York H4DH018, 060 User Manual

Page 1
V
036-21020-003 Rev. C (0203)
TECHNICAL GUIDE
STELLAR PLUS
SPLIT-SYSTEM AIR CONDITIONERS
12 SEER
MODELS:
H4DH018 THRU 060 (1.5 THRU 5 NOMINAL TONS)
This product was manufactured in a plant whose quality system is certified/registered as being in conformity with ISO 9001.
isit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at www.ariprimenet.org.
TM
O
T
A
R
D
I
E
I
A
F
S
I
T
R
E
C
A
I
R
R
-
C
E
O
N
R
Y
D
R
U
A
T
T
I
C
N
U
A
F
U N
A
M
R
E
C
T
Q
N
U
E
I
E
P
M
R T
I
N
F
O
I
I
A
C
T
A
C
T
R
E
I
S
O
N
I
2
S
D
T
R
A
A
N
D
Certification applies only
when the complete
system is listed
with ARI.
C
O
M
P
L
Y
I
I
N
T
G
I
O
N I
W
N
I
G
T
H
F
O
S
0
1
LISTED
DESCRIPTION
The HDH Series condensing unit is the outdoor part of a ver­satile system of air conditioning. It is designed to be custom­matched with one of York’s complete line of evaporator sec­tions, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal application to provide a complete system. Electric heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces.
WARRANTY
5-year limited parts warranty. 10-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed of enhanced copper tube and aluminum fins.
COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard.
PROTECTED COMPRESSOR - The compressor is inter­nally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating condi­tions occur.
DURABLE FINISH - Cabinet is made of powder painted steel over pre-primered steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and automotive quality finish insure less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connec­tions. Hard start kits are available for non-scroll models. All units contain enough refrigerant for a matching indoor coil and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscap­ing. This allows compact location on multi-unit applica­tions.
LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated motor bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con­nections and a single panel covering the electrical controls make servicing easy.
SECURED SERVICE VALVES -Provided on both the liq- uid and vapor sweat connections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer­tification program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
Page 2
036-21020-003 Rev. C (0203)
Physical and Electrical Data
MODEL
Unit Supply Voltage 208/230 – 1 – 60
Normal Voltage Range Minimum Circuit Ampacity
Max. Overcurrent Device Amps
Compressor Type
Compressor Amps
Crankcase Heater Fan Motor Amps Rated Load Fan Diameter Inches
Fan Motor
Face Area Sq. Ft.
Coil
Rows Deep
Fin / Inches Liquid Line OD Vapor Line OD
Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz. Operating Weight Lbs.
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker.
3. All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot valve.
1
3
Rated Load Locked Rotor
Rated HP Nominal RPM Nominal CFM
4
H4DH018S06 H4DH024S06 H4DH030S06 H4DH036S06 H4DH042S06 H4DH048S06 H4DH060S06
187 to 252
10.1 12.1 18.5 22.0 25.2 31.6 37.4
2
15 20 30 35 40 50 55
Recip Inertia Scroll
7.7 9.3 14.1 16.6 19.2 24.3 28.8
48 57 78 98 105 150 169
NoYesNoNoNoNoNo
0.50.50.91.21.21.21.4
18 18 18 24 24 24 24
1/12 1/12 1/8 1/4 1/4 1/4 1/3
1100 1100 1075 850 850 850 1100
1500 1500 2050 3100 3100 3100 4100
14.1 14.1 14.1 20 20 24 24
1111111
20 20 20 18 18 20 20
3/83/83/83/83/83/83/8
5/83/43/43/47/87/87/8
4 - 14 5 - 1 5 - 4 5 - 15 6 - 12 8 - 10 7 - 13
0.68 0.68 0.68 0.68 0.70 0.70 0.70
144 154 148 225 230 235 243
B
Scroll
B
Scroll
B
Scroll
B
Scroll
C
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
48" OVERHEAD CLEARANCE
C
B
UNIT
MODEL
HDH
DIMENSIONS
(INCHES)
REFRIGERANT
CONNECTION
LINE SIZE
A B C Liquid Vapor
018 30-1/8 24 24
5/8
024 30-1/8 24 24
AIR IN 4 SIDES
A
036 31-7/8 35 35
3/8
3/4030 30-1/8 24 24
042 31-7/8 35 35
7/8048 37-7/8 35 35
060 37-7/8 35 35
VAPOR CONNECTION
LIQUID CONNECTION
3-1/8
5-1/2
2-3/8
2 Unitary Products Group
Page 3
036-21020-003 Rev. C (0203)
Additional R-22 Charge / Orifice Size for Various Matched Systems
ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS
Outdoor Unit Unit Orifice (s)
1
Factory R-22 Charge, lbs-oz
Indoor Coil G2FD024(S,H)14,17
G2FD030(S,H)17
G2FD035(S,H)14 G2FD036(S,H)17,21 G2FD042(S,H)21 G2FD046(S,H)17 G2FD048(S,H)21,24 G2FD060(S,H)24 G2FD061(H)24 G1HD024 G1HD036 G1HD048 G1HD060 G1UA024S14,17 GIFA024S14,17 G1UA030S14 GIFA030S14 G1UA036S14,17,21 GIFA036S14,17,21 G1UA048S17 GIFA048S17 G1UA048S21 GIFA048S21 G1UA060S21,24 GIFA060S21,24 G1NA030S17H G1NA030S17K G1NA036S17J G1NA048S21D F2RC/F2FC024 F2RC/F2FC030 F2RC/F2FC036 F2RP/F2FP018 F2RP/F2FP024 F2RP/F2FP030 F2RP/F2FP036 F2FP040 F2RP/F2FP042 F2FP045 F2RP/F2FP048 F2RP/F2FP060 F2FV060
Footnotes:
1. These orifices are packed in the customer packet of each outdoor unit.
2. These orifices are factory mounted in the flow control device of each indoor coil.
3. A TXV Kit must be used with these units to obtain system performance (701,702,703 indicates 1TV07
Coil Orifice
61 57 + 6 63 + 2
65 57 + 8 63 + 4
65 57 + 8 63 + 4 69 + 3 75 + 0
75 63 + 8 69 + 3 75 + 10
78 75 + 13 75 + 5
78 71 + 6 75 + 13 75 + 5 87+ 0
84 71 + 7 75 + 24/7023 + 24 75 + 20 87 + 8
90 78 + 15 90 + 10/7033 + 10 99 + 13/7033 + 13
90 90 + 21 7033 + 5
59 55 + 7 63 + 3
69 63 + 10 69 + 3 75 + 18
84 78 + 22 75 + 14 87 + 1
96 90 + 5 99 + 9
59 57 + 4 61 + 0
59 57 + 4 61 + 0
65 57 + 6 63 + 2 7013 + 0——— —
65 57 + 6 63 + 2 7013 + 0——— —
73 55 + 8 63 + 2 69 + 3 75 + 0
73 55 + 8 63 + 2 69 + 3 75 + 0
84 71 + 6 78 + 20 75 + 15 87 + 7
84 71 + 6 78 + 20 75 + 15 87 + 7
84 71 + 6 78 + 20/7023 + 20 75 + 19 87 + 7
84 71 + 6 78 + 20/7023 + 20 75 + 19 87 + 7
90 78 + 16 90 + 10/7033 + 15 99 + 9
90 78 + 16 90 + 10/7033 + 15 99 + 9
5757 + 6—— ——— —
63 65 + 6 69 + 0
67 75 + 6
78 7023 + 15 75 + 12 87 + 3
61 55 + 4 63 + 0
65 63 + 4 69 + 0
73 73 + 3 78 + 12
5955 + 0—— ——— —
61 55 + 6 61 + 0
65 63 + 4 69 + 0/7013 + 0——— —
75 71 + 3 78 + 12
63 7013 + 14 71 + 6
78 78 + 14 75 + 8
78 7023 + 28 78 + 20
84 78 + 23 75 + 16 87 + 7
90 90 + 10 99 + 13/7033 + 13
90 90 + 10 7033 + 0
Procedures:
1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of interconnecting line tubing.
2.Verify the orifice size and additional charge required for specific evaporator coil in the system using the above table.
3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.
5.If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice size.
6.Due to serial compressor, hard start components are not required when using coils with TXV or solenoid valve kits.
H4DH018S06 H4DH024S06 H4DH030S06 H4DH036S06 H4DH042S06 H4DH048S06 H4DH060S06
55, 57 61, 63 69, 71 75, 78 75, 78 87, 90 99
4 - 14 5 - 1 5 - 4 5 - 15 6 - 12 8 - 10 7 - 13
2
System Orifice = Additional Charge, Oz
69 + 0
701
3
+ 0
——— —
Series).
