036-21023-005 Rev. A (0802)
TECHNICAL GUIDE
STEALTH
SPLIT-SYSTEM AIR CONDITIONERS
15 + SEER
MODELS:
H4TS024 THRU 060
(2 THRU 5 NOMINAL TONS)
O
T
A
R
D
I
E
I
A
F
S
I
T
R
C
E
C
R
E
R
U
T
C
A
F
U
N
A
M
C
E
A
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Y
R
A
T
I
N
U
R
E
Q
N
U
I
E
P
M
R
T
I
F
I
C
A
T
R
I
S
O
N
I
S
T
A
A
N
D
WITH ARI.
O
M
A
P
I
R
-
L
C
O
Y
N
I
D
I
N
T
G
I
O
N
I
W
N
I
G
T
H
T
F
O
S
N
O
I
T
0
C
E
1
2
D
R
LISTED
DESCRIPTION
The HTS Stealth series condensing units use Twin Single
compressor technology to provide cooling efficiencies up to
15.5 SEER. They are to be installed with the matching variable speed enhanced Air Handler or Diamond Furnace, or
with a two-stage or single-stage indoor unit, a corresponding
coil and sweat connect lines. A factory specified balanced
port hard shut-off TXV kit must be used for proper installation
and optimum performance.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed of
copper tube and hardened aluminum fins for durability and
long lasting efficient operation. The fins on the unit are protected with a decorative grille.
• DURABLE FINISH - Cabinet is made of powder painted steel
over pre-primered steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and
rust creep. Special primer formulas and automotive quality finish insure less fading when exposed to sunlight.
• PROTECTED COMPRESSORS - The Twin Single com-
pressor is protected against high and low pressure. Hard start
components are included to ensure start-up under adverse
conditions. All models have standard crankcase heat for
added protection.
• OPTIMUM PERFORMANCE - The solid-state electronic controlboard optimizes the compressor staging based on load
requirements, provides a 5-minute anti-short cycle timer for
the compressor, and simplifies troubleshooting with built in
self diagnostics.
• LOWER INSTALLED COST - Installation time and costs are
reduced by easy power and control wiring connections. All
units contain enough refrigerant for the smallest matching
indoor coil and 15 feet of interconnecting piping. The small
base dimension means less space is required on the ground
or roof.
• EFFECTIVE HUMIDITY CONTROL - The inherent design of
the Stealth system and the staging operation of the Twin Single compressor provide effective humidity control at the lowest possible operating cost. An optional dehumidification
control accessory is available to maintain the humidity at a set
desired level.
• TOP DISCHARGE - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
• LOW OPERATING SOUND LEVEL - The upward air flow car-
ries the normal operating noise up away from the living area.
The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser
coil muffle the normal fan motor and compressor operating
sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor- bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant connections and a single panel covering the electrical controls
make servicing easy. Easy access for coil cleaning is also provided.
• RE-USABLE SERVICE VALVES - Provided on both the liquid
and vapor sweat connections for ease of evacuating and
charging.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
Additional rating information can be found at
www.ariprimenet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
036-21023-005 Rev. A (0802)
PHYSICAL AND ELECTRICAL DATA
MODEL
UNIT SUPPLY VOLTAGE
NORMAL VOLTAGE RANGE
MIN. CIRCUIT AMPACITY
MAX. OVERCURRENT DEVICE AMPS
COMPRESSOR TYPE
COMPRESSOR AMPS
CRANKCASE HEATER
FAN MOTOR AMPS RATED LOAD
FAN DIAMETER INCHES
FAN MO TOR
COIL
LIQUID LINE OD
VAPOR LINE OD
UNIT CHARGE, (LBS - OZ)
CHARGE PER FOOT, OZ
OPERATING WEIGHT LBS.
