TECHNICAL GUIDE
HORIZONTAL DISCHARGE
AIR CONDITIONERS
13 SEER – R-410A
MODELS:
TCHD18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
Standard 510-year limited compressor warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replacement or closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
556454-YTG-A-0210
DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be custommatched with one of UPG’s complete line of evaporator sections, with each serving a specific function. Matching Air Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters are
available, if required. Add-On coils are available for use with
upflow, downflow, or horizontal furnaces and air handlers.
FEATURES
• Performance - Efficiency levels from 13.0 SEER/11.5 EER
with a loose coil and up to 15.5 SEER/13.5 EER when coupled with a variable speed indoor blower.
• Easy to Install - Compact “slim-line” design allows for easy
installation in tight spaces. Units can be stacked.
• Lower Installation Cost - Installation time and costs are
reduced by easy power and control wiring connections. The
unit contains enough refrigerant for matching indoor coils
and 15 feet of interconnecting piping.
• Quiet Operation - Levels as low as 67 dBA. High efficiency
scroll compressor and swept wing fan design reducing operating sound to a mere whisper.
• State Of The Art Coil Technology - Micro-channel (MC2)
aluminum coil technology provides enhanced capacities and
efficiencies plus the benefit of maximum corrosion protection
especially in coastal applications (up to 7 times greater corrosion resistance than conventional copper tube and aluminum fin coils).
• Compressor Protection - The compressor is internally protected against high pressure and temperature. This is
accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the
compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor.
• Durable Cabinet - Heavy-gage steel cabinet and a tubular
base rail provide added support.
• Durable Finish - Automotive quality finish provides the ultimate protection from harmful U.V. rays and rust creep ensuring long-lasting high quality appearance. A powder-paint
topcoat is applied over a baked-on primer, using a galvanized, zinc coated steel base material. The result is a finish
that has been proven in testing to provide 33% greater durability than conventional powder-coat finishes.
• Aesthetic - Powder paint “Champagne” Color provides an
attractive retail finish.
• Low Maintenance - Long life permanently lubricated motorbearings need no annual servicing.
• Easy Service Access - Fully exposed refrigerant connections and a single panel covering the electrical controls make
for easy servicing of the unit.
• Secured Service Valve - Secured re-usable service valves
are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
• Other Features:
- Factory supplied filter drier
- High pressure switch, low pressure switch
- Accumulator and crankcase heater in all sizes
- Up to 200’ line set out of the box
- Zero lot line clearances (6” clearance in either direction)
• Agency Listed door application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.
U.L. and C.U.L. listed - approved for out-
556454-YTG-A-0210
Physical and Electrical Data
MODEL
TCHD18
S41S3
TCHD24
S41S3
TCHD30
S41S3
TCHD36
S41S3
TCHD48
S41S3
TCHD60
S41S3
Unit Supply Voltage 208-230V, 1 60Hz
Normal Voltage Range
1
187 to 252
Minimum Circuit Ampacity 11.8 17.4 17.5 23.1 27.1 34.3
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
2
3
20 30 30 40 45 60
15 20 20 25 30 35
Multi-Stage Compressor No No No No No No
Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll
Compressor Amps
Rated Load 9.0 13.5 12.8 17.3 20.5 26.3
Locked Rotor 48.0 58.3 64.0 96.7 115.0 134.0
Crankcase Heater Yes Yes Yes Yes Yes Yes
Fan Diameter Inches 17.5 17.5 23 23 23 23
Rated HP 1/8 1/8 1/4 1/4 1/4 1/4
Fan Motor
Rated Load Amps 0.60 0.60 1.45 1.45 1.45 1.45
Nominal RPM 840 840 850 850 850 850
Face Area Sq. Ft. 5.76 5.76 11.96 11.96 13.96 13.96
Coil
Rows Deep 1 1 1 1 1 1
Fins / Inches 23 23 23 23 23 23
Max. Length 200 200 200 200 200 200
Max. Lift 65 65 65 65 65 65
4
Refrigerant Lines
Max. Drop 150 150 150 150 150 150
Liquid Line Set OD (Field Installed) 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8
Vapor Line Set OD (Field Installed) 3 / 4 3 / 4 3 / 4 3 / 4 7 / 8 7 / 8
Unit Charge (Lbs. - Oz.)
