet sales. See Limited Warranty certificate in User's Information Manual for details.
®
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
561923-YTG-F-0114
DESCRIPTION
The 14.5 SEER Series unit is the outdoor part of a versatile cli­mate system. It is designed with a matching indoor coil compo­nent from Johnson Controls Unitary Products. Available for typical applications this climate system is supported with acces­sories and documents to serve specific functions.
FEATURES
Small Footprint - The compact footprint is a perfect fit for any application.
Quality Condenser Coils - The coil is constructed of copper tubing and enhanced aluminum fins for increased perfor­mance.
Coil Protection - Coils are protected from damage by a slot­ted, stamped steel coil guard.
Protected Compressor - Compressors are protected inter­nally by a high pressure relief valve and a temperature sen­sor, and externally by the system high and low pressure switches. A factory installed liquid line filter-drier further pro­tects the compressor against moisture and debris. The 5-ton system utilizes a two-stage compressor.
Environmentally Friendly Refrigerant - The next genera- tion refrigerant R-410A delivers environmentally friendly per­formance with zero ozone depletion.
Durable Finish - The cabinet is made of G90-equivalent pre­painted steel, with special primer formulas and matte cham­pagne texture to insure less fading when exposed to sun­light. The coated steel wire fan guard and pre-treated, galvanized steel chassis components resist corrosion and rust creep.
Lower Installed Cost - Installation time and costs are reduced by easy power and control wiring connections. The unit is factory charged for a 15-foot lineset. The small base dimension means less space is required on the ground or roof.
Top Discharge - Warm air from the top mounted fan is blown up, away from the structure and any landscaping. This allows compact location on multi-unit applications.
Quiet Operation - The compressor sound blanket and the swept wing fan blade keep sound to a minimum. The upward air flow carries the normal operating noise away from the liv­ing area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the condenser coil muffle the normal fan motor and compressor operating sounds.
Low Maintenance - Long life, permanently lubricated motor­bearings need no annual servicing.
Easy Service Access - Fully exposed refrigerant connec­tions and a single panel covering the electrical controls make for easy servicing of the unit.
Secured Service Valves - Secured, re-usable service valves are provided on both the liquid and vapor sweat con­nections for ease of evacuating and charging.
Advanced System Control - These heat pumps feature a demand-defrost control system to provide optimal comfort and reliable operation over a wide range of conditions.
Agency Listed - Safety certified by CSA to UL 1995 / CSA
22.2. Performance certified to ANSI/AHRI Standard 210/240 in accordance with the Unitary Small Equipment certification program.
561923-YTG-F-0114
B
C
A
Physical and Electrical Data
MODEL
YHJF18
S41S1
Unit Supply Voltage 208-230V, 1 60Hz Normal Voltage Range
Minimum Circuit Ampacity Max. Overcurrent Device Amps Min. Overcurrent Device Amps
Compressor Type Compressor
Amps Crankcase Heater
Factory External Discharge Muffler Factory External Check Valve
HS Kit Required with TXV Fan Motor Amps Rated Load Fan Diameter Inches
Fan Motor
Coil
Liquid Line Set OD (Field Installed) Vapor Line Set OD (Field Installed)
Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz.
1
2
3
Rated Load Locked Rotor
4
Rated HP Nominal RPM Nominal CFM Face Area Sq. Ft. Rows Deep Fins / Inch
5
11.9 17.6 17.3 19.7 23.7 28.5 35.3 20 30 30 30 40 50 60
15 20 20 20 25 30 40
Scroll Scroll Scroll Recip Scroll Scroll 2-Stage Scroll
9.0 13.4 12.8 14.7 17.9 21.8 35.3
48.0 58.3 64.0 74.0 112.0 117.0 118.0
No No No Yes No No No
Yes Yes Yes
No No No No No No No No No Yes No No No
24 22 24 24 24 24 24
1/10 1/8 1/4 1/4 1/4 1/4 1/4
0.7 0.8 1.3 1.3 1.3 1.3 1.3
825 1075 850 850 850 850 850
2000 2000 3900 3800 3600 3500 3800
15.72 19.17 23.58 23.58 23.58 23.58 23.58 1 1 1 1 1 2 2
22 22 22 22 22 18 18 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/4 3/4 3/4 3/4 7/8 7/8 1-1/8
6 - 15 7 - 14 9 - 14 10 - 6 11 - 4 13 - 1 14 - 2
0.62 0.62 0.62 0.62 0.67 0.67 0.75
Operating Weight Lbs. 145 145 176 193 198 248 290
1. Rated in accordance with AHRI Standard 110-2012, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Insta llation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, smallest matched indoor un it, and 15 fe et of ref rig erant t ubing . For tubin g leng ths other than 15 fe et, add or sub­tract the amount of refrigerant, using the difference in length multiplied by the per foot value.
YHJF24
S41S1
YHJF30
S41S1
YHJF36
S41S4
187 to 252
Combined
DM/CV
YHJF42
S41S5
YHJF48
S41S5
Yes Yes Yes
YHJF60
S41S1
Unit
Model
Dimensions
(Inches)
A B C Liquid Vapor
Refrigerant Connection
Service Valve Size
18 28-1/4 34 34 24 40-1/4 29-1/2 29-1/2 30 40-1/4 34 34 36 40-1/4 34 34 42 40-1/4 34 34
3/8
48 40-1/4 34 34 60 40-1/4 34 34
* Adapter Fitting Required for 1-1/8" Lilneset. All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard. Overall length and width include screw heads.