1
2
RATED LOAD
LOCKED ROTOR
RATED HP
NOMINAL RPM
NOMINAL CFM
FACE AREA SQ. FT
COIL ROWS DEEP
FIN / INCH
3
H4TS024 H4TS030 H4TS036 H4TS048 H4TS060
208/230-1-60
187 to 252
13.4 15.3 18.6 32.8 35.3
20 25 30 50 60
BRISTOL TS
10.3 11.7 13.5 25.7 27.0
64 65 84 135 147
YES YES YES YES YES
.5 .5 .7 .7 1.5
18 18 24 24 24
1/12 1/12 1/10 1/10 1/4
1100 1100 825 825 850
1850 1850 2800 2800 3200
14.2 14.2 20.0 24.0 24.0
11111
20 20 20 20 20
3/8 3/8 3/8 3/8 3/8
3/4 3/4 7/8 7/8 7/8
6 - 0 6 - 4 7 - 0 9 - 12 9 - 2
.68 .68 .70 .70 .70
145 145 200 250 252
1 Rated in accordance with ARI Standard 110, utilizaton range “A”.
2 Dual element fuses or HACR circuit breaker.
3 The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or sub-
tract the amount of refrigerant calculated, using the difference in length multiplied by the per foot value.
48" OVERHEAD
CLEARANCE
B
A
VAPOR
CONNECTION
LIQUID CONNECTION
3-1/8
C
AIR IN
4 SIDES
5-1/2
2-3/8
DIMENSIONS
UNIT
MODEL
A
024
030
036
048
060
30-1/8 24 24
30-1/8 24 24
31-7/8 35 35
37-7/8 35 35
37-7/8 35 35
DIMENSIONS
(INCHES)
1
B C Liquid Vapor
REFRIGERANT
CONNECTION
LINE SIZE
3/4
3/8
7/8
2 Unitary Products Group
036-21023-005 Rev. A (0802)
COOLING CAPACITY -With Air Handler Coils
UNIT
MODEL
H4TS024 N+VSB12 5,7.5,10,15,18 17
H4TS030
H4TS036 N-VSC16 5,7.5,10,15,20 21
H4TS048
H4TS060 N-VSD20 5, 7.5,10,15,20 24
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
VAR SPEED AIR HANDLER
MODEL
N-VSB12 5,7.5,10,15,18 17
N-VSC16 5,7.5,10,15,20 21 G2FD042S21
N-VSC16 5, 7.5,10,15,20 21 G2FD048S21
N-VSD20 5, 7.5,10,15,20 24
ELEC. HEAT
KW
W
COIL MODEL
G2FD024S17
G2FD030S17
G2FD036S17
G2FD030S17
G2FD036S17
G2FD036S21
G2FD042S21
G2FD048S21
G2FD048S24
G2FD060S24
G2FD060S24
G2FD061H24
STAGE
(# CYL)
RATED
CFM
1 600 12.4 10.0
2 820 24.0 16.8 12.0
1 600 12.8 10.2
2 820 24.6 17.2 12.5
1 600 13.0 10.4
2 820 25.0 17.5 12.5
1 670 15.0 12.0
2 1035 30.0 21.6 11.0
1 670 15.4 12.2
2 1035 31.0 22.0 11.0
1 690 16.4 13.4
2 1065 31.6 23.4 11.2
1 770 20.0 16.0
2 1185 35.0 26.0 11.3
1 770 20.0 16.0
2 1185 35.0 26.0 11.3
1 770 20.6 16.6
2 1185 36.0 26.6 12.5
1 1050 25.0 20.0
2 1605 47.5 35.0 10.4
1 1050 25.0 20.0
2 1570 47.5 35.0 10.5
1 1050 25.0 21.0
2 1570 49.5 37.0 10.7
1 1250 33.0 26.4
2 1900 59.0 43.0 10.4
1 1250 33.0 26.4
2 1900 59.5 44.0 10.7
COOLING
NET MBH
TOTAL SENS.
SEER EER
14.8
15.4
15.5
14.0
14.5
15.3
15.0
15.0
16.0
15.2
15.3
15.5
14.5
15.0
13.5
14.0
14.3
12.7
13.1
14.1
13.7
13.7
14.4
14.1
14.2
14.0
13.5
14.0
* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
**
Refer to Quick Selection Chart for specific furnace match-up.
ACCESSORIES*
Enhanced Coil Guard - An enhanced coil guard which offers
superior protection from hail and other types of damage is
available.
* For the most current accessory information, refer to the
price book or consult factory.
SOUND RATINGS*
UNIT MODEL
024 70 db 72 db
030 72 db 74 db
SOUND RATINGS
DECIBELS
1 CYLINDER 2 CYLINDER
036 73 db 74 db
048 76 db 78 db
060 78 db 79 db
*Rated in accordance with ARI Standard 270.