5
2 - 14 3 - 5 4 - 0 4 - 8 5 - 5 5 - 6
Charge Per Foot, Oz. 0.68 0.68 0.68 0.68 0.70 0.70
Operating Weight Lbs. 130 135 195 215 240 250
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. When more than 50 feet of interconnecting tubing and more than 30 feet of vertical lift is used, consult the Application Data (part number
247077). For long-line applications, interconnecting lines over 100 feet must be installed with liquid line solenoid.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add
or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change without notice.
Certified dimensions will be provided upon request.
.
Unit
Model
1
A
Dimensions
(Inches)
B C Liquid Vapor
Refrigerant Connection
Service Valve Size
18 25-1/8 14-5/8 37
24 25-1/8 14-5/8 37
30 37-1/8 17-1/8 44-5/8
36 37-1/8 17-1/8 44-5/8
3/8”
48 43-1/8 17-1/8 44-5/8
60 43-1/8 17-1/8 44-5/8
3/4”
7/8”
1. Including Fan Guard.
2 Johnson Controls Unitary Products
556454-YTG-A-0210
System Charge for Various Matched Systems
Outdoor Unit TCHD18S41S3 TCHD24S41S3 TCHD30S41S3 TCHD36S41S3 TCHD48S41S3 TCHD60S41S3
Required Orifice or TXV
Factory Charge, lbs-oz 2 - 14 3 - 5 4 - 0 4 - 8 5 - 5 5 - 6
1
1TVM4F1 1TVM4F1 1TVM4G1 1TVM4G1 1TVM4J1 1TVM4K1
Indoor Coil
A H P 2 4 –2––––
AHP36 – – 16 12 – –
AHP/SHP60 – – – – 11 –
AHX18 0 0 – – – –
AHX24 10 10 – – – –
AHX30 13 14 10 – – –
AHX36 – 20 16 12 – –
AHX42 – – 27 22 – –
AHX48 – – 26 22 11 –
AHX60 – – – 27 16 13
A V 2 4 22––––
AV36 20 20 16 12 – –
AV/SV48 – – – 22 11 –
A V / S V 6 0 ––––1 18
F*FP030 – 2 0 – – –
F*FP036 – – 8 4 – –
F*FP040 – – 10 7 – –
F*FP042 – – – 7 – –
F*FP048 – – – 16 11 –
F*FP060 – – – – 16 –
F*FV060 – – – 8 11 8
F 6 F P 0 1 8 0–––––
F 6 F P 0 2 4 33––––
F6FP030 14 15 10 – – –
F 6 F P 0 3 6 –1 51 07 – –
F6FP042 – – 20 16 – –
F6FP048 – – 10 7 11 –
F 6 F P 0 6 0 – – – 2 71 61 3
F C / M C / P C 1 8 0–––––
F C / M C / P C 2 4 00––––
F C / M C / P C 3 0 442–––
FC/MC/PC32 13 14 10 6 – –
FC/MC/PC35 13 14 0 6 – –
F C / M C / P C 3 6 6630––
FC/MC/PC37 20 21 16 12 – –
F C / M C / P C 4 2 –931––
F C / M C / P C 4 3 –2 01 60 – –
F C / M C / P C 4 8 – 3 22 72 2 0 –
F C / M C / P C 6 0 ––––1 0–
F C / M C 6 2 ––––1 60
H C 1 8 00––––
HC30 10 10 7 – – –
HC36 13 14 10 6 – –
H C 4 2 – 2 11 61 2 – –
H C 6 0 –––70–
HD24 22 17 – – – –
HD36 28 20 14 11 – –
H D 4 8 – – –3 32 4–
H D 6 0 ––––3 02 2
For notes see Page 4.
