LX SERIES
SPLIT-SYSTEM AIR CONDITIONERS
13 SEER – R-410A – 1 PHASE
(1.5 THRU 5 NOMINAL TONS)
MODELS: YCJD18 THRU 60
Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at
www.upgnet.com and www.york.com
Additional rating information can be found at:
www.ahridirectory.org
WARRANTY SUMMARY*
Standard 5-Years limited parts warranty.
Standard 10-Years limited compressor warranty.
Extended 10-Years limited parts warranty when product is
registered online within 90 days of purchase for replacement
or closing for new home construction.
*Does not apply to R-22 models, 3-Phase models, or internet sales.
See Limited Warranty certificate in User's Information Manual for details.
®
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
840569-YTG-A-0612
DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with accessories and documents to serve specific functions.
FEATURES
• Small Footprint - Extremely lightweight with a compact foot-
print, it is a perfect fit for any application.
• Quality Condenser Coils - The coil is constructed of aluminum microchannel tubing and enhanced aluminum fins for
reduced size and increased efficiency.
• Coil Protection - Coils are protected from damage by a slotted, stamped steel coil guard and secondary polymer mesh.
®
• Optional Factory E-Coat - Available ElectroFin
on select models.
• Protected Compressor - Compressors are protected internally by a high pressure relief valve and a temperature sensor, and externally by the system high pressure switch. A
factory installed liquid line filter-drier further protects the
compressor against moisture and debris.
• Environmentally Friendly Refrigerant - The next genera-
tion refrigerant R-410A delivers environmentally friendly performance with zero ozone depletion.
• Durable Finish - The cabinet is made of G90-equivalent prepainted steel, with special primer formulas and matte champagne texture to insure less fading when exposed to sunlight. The coated steel wire fan guard and pre-treated,
galvanized steel chassis components resist corrosion and
rust creep.
• Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections. The
unit is factory charged for a 15-foot lineset. The small base
dimension means less space is required on the ground or
roof.
• To p Discharge - W arm air from the top mounted fan is blown
up, away fro0m the structure and any landscaping. This
allows compact location on multi-unit applications.
• Low Operating Sound Levels - The upward air flow carries
the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the condenser coil muffle the normal fan motor and compressor operating sounds.
• Low Maintenance - Long life, permanently lubricated motorbearings need no annual servicing.
• Easy Service Access - Fully exposed refrigerant connec-
tions and a single panel covering the electrical controls make
for easy servicing of the unit.
• Secured Service Valves - Secured, re-usable service
valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.
• Agency Listed - Safety certified by CSA to UL 1995 / CSA
22.2. Performance certified to ANSI/AHRI Standard 210/240
in accordance with the Unitary Small Equipment certification
program.
coated coil
840569-YTG-A-0612
B
C
A
Physical and Electrical Data
MODEL
YCJD18
S41S1(H)(E)
Unit Supply Voltage208-230V, 1 60Hz
Normal Voltage Range
Models with "H" on the end of the model number are shipped with a Hard Start Kit installed at the factory.
Models with “E” on the end of the model number have an ElectroFin® coating on the outdoor coil.
1. Rated in accordance with AHRI Standa rd 110-2012, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or
subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
YCJD24
S41S1(H)(E)
YCJD30
S41S1(H)(E)
YCJD36
S41S1(H)(E)
187 to 252
YCJD42
S41S2(H)(E)
YCJD48
S41S1(H)(E)
YCJD60
S41S1(E)
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
FC/MC/PC43–4200––
FC/MC/PC48–––8104–
FC/MC/PC60––––900
FC/MC62 ––––14–4
FC64––––23–11
UC180––––––
UC36–0–––––
UC48–––844–
UC60––––900
Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the “COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils” table.
FOOTNOTES:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. Approved orifice(s) shipped with outdoor unit.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizo ntal applications.
5. Refer to Cooling Performance Data tables for actual system performance for specified system matches.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for matched indoor unit +
charge adder for line set.
Models 12-48 require Hard Start Kits for TXV matches. Models with “H” on the end of the model number have factory installed Hard Start Kits.
For models without an “H” refer to the Hard Start Kit Accessory Installation Manual for the Hard Start Kit part number for each model.
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flo w.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
COOLING
NET MBH
SEEREER
Johnson Controls Unitary Products7
840569-YTG-A-0612
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
TOTALSENS.
COOLING
NET MBH
SEER
1
EER
8Johnson Controls Unitary Products
COOLING CAPACITY - With High Efficiency Motor Furnaces