---
Unitary Products Group 3
Page 4
036-21020-003 Rev. C (0203)
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
MODEL
AIR HANDLER
ELECTRIC
HEAT KW
2
W
COIL
MODEL
1
RATED
CFM
NET MBH
TOTAL SENS.
1 PH 12 SEER AC / N1AH + G2FD
H4DH018S06
H4DH024S06
H4DH030S06
N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 650 18.6 14.0 12.50 - 10.80 N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 650 19.0 14.3 12.50 - 10.80 N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 850 23.4 17.6 12.10 - 10.90 N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 850 23.4 17.6 12.00 - 10.90 N1AHB1206 5,8,10,15,19 17 G2FD030(S,H)17 1030 29.4 22.1 - 12.40 10.50 N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1030 30.0 22.5 12.40 - 10.60 N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1200 35.8 26.5 12.15 - 11.20
H4DH036S06
N1AHB1206 5,8,10,15,19 17 G2FD046(S,H)17 1200 36.2 26.8 12.30 - 11.20 N1AHD1406 5,8,10,15,19 24 G2FD048(S,H)24 1200 38.0 28.1 13.50 - 12.05 N1AHD1406 5,8,10,15,19 24 G2FD060(S,H)24 1200 38.5 28.5 13.70 - 12.20
H4DH042S06
H4DH048S06
H4DH060S06
N1AHC1606 5,8,10,15,20 21 G2FD042(S,H)21 1400 40.5 30.4 12.00 - 10.60 N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1400 42.0 31.5 12.35 - 10.90 N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1600 48.5 36.4 12.35 - 11.15 N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1600 50.0 37.5 12.50 13.00 11.45 N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1800 58.5 43.9 12.00 12.50 11.05 N1AHD2006 8,10,15,20,25,30 24 G2FD061H24 2000 60.0 45.0 12.50 12.50 11.25
1 PH 12 SEER AC / N1VS - VARIABLE SPEED
H4DH018S06 N1VSB12 10,15,18 17 G2FD024(S,H)17 650 20.0 15.0 - 13.50 11.20
H4DH024S06
H4DH030S06
H4DH036S06
N1VSB12 10,15,18 17 G2FD024(S,H)17 850 24.4 18.3 13.50 - 12.10 N1VSB12 10,15,18 17 G2FD036(S,H)17 860 24.6 18.5 13.55 - 12.10 N1VSB12 10,15,18 17 G2FD036(S,H)17 1030 31.0 23.3 13.40 - 11.30 N1VSB12 10,15,18 17 G2FD046(S,H)17 1000 32.6 22.8 13.50 - 11.50 N1VSB12 10,15,18 17 G2FD036(S,H)17 1200 35.6 26.7 13.10 - 12.05 N1VSC16 10,15,18 21 G2FD048(S,H)21 1200 38.0 28.5 14.10 - 12.55
H4DH042S06 N1VSC16 10,15,18 21 G2FD048(S,H)21 1380 42.5 31.9 13.35 - 11.70
H4DH048S06
H4DH060S06
N1VSC16 10,15,18 21 G2FD048(S,H)21 1590 49.0 36.8 13.00 - 11.70 N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1600 50.5 37.9 13.10 - 11.90 N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1780 59.0 44.3 12.40 - 11.40 N1VSD20 10,15,18,30 24 G2FD061H24 1780 60.5 45.4 - 13.00 11.80
1 PH 12 SEER AC / F2RP / RC / FP / FC / FV
4,5
F2RC/FC024 5,8,10 18 - 650 18.6 14.0 12.20 - 10.90
H4DH018S06
F2RP/FP018 2,5,8 18 - 650 18.0 13.5 12.00 - 10.70 F2RP/FP024 5,8,10 18 - 650 18.6 14.0 12.50 - 11.00 F2RC/FC024 5,8,10 18 - 850 23.0 17.3 12.00 - 10.80 F2RC/FC030 5,8,10,15 18 - 850 23.4 17.6 12.00 - 10.90
H4DH024S06
F2RP/FP024 5,8,10 18 - 850 24.0 18.0 12.10 - 10.90 F2RP/FP030 5,8,10,15 18 - 850 24.4 18.3 12.00 - 10.80
F2FP040 5,8,10,15 21 - 850 24.8 18.6 - 12.70 11.30
F2RC/FC030 5,8,10,15 18 - 1030 28.4 21.3 12.00 - 10.50
H4DH030S06
F2RP/FP030 5,8,10,15 18 - 1030 30.0 22.5 12.30 12.50 10.50 F2RP/FP036 5,8,10,15,19 21 - 1030 31.0 23.3 12.50 - 10.60
F2FP048 5,8,10,15,20,25 24 - 1030 31.4 23.6 12.60 - 10.70 F2RC/FC036 5,8,10,15 21 - 1200 35.6 26.7 12.35 - 11.10 F2RP/FP036 5,8,10,15,19 21 - 1200 36.2 27.2 12.50 - 11.45
H4DH036S06
F2RP/FP042 5,8,10,15 21 - 1200 36.4 27.3 12.50 - 11.50
F2FP045 5,8,10,15 24 - 1200 38.0 28.5 - 13.50 12.20
F2FP048 5,8,10,15,20,25 24 - 1200 36.8 27.6 12.80 - 11.80 F2RP/FP042 5,8,10,15 21 - 1400 40.5 30.4 12.00 - 10.50
H4DH042S06
F2FP045 5,8,10,15 24 - 1400 42.5 31.9 13.00 - 11.20
F2FP048 5,8,10,15,20,25 24 - 1400 41.5 31.1 12.20 - 10.65
F2FP048 5,8,10,15,20,25 24 - 1600 48.0 36.0 12.00 - 11.00
H4DH048S06
F2FP060 5,8,10,15,20,25 24 - 1600 49.0 36.8 12.30 - 10.95
F2FV060 8,10,15,20,25 24 - 1600 50.5 37.9 13.10 - 11.90
H4DH060S06
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
- = Not applicable
F2FP060 5,8,10,15,20,25 24 - 1900 59.0 44.3 12.00 - 10.90
F2FV060 8,10,15,20,25 24 - 1780 59.0 44.3 - 12.40 11.40
COOLING
SEER
W/O TXV
SEER
+ TXV
EER
3
4 Unitary Products Group
Page 5
036-21020-003 Rev. C (0203)
COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils
UNIT MODEL
H4DH018S06
H4DH024S06
H4DH030S06
H4DH036S06
For Notes see Page 5.
FURNACE**
CFM RANGE
(MIN.-MAX.)