2,3
Additional Charge, oz
Johnson Controls Unitary Products 3
556454-YTG-A-0210
System Charge for Various Matched Systems (Continued)
Outdoor Unit TCHD18S41S3 TCHD24S41S3 TCHD30S41S3 TCHD36S41S3 TCHD48S41S3 TCHD60S41S3
Required Orifice or TXV
Factory Charge, lbs-oz 2 - 14 3 - 5 4 - 0 4 - 8 5 - 5 5 - 6
1
1TVM4F1 1TVM4F1 1TVM4G1 1TVM4G1 1TVM4J1 1TVM4K1
Indoor Coil
UC18 1 – – – – –
UC24 5 5 – – – –
UC30 5 5 3 – – –
UC36 7 7 4 1 – –
UC42 – 9 3 0 – –
U C 4 8 – 2 52 11 7 6 –
U C 6 0 ––––1 1–
FOOTNOTES:
1. For applications requiring a TXV use 1TVM series kit.
2. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
3. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For TXV matches requiring additional charge, the refrigerant needs to be weighed in for specific coil match and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator +
2,3
line tubing.
adder for line set.
Additional Charge, oz
4 Johnson Controls Unitary Products
556454-YTG-A-0210
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
TCHD18S41S3
TCHD24S41S3
TCHD30S41S3
TCHD36S41S3
TCHD48S41S3
TCHD60S41S3 MV20D 24 FC/MC62D 1800 57.5 39.5 13.40 11.30
TCHD18S41S3
TCHD24S41S3
TCHD30S41S3 AV*36 21 – 960 28.8 21.3 15.50 13.25
TCHD36S41S3
TCHD48S41S3
TCHD60S41S3
For notes see Page 6.
AIR HANDLER
MODEL W
13 SEER AC WITH MV - VARIABLE SPEED
MV12B 17 FC/MC18B 600 18.0 12.3 14.05 11.85
MV12B 17 FC/MC24B 600 18.4 12.9 14.50 12.15
MV12B 17 FC/MC30B 600 18.4 12.9 14.50 12.15
MV12B 17 FC/MC24B 800 23.6 17.2 14.65 12.25
MV12B 17 FC/MC30B 800 23.6 17.2 14.65 12.25
MV12B 17 FC/MC35B 800 23.6 17.3 14.85 12.20
MV16C 21 FC/MC35C 800 23.6 17.3 14.85 12.20
MV12B 17 FC/MC36B 800 23.6 17.4 14.85 12.20
MV16C 21 FC/MC36C 800 23.6 17.4 14.85 12.20
MV12B 17 FC/MC43B 800 24.2 17.7 15.00 12.45
MV16C 21 FC/MC43C 800 24.2 17.7 15.05 12.55
MV12B 17 FC/MC30B 1000 28.2 20.8 14.60 13.00
MV12B 17 FC/MC35B 1000 28.6 21.2 15.00 13.20
MV16C 21 FC/MC35C 1000 28.6 21.2 15.00 13.25
MV12B 17 FC/MC36B 1000 28.6 21.0 15.00 13.15
MV16C 21 FC/MC36C 1000 28.6 21.0 15.00 13.25
MV12B 17 FC/MC43B 1000 29.0 21.6 15.15 13.35
MV16C 21 FC/MC43C 1000 29.0 21.6 15.35 13.50
MV16C 21 FC/MC48C 1000 29.4 21.8 15.50 13.70
MV12B 17 FC/MC35B 1200 33.6 24.6 14.10 12.20
MV16C 21 FC/MC35C 1200 33.8 24.8 14.55 12.55
MV12B 17 FC/MC36B 1200 33.6 24.2 14.00 12.15
MV16C 21 FC/MC36C 1200 33.8 24.4 14.30 12.50
MV12B 17 FC/MC43B 1200 34.4 25.2 14.50 12.50
MV16C 21 FC/MC43C 1200 34.6 25.4 15.00 13.00
MV16C 21 FC/MC48C 1200 35.0 25.6 15.25 13.10
MV12D 24 FC/MC48D 1150 34.6 25.2 15.00 13.00
MV16C 21 FC/MC48C 1600 47.5 34.2 14.00 12.10
MV20D 24 FC/MC48D 1600 47.5 34.2 14.00 12.00
MV20D 24 FC/MC60D 1600 45.5 33.0 13.50 11.60
MV20D 24 FC/MC62D 1600 48.0 34.6 14.50 12.25
13 SEER AC WITH AV / SV - / F*FV VARIABLE SPEED
AV*24 17 – 610 18.1 13.1 14.25 11.50
AV*36 21 – 630 19.0 13.8 15.00 12.00
AV*24 17 – 800 23.2 17.1 14.25 11.75
AV*36 21 – 725 23.8 17.1 14.50 12.25
AV*36 21 – 1190 34.4 25.3 14.50 12.25
AV/SV*48 24 – 1220 34.8 25.7 15.00 12.75
F*FV060 24 – 1200 33.2 23.8 14.55 12.45
AV/SV*48 24 – 1625 46.5 33.8 13.75 11.75
AV/SV*60 24 – 1560 47.0 34.0 13.75 11.75
F*FV060 24 – 1600 45.5 33.2 13.55 11.60
AV/SV*60 24 – 1730 56.0 37.7 13.25 11.00
F*FV060 24 – 1800 55.0 38.0 13.00 11.00
COIL
MODEL
1
RATED
CFM
TOTAL SENS.
