GAS-FIRED
CONDENSING / HIGH EFFICIENCY
TWO STAGE VARIABLE
UPFLOW FURNACES
UP TO 94% AFUE
NATURAL GAS
40 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
Due to continuous product improvement, specific ations
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
036-21584-001 Rev. B (1004)
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room
or garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented
using approved plastic type combustion air and vent piping.
All units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the
original purchaser; a 20-year limited warranty from original
installation date to subsequent purchaser.
10-year warranty on commercial applications.
5-year limited parts warranty.
FEATURES
•Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation
•Provides increased comfort level & very quiet unit operation
•Adjustable delay timer allows two stage operation with
single stage thermostat
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
tion.
• Integrated control module for reliable, economical opera-
tion.
• High velocity filter and side -return filter rack provided for
easy field installation.
• May be installed as either two-pipe (sealed combustion)
or single pipe vent (using indoor combustion air)
• Top intake & vent connection allows installation in narrow
locations.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied
Three elbows (two in vent pipe and one in the air intake pipe) are already accounted for and need not be included in the elbow count from the Table
above.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
High/Low
MBHMBHCFM%°F°FHP AmpsIn.Amps
Output
High/Low
Nominal
Airflow
AFUE
Air Temp.
Rise
Max. Outlet
Air Temp.
Blower
Blower
Size
Total Unit
Max.
Over-current
Protect
Min. Wire Size
(awg) @ 75 ft.
One Way
FILTER SIZES
ModelsCFM Cabinet SizeSide Return Filter in. (cm)Bottom Return Filter in. (cm)
PV9A12N040UP111200A16 x 2514 x 25
PV9B12N060UP111200 B16 x 25 16 x 25
PV9B12N080UP111200B16 x 25 16 x 25
PV9C16N080UP111600 C16 x 25 20 x 25
PV9C20N100UP112000 C16 x 25 20 x 25
PV9D20N120UP112000 D(2) 16 x 2522 x 25
* ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
NOTES:
1. All filters must be high velocity cleanable type.
2. Air flows above 1800 CFM require either return from two sides or one side plus bottom.
Unitary Products Group3
Page 4
036-21584-001 Rev. B (1004)
AIR FLOW DATA
40,000 INPUT - 3 Ton60,000 INPUT - 3 Ton
CFM m³/min CFM m³/min
High Low High Low High Low High Low COOL Tap ADJ Tap
134099538.028.2133090037.725.5A B
120588534.125.1113080032.022.7B B
125592035.626.1122085034.624.1A A
115083532.623.7104073029.420.7B A
117085533.224.2112077031.721.8A C
102575529.021.492065026.118.4C B
104578029.622.195066026.918.7B C
83562523.717.774054021.015.3D B
95070526.920.086061024.417.3C A
78559022.216.769054019.515.3D A
86566524.518.879057022.416.1C C
72560520.517.163053017.815.0D C
80,000 INPUT - 3 Ton80,000 INPUT - 4 Ton
CFM m³/min CFM m³/min
High Low High Low High Low High Low COOL Tap ADJ Tap*
131089037.125.21660111047.031.4A B
110074031.221.01550105043.929.7B B
122083034.623.51610107045.630.3A A
100067028.319.0144096040.827.2B A
109072030.920.4147099041.628.0A C
90061025.517.3137092038.826.1C B
88061024.117.3129085036.524.1BC
68051019.314.4113079032.022.4DB
81058022.916.4123085034.824.1CA
63050017.814.2105072029.720.4DA
73053020.715.0111076031.421.5CC
59050016.714.295066026.918.7D C
100,000 INPUT - 5 Ton120,000 INPUT - 5 Ton
CFM m³/min CFM m³/min
High Low High Low High Low High Low COOL Tap ADJ Tap*
2210148062.641.92280151064.642.8A B
1780118050.433.41860119052.733.7B B
2040135057.838.22090137059.238.8A A
1620105045.929.71630106046.230.0B A
1840125052.135.41880125053.235.4A C
1560101044.228.61620103045.929.2C B
147094041.626.6150096042.527.2BC
137089038.825.2141088039.924.9DB
146093041.326.3149092042.226.1CA
125079035.422.4129079036.522.4DA
131081037.122.9136084038.523.8CC
109069030.919.5114069032.319.5D C
40,000 INPUT - 3 Ton60,000 INPUT - 3 Ton
CFM m³/min CFM m³/min
High Low High Low High Low High Low HEAT Tap ADJ Tap*
104574029.621.0111071031.420.1 A Any
90564525.618.396064027.218.1B Any
82559523.416.887060024.617.0C Any
76559021.716.783057023.516.1D Any
80,000 INPUT - 3 Ton80,000 INPUT - 4 Ton
CFM m³/min CFM m³/min
High Low High Low High Low High Low HEAT Tap ADJ Tap*
133088037.724.9149099042.228.0A Any
118081033.422.9135090038.225.5B Any
110073031.220.7122082034.623.2C Any
101067028.619.0112077031.721.8D Any
100,000 INPUT - 5 Ton120,000 INPUT - 5 Ton
CFM m³/min CFM m³/min
High Low High Low High Low High Low HEAT Tap ADJ Tap*
1880123053.234.82150142060.940.2 A Any
1670108047.330.61930129054.736.5 B Any
153098043.327.81850119052.433.7 C Any
143090040.525.51660107047.030.3 D Any
All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to pr ovide cons tant CF M from 0. 0” to 0.6” w.c. static pressure. From
0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external static pressure is not recommended.
NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Consult the
instructions for the electron ic air cleaner for further details.
The ADJ “D” tap should not be used.
HIGH / LOW SPEED COOLING AND HEAT PUMP CFM
JUMPER SETTINGS
JUMPER SETTINGS
JUMPER SETTINGS
HIGH / LOW HEAT CFM
JUMPER SETTINGS
JUMPER SETTINGS
JUMPER SETTINGS
4Unitary Products Group
Page 5
036-21584-001 Rev. B (1004)
BLK
WHT
GRN
BLK (HOT)
WHT (NEUTRAL)
GRN
NOMINAL
120 VOLT
LINE WIRING CONNECTIONS
ROOM
THERMOSTAT
R
W1
W2
G
Y1
Y2
C
TWO-STAGE HEATING AND TWO-STAGE COOLING
FURNACE
CONTROL
R
W1/W
Y/Y2
TO AIR CONDITIONER
CONTROLS
W2
G
Y1
C
COMMON T’STAT CONNECTION
THERMOSTAT CONNECTIONS
CONDENSING
UNIT
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table listed above represents blower performance
WITHOUT filters. To determine the approximate blower performance of the system, apply the filter drop value for the fil-
ROOM
THERMOSTAT
R
W
G
Y
C
ROOM
THERMOSTAT
R
W
G
Y1
Y2
C
SINGLE STAGE HEATING AND TWO-STAGE COOLING
FURNACE
CONTROL
R
W1/W
Y/Y2
SINGLE STAGE HEATING
THERMOSTAT CONNECTIONS
FURNACE
CONTROL
R
W1/W
G
Y1
Y/Y2
C
COMMON T’STAT CONNECTION
TO AIR CONDITIONER
CONTROLS
G
C
COMMON T’STAT CONNECTION
TO AIR CONDITIONER
CONTROLS
THERMOSTAT CONNECTIONS
NOTE: The filter pressure drop values in the “Filter Performance” table shown below are typical values for the type of
filter listed and should only be used as a guideline. Actual
pressure drop ratings for each filter type vary between filter
manufacturer.
CONDENSING
UNIT
CONDENSING
UNIT
ter being used or select an appropriate value from the “Filter
Performance” table shown below.
FILTER PERFORMANCE - PRESSURE DROP INCHES W.C. AND (KPA)
* Washable Fibers are the type supplied with furnace (if supplied.
APPLYING FILTER PRESSURE DROP TO
DETERMINE SYSTEM AIRFLOW
To determine the approximate airflow of the unit with a filter in
place, follow the steps below:
1.Select the filter type.
2.Select the number of return air openings or calculate the
return opening size in square inches to determine the
proper filter pressure drop.
4.Select a filter pressure drop from the table based upon
the number of return air openings or return air opening
size and add to the ESP from Step 3 to determine the
total system static.
5.If total system static matches a ESP value in the airflow
table (i.e. 0.20, 0.60, etc,) the system airflow corresponds to the intersection of the ESP column and Model/
Blower Speed row.
3.Determine the External System Static Pressure (ESP)
without the filter.
Unitary Products Group5
Page 6
036-21584-001 Rev. B (1004)
ACCESSORIES
PROPANE (LP) CONVERSION KIT -
1NP0580 - All units
This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation. Conversions must
be made by qualified distributor or dealer personnel.
CONCENTRIC VENT TERMINATION -
1CT0302 (2")
1CT0303 (3")
For use through rooftop, sidewall. Allows combustion air to
enter and exhaust to exit through single common hole.
CONDENSATE NEUTRALIZER KIT - 1NK0301
Neutralizer cartidge has a 1/2" plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also
avaiable from the Source 1 Parts (p/n 026-30228-000).
Sidewall Vent Termination - 1HT0901
EXTERNAL BOTTOM RETURN FILTER RACK W/FILTER -
Provides a cleanable, high velocity type filter and filter rack.
Attaches to the bottom of the furnace.
1BR0314 - For 14-1/2” cabinets
1BR0317 - For 17-1/2" cabinets
1BR0321 - For 21" cabinets
1BR0324 - For 24-1/2" cabinets
HIGH ALTITUDE PRESSURE SWITCHES -
These accessory kits may be used to convert units for high
altitude operation. Conversion must be made by qualified distributor or dealer personnel.
1PS0501
1PS0502
1PS0503
1PS0504
1PS0505
1PS0506
HIGH ALTITUDE PRESSURE
SWITCH KIT
(Does Not Include Orifices)
For use on sidewall, two-pipe installations only. Provides a
more attractive termination for locations where the terminal is
visible on the side of the home.
FIELD INSTALLED ACCESSORIES - ELECTRICAL
MODEL NO.DESCRIPTIONUSED WITH
2TH07700124
2TH13700424
2TB17700424
2ET07700224
THERMOSTAT- One-stage heat/cool. Manual changeover, integral subbase.
System Switch: Cool-Off-Heat. Fan Switch: Auto-On.
THERMOSTAT- One-stage heat. Deluxe 24V with heat only subbase, does not
include fan switch. NOTE: For one-stage cool or one-stage heat/cool, must be
used with subbase 2TB17700424.
SUBBASE (24V) - One-stage heat/cool. Manual changeover, integral subbase.
System Switch: Cool-Off-Heat. Fan Switch: Auto-On.
THERMOSTAT- One-stage heat/cool. Programmable changeover, with sub-
base. System Switch: Cool-Off-Heat. Fan Switch: Auto-On.