575 725
750 950
900
1150
1050 1350
W
14,17 G1FA024S14,17 650 18.2 13.7 12.20 - 10.60
14 G1FA030S14 650 18.8 14.1 12.50 - 10.70 14 G1FA036S14 650 19.2 14.4 12.60 - 10.80
17,21 G1FA036S17,21 650 19.4 14.6 12.60 - 10.80
- G1HD024 650 18.6 14.0 12.00 - 10.60
17 G1NA030S17H 650 18.8 14.1 12.70 - 12.10
14,17 G1UA024S14,17 650 18.2 13.7 12.20 - 10.60
14 G1UA030S14 650 18.8 14.1 12.50 - 10.70
14 G1UA036S14 650 19.2 14.4 12.60 - 10.80 17,21 G1UA036S17,21 650 19.4 14.6 12.60 - 10.80 14,17 G2FD024(S,H)14,17 650 18.6 14.0 12.50 - 10.80
17 G2FD030(S,H)17 650 19.0 14.3 12.50 - 10.80
14 G2FD035(S,H)14 650 19.2 14.4 12.60 - 10.90 14,17 G1FA024S14,17 850 23.4 17.6 12.00 - 10.80
14 G1FA030S14 850 23.4 17.6 12.10 - 10.90
14 G1FA036S14 850 24.0 18.0 12.00 - 10.80 17,21 G1FA036S17,21 850 24.0 18.0 12.00 - 10.90
- G1HD024 850 23.4 17.6 12.00 - 10.70
- G1HD036 850 24.0 18.0 12.10 - 10.90
17 G1NA030S17H 850 24.0 18.0 12.40 - 11.10 14,17 G1UA024S14,17 850 23.4 17.6 12.00 - 10.80
14 G1UA030S14 850 23.4 17.6 12.10 - 10.90
14 G1UA036S14 850 24.0 18.0 12.00 - 10.80 17,21 G1UA036S17,21 850 24.0 18.0 12.00 - 10.90 14,17 G2FD024(S,H)14,17 850 23.4 17.6 12.10 - 10.90
17 G2FD030(S,H)17 850 23.4 17.6 12.00 - 10.90
14 G2FD035(S,H)14 850 23.4 17.6 12.00 - 10.80
17 G2FD036(S,H)17 850 24.0 18.0 - 12.10 10.90
14 G1FA030S14 1030 29.0 21.8 - 12.00 10.30 17,21 G1FA036S17,21 1030 30.4 22.8 12.10 - 10.40
17 G1FA048S17 1030 31.4 23.6 12.60 - 10.70 21,24 G1FA048S21 1030 31.4 23.6 12.60 - 10.70
- G1HD036 1030 30.0 22.5 12.20 - 10.50 17 G1NA030S17K 1030 29.4 22.1 12.00 - 10.50 14 G1UA030S14 1030 29.0 21.8 - 12.00 10.30
17,21 G1UA036S17,21 1030 30.4 22.8 12.10 - 10.40
17 G1UA048S17 1030 31.4 23.6 12.60 - 10.70
21,24 G1UA048S21 1030 31.4 23.6 12.60 - 10.70
17 G2FD030(S,H)17 1030 29.4 22.1 - 12.40 10.50 14 G2FD035(S,H)14 1030 30.0 22.5 12.10 - 10.40 17 G2FD036(S,H)17 1030 30.0 22.5 12.40 - 10.60 21 G2FD036(S,H)21 1030 30.0 22.5 12.50 - 10.60
21,24 G2FD048(S,H)21,24 1030 31.0 23.3 12.60 - 10.60 17,21 G1FA036S17,21 1200 35.2 26.0 12.00* - 11.00
17 G1FA048S17 1200 37.2 27.5 12.70 13.00* 11.45
21,24 G1FA048S21 1200 37.2 27.5 12.70 13.00* 11.50
- G1HD036 1200 35.2 26.0 12.00 - 10.95
- G1HD048 1200 37.8 28.0 12.50 - 11.15 17 G1NA036S17J 1200 35.4 26.2 12.20 - 11.15 21 G1NA048S21D 1200 37.0 27.4 - 12.90* 11.40
17,21 G1UA036S17,21 1200 35.2 26.0 12.00* - 11.00
17 G1UA048S17 1200 37.2 27.5 12.70 13.00* 11.45
21,24 G1UA048S21 1200 37.2 27.5 12.70 13.00* 11.50
14 G2FD035(S,H)14 1200 35.2 26.0 12.00* - 11.05 17 G2FD036(S,H)17 1200 35.8 26.5 12.15 - 11.20 21 G2FD036(S,H)21 1200 36.4 26.9 12.25 - 11.30 21 G2FD042(S,H)21 1200 36.2 26.8 12.30 - 11.20 17 G2FD046(S,H)17 1200 36.2 26.8 12.30 - 11.20
21,24 G2FD048(S,H)21,24 1200 37.8 28.0 12.80 13.00* 11.70
COIL
MODEL
RATED
CFM
NET MBH
TOTAL SENS.
*
COOLING
SEER
W/O TXV
SEER
+ TXV
EER
1
Unitary Products Group 5
Page 6
036-21020-003 Rev. C (0203)
COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils* (Continued)
UNIT MODEL
FURNACE**
CFM RANGE
(MIN.-MAX.)
W
COIL
MODEL
17 G1FA048S17 1400 41.0 30.8 12.15 - 10.70 21,24 G1FA048S21 1400 41.5 31.1 12.30 - 10.80 21,24 G1FA060S21,24 1400 42.5 31.9 12.45 - 11.10
- G1HD048 1400 41.0 30.8 12.25 - 10.75
21 G1NA048S21D 1400 40.5 30.4 12.15 - 10.70
H4DH042S06
1225 1575
17 G1UA048S17 1400 41.0 30.8 12.15 - 10.70 21,24 G1UA048S21 1400 41.5 31.1 12.30 - 10.80 21,24 G1UA060S21,24 1400 42.5 31.9 12.45 - 11.10
21 G2FD042(S,H)21 1400 40.5 30.4 12.00 - 10.60
17 G2FD046(S,H)17 1400 41.0 30.8 12.10 - 10.70 21,24 G2FD048(S,H)21,24 1400 42.0 31.5 12.35 - 10.90
24 G2FD060(S,H)24 1400 42.5 31.9 12.45 - 11.10
17 G1FA048S17 1600 48.0 36.0 12.20* - 11.00 21,24 G1FA048S21 1600 48.0 36.0 12.20* - 11.00 21,24 G1FA060S21,24 1600 49.5 37.1 12.50* 13.00* 11.35
- G1HD048 1600 49.0 36.8 12.00 - 11.10
- G1HD060 1600 49.5 37.1 12.20* - 11.35
H4DH048S06
1400 1800
21 G1NA048S21D 1600 47.0 35.3 12.00 - 10.85
17 G1UA048S17 1600 48.0 36.0 12.20* - 11.00 21,24 G1UA048S21 1600 48.0 36.0 12.20* - 11.00 21,24 G1UA060S21,24 1600 49.5 37.1 12.50* 13.00* 11.35
17 G2FD046(S,H)17 1500 47.0 35.3 12.00 - 10.75 21,24 G2FD048(S,H)21,24 1600 48.5 36.4 12.35* - 11.15
24 G2FD060(S,H)24 1600 50.0 37.5 12.50* 13.00* 11.45 21,24 G1FA060S21,24 1800 58.5 43.9 12.00 - 11.05
- G1HD060 2000 59.0 44.3 12.00 - 11.10
21,24 G1UA060S21,24 1800 58.5 43.9 12.00 - 11.05
24 G2FD060(S,H)24 1800 58.5 43.9 12.00 12.50 11.05
H4DH060S06
1575 2025
24 G2FD061H24 2000 60.0 45.0 12.00 12.50 11.25
1. TXV = Use 1TV700 Series Kit. * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up.
RATED
CFM
NET MBH
TOTAL SENS.
COOLING
SEER
W/O TXV
SEER
+ TXV
EER
1
6 Unitary Products Group
Page 7
COOLING CAPACITY - With Variable Speed Furnaces
UNIT MODEL
H4DH018S06
H4DH024S06
H4DH030S06
VARIABLE SPEED FURNACE MODEL
COIL MODEL
1 PH 12 SEER AC / P1DU / P1XD / P1XU - VARIABLE SPEED
P1DUA12V G1FA024S14 14 645 18.8 14.1 14.00 - 12.05 P1DUA12V G1FA030S14 14 645 19.4 14.6 14.00 - 12.15 P1DUA12V G1FA036S14 14 645 19.6 14.7 14.00 - 12.20 P1DUA12V G1HD024 - 645 19.2 14.4 14.00 - 12.05 P1DUA12V G1UA024S14 14 645 18.8 14.1 14.00 - 12.05 P1DUA12V G1UA030S14 14 645 19.4 14.6 14.00 - 12.15 P1DUA12V G1UA036S14 14 645 19.6 14.7 14.00 - 12.20 P1DUA12V G2FD024(S,H)14 14 645 19.2 14.4 14.00 - 12.30
P1XDB12V G2FD024(S,H)17 17 620 19.0 14.3 13.00 - 12.00 P1XUB12V G1FA024S17 17 645 18.8 14.1 14.00 - 12.05 P1XUB12V G1FA036S17 17 645 20.0 15.0 14.00 - 12.20 P1XUB12V G1UA024S17 17 645 18.8 14.1 14.00 - 12.05 P1XUB12V G1UA036S17 17 645 20.0 15.0 14.00 - 12.20 P1XUB12V G2FD024(S,H)17 17 645 19.2 14.4 14.00 - 12.30