COOLING
NET MBH
SEER EER
Johnson Controls Unitary Products 5
556454-YTG-A-0210
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
MODEL W
COIL
MODEL
1
RATED
CFM
TOTAL SENS.
13 SEER AC WITH AHP / SHP / AHX / F*FP
AHX18 17 – 630 18.2 13.1 14.25 11.75
AHX24 17 – 590 18.3 13.0 14.25 11.75
TCHD18S41S3
AHX30 17 – 610 18.6 13.3 14.50 12.00
F6FP018 17 – 600 17.9 12.6 13.50 11.25
F6FP024 17 – 600 18.5 13.1 14.00 11.50
F6FP030 17 – 620 18.5 13.2 14.00 11.50
AHP24 17 – 850 23.0 16.8 13.15 11.05
AHX18 17 – 835 23.2 17.2 14.00 11.50
AHX24 17 – 800 23.6 17.3 14.00 12.75
AHX30 17 – 820 23.8 17.8 14.50 12.75
TCHD24S41S3
AHX36 21 – 815 24.2 18.1 15.00 12.25
F*FP030 17 – 800 23.0 16.7 13.10 11.00
F6FP024 17 – 840 23.4 17.4 14.00 11.50
F6FP030 17 – 850 23.4 17.4 13.75 11.25
F6FP036 21 – 855 23.8 17.9 14.25 11.75
AHP36 21 – 1000 28.4 21.2 13.75 12.20
AHX30 17 – 1025 28.4 21.3 14.50 12.50
AHX36 21 – 1005 29.0 21.7 15.25 13.25
AHX42 21 – 990 29.4 22.1 15.50 13.75
AHX48 24 – 1090 29.8 23.0 15.50 13.75
TCHD30S41S3
F*FP030 17 – 1000 27.6 20.0 13.20 11.85
F*FP036 21 – 1000 27.8 20.6 13.40 12.00
F*FP040 21 – 1000 27.8 20.4 13.40 12.00
F6FP030 17 – 1035 28.2 20.9 13.75 12.00
F6FP036 21 – 980 28.2 20.7 14.50 12.75
F6FP042 21 – 1065 29.6 22.4 15.25 13.50
F6FP048 24 – 1055 28.0 21.0 14.50 12.50
AHP36 21 – 1200 34.2 25.0 14.00 12.15
AHX36 21 – 1225 34.4 25.7 14.75 12.50
AHX42 21 – 1190 35.0 25.9 15.25 12.75
AHX48 24 – 1255 35.2 26.3 15.25 12.75
AHX60 24 – 1300 35.6 26.8 15.00 12.75
F*FP036 21 – 1200 33.0 23.8 13.00 11.35
TCHD36S41S3
F*FP040 21 – 1200 33.0 24.0 13.00 11.40
F*FP042 21 – 1200 33.0 24.0 13.00 11.40
F5FP048 24 – 1250 35.0 25.8 15.20 13.00
F6FP036 21 – 1210 33.4 24.3 13.75 11.75
F6FP042 21 – 1290 35.2 26.4 14.75 12.50
F6FP048 24 – 1125 32.2 23.3 14.00 11.75
F6FP060 24 – 1240 35.2 26.3 15.00 12.75
AHP/SHP60 24 – 1600 45.5 33.2 13.40 11.50
AHX48 24 – 1660 47.0 34.6 13.75 11.75
AHX60 24 – 1680 47.5 34.8 13.50 11.75
TCHD48S41S3
F5FP048 24 – 1700 47.5 35.0 13.75 12.00
F5FP060 24 – 1700 46.0 33.4 13.35 11.55
F6FP048 24 – 1625 45.0 33.2 13.00 11.00
F6FP060 24 – 1710 48.0 35.0 13.50 11.50
TCHD60S41S3
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8 °F entering air temperature, 50% RH, and rated air flo w.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
AHX60 24 – 1905 57.5 40.2 13.00 11.00
F6FP060 24 – 1710 56.5 38.7 13.00 11.00
COOLING
NET MBH
SEER EER
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
6 Johnson Controls Unitary Products
556454-YTG-A-0210
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
FURNACE**
UNIT MODEL
TCHD18S41S3
TCHD24S41S3
TCHD30S41S3
TCHD36S41S3
TCHD48S41S3
TCHD60S41S3 1600 - 2000 21,24 FC/MC62 1800 57.0 39.5 13.00 11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.