3/4
7/8
7/8
*
2 Johnson Controls Unitary Products
561923-YTG-F-0114
System Charge for Various Matched Systems
Outdoor Unit YHJF18S41S1 YHJF24S41S1 YHJF30S41S1 YHJF36S41S4 YHJF42S41S5 YHJF48S41S5 YHJF60S41S1 Required Orifice or TXV
Indoor Unit
3,4,5
1,2
AHE24B .051 / TXV + 0 .059 / TXV + 0 – AHE30B .051 / TXV + 0 .059 / TXV + 0 – AHE36C .063 / TXV + 0 .071 / TXV + 0 – AHE42D .071 / TXV + 5 – AHE48D .071 / TXV + 25 .075 / TXV + 0 TXV + 0 – AHE60D TXV + 8 TXV + 10 TXV + 0 AHR24B .051 / TXV + 0 .059 / TXV + 0 – AHR36B .063 / TXV + 0 .071 / TXV + 0 – AHR42C .071 / TXV + 5 – AHR48D .075 / TXV + 0 TXV + 0 – AHR60D – AHV24B .051 / TXV + 0 .059 / TXV + 0 – AHV30B .051 / TXV + 0 .059 / TXV + 0 – AHV36C .051 / TXV + 13 .059 / TXV + 12 .063 / TXV + 0 .071 / TXV + 0 – AHV42D .071 / TXV + 11 – AHV48D .071 / TXV + 31 .075 / TXV + 0 TXV + 0 – AHV60D TXV + 8 TXV + 10 TXV + 0 AV*36 .051 / TXV + 13 .059 / TXV + 12 .063 / TXV + 0 .071 / TXV + 0 – AV*48 .071 / TXV + 25 – FC/MC/PC32 .051 / TXV + 0 .059 / TXV + 0 – FC/MC/PC35 .051 / TXV + 0 .059 / TXV + 0 – FC/MC/PC37 .051 / TXV + 13 .059 / TXV + 12 .063 / TXV + 0 .071 / TXV + 0 – FC/MC/PC43 .051 / TXV + 13 .059 / TXV + 12 .063 / TXV + 0 .071 / TXV + 0 – FC/MC/PC48 .071 / TXV + 5 – FC/MC/PC60 .071 / TXV + 25 .075 / TXV + 0 TXV + 0 – FC/MC62 TXV + 8 TXV + 10 TXV + 0 FC64 TXV + 29 TXV + 8 UC48 .071 / TXV + 23 – UC60 .071 / TXV + 38 .075 / TXV + 4 – Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the “COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils” table.
FOOTNOTES:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. Approved orifice(s) shipped with outdoor unit.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blo w er Time Delay Kit S1-2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
5. Refer to Cooling and Heating Performance Data tables for actual performance for specified system matches.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includ es refrigerant for the o ut door unit, the smallest matched indoor uni t, and 15 feet of interconnect ing line t ubing.
2. Verify the TXV or orifice and additional charge required for specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for matched indoor unit + charge adder for line set.
.051/4F1 .059/4G1 .063/4G1 .071/4H1 .075/4J1 4K1 4K1
Additional Charge, Oz
Johnson Controls Unitary Products 3
561923-YTG-F-0114
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
YHJF18S41S1
YHJF24S41S1
YHJF30S41S1
YHJF36S41S4
For notes, see Page 5.
AIR HANDLER
MODEL WIDTH
14.5 SEER HP WITH AIR HANDLERS
AHE24B 17.5 585 18.0 13.3 14.50 12.00 AHE30B 17.5 660 18.0 13.1 15.00 12.50 AHR24B 17.5 675 18.0 13.1 13.00 11.00 AHV24B 17.5 580 18.0 13.4 14.50 12.50 AHV30B 17.5 700 18.0 14.6 14.50 12.50 AHV36C 21.0 670 18.0 14.5 15.00 12.50
AV*36 21.0 630 18.0 13.3 15.00 12.50 MV12B 17.5 FC/MC35B 600 18.0 13.0 15.00 12.50 MV12B 17.5 FC/MC43B 600 18.0 13.3 15.00 12.50 MX12B 17.5 FC/MC35B 660 18.0 13.8 15.00 12.50 MX12B 17.5 FC/MC43B 620 18.0 13.6 15.00 12.50
AHE24B 17.5 825 23.0 17.4 15.00 12.50 AHE30B 17.5 800 23.0 17.4 15.00 12.50 AHR24B 17.5 740 22.2 16.0 13.25 11.35 AHV24B 17.5 710 22.6 16.5 14.50 12.50 AHV30B 17.5 775 22.8 17.1 14.50 12.50 AHV36C 21.0 760 23.2 17.3 15.00 12.50
AV*36 21.0 725 22.8 16.8 15.00 12.50 MV12B 17.5 FC/MC35B 800 22.8 17.2 15.00 12.50 MV12B 17.5 FC/MC43B 800 23.4 18.0 15.00 12.50 MX12B 17.5 FC/MC35B 815 23.2 17.5 15.00 12.50 MX12B 17.5 FC/MC43B 735 23.0 16.9 15.00 12.50
AHE36C 21.0 1000 30.0 21.7 15.00 12.50 AHR36B 17.5 1060 28.8 22.0 13.25 11.35 AHV36C 21.0 895 28.6 26.2 15.00 12.50
AV*36 21.0 960 29.2 21.8 15.00 12.50 MV12B 17.5 FC/MC43B 1000 29.0 21.6 15.00 12.50 MV16C 21.0 FC/MC43C 1000 29.0 21.6 15.00 12.50 MX12B 17.5 FC/MC43B 1095 30.0 22.3 15.00 12.50 MX16C 21.0 FC/MC43C 970 30.0 21.5 15.00 12.50
AHE36C 21.0 1275 36.0 27.4 14.50 12.00 AHE42D 24.5 1275 36.0 26.4 15.00 12.50 AHE48D 24.5 1195 35.8 26.6 14.50 12.00 AHR36B 17.5 1245 35.4 26.2 13.00 11.00 AHR42C 21.0 1230 35.6 26.4 13.35 11.45 AHV36C 21.0 1215 36.0 27.6 14.00 12.00 AHV42D 24.5 1180 36.0 27.8 15.00 12.50 AHV48D 24.5 1155 36.0 27.2 15.00 12.50
AV*36 21.0 1190 35.6 26.2 14.50 12.00
AV*48 24.5 1220 36.0 27.4 14.50 12.00 MV12B 17.5 FC/MC43B 1225 35.6 26.2 14.00 12.00 MV12D 24.5 FC/MC48D 1160 36.0 26.6 15.00 12.50 MV12D 24.5 FC/MC60D 1135 36.0 26.2 14.50 12.00 MV16C 21.0 FC/MC43C 1200 35.8 26.2 14.50 12.00 MV16C 21.0 FC/MC48C 1200 36.0 26.4 14.50 12.00 MV16C 21.0 FC60C 1200 36.0 27.0 15.00 12.50 MX12B 17.5 FC/MC43B 1220 35.6 26.0 14.00 12.00 MX12D 24.5 FC/MC48D 1225 36.0 26.4 14.50 12.00 MX12D 24.5 FC/MC60D 1275 36.0 27.8 15.00 12.50 MX16C 21.0 FC/MC43C 1140 35.4 25.8 14.50 12.00 MX16C 21.0 FC/MC48C 1150 36.0 26.6 15.00 12.50 MX16C 21.0 FC60C 1150 36.0 26.8 15.00 12.50
COIL
MODEL
1
RATED
CFM
TOTAL SENS.