Unitary Products Group 3
036-21023-005 Rev. A (0802)
COOLING CAPACITY - Variable Speed Furnace
UNIT
MODEL
H4TS024
H4TS030
VARIABLE SPEED
FURNACE MODEL
P1XUB12V055 17
P1DUA12V064 14
P1XUB12V055 17
P1XUC16V075 21
P1DUA12V064 14
P1DUB16V080 17
WCOIL MODEL
G1UA036S17
G1FA036S17
G2FD024S17
G2FD030S17
G2FD036S17
G2FD046S17
G1UA030S14
G1FA030S14
G1UA036S14
G1FA036S14
G1UA036S17
G1FA036S17
G1UA048S17
G1FA048S17
G2FD030S17
G2FD036S17
G2FD046S17
G1UA036S21
G1FA036S21
G1UA048S21
G1FA048S21
G2FD036S21
G2FD042S21
G2FD048S21
G1UA036S14
G1FA036S14
G1UA036S17
G1FA036S17
G1UA048S17
G1FA048S17
G2FD030S17
G2FD036S17
G2FD046S17
STAGE
(# CYL)
RATED
CFM
1 600 12.6 10.2
2 820 24.4 17.2 11.7
1 600 12.6 10.2
2 820 24.4 17.2 11.7
1 600 12.4 10.2
2 820 23.8 16.8 11.5
1 600 12.6 10.2
2 820 24.4 17.2 11.6
1 600 12.8 10.2
2 820 25.0 17.4 11.7
1 600 12.8 10.4
2 820 25.0 17.4 11.7
1 600 12.4 10.0
2 820 23.8 16.8 11.3
1 600 12.4 10.0
2 820 23.8 16.8 11.3
1 600 12.6 10.2
2 820 24.4 17.2 11.7
1 600 12.6 10.2
2 820 24.4 17.2 11.7
1 670 15.4 13.4
2 1035 29.8 21.6 11.1
1 670 15.4 13.4
2 1035 29.8 21.6 11.1
1 670 15.0 12.2
2 1035 29.6 21.6 11.3
1 670 15.0 12.2
2 1035 29.6 21.6 11.3
1 670 15.4 12.2
2 1035 29.8 21.6 11.0
1 670 15.0 12.0
2 1035 29.6 21.6 11.0
1 670 15.0 12.0
2 1035 29.6 21.6 11.2
1 690 15.0 12.0
2 1065 29.6 21.6 11.0
1 690 15.0 12.0
2 1065 29.6 21.6 11.0
1 690 15.4 12.2
2 1065 29.4 21.4 11.0
1 690 15.4 12.2
2 1065 29.4 21.4 11.0
1 670 15.4 12.2
2 1065 29.4 21.4 11.0
1 690 16.0 13.0
2 1065 31.4 23.0 11.4
1 690 16.0 13.0
2 1065 31.4 23.0 11.4
1 670 15.4 12.2
2 1035 30.2 22.0 11.0
1 670 15.4 12.2
2 1035 30.2 22.0 11.0
1 670 15.4 12.2
2 1035 29.8 21.6 11.0
1 670 15.4 12.2
2 1035 29.8 21.6 11.0
1 670 15.0 12.0
2 1035 29.6 21.6 11.2
1 670 15.0 12.0
2 1035 29.6 21.6 11.2
1 670 15.0 12.0
2 1035 29.8 21.6 11.0
1 670 15.0 12.0
2 1035 29.6 21.6 11.0
1 670 15.0 12.0
2 1035 29.6 21.6 11.2
COOLING
NET MBH
TOTAL SENS.