CFM RANGE
(Min.-max.)
450 - 750 14,17 FC/MC/PC24 600 18.0 12.6 13.00 11.00
450 - 750 14,17 FC/MC/PC30 600 18.0 12.6 13.00 11.00
450 - 750 14 FC/MC/PC32 600 18.1 12.6 13.00 11.05
450 - 750 17 FC/MC/PC35 600 18.1 12.6 13.00 11.05
450 - 750 14,17 FC/MC/PC36 600 18.2 12.6 13.00 11.15
450 - 750 14 FC/MC/PC37 600 18.4 12.7 13.10 11.25
450 - 750 17 HC36 600 18.1 12.6 13.00 11.05
450 - 750 14,17 HD24 600 18.7 12.9 13.25 11.35
450 - 750 14,17 UC24 600 18.1 12.6 13.00 11.10
450 - 750 14,17 UC30 600 18.1 12.6 13.00 11.10
600 - 1000 14,17 FC/MC/PC24 800 23.0 16.8 13.00 11.00
600 - 1000 14,17 FC/MC/PC30 800 23.0 16.8 13.00 11.00
600 - 1000 14 FC/MC/PC32 800 23.0 16.9 13.15 11.00
600 - 1000 17,21 FC/MC/PC35 800 23.0 16.9 13.15 11.00
600 - 1000 14,17,21 FC/MC/PC36 800 23.0 16.9 13.15 11.00
600 - 1000 14 FC/MC/PC37 800 23.6 17.3 13.30 11.20
600 - 1000 17,21 FC/MC/PC43 800 23.6 17.3 13.30 11.20
600 - 1000 14 HC30 800 22.8 16.6 13.00 11.00
600 - 1000 17 HC36 800 23.0 16.9 13.15 11.00
600 - 1000 21 HC42 800 23.6 17.3 13.30 11.20
600 - 1000 14,17 UC24 800 23.0 16.9 13.05 11.00
600 - 1000 14,17 UC30 800 23.0 16.9 13.05 11.00
800 - 1200 14,17 FC/MC/PC30 1000 27.6 20.4 13.25 11.85
800 - 1200 14,17 FC/MC/PC32 1000 28.0 20.8 13.50 12.00
800 - 1200 17,21 FC/MC/PC35 1000 28.0 20.8 13.50 12.00
800 - 1200 14,17,21 FC/MC/PC36 1000 28.0 20.6 13.45 12.00
800 - 1200 14 FC/MC/PC37 1000 28.4 21.2 13.75 12.20
800 - 1200 17,21 FC/MC/PC43 1000 28.4 21.2 13.70 12.20
800 - 1200 14,17 HC30 1000 27.6 20.4 13.35 11.80
800 - 1200 17 HC36 1000 28.0 20.8 13.50 12.00
800 - 1200 21 HC42 1000 28.4 21.2 13.75 12.20
800 - 1200 14,17,21 HD36 1000 27.6 20.0 13.30 11.85
800 - 1200 14,17 UC30 1000 27.8 20.4 13.40 12.00
800 - 1200 21,24 UC48 1000 26.8 20.0 13.00 11.50
1000 - 1400 14 FC/MC/PC32 1200 33.2 24.2 13.20 11.50
1000 - 1400 17,21 FC/MC/PC35 1200 33.2 24.2 13.20 11.50