COOLING
NET MBH
SEER EER
4 Johnson Controls Unitary Products
561923-YTG-F-0114
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
MODEL WIDTH
COIL
MODEL
1
RATED
CFM
TOTAL SENS.
14.5 SEER HP WITH AIR HANDLERS
AHE48D 24.5 1125 39.5 27.0 15.00 12.50 AHE60D 24.5 1350 39.0 28.8 14.50 12.00 AHR48D 24.5 1320 39.5 28.4 13.25 11.35 AHV48D 24.5 1155 40.0 27.6 15.00 12.50
YHJF42S41S5
AHV60D 24.5 1340 39.0 28.6 14.00 12.00
MV16C 21.0 FC60C 1400 41.0 30.2 14.50 12.00 MV20D 24.5 FC/MC60D 1300 40.5 29.4 15.00 12.50 MV20D 24.5 FC/MC62D 1400 39.0 28.6 14.00 12.00 MX20D 24.5 FC/MC60D 1295 41.0 29.6 15.00 12.50
MX20D 24.5 FC/MC62D 1470 40.0 30.2 14.50 12.00 AHE48D 24.5 1295 45.5 30.8 14.00 12.00 AHE60D 24.5 1310 47.0 31.6 15.00 12.50 AHR48D 24.5 1320 44.5 30.2 13.25 11.35 AHV48D 24.5 1300 45.5 30.8 14.50 12.50 AHV60D 24.5 1340 47.0 31.8 15.00 12.50
MV16C 21.0 FC60C 1400 46.0 32.2 14.50 12.00
YHJF48S41S5
MV20D 24.5 FC/MC60D 1400 46.0 32.2 14.50 12.00
MV20D 24.5 FC/MC62D 1400 47.0 31.8 15.00 12.50
MV20D 24.5 FC64D 1400 48.0 33.6 15.00 12.50
MX16C 21.0 FC60C 1420 46.0 32.6 15.00 12.50
MX20D 24.5 FC/MC60D 1470 46.5 33.2 15.00 12.50
MX20D 24.5 FC/MC62D 1470 48.0 33.6 15.00 12.50
MX20D 24.5 FC64D 1470 48.0 34.6 15.00 12.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240. Cooling MBH based on 80 °F entering air temperature, 50% RH (Relative Humidity), and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total el ectric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. — = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
COOLING
NET MBH
SEER EER
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
MODEL WIDTH
COIL
MODEL
STAGE
1
RATED
CFM
TOTAL SENS.
14.5 SEER HP WITH AIR HANDLERS
AHE60D 24.5
AHV60D 24.5
MV20D 24.5 FC/MC62D
YHJF60S41S1
MV20D 24.5 FC64D
MX20D 24.5 FC/MC62D
MX20D 24.5 FC64D
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240. Cooling MBH based on 80 °F entering air temperature, 50% RH (Relative Humidity), and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total el ectric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. — = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
1 1160 46.0 29.8 2 1835 57.0 41.0 1 1090 46.5 30.8 2 1635 57.0 40.5 1 1160 48.0 31.0 2 1855 57.0 40.5 1 1160 50.0 32.6 2 1855 59.0 42.5 1 1390 48.0 32.4 2 1795 57.5 41.0 1 1390 49.5 33.8 2 1795 58.0 42.0
Johnson Controls Unitary Products 5
COOLING
NET MBH
SEER EER
15.00 12.20
15.00 11.75
15.00 12.00
15.00 12.50
15.00 12.50
15.00 12.50
561923-YTG-F-0114
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
COIL
MODEL WIDTH
CFM RANGE
(Min.-max.)