P1XUB12V G2FD030(S,H)17 17 645 19.6 14.7 14.00 - 12.25 P1DUA12V G1FA024S14 14 820 24.0 18.0 13.00 - 11.95 P1DUA12V G1FA030S14 14 820 24.0 18.0 13.00 - 12.05 P1DUA12V G1FA036S14 14 820 24.6 18.5 13.00 - 12.00 P1DUA12V G1HD024 - 820 24.0 18.0 13.00 - 11.80 P1DUA12V G1HD036 - 820 24.6 18.5 13.00 - 12.00 P1DUA12V G1UA024S14 14 820 24.0 18.0 13.00 - 11.95 P1DUA12V G1UA030S14 14 820 24.0 18.0 13.00 - 12.05 P1DUA12V G1UA036S14 14 820 24.6 18.5 13.00 - 12.00 P1DUA12V G2FD024(S,H)14 14 820 24.0 18.0 13.00 - 12.00
P1XDB12V G2FD024(S,H)17 17 815 23.8 17.9 13.00 - 11.80
P1XUB12V G1FA024S17 17 820 24.0 18.0 13.00 - 11.95
P1XUB12V G1FA036S17 17 820 24.6 18.5 13.00 - 12.00
P1XUB12V G1UA024S17 17 820 24.0 18.0 13.00 - 11.95
P1XUB12V G1UA036S17 17 820 24.6 18.5 13.00 - 12.00
P1XUB12V G2FD024(S,H)17 17 820 24.0 18.0 13.00 - 12.05
P1XUB12V G2FD030(S,H)17 17 820 24.6 18.5 13.00 - 12.00
P1XUB12V G2FD036(S,H)17 17 820 24.6 18.5 13.00 - 12.00 P1DUA12V G1FA030S14 14 1035 29.4 22.1 12.50 - 10.95 P1DUA12V G1FA036S14 14 1035 30.8 23.1 12.50 - 11.05 P1DUA12V G1HD036 - 1035 30.4 22.8 13.00 - 11.15 P1DUA12V G1UA030S14 14 1035 29.4 22.1 12.50 - 10.95 P1DUA12V G1UA036S14 14 1035 30.8 23.1 12.50 - 11.05 P1DUB16V G1FA036S17 17 1050 31.0 23.3 13.20 - 11.30 P1DUB16V G1FA048S17 17 1065 32.2 24.2 14.00 - 11.90 P1DUB16V G1HD036 - 1065 30.8 23.1 13.50 - 11.70 P1DUB16V G1UA036S17 17 1050 31.0 23.3 13.20 - 11.30 P1DUB16V G1UA048S17 17 1065 32.2 24.2 14.00 - 11.90 P1DUB16V G2FD030(S,H)17 17 1050 31.0 23.3 13.20 - 11.30 P1DUB16V G2FD036(S,H)17 17 1065 30.8 23.1 13.50 - 11.85
P1XDB12V G2FD036(S,H)17 17 1050 29.6 22.2 13.00 - 11.05
P1XUB12V G1FA036S17 17 1035 31.0 23.3 13.00 - 11.35
P1XUB12V G1FA048S17 17 1035 32.2 24.2 13.50 - 11.65
P1XUB12V G1UA036S17 17 1035 31.0 23.3 13.00 - 11.35
P1XUB12V G1UA048S17 17 1035 32.2 24.2 13.50 - 11.65
P1XUB12V G2FD030(S,H)17 17 1020 30.8 23.1 12.90 - 11.05
P1XUB12V G2FD036(S,H)17 17 1035 30.6 23.0 13.50 - 11.60 P1XUC16V G1FA036S21 21 1065 31.0 23.3 13.00 - 11.35 P1XUC16V G1FA048S21 21 1065 32.2 24.2 13.50 - 11.65 P1XUC16V G1UA036S21 21 1065 31.0 23.3 13.00 - 11.35 P1XUC16V G1UA048S21 21 1065 32.2 24.2 13.50 - 11.65 P1XUC16V G2FD036(S,H)21 21 1065 30.0 22.5 13.50 - 11.50 P1XUC16V G2FD048(S,H)21 21 1065 31.6 23.7 13.50 - 11.55
1
W
RATED
CFM
NET MBH
TOTAL SENS.
036-21020-003 Rev. C (0203)
COOLING
SEER
W/O TXV
3
SEER
+ TXV
2
EER
Unitary Products Group 7
Page 8
036-21020-003 Rev. C (0203)
COOLING CAPACITY - With Variable Speed Furnaces (Continued)
UNIT MODEL
For Notes see Page 8.
H4DH036S06
H4DH042S06
For Notes see Page 8.
VARIABLE SPEED
FURNACE MODEL
COIL MODEL
P1DUB16V G1FA036S17 17 1220 35.8 26.5 13.00 - 11.80 P1DUB16V G1FA048S17 17 1220 38.0 28.1 13.50 - 12.40 P1DUB16V G1HD036 - 1220 35.8 26.5 13.00 - 11.65 P1DUB16V G1HD048 - 1220 38.5 28.5 13.50 - 11.85 P1DUB16V G1UA036S17 17 1220 35.8 26.5 13.00 - 11.80 P1DUB16V G1UA048S17 17 1220 38.0 28.1 13.50 - 12.40 P1DUB16V G2FD036(S,H)17 17 1220 36.4 26.9 13.00 - 12.00 P1DUB16V G2FD046(S,H)17 17 1220 36.8 27.2 13.00 - 12.00 P1DUC20V G1FA036S21 21 1220 35.8 26.5 13.00 - 11.80 P1DUC20V G1FA048S21 21 1200 38.0 28.1 14.00 - 12.65 P1DUC20V G1HD036 - 1200 36.0 26.6 13.50 - 12.15 P1DUC20V G1HD048 - 1200 39.0 28.9 14.00 - 12.30 P1DUC20V G1UA036S21 21 1220 35.8 26.5 13.00 - 11.80 P1DUC20V G1UA048S21 21 1200 38.0 28.1 14.00 - 12.65 P1DUC20V G2FD036(S,H)21 21 1200 36.6 27.1 13.50 - 12.50 P1DUC20V G2FD042(S,H)21 21 1200 36.8 27.2 13.40 - 12.10 P1DUC20V G2FD048(S,H)21 21 1200 38.5 28.5 14.00 - 12.70 P1XDB12V G2FD036(S,H)17 17 1250 36.0 26.6 12.50 - 11.55 P1XUB12V G1FA036S17 17 1220 35.4 26.2 12.40 - 11.35 P1XUB12V G1FA048S17 17 1230 38.0 28.1 13.50 - 12.45 P1XUB12V G1UA036S17 17 1220 35.4 26.2 12.40 - 11.35 P1XUB12V G1UA048S17 17 1230 38.0 28.1 13.50 - 12.45 P1XUB12V G2FD036(S,H)17 17 1200 36.0 26.6 12.60 - 11.55 P1XUB12V G2FD046(S,H)17 17 1230 36.8 27.2 13.00 - 12.00 P1XUC20V G1FA036S21 21 1200 35.8 26.5 13.00 - 11.75 P1XUC20V G1FA048S21 21 1200 38.0 28.1 13.90 - 12.60 P1XUC20V G1UA036S21 21 1200 35.8 26.5 13.00 - 11.75 P1XUC20V G1UA048S21 21 1200 38.0 28.1 13.90 - 12.60 P1XUC20V G2FD036(S,H)21 21 1200 36.6 27.1 13.50 - 12.50 P1XUC20V G2FD042(S,H)21 21 1200 37.0 27.4 13.50 - 12.45 P1XUC20V G2FD048(S,H)21 21 1200 38.5 28.5 13.90 - 12.65 P1DUB16V G1FA048S17 17 1400 41.0 30.8 12.50 - 10.95 P1DUB16V G1HD048 - 1425 41.5 31.1 13.00 - 11.45 P1DUB16V G1UA048S17 17 1400 41.0 30.8 12.50 - 10.95 P1DUB16V G2FD046(S,H)17 17 1400 41.5 31.1 12.90 - 11.20 P1DUC20V G1FA048S21 21 1420 42.5 31.9 13.00 - 11.60 P1DUC20V G1FA060S21 21 1460 43.0 32.3 13.00 - 11.55 P1DUC20V G1HD048 - 1400 41.5 31.1 12.75 - 11.15 P1DUC20V G1UA048S21 21 1420 42.5 31.9 13.00 - 11.60 P1DUC20V G1UA060S21 21 1460 43.0 32.3 13.00 - 11.55 P1DUC20V G2FD042(S,H)21 21 1460 43.0 32.3 13.00 - 11.55 P1DUC20V G2FD048(S,H)21 21 1420 42.5 31.9 13.00 - 11.70 P1XDD20V G2FD048(S,H)24 24 1365 42.0 31.5 13.00 - 11.40 P1XUC16V G1FA048S21 21 1425 42.0 31.5 13.00 - 11.50 P1XUC16V G1FA060S21 21 1425 43.0 32.3 13.00 - 11.80 P1XUC16V G1UA048S21 21 1425 42.0 31.5 13.00 - 11.50 P1XUC16V G1UA060S21 21 1425 43.0 32.3 13.00 - 11.80 P1XUC16V G2FD042(S,H)21 21 1425 41.0 30.8 12.50 - 11.30 P1XUC16V G2FD048(S,H)21 21 1425 42.5 31.9 13.00 - 11.60 P1XUC20V G1FA048S21 21 1420 42.5 31.9 13.00 - 11.60 P1XUC20V G1FA060S21 21 1410 43.0 32.3 13.10 - 11.65 P1XUC20V G1UA048S21 21 1420 42.5 31.9 13.00 - 11.60 P1XUC20V G1UA060S21 21 1410 43.0 32.3 13.10 - 11.65 P1XUC20V G2FD042(S,H)21 21 1410 41.0 30.8 12.40 - 10.95 P1XUC20V G2FD048(S,H)21 21 1420 42.5 31.9 13.00 - 11.70
1
W
RATED
CFM
NET MBH
TOTAL SENS.