1000 - 1400 14,17,21 FC/MC/PC36 1200 33.0 24.0 13.00 11.40
1000 - 1400 14 FC/MC/PC37 1200 33.8 24.8 13.50 11.70
1000 - 1400 17,21 FC/MC/PC43 1200 34.0 24.8 13.50 11.75
1000 - 1400 21,24 FC/MC/PC48 1200 34.4 25.2 13.65 12.00
1000 - 1400 17 HC36 1200 33.2 24.2 13.20 11.50
1000 - 1400 21 HC42 1200 33.8 25.0 13.50 11.70
1000 - 1400 14,17,21 HD36 1200 32.4 23.2 13.00 11.20
1000 - 1400 14,17,21,24 HD48 1200 34.2 24.8 13.65 11.85
1400 - 1800 21,24 FC/MC/PC48 1600 47.0 33.8 13.25 11.50
1400 - 1800 21,24 FC/MC62 1600 47.5 34.2 13.35 11.60
1400 - 1800 14,17,21,24 HD48 1600 47.0 33.4 13.20 11.50
W
COIL
MODEL
RATED
CFM
TOTAL SENS.
COOLING
NET MBH
SEER
1
EER
Johnson Controls Unitary Products 7
556454-YTG-A-0210
COOLING CAP ACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
TCHD18S41S3
For notes see Page 16.
FURNACE
MODEL
T*(8,L)X*A12 FC/MC/PC18A 14 540 17 .7 12.4 14.00 11.50
T*(8,L)X*B12 FC/MC/PC18B 17 580 17 .9 12.6 14.25 11.75
T*9X*B12 FC/MC/PC18B 17 590 17.9 12.8 14.25 11.75
T*(8,L)X*A12 FC/MC/PC24A 14 595 18.5 13.2 14.70 12.00
T*(8,L)X*B12 FC/MC/PC24B 17 620 18.4 13.1 14.75 12.00
T*9X*B12 FC/MC/PC24B 17 615 18.5 13.2 14.75 12.00
T*(8,L)X*A12 FC/MC/PC30A 14 595 18.5 13.2 14.70 12.00
T*(8,L)X*B12 FC/MC/PC30B 17 620 18.4 13.1 14.75 12.00
T*9X*B12 FC/MC/PC30B 17 615 18.5 13.2 14.75 12.00
T*(8,L)X*A12 FC/MC/PC32A 14 590 18.4 13.1 14.55 12.00
T*(8,L)X*A12 HD24 14 605 19.0 13.9 13.75 12.25
T*(8,L)X*B12 HD24 17 655 18.6 14.3 14.75 12.00
T*(8,L)X*C16 HD24 21 650 18.1 14.0 15.00 11.50
T*9X*B12 HD24 17 630 19.0 13.9 13.75 12.25
T*(8,L)X*A12 UC18A 14 590 18.1 12.8 14.50 11.75
T*(8,L)X*B12 UC18B 17 595 18.0 12.7 14.50 11.75
T*9X*B12 UC18B 17 590 18.1 12.8 14.50 11.75
T*(8,L)X*A12 UC24A 14 570 18.4 13.0 14.75 12.00
T*(8,L)X*B12 UC24B 17 575 18.4 13.0 14.75 12.00
T*9X*B12 UC24B 17 615 18.7 13.5 14.75 12.00
T*(8,L)X*A12 UC30A 14 570 18.4 13.0 14.75 12.00