STAGE
RATED
14.5 SEER HP COIL ONLY RATINGS
FC/MC/PC32 14.5 450 - 750 600 18.0 12.6 13.25 11.35
YHJF18S41S1
FC/MC/PC35 17.5,21.0 450 - 750 600 18.0 12.6 13.20 11.35 FC/MC/PC37 14.5 450 - 750 600 18.0 13.2 13.25 11.35 FC/MC/PC43 17.5,21.0 450 - 750 600 18.0 13.2 13.25 11.35 FC/MC/PC32 14.5 600 - 1000 800 22.2 16.3 13.25 11.35
YHJF24S41S1
FC/MC/PC35 17.5,21.0 600 - 1000 800 22.4 16.3 13.20 11.35 FC/MC/PC37 14.5 600 - 1000 800 22.4 16.6 13.25 11.35 FC/MC/PC43 17.5,21.0 600 - 1000 800 22.4 16.6 13.25 11.35
YHJF30S41S1
FC/MC/PC37 14.5 800 - 1200 1000 28.6 21.6 13.25 11.35 FC/MC/PC43 17.5,21.0 800 - 1200 1000 28.4 21.6 13.50 11.35 FC/MC/PC37 14.5 1000 - 1400 1200 35.0 25.6 13.00 11.00 FC/MC/PC43 17.5,21.0 1000 - 1400 1200 35.0 25.8 13.00 11.00
YHJF36S41S4
FC/MC/PC48 21.0,24.5 1000 - 1400 1200 35.2 25.8 13.35 11.45 FC/MC/PC60 21.0,24.5 1000 - 1400 1200 35.6 26.0 13.35 11.45
UC48 21.0,24.5 1000 - 1400 1200 35.0 26.0 13.25 11.35 UC60 21.0,24.5 1000 - 1400 1200 35.0 25.6 13.25 11.35
YHJF42S41S5
FC/MC/PC60 21.0,24.5 1200 - 1600 1200 39.0 27.0 13.25 11.35
FC/MC62 24.5 1200 - 1600 1400 38.0 27.8 13.00 11.00
FC/MC/PC60 21.0, 24.5 1400 - 1800 1400 45.5 31.6 13.25 11.35
YHJF48S41S5
FC/MC62 24.5 1400 - 1800 1600 48.0 34.2 14.00 12.00
FC64 24.5 1400 - 1800 1400 48.0 32.0 14.00 12.00
YHJF60S41S1
1. Requires a S1-2FD06700224 Blower Time Delay unless a standar d furnace is equipped with one. MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS ,TG9S, use Coil Only Ratings.
FC/MC62 24.5 1150 - 1550 1 1350 48.0 31.8 13.30 11.35 FC/MC62 24.5 1600 - 2000 2 1800 56.5 39.5 13.30 11.35
CFM
TOTAL SENS.
COOLING
NET MBH
SEER
1
EER
COOLING CAP ACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
YHJF18S41S1
YHJF24S41S1
For notes, see Page 9.
MODEL WIDTH
T*(8,L)V*A12 14.5 FC/MC/PC32A 590 18.0 13.0 15.00 12.50 T*(8,L)V*A12 14.5 FC/MC/PC37A 625 18.0 13.3 15.00 12.50 T*(8,L)V*B12 17.5 FC/MC/PC35B 650 18.0 13.4 15.00 12.50 T*(8,L)V*B12 17.5 FC/MC/PC43B 560 18.0 12.8 15.00 12.50
T*(8,L)V*C16 21.0 FC/MC/PC35C 600 18.0 13.0 15.00 12.50 T*9(C,V)*B12 17.5 FC/MC/PC35B 570 18.0 13.0 15.00 12.50 T*9(C,V)*C16 21.0 FC/MC/PC35C 645 18.0 13.4 15.00 12.50
T*9V*A10 14.5 FC/MC/PC32A 580 17.5 13.3 14.00 11.95
T*9V*A10 14.5 FC/MC/PC37A 570 17.5 13.2 14.00 11.95 Y*(8,L)C*A12 14.5 FC/MC/PC32A 590 18.0 13.0 15.00 12.50 Y*(8,L)C*A12 14.5 FC/MC/PC37A 625 18.0 13.3 15.00 12.50 Y*(8,L)C*B12 17.5 FC/MC/PC35B 650 18.0 13.4 15.00 12.50 Y*(8,L)C*B12 17.5 FC/MC/PC43B 560 18.0 12.8 15.00 12.50 Y*(8,L)C*C16 21.0 FC/MC/PC35C 600 18.0 13.0 15.00 12.50
Y*9C*B12 17.5 FC/MC/PC35B 570 18.0 13.0 15.00 12.50
Y*9C*C16 21.0 FC/MC/PC35C 645 18.0 13.4 15.00 12.50 T*(8,L)V*A12 14.5 FC/MC/PC32A 775 22.8 17.1 14.50 12.00 T*(8,L)V*A12 14.5 FC/MC/PC37A 805 23.2 17.9 15.00 12.50 T*(8,L)V*B12 17.5 FC/MC/PC35B 760 22.6 16.7 15.00 12.50 T*(8,L)V*B12 17.5 FC/MC/PC43B 760 22.8 17.0 15.00 12.50
FURNACE
COIL
MODEL
14.5 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
1
RATED
CFM
TOTAL SENS.
COOLING
NET MBH
2
SEER EER
6 Johnson Controls Unitary Products
COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
YHJF24S41S1
YHJF30S41S1
YHJF36S41S4
For notes, see Page 9.