COOLING
SEER
W/O TXV
SEER
+ TXV
EER
2
8 Unitary Products Group
Page 9
COOLING CAPACITY - With Variable Speed Furnaces (Continued)
UNIT MODEL
VARIABLE SPEED FURNACE MODEL
COIL MODEL
P1DUB16V G1FA048S17 17 1500 48.5 36.4 13.00 - 11.85 P1DUB16V G1UA048S17 17 1500 48.5 36.4 13.00 - 11.85 P1DUC20V G1FA048S21 21 1610 48.0 36.0 12.45 - 11.20 P1DUC20V G1FA060S21 21 1610 49.5 37.1 13.30 - 11.60 P1DUC20V G1HD048 - 1610 49.0 36.8 12.25 - 11.35 P1DUC20V G1UA048S21 21 1610 48.0 36.0 12.45 - 11.20 P1DUC20V G1UA060S21 21 1610 49.5 37.1 13.30 - 11.60 P1DUC20V G2FD048(S,H)21 21 1610 48.5 36.4 12.50 - 11.35 P1XDD20V G2FD048(S,H)24 24 1605 49.5 37.1 13.00 - 12.00 P1XUC16V G1FA048S21 21 1480 48.0 36.0 12.30 - 11.25 P1XUC16V G1FA060S21 21 1480 49.5 37.1 13.25 - 11.70
H4DH048S06
P1XUC16V G1UA048S21 21 1480 48.0 36.0 12.30 - 11.25 P1XUC16V G1UA060S21 21 1480 49.5 37.1 13.25 - 11.70 P1XUC16V G2FD048(S,H)21 21 1480 48.5 36.4 12.50 - 11.40 P1XUC20V G1FA048S21 21 1450 48.0 36.0 12.50 - 11.45 P1XUC20V G1FA060S21 21 1590 49.5 37.1 13.25 - 11.55 P1XUC20V G1UA048S21 21 1450 48.0 36.0 12.50 - 11.45 P1XUC20V G1UA060S21 21 1590 49.5 37.1 13.25 - 11.55 P1XUC20V G2FD048(S,H)21 21 1450 48.5 36.4 13.00 - 11.65 P1XUD20V G1FA060S24 24 1620 49.5 37.1 13.25 - 11.55 P1XUD20V G1UA060S24 24 1620 49.5 37.1 13.25 - 11.55 P1XUD20V G2FD048(S,H)24 24 1620 48.5 36.4 12.50 - 11.25 P1XUD20V G2FD060(S,H)24 24 1620 50.0 37.5 12.70 - 11.60 P1DUC20V G1FA060S21 21 1800 59.0 44.3 12.00 - 11.20 P1DUC20V G1HD060 - 1730 59.0 44.3 12.10 - 11.50 P1DUC20V G1UA060S21 21 1800 59.0 44.3 12.00 - 11.20 P1XDD20V G2FD060(S,H)24 24 1675 58.5 43.9 12.00 - 11.05
H4DH060S06
P1XUC20V G1FA060S21 21 1860 59.0 44.3 12.00 - 11.20 P1XUC20V G1UA060S21 21 1860 59.0 44.3 12.00 - 11.20 P1XUD20V G1FA060S24 24 1860 59.0 44.3 12.00 - 11.20 P1XUD20V G1UA060S24 24 1860 59.0 44.3 12.00 - 11.20 P1XUD20V G2FD060(S,H)24 24 1860 59.0 44.3 12.00 - 11.20 P1XUD20V G2FD061H24 24 1800 60.0 45.0 12.60 - 11.50
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. TXV = Use 1TV700 Series Kit.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
1
W
RATED
CFM
NET MBH
TOTAL SENS.
036-21020-003 Rev. C (0203)
COOLING
SEER
W/O TXV
SEER
+ TXV
2
EER
Unitary Products Group 9
Page 10
036-21020-003 Rev. C (0203)
COOLING PERFORMANCE
SUCT. T/P
MODEL
H4DH018S06
H4DH024S06
H4DH030S06
H4DH036S06
1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15° superheat and 15° sub-cooling at condensing unit. a. Increase capacity 1% for each 2° increase in sub-cooling. b. Decrease capacity 1% for each 2° decrease in sub-cooling.
3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°. Maximum recommended
condensing temperature is 140°F.
@ COMPR.
TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW
35 61.5 18.7 1.92 12.6 2.06 7.3 2.24
40 68.5 20.8 1.92 14.3 2.10 8.8 2.31 40 68.5 40.5 3.11 35.7 3.77 30.9 4.49
45 76.0 22.9 1.90 16.1 2.11 10.2 2.37 45 76.0 44.4 3.15 39.4 3.85 34.4 4.61
50 84.0 25.1 1.86 18.0 2.11 11.8 2.41 50 84.0 48.4 3.19 43.2 3.91 37.9 4.72
35 61.5 22.4 2.10 17.4 2.30 12.7 2.51
40 68.5 25.0 2.14 19.6 2.36 14.6 2.58 40 68.5 52.5 3.69 44.4 4.54 36.8 5.57
45 76.0 27.7 2.17 21.9 2.41 16.6 2.65 45 76.0 57.3 3.73 48.7 4.57 40.6 5.62
50 84.0 30.4 2.20 24.3 2.45 18.6 2.72 50 84.0 62.3 3.77 53.2 4.61 44.6 5.67
35 61.5 26.6 2.52 22.9 3.00 19.3 3.62
40 68.5 29.1 2.54 25.1 3.03 21.3 3.65 40 68.5 60.6 4.41 56.2 5.43 51.4 6.74
45 76.0 31.6 2.56 27.5 3.05 23.4 3.68 45 76.0 65.6 4.46 61.0 5.47 56.1 6.80
50 84.0 34.3 2.58 29.9 3.08 25.6 3.71 50 84.0 70.9 4.50 66.0 5.52 60.8 6.85
35 61.5 34.3 2.62 30.9 3.10 27.4 3.77
40 68.5 37.7 2.64 34.1 3.13 30.3 3.80
45 76.0 41.4 2.66 37.5 3.17 33.4 3.85
50 84.0 45.1 2.69 41.0 3.21 36.7 3.90
AIR TEMP ON CONDENSER
75°F95°F115°F75°F95°F115°F
MODEL
SUCT. T/P
@ COMPR.
35 61.5 36.8 3.07 32.2 3.69 27.6 4.37
H4DH042S06
35 61.5 47.8 3.66 40.2 4.50 33.0 5.51
H4DH048S06
35 61.5 55.7 4.37 51.4 5.37 46.8 6.69
H4DH060S06
AIR TEMP ON CONDENSER
ACCESSORIES
Refer to Price Manual for specific model numbers.
Hard Start Kit - Provides increased starting torque for areas with low voltage.
Compressor Blanket - Designed to further reduce the nor­mal compressor operating sound. Refer to price pages for specific match-ups.
Off Cycle Timer Delay - Provides a 5-minute off cycle to pre­vent rapid recycling of the compressor.
Room Thermostats - A wide selection of compatible thermo­sets are available to provide optimum performance and fea­tures for any installation.
1 Heat Stage only, manual, mechanical thermostat. Add sub­base for 1H/1C.
1H/1C, manual change-over electronic non-programmable thermostat.
1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable.
* For the most current accessory information, refer to the price book or consult factory.
SOUND RATINGS
UNIT MODEL
018 70
024 72
030 72
036 74
042 76
048 76
060 76
*Rated in accordance with ARI Standard 270.
SOUND RATINGS
DECIBELS*
10 Unitary Products Group
Page 11
TYPICAL INSTALLATION
036-21020-003 Rev. C (0203)
THERMOSTAT
TO
POWER TO INDOOR
BLOWER
TO COIL
L INSTALLATION
NOTE: All outdoor wiring must be weatherproof
SUPPLY
NEC CLASS 2 WIRING
NEC CLASS 1 WIRING
Seal opening(s) with permagum or equivalent
TYPICAL FIELD WIRING - 1 PHASE APPLICATION
WEATHERPROOF DISCONNECT SWITCH
24SERVICE ACCESS CLEARANCE
48O VERHEAD CLEARANCE
12REAR AND SIDES
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES
POWER WIRING
GND.
LUG
208/230-1-60
CONTACTOR TERMINALS
COIL
CONDENSING UNIT
ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.
24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2)
*
TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.