SEER EER
15.0
15.0
15.0
15.3
15.5
15.5
14.0
14.0
14.5
14.5
13.7
13.7
14.0
14.0
13.7
14.1
14.5
14.5
14.5
14.5
14.5
14.5
15.5
15.5
13.7
13.7
14.0
14.0
14.4
14.4
14.0
14.4
14.6
13.7
13.7
13.0
13.5
13.7
13.7
13.0
13.0
13.7
13.7
12.5
12.5
12.7
12.7
13.0
13.2
13.5
13.0
13.0
13.0
13.0
13.0
13.9
13.9
12.5
12.5
13.0
13.0
13.0
13.0
13.0
13.2
13.6
4 Unitary Products Group
COOLING CAPACITY - Variable Speed Furnace (Continued)
UNIT
MODEL
H4TS036
H4TS048
H4TS060
VARIABLE SPEED
FURNACE MODEL
P1XUB12V055
P1DUB16V080
P1XUC16V075 21
P1XUC20V095
P1DUC20V096
P1XUD20V112 24 G2FD048S24
P1XUC16V075
P1XUC20V095
P1DUC20V096
P1XUD20V112 24
P1XUC20V095
P1DUC20V096
P1XUD20V112 24
WCOIL MODEL
G1UA048S17
17
17
21
21
21
G1FA048S17
G2FD036S17
G2FD046S17
G1UA048S21
G1FA048S21
G2FD036S21
G2FD042S21
G2FD048S21
G1UA048S21
G1FA048S21
G2FD036S21
G2FD042S21
G2FD048S21
G1UA048S21
G1FA048S21
G1UA060S21
G1FA060S21
G2FD048S21
G1UA060S24
G1FA060S24
G2FD048S24
G2FD060S24
G1UA060S21
G1FA060S21
G1UA060S24
G1FA060S24
G2FD060S24
G2FD061H24
036-21023-005 Rev. A (0802)
STAGE
(# CYL)
RATED
CFM
1 750 20.0 16.0
2 1150 34.8 26.0 11.0
1 750 20.0 16.0
2 1150 34.8 26.0 11.0
1 750 20.0 16.0
2 1150 34.8 26.0 11.0
1 750 20.0 16.0
2 1150 34.8 26.0 11.0
1 770 21.0 16.6
2 1185 36.8 27.0 11.6
1 770 21.0 16.6
2 1185 36.8 27.0 11.6
1 770 20.4 16.0
2 1185 35.4 26.0 11.4
1 770 20.4 16.0
2 1185 35.4 26.0 11.4
1 770 21.0 16.6
2 1185 36.8 27.0 11.6
1 770 21.0 16.0
2 1200 37.0 27.0 11.6
1 770 21.0 16.0
2 1200 37.0 27.0 11.6
1 770 20.4 16.4
2 1200 35.4 26.0 11.4
1 770 20.4 16.4
2 1200 35.4 26.0 11.4
1 770 21.0 16.6
2 1200 37.0 27.0 11.6
1 770 21.0 16.6
2 1200 37.0 27.0 11.6
1 1050 24.0 19.0
2 1500 47.5 35.0 10.2
1 1050 24.0 19.0
2 1500 47.5 35.0 10.2
1 1050 25.0 20.0
2 1500 49.0 36.0 10.4
1 1050 25.0 20.0
2 1500 49.0 36.0 10.4
1 1050 24.0 19.0
2 1500 47.5 35.0 10.2
1 1050 25.2 20.2
2 1500 49.5 36.5 10.5
1 1050 25.2 20.2
2 1500 49.5 36.5 10.5
1 1050 24.0 19.0
2 1500 47.5 35.0 10.3
1 1050 25.2 20.2
2 1500 49.5 37.5 10.5
1 1250 33.0 26.4
2 1900 59.0 43.0 10.0
1 1250 33.0 26.4
2 1900 59.0 43.0 10.0
1 1250 33.0 26.4
2 1900 59.0 43.0 10.4
1 1250 33.0 26.4
2 1900 59.0 43.0 10.4
1 1250 33.0 26.4
2 1900 59.0 43.0 10.4
1 1250 34.0 27.0
2 1900 60.0 44.0 10.6
COOLING
NET MBH
TOTAL SENS.
SEER EER
14.5
14.5
14.5
14.5
15.0
15.0
15.0
15.0
15.5
15.5
15.5
15.0
15.0
15.5
15.5
14.5
14.5
14.7
14.7
14.7
15.0
15.0
14.8
15.0
13.7
13.7
14.0
14.0
14.0
14.3
13.4
13.4
13.4
13.4
14.1
14.1
13.6
13.6
14.1
14.3
14.3
13.7
13.7
14.2
14.2
13.5
13.5
13.3
13.3
13.9
13.8
13.8
14.0
13.8
12.6
12.6
13.1
13.1
13.1
13.1
Unitary Products Group 5