FURNACE
MODEL WIDTH
14.5 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
T*(8,L)V*C16 21.0 FC/MC/PC35C 85 5 23.0 17.7 15.00 12.50 T*(8,L)V*C16 21.0 FC/MC/PC43C 87 5 23.4 18.5 15.00 12.50 T*(8,L)V*C20 21.0 FC/MC/PC35C 74 0 22.6 16.6 15.00 12.50 T*(8,L)V*C20 21.0 FC/MC/PC43C 76 0 23.0 17.1 15.00 12.50 T*9(C,V)*B12 17.5 FC/MC/PC35B 815 22.8 17.1 14.50 12.00 T*9(C,V)*B12 17.5 FC/MC/PC43B 800 23.2 17.9 15.00 12.50 T*9(C,V)*C16 21.0 FC/MC/PC35C 865 23.2 18.2 15.00 12.50 T*9(C,V)*C16 21.0 FC/MC/PC43C 810 23.4 18.0 15.00 12.50 T*9(C,V)*C20 21.0 FC/MC/PC35C 755 22.6 16.7 15.00 12.50 T*9(C,V)*C20 21.0 FC/MC/PC43C 875 23.4 18.4 15.00 12.50
T*9V*A10 14.5 FC/MC/PC32A 785 22.2 16.5 13.60 11.70
T*9V*A10 14.5 FC/MC/PC37A 790 22.4 16.8 13.65 11.75 Y*(8,L)C*A12 14.5 FC/MC/PC32A 775 22.8 17.1 14.50 12.00 Y*(8,L)C*A12 14.5 FC/MC/PC37A 805 23.2 17.9 15.00 12.50 Y*(8,L)C*B12 17.5 FC/MC/PC35B 760 22.6 16.7 15.00 12.50 Y*(8,L)C*B12 17.5 FC/MC/PC43B 760 22.8 17.0 15.00 12.50 Y*(8,L)C*C16 21.0 FC/MC/PC35C 855 23.0 17.7 15.00 12.50 Y*(8,L)C*C16 21.0 FC/MC/PC43C 875 23.4 18.5 15.00 12.50 Y*(8,L)C*C20 21.0 FC/MC/PC35C 740 22.6 16.6 15.00 12.50 Y*(8,L)C*C20 21.0 FC/MC/PC43C 760 23.0 17.1 15.00 12.50
Y*9C*B12 17.5 FC/MC/PC35B 815 22.8 17.1 14.50 12.00 Y*9C*B12 17.5 FC/MC/PC43B 800 23.2 17.9 15.00 12.50 Y*9C*C16 21.0 FC/MC/PC35C 865 23.2 18.2 15.00 12.50 Y*9C*C16 21.0 FC/MC/PC43C 810 23.4 18.0 15.00 12.50 Y*9C*C20 21.0 FC/MC/PC35C 755 22.6 16.7 15.00 12.50
Y*9C*C20 21.0 FC/MC/PC43C 875 23.4 18.4 15.00 12.50 T*(8,L)V*A12 14.5 FC/MC/PC37A 980 28.6 21.4 14.50 12.00 T*(8,L)V*B12 17.5 FC/MC/PC43B 990 28.8 21.4 15.00 12.50 T*(8,L)V*C16 21.0 FC/MC/PC43C 99 0 29.0 21.6 15.00 12.50 T*(8,L)V*C20 21.0 FC/MC/PC43C 1000 29.0 21.6 15.00 12.50 T*9(C,V)*B12 17.5 FC/MC/PC43B 1035 29.0 22.0 14.50 12.00
T*9(C,V)*C16 21.0 FC/MC/PC43C 1030 29.2 22.2 15.00 12.50 T*9(C,V)*C20 21.0 FC/MC/PC43C 995 29.0 21.6 15.00 12.50 Y*(8,L)C*A12 14.5 FC/MC/PC37A 980 28.6 21.4 14.50 12.00 Y*(8,L)C*B12 17.5 FC/MC/PC43B 990 28.8 21.4 15.00 12.50 Y*(8,L)C*C16 21.0 FC/MC/PC43C 990 29.0 21.6 15.00 12.50 Y*(8,L)C*C20 21.0 FC/MC/PC43C 1000 29.0 21.6 15.00 12.50
Y*9C*B12 17.5 FC/MC/PC43B 1035 29.0 22.0 14.50 12.00
Y*9C*C16 21.0 FC/MC/PC43C 1030 29.2 22.2 15.00 12.50
Y*9C*C20 21.0 FC/MC/PC43C 995 29.0 21.6 15.00 12.50 T*(8,L)V*B12 17.5 FC/MC/PC43B 1275 35.6 26.6 13.25 11.50
T*(8,L)V*C16 21.0 FC/MC/PC43C 1190 35.6 26.2 14.00 12.00 T*(8,L)V*C16 21.0 FC/MC/PC48C 1195 36.0 26.4 14.50 12.00 T*(8,L)V*C16 21.0 FC/PC60C 1185 36.0 26.8 14.50 12.00 T*(8,L)V*C16 21.0 UC48C 1210 36.0 26.6 15.00 12.50 T*(8,L)V*C16 21.0 UC60C 1195 36.0 26.2 15.00 12.50 T*(8,L)V*C20 21.0 FC/MC/PC43C 1190 35.6 26.2 14.00 12.00 T*(8,L)V*C20 21.0 FC/MC/PC48C 1150 36.0 26.4 14.50 12.00 T*(8,L)V*C20 21.0 FC/PC60C 1215 36.0 26.8 14.50 12.00 T*(8,L)V*C20 21.0 UC48C 1155 36.0 26.6 15.00 12.50 T*(8,L)V*C20 21.0 UC60C 1215 36.0 26.2 15.00 12.50 T*9(C,V)*B12 17.5 FC/MC/PC43B 1200 35.2 25.8 13.50 11.50
COIL
MODEL
1
RATED
CFM
COOLING
NET MBH
TOTAL SENS.
2
561923-YTG-F-0114
SEER EER
Johnson Controls Unitary Products 7
561923-YTG-F-0114
COOLING CAP ACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
YHJF36S41S4
YHJF42S41S5
For notes, see Page 9.