T*(8,L)X*B12 UC30B 17 625 18.4 13.3 15.00 12.25
T*9X*B12 UC30B 17 615 18.7 13.5 14.75 12.00
Y*(8,L)C*A12 FC/MC/PC18A 14 620 18.1 13.0 14.50 12.05
Y*(8,L)C*B12 FC/MC/PC18B 17 580 17.9 12.7 14.50 12.05
Y*9C*B12 FC/MC/PC18B 17 610 18.1 13.0 14.60 12.20
Y*(8,L)C*A12 FC/MC/PC24A 14 640 18.5 13.4 14.70 12.20
Y*(8,L)C*B12 FC/MC/PC24B 17 575 18.4 13.0 15.00 12.40
Y*9C*B12 FC/MC/PC24B 17 610 18.5 13.4 14.85 12.30
Y*(8,L)C*A12 FC/MC/PC30A 14 640 18.5 13.4 14.70 12.20
Y*(8,L)C*B12 FC/MC/PC30B 17 575 18.4 13.0 15.00 12.40
Y*9C*B12 FC/MC/PC30B 17 610 18.5 13.4 14.85 12.30
Y*(8,L)C*A12 FC/MC/PC32A 14 590 18.4 13.1 14.55 12.20
Y*(8,L)C*B12 FC/MC/PC35B 17 650 18.6 13.4 14.70 12.30
Y*9C*B12 FC/MC/PC35B 17 570 18.4 12.9 14.70 12.30
Y*(8,L)C*C16 FC/MC/PC35C 21 600 18.6 13.4 15.05 12.55
Y*9C*C16 FC/MC/PC35C 21 645 18.6 13.4 14.85 12.40
Y*(8,L)C*A12 FC/MC/PC36A 14 645 18.7 13.4 14.80 12.35
Y*(8,L)C*B12 FC/MC/PC36B 17 650 18.7 13.5 15.00 12.45
Y*9C*B12 FC/MC/PC36B 17 635 18.7 13.5 15.00 12.45
Y*(8,L)C*C16 FC/MC/PC36C 21 595 18.8 13.5 15.20 12.65
Y*9C*C16 FC/MC/PC36C 21 595 18.8 13.5 15.20 12.65
Y*(8,L)C*A12 FC/MC/PC37A 14 625 18.7 13.5 14.80 12.35
Y*(8,L)C*A12 HC18 14 620 18.1 13.0 14.50 12.05
Y*(8,L)C*A12 HC30 14 590 18.2 12.8 14.50 12.05
Y*(8,L)C*B12 HC36 17 650 18.7 13.6 14.75 12.40
Y*9C*B12 HC36 17 570 18.4 12.9 14.70 12.30
Y*(8,L)C*A12 HD24 14 640 19.1 13.8 15.10 12.60
Y*(8,L)C*B12 HD24 17 575 19.0 13.4 15.30 12.75
Y*9C*B12 HD24 17 610 19.2 13.9 15.20 12.70
Y*(8,L)C*A12 HD36 14 645 18.5 12.9 14.60 12.25
Y*(8,L)C*B12 HD36 17 650 18.5 12.9 14.70 12.30
Y*(8,L)C*C16 HD36 21 595 18.6 12.9 15.00 12.50
COIL
1
MODEL
13 SEER AC WITH VARIABLE SPEED FURNACES
W
RATED
CFM
COOLING
Net MBH
TOTAL SENS.
2
SEER EER
8 Johnson Controls Unitary Products
COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
TCHD18S41S3
TCHD24S41S3
For notes see Page 16.