FURNACE OR AIR HANDLER TERMINAL BLOCK
CYRGW
YRGW
ROOM THERMOSTAT
POWER WIRING CONTROL WIRING FACTORY WIRING
*
Unitary Products Group 11
Page 12
036-21020-003 Rev. C (0203)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. H4DH018S06
INDOOR COIL MODEL NO. G1FA024S14,17
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
NOTE:
ID CFM 600 650 700
ID DB 85 80 75 70 85 80 75 70 85 80 75 70
ID WB 72 67 62 57 72 67 62 57 72 67 62 57
T.C. 22.1 20.3 18.6 16.9 22.3 20.5 18.8 17.1 22.5 20.7 18.9 17.2
S.C. 13.2 13.3 13.4 13.4 13.6 13.6 13.8 13.8 13.9 14.0 14.2 14.2
K.W 1.61 1.63 1.64 1.63 1.62 1.65 1.66 1.66 1.64 1.67 1.68 1.68
T.C. 21.7 19.9 18.1 16.4 21.9 20.1 18.3 16.6 22.0 20.3 18.4 17.0
S.C. 13.5 13.5 13.6 13.6 13.9 14.0 14.1 14.1 14.4 14.4 14.6 14.9
K.W 1.65 1.67 1.68 1.67 1.67 1.69 1.70 1.69 1.68 1.71 1.72 1.71
T.C. 19.8 18.1 16.4 14.9 19.9 18.2 16.6 15.1 20.0 18.3 16.8 15.3
S.C. 13.2 13.2 13.3 13.3 13.7 13.7 14.0 13.8 14.2 14.2 14.4 14.3
K.W 1.75 1.78 1.78 1.77 1.77 1.80 1.80 1.80 1.78 1.81 1.82 1.82
T.C. 17.4 15.9 14.4 13.1 17.6 16.1 14.6 13.4 17.6 16.2 14.7 13.6
S.C. 12.7 12.6 12.7 12.7 13.2 13.2 13.2 12.9 13.8 13.8 13.7 13.1
K.W 1.90 1.92 1.92 1.90 1.92 1.94 1.94 1.93 1.93 1.96 1.96 1.95
T.C. 15.1 13.7 12.3 11.3 15.2 13.8 12.6 11.5 15.3 13.9 12.8 11.7
S.C. 11.9 11.8 11.8 10.9 12.5 12.3 12.2 11.1 13.0 12.9 12.3 11.3
K.W 2.08 2.09 2.08 2.05 2.10 2.11 2.10 2.08 2.12 2.13 2.12 2.10
T.C. 12.8 11.5 10.2 9.5 12.8 11.5 10.6 9.6 13.0 11.6 10.9 9.8
S.C. 11.1 11.0 10.9 9.1 11.8 11.4 11.2 9.3 12.2 12.0 10.9 9.5
K.W 2.26 2.26 2.24 2.20 2.28 2.28 2.26 2.23 2.31 2.30 2.28 2.25
Multipliers for determining the performance with other indoor sections.
Air Handler Coil
N1AHB08 G2FD024(S,H)17 1.02 1.02 1.00
N1AHB08 G2FD030(S,H)17 1.04 1.04 1.02
N1VSB12 G2FD024(S,H)17 1.10 1.10 0.94
F2RP/FP018 0.99 0.99 0.80
F2RC/FC024 1.02 1.02 0.99
F2RP/FP024 1.02 1.02 0.98
G1FA036S17,21 1.07 1.07 1.05
G2FD035(S,H)14 1.05 1.05 1.03
G1HD024 1.02 1.02 1.02
G1UA030S14 1.03 1.03 1.02
G1UA036S14 1.05 1.05 1.04
G1UA036S17,21 1.07 1.07 1.05
G2FD030(S,H)17 1.04 1.04 1.02
G2FD024(S,H)17 1.02 1.02 1.00
G1NA030S17H 1.03 1.03 0.99
G1UA024S14,17 1.00 1.00 1.00
G1FA030S14 1.03 1.03 1.02
G1FA036S14 1.05 1.05 1.04
T.C. S.C. KW
Variable Speed Furnace
P1DUA12V G1FA024S14 1.03 1.03 0.91
P1DUA12V G1FA030S14 1.07 1.07 0.93
P1DUA12V G1FA036S14 1.08 1.08 0.94
P1DUA12V G1HD024 1.05 1.05 0.93
P1DUA12V G1UA024S14 1.03 1.03 0.91
P1DUA12V G1UA030S14 1.07 1.07 0.93
P1DUA12V G1UA036S14 1.08 1.08 0.94
P1DUA12V G2FD024(S,H)14 1.05 1.05 0.91
P1XDB12V G2FD024(S,H)17 1.04 1.04 0.92
P1XUB12V G1FA024S17 1.03 1.03 0.91
P1XUB12V G1FA036S17 1.10 1.10 0.95
P1XUB12V G1UA024S17 1.03 1.03 0.91
P1XUB12V G1UA036S17 1.10 1.10 0.95
P1XUB12V G2FD024(S,H)17 1.05 1.05 0.91
P1XUB12V G2FD030(S,H)17 1.08 1.08 0.93
Coil
T.C. S.C. KW
12 Unitary Products Group
Page 13
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. H4DH024S06
INDOOR COIL MODEL NO. G1FA024S14,17
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
NOTE:
ID CFM 800 850 900
ID DB 85 80 75 70 85 80 75 70 85 80 75 70
ID WB 72 67 62 57 72 67 62 57 72 67 62 57
T.C. 27.8 25.4 23.2 21.1 27.9 25.6 23.4 21.4 28.1 25.8 23.5 21.6
S.C. 17.9 18.0 18.2 18.3 18.5 18.5 18.7 19.0 19.0 19.1 19.2 19.4
K.W 1.66 1.64 1.63 1.61 1.68 1.66 1.65 1.64 1.70 1.68 1.67 1.66
T.C. 26.6 24.4 22.2 20.3 26.8 24.6 22.4 20.5 26.9 24.7 22.5 20.7
S.C. 17.5 17.6 17.8 17.9 18.1 18.1 18.3 18.5 18.5 18.6 18.8 18.9
K.W 1.79 1.78 1.76 1.75 1.81 1.80 1.78 1.77 1.84 1.82 1.80 1.79
T.C. 25.4 23.3 21.1 19.4 25.5 23.4 21.3 19.6 25.7 23.5 21.5 19.7
S.C. 17.1 17.1 17.3 17.4 17.6 17.6 17.8 17.9 18.1 18.1 18.4 18.4
K.W 2.00 1.98 1.96 0.39 2.02 2.00 1.98 1.97 2.04 2.02 0.47 1.99
T.C. 24.1 22.1 20.1 18.4 24.2 22.2 20.2 18.6 24.4 22.3 20.5 18.7
S.C. 16.6 16.6 16.8 16.9 17.1 17.1 17.3 17.4 17.6 17.6 18.0 17.9
K.W 2.23 2.21 2.19 2.17 2.26 2.23 2.21 2.19 2.28 2.26 2.23 2.21
T.C. 22.8 20.9 19.0 17.4 22.9 21.0 19.2 17.5 23.0 21.1 19.4 17.7
S.C. 16.1 16.1 16.4 16.3 16.6 16.6 17.0 16.8 17.1 17.1 17.4 17.3
K.W 2.50 2.48 2.45 2.42 2.52 2.50 2.47 2.45 2.54 2.52 2.49 2.47
T.C. 21.5 19.7 17.9 16.4 21.6 19.8 18.2 16.4 21.6 19.9 18.3 16.7
S.C. 15.6 15.6 16.0 15.7 16.1 16.1 16.7 16.2 16.6 16.6 16.8 16.7
K.W 2.77 2.75 2.71 2.67 2.78 2.77 2.73 2.71 2.80 2.78 2.75 2.73
036-21020-003 Rev. C (0203)
Multipliers for determining the performance with other indoor sections.