FURNACE
MODEL WIDTH
14.5 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
T*9(C,V)*C16 21.0 FC/MC/PC43C 1240 35.4 26.0 13.75 11.75 T*9(C,V)*C16 21.0 FC/MC/PC48C 1195 35.8 26.4 14.00 12.00 T*9(C,V)*C16 21.0 FC/PC60C 1235 36.0 26.6 14.00 12.00 T*9(C,V)*C16 21.0 UC48C 1195 36.0 26.4 14.50 12.00 T*9(C,V)*C16 21.0 UC60C 1235 36.0 26.0 14.00 12.00 T*9(C,V)*C20 21.0 FC/MC/PC43C 1200 35.6 26.2 14.00 12.00 T*9(C,V)*C20 21.0 FC/MC/PC48C 1330 36.0 27.8 14.00 12.00 T*9(C,V)*C20 21.0 FC/PC60C 1330 36.0 28.0 14.00 12.00 T*9(C,V)*C20 21.0 UC48C 1330 36.0 28.0 14.50 12.00 T*9(C,V)*C20 21.0 UC60C 1330 36.0 27.6 14.50 12.00 T*9(C,V)*D20 24.5 FC/MC/PC48D 1240 35.8 26.4 14.00 12.00 T*9(C,V)*D20 24.5 FC/MC/PC60D 1225 36.0 26.6 14.00 12.00 T*9(C,V)*D20 24.5 UC48D 1240 36.0 26.6 15.00 12.50 T*9(C,V)*D20 24.5 UC60D 1225 36.0 26.2 14.50 12.00 Y*(8,L)C*A12 14.5 FC/MC/PC37A 1150 35.2 25.8 13.50 11.50 Y*(8,L)C*B12 14.5 FC/MC/PC43B 1275 35.6 26.6 13.25 11.50 Y*(8,L)C*C16 21.0 FC/MC/PC43C 1190 35.6 26.2 14.00 12.00 Y*(8,L)C*C16 21.0 FC/MC/PC48C 1195 36.0 26.4 14.50 12.00 Y*(8,L)C*C16 21.0 FC/PC60C 1185 36.0 26.8 14.50 12.00 Y*(8,L)C*C16 21.0 UC48C 1210 36.0 26.6 15.00 12.50 Y*(8,L)C*C16 21.0 UC60C 1195 36.0 26.2 15.00 12.50 Y*(8,L)C*C20 21.0 FC/MC/PC43C 1190 35.6 26.2 14.00 12.00 Y*(8,L)C*C20 21.0 FC/MC/PC48C 1150 36.0 26.4 14.50 12.00 Y*(8,L)C*C20 21.0 FC/PC60C 1215 36.0 26.8 14.50 12.00 Y*(8,L)C*C20 21.0 UC48C 1155 36.0 26.6 15.00 12.50 Y*(8,L)C*C20 21.0 UC60C 1215 36.0 26.2 15.00 12.50
Y*9C*B12 17.5 FC/MC/PC43B 1200 35.2 25.8 13.50 11.50 Y*9C*C16 21.0 FC/MC/PC43C 1240 35.4 26.0 13.75 11.75 Y*9C*C16 21.0 FC/MC/PC48C 1195 35.8 26.4 14.00 12.00 Y*9C*C16 21.0 FC/PC60C 1235 36.0 26.6 14.00 12.00 Y*9C*C16 21.0 UC48C 1195 36.0 26.4 14.50 12.00 Y*9C*C16 21.0 UC60C 1235 36.0 26.0 14.00 12.00 Y*9C*C20 21.0 FC/MC/PC43C 1200 35.6 26.2 14.00 12.00 Y*9C*C20 21.0 FC/MC/PC48C 1330 36.0 27.8 14.00 12.00 Y*9C*C20 21.0 FC/PC60C 1330 36.0 28.0 14.00 12.00 Y*9C*C20 21.0 UC48C 1330 36.0 28.0 14.50 12.00 Y*9C*C20 21.0 UC60C 1330 36.0 27.6 14.50 12.00 Y*9C*D20 24.5 FC/MC/PC48D 1240 35.8 26.4 14.00 12.00 Y*9C*D20 24.5 FC/MC/PC60D 1225 36.0 26.6 14.00 12.00 Y*9C*D20 24.5 UC48D 1240 36.0 26.6 15.00 12.50 Y*9C*D20 24.5 UC60D 1225 36.0 26.2 14.50 12.00
T*(8,L)V*C16 21.0 FC/MC62D 1420 39.0 28.8 14.00 11.50 T*(8,L)V*C16 21.0 FC/PC60C 1185 39.5 27.6 15.00 12.50 T*(8,L)V*C16 21.0 UC60C 1395 37.4 28.6 13.50 11.35 T*(8,L)V*C20 21.0 FC/MC62D 1365 38.5 28.2 14.00 11.50 T*(8,L)V*C20 21.0 FC/PC60C 1215 40.0 28.4 15.00 12.50 T*(8,L)V*C20 21.0 UC60C 1410 37.6 28.6 13.50 11.35 T*9(C,V)*C16 21.0 FC/MC62D 1445 39.0 28.8 13.50 11.35 T*9(C,V)*C16 21.0 FC/PC60C 1235 39.5 28.2 14.50 12.00 T*9(C,V)*C16 21.0 UC60C 1395 37.4 28.4 13.00 11.00 T*9(C,V)*C20 21.0 FC/MC62D 1445 39.0 29.0 13.50 11.35 T*9(C,V)*C20 21.0 FC/PC60C 1330 40.0 29.4 14.50 12.00
COIL
MODEL
1
RATED
CFM
COOLING
NET MBH
TOTAL SENS.