FURNACE
MODEL
Y*9C*B12 HD36 17 635 18.5 12.9 14.75 12.35
Y*9C*C16 HD36 21 595 18.6 12.9 15.00 12.50
Y*(8,L)C*A12 UC18A 14 620 18.2 13.1 14.55 12.10
Y*(8,L)C*B12 UC18B 17 580 18.0 12.7 14.50 12.15
Y*9C*B12 UC18B 17 610 18.2 13.1 14.70 12.25
Y*(8,L)C*A12 UC24A 14 640 18.6 13.4 14.75 12.30
Y*(8,L)C*B12 UC24B 17 575 18.4 13.1 15.00 12.45
Y*9C*B12 UC24B 17 610 18.7 13.4 14.85 12.40
Y*(8,L)C*A12 UC30A 14 640 18.6 13.4 14.75 12.30
Y*(8,L)C*B12 UC30B 17 575 18.4 13.1 15.00 12.45
Y*9C*B12 UC30B 17 610 18.7 13.4 14.85 12.40
Y*(8,L)C*A12 UC36A 14 645 18.1 13.3 14.60 12.15
Y*(8,L)C*B12 UC36B 17 650 18.1 13.3 14.70 12.20
Y*9C*B12 UC36B 17 635 18.1 13.4 14.75 12.25
Y*(8,L)C*C16 UC36C 21 595 17.9 12.8 14.60 12.25
Y*9C*C16 UC36C 21 595 17.9 12.8 14.75 12.30
T*(8,L)X*A12 FC/MC/PC24A 14 775 23.4 17.3 14.50 11.75
T*(8,L)X*B12 FC/MC/PC24B 17 835 23.6 17.7 14.50 12.00
T*9X*B12 FC/MC/PC24B 17 775 23.4 17.3 14.50 11.75
T*(8,L)X*A12 FC/MC/PC30A 14 775 23.4 17.2 14.25 11.75
T*(8,L)X*B12 FC/MC/PC30B 17 835 23.6 17.7 14.50 12.00
T*9X*B12 FC/MC/PC30B 17 775 23.4 17.2 14.25 12.00
T*(8,L)X*A12 FC/MC/PC32A 14 800 23.6 17.6 14.75 12.00
T*(8,L)X*B12 FC/MC/PC35B 17 850 23.6 17.8 14.75 12.00
T*(8,L)X*C16 FC/MC/PC35C 21 625 22.8 15.9 14.25 11.75
T*(8,L)X*C20 FC/MC/PC35C 21 885 23.6 18.1 14.75 12.00
T*9X*B12 FC/MC/PC35B 17 785 23.8 17.7 14.75 12.00
T*9X*C16 FC/MC/PC35C 21 715 23.4 16.9 14.50 12.00
T*9X*C20 FC/MC/PC35C 21 825 23.6 17.6 14.50 12.00
T*(8,L)X*A12 FC/MC/PC36A 14 815 23.6 17.7 14.50 12.00
T*(8,L)X*B12 FC/MC/PC36B 17 835 23.8 17.8 14.75 12.00
T*(8,L)X*C16 FC/MC/PC36C 21 675 23.2 16.4 14.50 11.75
T*9X*B12 FC/MC/PC36B 17 775 23.6 17.6 14.50 12.00
T*9X*C16 FC/MC/PC36C 21 770 23.8 17.4 14.75 12.25
T*9X*C20 FC/MC/PC36C 21 810 23.6 17.6 14.50 12.00
T*(8,L)X*A12 FC/MC/PC37A 14 840 24.0 18.2 14.40 12.00
T*(8,L)X*B12 FC/MC/PC42B 17 865 24.2 18.4 14.75 12.00
T*(8,L)X*C16 FC/MC/PC42C 21 725 23.6 17.0 14.50 12.00
T*9X*B12 FC/MC/PC42B 17 805 23.8 17.8 14.75 12.00
T*9X*C16 FC/MC/PC42C 21 805 23.8 17.9 15.00 12.25
T*9X*C20 FC/MC/PC42C 21 790 23.6 17.6 14.50 12.00
T*(8,L)X*B12 FC/MC/PC43B 17 865 24.0 18.5 14.70 12.25
T*(8,L)X*C16 FC/MC/PC43C 21 655 23.0 16.2 14.25 11.75
T*9X*B12 FC/MC/PC43B 17 800 24.0 18.0 14.75 12.00
T*9X*C16 FC/MC/PC43C 21 735 23.6 17.2 14.75 12.00
T*9X*C20 FC/MC/PC43C 21 790 24.0 17.8 14.50 12.00
T*(8,L)X*C16 FC/MC/PC48C 21 685 23.6 16.8 14.50 12.00
T*9X*C16 FC/MC/PC48C 21 770 24.2 17.9 15.00 12.25
T*9X*C20 FC/MC/PC48C 21 815 24.2 18.2 14.75 12.00
T*(8,L)X*A12 HD36 14 815 23.0 17.0 14.25 11.75
T*(8,L)X*B12 HD36 17 855 23.0 17.0 14.25 11.75
T*(8,L)X*C16 HD36 21 855 23.0 17.0 14.25 11.75
COIL
1
MODEL
13 SEER AC WITH VARIABLE SPEED FURNACES
W
RATED
CFM
TOTAL SENS.
Net MBH
2
556454-YTG-A-0210
COOLING
SEER EER
Johnson Controls Unitary Products 9