Air Handler Coil
N1AHB08 G2FD024(S,H)17 1.00 1.00 0.99 N1AHB08 G2FD030(S,H)17 1.00 1.00 0.99 N1VSB12 G2FD024(S,H)17 1.04 1.04 0.93 N1VSB12 G2FD036(S,H)17 1.05 1.05 0.94 F2RC/FC024 0.98 0.98 0.98 F2FP/FP024 1.03 1.03 1.02 F2RC/FC030 1.00 1.00 0.99 F2RP/FP030 1.04 1.04 1.04 F2FP040 1.06 1.06 1.01
G1FA036S14 1.03 1.03 1.03 G1FA036S17,21 1.03 1.03 1.02 G1HD024 1.00 1.00 1.01 G1HD036 1.03 1.03 1.02 G1NA030S17 1.03 1.03 1.00 G1UA024S14,17 1.00 1.00 1.00 G2FD036(S,H)17 1.03 1.03 1.02 G1UA030S14 1.00 1.00 0.99 G1UA036S14 1.03 1.03 1.03 G1UA036S17,21 1.03 1.03 1.02 G2FD030(S,H)17 1.00 1.00 0.99 G2FD024(S,H)14,17 1.00 1.00 0.99 G2FD035(S,H)14 1.00 1.00 1.00 G1FA030S14 1.00 1.00 0.99
T.C. S.C. KW
Variable Speed Furnace
P1DUA12V G1FA024S14 1.03 1.03 0.93
P1DUA12V G1FA030S14 1.03 1.03 0.92
P1DUA12V G1FA036S14 1.05 1.05 0.95
P1DUA12V G1HD024 1.03 1.03 0.94
P1DUA12V G1HD036 1.05 1.05 0.95
P1DUA12V G1UA024S14 1.03 1.03 0.93
P1DUA12V G1UA030S14 1.03 1.03 0.92
P1DUA12V G1UA036S14 1.05 1.05 0.95
P1DUA12V G2FD024(S,H)14 1.03 1.03 0.92
P1XDB12V G2FD024(S,H)17 1.02 1.02 0.93
P1XUB12V G1FA024S17 1.03 1.03 0.93
P1XUB12V G1FA036S17 1.05 1.05 0.95
P1XUB12V G1UA024S17 1.03 1.03 0.93
P1XUB12V G1UA036S17 1.05 1.05 0.95
P1XUB12V G2FD024(S,H)17 1.03 1.03 0.92
P1XUB12V G2FD030(S,H)17 1.05 1.05 0.95
P1XUB12V G2FD036(S,H)17 1.05 1.05 0.95
Coil
T.C. S.C. KW
Unitary Products Group 13
Page 14
036-21020-003 Rev. C (0203)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. H4DH030S06
INDOOR COIL MODEL NO. G1FA036S17,21
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
NOTE:
ID CFM 980 1030 1080
ID DB 85 80 75 70 85 80 75 70 85 80 75 70
ID WB 72 67 62 57 72 67 62 57 72 67 62 57
T.C. 35.3 32.6 29.8 27.3 35.7 32.9 30.1 27.8 35.9 33.2 30.4 28.1
S.C. 22.6 22.7 23.1 23.1 23.7 23.8 24.1 24.5 24.7 24.8 25.2 25.5
K.W 2.35 2.32 2.30 2.28 2.39 2.37 2.35 2.33 2.43 2.40 2.38 2.37
T.C. 33.7 31.2 28.5 26.1 34.0 31.4 28.8 26.6 34.3 31.7 29.1 26.9
S.C. 22.0 22.2 22.4 22.6 23.1 23.2 23.5 23.8 24.1 24.3 24.6 24.8
K.W 2.62 2.59 2.55 2.52 2.67 2.63 2.60 2.57 2.70 2.67 2.64 2.61
T.C. 32.6 30.1 27.6 25.4 32.9 30.4 27.9 25.8 33.0 30.6 28.3 26.1
S.C. 21.6 21.7 22.0 22.4 22.7 22.8 23.1 23.4 23.7 23.8 24.5 24.4
K.W 2.90 2.85 2.81 2.78 2.94 2.90 2.86 2.82 2.98 2.94 2.90 2.86
T.C. 31.4 29.0 26.6 24.6 31.6 29.3 26.9 24.9 31.8 29.5 27.3 25.1
S.C. 21.1 21.3 21.6 21.9 22.2 22.4 22.7 23.0 23.3 23.5 24.0 23.8
K.W 3.18 3.13 3.09 3.06 3.22 3.18 3.14 3.10 3.26 3.22 3.18 3.14
T.C. 30.1 27.9 25.6 23.7 30.2 28.1 26.0 23.9 30.4 28.2 26.2 24.6
S.C. 20.8 20.8 21.2 21.4 21.7 21.9 22.5 22.4 22.9 22.9 23.4 23.8
K.W 3.47 3.44 3.41 3.38 3.52 3.49 3.46 3.43 3.56 3.53 3.50 3.47
T.C. 28.8 26.8 24.6 22.8 28.8 26.9 25.1 22.9 29.0 26.9 25.1 24.1
S.C. 20.5 20.3 20.8 20.9 21.2 21.4 22.3 21.8 22.5 22.3 22.8 23.8
K.W 3.76 3.75 3.73 3.70 3.82 3.80 3.78 3.76 3.86 3.84 3.82 3.80
Multipliers for determining the performance with other indoor sections.
Air Handler Coil
N1AHB12 G2FD030(S,H)17 0.97 0.97 0.96
N1AHB12 G2FD036(S,H)17 0.99 0.99 0.97
N1VSB12 G2FD036(S,H)17 1.02 1.02 0.98
N1VSB12 G2FD046(S,H)17 1.05 1.05 1.00
F2RC/FC030 0.93 0.93 0.93
F2RP/FP030 0.99 0.99 0.98
F2FP040 1.03 1.03 1.00
F2RP/FP036 1.02 1.02 1.00
G1HD036 0.99 0.99 0.98
G1NA030S17 0.97 0.97 0.96
G1UA030S14 0.95 0.95 0.96
G1UA036S17,21 1.00 1.00 1.00
G1FA048S21 1.03 1.04 1.00
G1UA048S17 1.03 1.03 1.00
G1UA048S21 1.03 1.03 1.00
G2FD030(S,H)17 0.97 0.97 0.96
G2FD035(S,H)14 0.99 0.99 0.99
G2FD036(S,H)17 0.99 0.99 0.97
G2FD036(S,H)21 0.99 0.99 0.97
G2FD048(S,H)21,24 1.02 1.02 1.00
G1FA030S14 0.95 0.95 0.96
G1FA048S17 1.03 1.03 1.00
T.C. S.C. KW
Variable Speed Furnace
P1DUB16V G1UA036S17 1.02 1.02 0.94
P1DUB16V G1UA048S17 1.06 1.06 0.93
P1DUB16V G2FD030(S,H)17 1.02 1.02 0.94
P1DUB16V G2FD036(S,H)17 1.01 1.01 0.89
P1XDB12V G2FD036(S,H)17 0.97 0.97 0.92
P1XUB12V G1FA036S17 1.02 1.02 0.93
P1XUB12V G1FA048S17 1.06 1.06 0.95
P1XUB12V G1UA036S17 1.02 1.02 0.93
P1XUB12V G1UA048S17 1.06 1.06 0.95
P1XUB12V G2FD030(S,H)17 1.01 1.01 0.95
P1XUB12V G2FD036(S,H)17 1.01 1.01 0.90
P1XUC16V G1FA036S21 1.02 1.02 0.93
P1XUC16V G1FA048S21 1.06 1.06 0.95
P1XUC16V G1UA036S21 1.02 1.02 0.93
P1XUC16V G1UA048S21 1.06 1.06 0.95
P1XUC16V G2FD036(S,H)21 0.99 0.99 0.89
P1DUA12V G1FA030S14 0.97 0.97 0.92
P1DUA12V G1FA036S14 1.01 1.01 0.95
P1DUA12V G1HD036 1.00 1.00 0.93
P1DUA12V G1UA030S14 0.97 0.97 0.92
P1DUA12V G1UA036S14 1.01 1.01 0.95
P1DUB16V G1FA036S17 1.02 1.02 0.94
P1DUB16V G1FA048S17 1.06 1.06 0.93
P1DUB16V G1HD036 1.01 1.01 0.90
P1XUC16V G2FD048(S,H)21 1.04 1.04 0.94
Coil
T.C. S.C. KW
14 Unitary Products Group
Page 15
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. H4DH036S06 INDOOR COIL MODEL NO. G1FA036S17,21
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
NOTE:
ID CFM 1100 1200 1300
ID DB 85 80 75 70 85 80 75 70 85 80 75 70
ID WB 72 67 62 57 72 67 62 57 72 67 62 57
T.C. 40.9 37.5 34.2 31.2 41.2 37.9 34.5 31.5 41.6 38.2 34.8 32.0
S.C. 26.1 26.2 26.6 26.7 27.0 27.1 27.6 27.7 28.1 28.2 28.6 28.9
K.W 2.69 2.66 2.63 2.61 2.74 2.71 2.68 2.66 2.77 2.74 2.71 2.69
T.C. 39.7 36.4 33.2 30.3 40.1 36.7 33.5 30.6 40.3 37.1 33.7 31.0
S.C. 25.6 25.8 26.1 26.2 26.7 26.7 27.1 27.2 27.5 27.7 28.0 28.4
K.W 2.91 2.87 2.84 2.81 2.96 2.92 2.88 2.86 2.99 2.95 2.92 2.89
T.C. 38.0 34.8 31.8 29.0 38.3 35.2 32.1 29.5 38.7 35.5 32.4 29.8
S.C. 25.0 25.1 25.5 25.6 26.0 26.0 26.4 26.8 27.0 27.0 27.4 27.6
K.W 3.20 3.15 3.11 3.08 3.25 3.20 3.16 3.13 3.29 3.24 3.20 3.17
T.C. 36.4 33.4 30.4 27.7 36.7 33.7 30.6 28.2 36.8 33.9 30.9 28.5
S.C. 24.5 24.5 24.8 24.8 25.5 25.5 25.7 26.0 26.3 26.5 26.8 27.0
K.W 3.54 3.49 3.44 3.40 3.59 3.54 3.49 3.45 3.63 3.58 3.53 3.49
T.C. 34.6 31.9 28.9 26.6 34.8 32.0 29.1 26.8 35.2 32.2 29.6 27.1
S.C. 23.8 24.0 24.1 24.5 24.7 24.8 25.1 25.3 25.8 25.7 26.4 26.1
K.W 3.95 3.89 3.84 3.80 4.00 3.94 3.88 3.85 4.03 3.98 3.92 3.88
T.C. 32.8 30.4 27.4 25.5 33.0 30.3 27.6 25.4 33.6 30.5 28.3 25.7
S.C. 23.1 23.5 23.4 24.2 23.9 24.1 24.5 24.6 25.3 24.9 26.0 25.2
K.W 4.36 4.29 4.24 4.20 4.41 4.34 4.27 4.25 4.43 4.38 4.31 4.27
036-21020-003 Rev. C (0203)
Multipliers for determining the performance with other indoor sections.