2
SEER EER
8 Johnson Controls Unitary Products
COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
MODEL WIDTH
FURNACE
14.5 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
T*9(C,V)*C20 21.0 UC60C 1405 37.6 28.6 13.05 11.05 T*9(C,V)*D20 24.5 FC/MC/PC60D 1225 40.0 28.4 14.50 12.00 T*9(C,V)*D20 24.5 FC/MC62D 1455 39.5 29.2 14.00 11.50 T*9(C,V)*D20 24.5 UC60D 1405 37.6 28.8 13.30 11.40 Y*(8,L)C*C16 21.0 FC/MC62D 1420 39.0 28.8 14.00 11.50 Y*(8,L)C*C16 21.0 FC/PC60C 1185 39.5 27.6 15.00 12.50 Y*(8,L)C*C16 21.0 UC60C 1395 37.4 28.6 13.50 11.40 Y*(8,L)C*C20 21.0 FC/MC62D 1365 38.5 28.2 14.00 11.50 Y*(8,L)C*C20 21.0 FC/PC60C 1215 40.0 28.4 15.00 12.50
YHJF42S41S5
Y*(8,L)C*C20 21.0 UC60C 1410 37.6 28.6 13.50 11.40
Y*9C*C16 21.0 FC/MC62D 1445 39.0 28.8 13.50 11.35 Y*9C*C16 21.0 FC/PC60C 1235 39.5 28.2 14.50 12.00 Y*9C*C16 21.0 UC60C 1395 37.4 28.4 13.05 11.05 Y*9C*C20 21.0 FC/MC62D 1445 39.0 29.0 11.50 11.35 Y*9C*C20 21.0 FC/PC60C 1330 40.0 29.4 14.50 12.00 Y*9C*C20 21.0 UC60C 1405 37.6 28.6 13.30 11.40 Y*9C*D20 24.5 FC/MC/PC60D 1225 40.0 28.4 14.50 12.00 Y*9C*D20 24.5 FC/MC62D 1455 39.5 29.2 14.00 11.35
Y*9C*D20 24.5 UC60D 1405 37.6 28.8 13.30 11.40 T*(8,L)V*C16 21.0 F C/MC62D 1420 48.0 33.0 14.50 12.00 T*(8,L)V*C16 21.0 FC/PC60C 1420 46.0 32.2 14.00 12.00 T*(8,L)V*C16 21.0 FC64D 1420 48.0 33.8 15.00 12.50 T*(8,L)V*C20 21.0 F C/MC62D 1365 47.0 32.2 15.00 12.50 T*(8,L)V*C20 21.0 FC/PC60C 1340 45.0 30.8 14.00 12.00 T*(8,L)V*C20 21.0 FC64D 1410 48.0 33.6 15.00 12.50
T*9(C,V)*C16 21.0 FC/MC62D 1445 47.0 32.8 14.50 12.00 T*9(C,V)*C16 21.0 FC/PC60C 1445 46.0 32.4 14.00 12.00 T*9(C,V)*C16 21.0 FC64D 1445 48.0 33.6 15.00 12.50 T*9(C,V)*C20 21.0 FC/MC62D 1445 47.5 33.0 14.50 12.00 T*9(C,V)*C20 21.0 FC/PC60C 1445 46.0 32.6 14.00 12.00 T*9(C,V)*C20 21.0 FC64D 1445 48.0 33.8 15.00 12.50 T*9(C,V)*D20 24.5 FC/MC/PC60D 1445 46.5 32.6 14.00 12.00 T*9(C,V)*D20 24.5 FC/MC62D 1455 47.5 33.4 15.00 12.50
YHJF48S41S5
T*9(C,V)*D20 24.5 FC64D 1455 48.0 34.0 15.00 12.50 Y*(8,L)C*C16 21.0 FC/MC62D 1420 48.0 33.0 14.50 12.00 Y*(8,L)C*C16 21.0 FC/PC60C 1420 46.0 32.2 14.00 12.00 Y*(8,L)C*C16 21.0 FC64D 1420 48.0 33.8 15.00 12.50 Y*(8,L)C*C20 21.0 FC/MC62D 1365 47.0 32.2 15.00 12.50 Y*(8,L)C*C20 21.0 FC/PC60C 1340 45.0 30.8 14.00 12.00 Y*(8,L)C*C20 21.0 FC64D 1410 48.0 33.6 15.00 12.50
Y*9C*C16 21.0 FC/MC62D 1445 47.0 32.8 14.50 12.00
Y*9C*C16 21.0 FC/PC60C 1445 46.0 32.4 14.00 12.00
Y*9C*C16 21.0 FC64D 1445 48.0 33.6 15.00 12.50
Y*9C*C20 21.0 FC/MC62D 1445 47.5 33.0 14.50 12.00
Y*9C*C20 21.0 FC/PC60C 1445 46.0 32.6 14.00 12.00
Y*9C*C20 21.0 FC64D 1445 48.0 33.8 15.00 12.50
Y*9C*D20 24.5 FC/MC/PC60D 1445 46.5 32.6 14.00 12.00
Y*9C*D20 24.5 FC/MC62D 1455 47.5 33.4 15.00 12.50
Y*9C*D20 24.5 FC64D 1455 48.0 34.0 15.00 12.50
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard. PSC furnaces, such as the TG8S, TGLS ,TG9S, use Coil Only Ratings.
COIL
MODEL
1
RATED
CFM
COOLING
NET MBH
TOTAL SENS.
2
561923-YTG-F-0114
SEER EER
Johnson Controls Unitary Products 9
561923-YTG-F-0114
COOLING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
FURNACE
MODEL WIDTH
14.5 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
T*(8,L)V*C20 21.0 FC/MC62D
T*(8,L)V*C20 21.0 FC64D
T*9(C,V)*C20 21.0 FC/MC62D
T*9(C,V)*C20 21.0 FC64D
T*9(C,V)*D20 24.5 FC/MC62D
T*9(C,V)*D20 24.5 FC64D
YHJF60S41S1
Y*(8,L)C*C20 21.0 FC/MC62D
Y*(8,L)C*C20 21.0 FC64D
Y*9C*C20 21.0 FC/MC62D
Y*9C*C20 21.0 FC64D
Y*9C*D20 24.5 FC/MC62D
Y*9C*D20 24.5 FC64D
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard. PSC furnaces, such as the TG8S, TGLS ,TG9S, use Coil Only Ratings.
COIL
MODEL
1
STAGE
1 1015 46.0 29.2 2 1615 56.5 38.5 1 1015 48.5 30.6 2 1615 58.0 40.0 1 1040 46.5 29.4 2 1655 56.0 38.5 1 1040 49.0 30.8 2 1655 57.5 40.0 1 1085 47.0 29.8 2 1630 56.0 38.5 1 1085 49.0 31.4 2 1630 57.5 40.0 1 1015 46.0 29.2 2 1615 56.5 38.5 1 1015 48.5 30.6 2 1615 58.0 40.0 1 1040 46.5 29.4 2 1655 56.0 38.5 1 1040 49.0 30.8 2 1655 57.5 40.0 1 1085 47.0 29.8 2 1630 56.0 38.5 1 1085 49.0 31.4 2 1630 57.5 40.0
RATED
CFM
COOLING
NET MBH
TOTAL SENS.
2
SEER EER
14.50 12.00
15.00 12.50
14.50 12.00
15.00 12.25
14.50 12.00
15.00 12.50
14.50 12.00
15.00 12.50
14.50 12.00
15.00 12.25
14.50 12.00
15.00 12.50
HEATING CAPACITY - With Air Handler Coils
UNIT
MODEL*
YHJF18S41S1
YHJF24S41S1
For notes, see Page 12.
AIR
HANDLER
14.5 SEER HP WITH AIR HANDLERS
AHE24B 18.03.821.3811.02.501.298.20 AHE30B 18.03.881.3610.92.541.268.50 AHR24B 18.0 3.56 1.52 11.4 2.34 1.43 7.75 AHV24B 18.03.761.4010.92.501.288.50 AHV30B 18.03.921.3511.02.541.278.50 AHV36C 18.0 4.00 1.32 11.0 2.60 1.24 8.50
AV*36 18.03.981.3310.82.621.218.50 MV12B FC/MC35B 18.0 3.76 1.40 11.0 2.48 1.30 8.50 MV12B FC/MC43B 18.03.901.3510.92.561.258.50 MX12B FC/MC35B 18.03.961.3310.92.561.258.50 MX12B FC/MC43B 18.03.961.3310.92.601.238.50
AHE24B 22.23.681.7713.72.441.658.50 AHE30B 22.23.681.7713.72.441.658.50 AHR24B 22.43.421.9213.92.301.777.75 AHV24B 22.23.581.8213.72.401.678.50 AHV30B 22.23.641.7913.72.421.668.50 AHV36C 22.23.761.7313.62.501.598.50
AV*36 22.03.701.7414.82.501.738.50
COIL
MODEL
1
HEATING
2
47F17FHSPF
MBH COP KW MBH COP KW STD
10 Johnson Controls Unitary Products
HEATING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL*
YHJF24S41S1
YHJF30S41S1
YHJF36S41S4
YHJF42S41S5
For notes, see Page 12.
AIR
HANDLER
14.5 SEER HP WITH AIR HANDLERS
MV12B FC/MC35B 22.2 3.68 1.77 14.9 2.46 1.77 8.50 MV12B FC/MC43B 22.2 3.82 1.70 14.9 2.54 1.72 8.50 MX12B FC/MC35B 22.0 3.72 1.73 13.6 2.46 1.62 8.50
MX12B FC/MC43B 22.0 3.70 1.74 13.5 2.48 1.59 8.50 AHE36C 30.04.082.1520.42.622.289.00 AHR36B 30.03.762.4219.42.502.277.75 AHV36C 30.03.762.3418.82.402.309.00
AV*36 29.83.982.1918.62.741.999.00 MV12B FC/MC43B 30.0 3.88 2.27 18.8 2.68 2.06 9.00 MV16C FC/MC43C 30.0 3.92 2.24 18.8 2.70 2.04 9.00 MX12B FC/MC43B 30.0 4.10 2.14 20.6 2.60 2.32 9.00 MX16C FC/MC43C 30.0 4.04 2.18 20.4 2.60 2.30 9.00
AHE36C 34.6 3.80 2.67 20.2 2.80 2.11 8.50 AHE42D 34.6 3.80 2.67 20.2 2.80 2.11 9.00 AHE48D 33.83.742.6519.82.782.098.50 AHR36B 35.03.522.9120.82.582.368.20 AHR42C 34.83.562.8620.82.622.338.20 AHV36C 34.83.762.7120.62.742.208.20 AHV42D 34.4 3.80 2.65 20.2 2.80 2.11 9.00 AHV48D 34.23.802.6420.02.802.099.00
AV*36 34.23.722.6920.02.762.128.50
AV*48 34.83.902.6120.42.862.098.50 MV12B FC/MC43B 34.6 3.68 2.75 20.2 2.72 2.18 8.50 MV12D FC/MC48D 33.8 3.78 2.62 19.9 2.82 2.07 9.00 MV12D FC/MC60D 34.6 3.82 2.65 20.4 2.82 2.12 8.50 MV16C FC/MC43C 34.4 3.72 2.71 20.0 2.74 2.14 8.50 MV16C FC/MC48C 34.0 3.72 2.68 20.0 2.76 2.12 8.50 MV16C FC60C 35.4 3.96 2.62 20.8 2.86 2.13 9.00 MX12B FC/MC43B 34.6 3.66 2.77 20.2 2.70 2.19 8.50 MX12D FC/MC48D 34.0 3.72 2.68 20.0 2.76 2.12 8.50 MX12D FC/MC60D 35.0 3.92 2.62 20.6 2.86 2.11 9.00 MX16C FC/MC43C 33.8 3.72 2.66 19.6 2.76 2.08 8.50 MX16C FC/MC48C 33.8 3.78 2.62 19.8 2.82 2.06 9.00 MX16C FC60C 35.0 3.98 2.58 20.6 2.90 2.08 9.00
AHE48D 39.53.703.1325.42.662.809.00 AHE60D 39.03.783.0225.42.682.788.50 AHR48D 40.53.523.3726.42.503.098.50 AHV48D 39.53.743.0925.22.682.769.00 AHV60D 39.03.743.0625.62.642.848.50
MV16C FC60C 40.5 3.88 3.06 25.8 2.70 2.80 8.50 MV20D FC/MC60D 40.0 3.92 2.99 25.4 2.74 2.72 9.00 MV20D FC/MC62D 39.0 3.74 3.06 25.4 2.64 2.82 8.50 MX20D FC/MC60D 40.0 3.98 2.94 25.2 2.78 2.66 9.00 MX20D FC/MC62D 39.0 3.90 2.93 25.4 2.72 2.74 8.50
COIL
MODEL
1
561923-YTG-F-0114
HEATING
47F17F HSPF
MBH COP KW MBH COP KW STD
2
Johnson Controls Unitary Products 11
Loading...