Air Handler Coil
N1AHB12 G2FD036(S,H)17 1.02 1.02 1.00
N1AHB12 G2FD046(S,H)17 1.03 1.03 1.01
N1AHD14 G2FD048(S,H)24 1.08 0.91 0.99
N1AHD14 G2FD060(S,H)24 1.09 0.93 0.99
N1VSB12 G2FD036(S,H)17 1.01 1.03 0.92
F2RP/FP036 1.03 1.04 0.99
N1VSC16 G3FD048S21 1.08 1.09 0.95
F2RP/FP042 1.03 1.05 0.99
F2FP045 1.08 1.09 0.97
F2FP048 1.05 1.06 0.97
F2RC/FC036 1.01 1.03 1.00
G1FA048S24 1.06 1.06 1.01
G1HD036 1.00 1.00 1.00
G1HD048 1.07 1.07 1.06
G1NA036S17J 1.01 1.01 0.99
G1NA048S21D 1.05 1.05 1.01
G1UA036S17,21 1.00 1.00 1.00
G1FA048S21 1.06 1.06 1.01
G1UA048S17 1.06 1.06 1.02
G1UA048S21 1.06 1.06 1.01
G2FD035(S,H)14 1.00 1.00 1.00
G2FD036(S,H)17 1.02 1.02 1.00
G2FD036(S,H)21 1.03 1.03 1.01
G2FD042(S,H)21 1.03 1.03 1.01
G2FD046(S,H)17 1.03 1.03 1.01
G2FD048(S,H)21,24 1.07 1.07 1.01
G1FA048S17 1.06 1.06 1.02
T.C. S.C. KW
Variable Speed Furnace
P1DUB16V G1FA036S17 1.02 1.02 0.95 P1DUB16V G1FA048S17 1.08 1.08 0.96 P1DUB16V G1HD036 1.02 1.02 0.96 P1DUB16V G1HD048 1.09 1.09 1.02 P1DUB16V G1UA036S17 1.02 1.02 0.95 P1DUB16V G1UA048S17 1.08 1.08 0.96 P1DUB16V G2FD036(S,H)17 1.03 1.03 0.95 P1DUB16V G2FD046(S,H)17 1.05 1.05 0.96 P1DUC20V G1FA036S21 1.02 1.02 0.95 P1DUC20V G1FA048S21 1.08 1.08 0.94 P1DUC20V G1HD036 1.02 1.02 0.93 P1DUC20V G1HD048 1.11 1.11 0.99 P1DUC20V G1UA036S21 1.02 1.02 0.95 P1DUC20V G1UA048S21 1.08 1.08 0.94 P1DUC20V G2FD036(S,H)21 1.04 1.04 0.92 P1DUC20V G2FD042(S,H)21 1.05 1.05 0.95 P1DUC20V G2FD048(S,H)21 1.09 1.09 0.95 P1XDB12V G2FD036(S,H)17 1.02 1.02 0.97 P1XUB12V G1FA036S17 1.01 1.01 0.97 P1XUB12V G1FA048S17 1.08 1.08 0.95 P1XUB12V G1UA036S17 1.01 1.01 0.97 P1XUB12V G1UA048S17 1.08 1.08 0.95 P1XUB12V G2FD036(S,H)17 1.02 1.02 0.97 P1XUB12V G2FD046(S,H)17 1.05 1.05 0.96 P1XUC20V G1FA036S21 1.02 1.02 0.95 P1XUC20V G1FA048S21 1.08 1.08 0.94 P1XUC20V G1UA036S21 1.02 1.02 0.95 P1XUC20V G1UA048S21 1.08 1.08 0.94 P1XUC20V G2FD036(S,H)21 1.04 1.04 0.92 P1XUC20V G2FD042(S,H)21 1.05 1.05 0.93
Coil
T.C. S.C. KW
Unitary Products Group 15
Page 16
036-21020-003 Rev. C (0203)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. H4DH042S06
INDOOR COIL MODEL NO. G1FA048S17
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
NOTE:
ID CFM 1300 1400 1500
ID DB 85 80 75 70 85 80 75 70 85 80 75 70
ID WB 72 67 62 57 72 67 62 57 72 67 62 57
T.C. 45.2 41.7 38.1 34.8 45.6 42.0 38.5 35.1 45.9 42.3 38.7 35.4
S.C. 28.5 28.7 29.0 29.1 29.3 29.4 29.8 29.6 30.0 30.1 30.5 30.4
K.W 3.11 3.08 3.04 2.99 3.16 3.12 3.08 3.04 3.20 3.16 3.13 3.08
T.C. 45.3 41.7 38.1 34.8 45.7 42.1 38.4 35.1 46.0 42.4 38.7 35.8
S.C. 29.7 29.8 30.2 30.3 30.6 30.8 31.2 31.0 31.5 31.7 32.1 32.6
K.W 3.43 3.38 3.33 3.28 3.48 3.43 3.38 3.32 3.52 3.47 3.42 3.38
T.C. 44.3 40.7 37.1 34.0 44.6 41.0 37.4 34.4 44.9 41.2 37.6 34.7
S.C. 30.3 30.4 30.8 31.1 31.4 31.5 31.7 31.9 32.3 32.4 32.9 32.8
K.W 3.84 3.78 3.71 3.64 3.89 3.83 3.76 3.69 3.94 3.88 3.81 3.74
T.C. 42.4 38.9 35.4 32.4 42.7 39.2 35.8 32.7 42.9 39.4 36.1 33.0
S.C. 30.0 30.1 30.4 30.5 31.2 31.2 31.7 31.3 32.3 32.4 32.7 32.3
K.W 4.29 4.21 4.12 4.03 4.33 4.25 4.17 4.08 4.38 4.30 4.22 4.13
T.C. 40.1 36.7 33.5 30.5 40.4 37.0 33.8 30.8 40.5 37.1 34.0 31.6
S.C. 29.3 29.2 29.6 29.5 30.4 30.4 30.7 30.3 31.5 31.5 31.8 31.5
K.W 4.74 4.64 4.53 4.42 4.79 4.69 4.58 4.48 4.84 4.74 4.64 4.56
T.C. 37.8 34.5 31.6 28.6 38.1 34.8 31.8 28.9 38.1 34.8 31.9 30.2
S.C. 28.6 28.3 28.8 28.5 29.6 29.6 29.7 29.3 30.7 30.6 30.9 30.7
K.W 5.19 5.07 4.94 4.81 5.25 5.13 4.99 4.88 5.30 5.18 5.06 4.99
Multipliers for determining the performance with other indoor sections.
Air Handler Coil
N1AHC16 G2FD042(S,H)21 0.99 0.99 1.00
N1AHC16 G2FD048(S,H)21 1.02 1.02 1.01
N1VSC16 G2FD048(S,H)21 1.04 1.04 0.95
F2FP045 1.04 1.04 0.99
F2FP048 1.01 1.01 1.02
F2RP/FP042 0.99 0.99 1.01
G1NA048S21D 0.99 0.99 0.99
G1UA048S17 1.00 1.00 1.00
G1UA048S21 1.01 1.01 1.00
G1HD048 1.00 1.00 1.00
G1UA060S21,24 1.04 1.04 1.00
G1FA060S21,24 1.04 1.04 1.00
G2FD042(S,H)21 0.99 0.99 1.00
G2FD046(S,H)17 1.00 1.00 1.00
G2FD048(S,H)21,24 1.02 1.02 1.01
G1FA048S21 1.01 1.01 1.00
G2FD060(S,H)21,24 1.04 1.04 1.00
T.C. S.C. KW
Variable Speed Furnace
P1XUC20V G2FD048(S,H)21 0.94 0.93 0.79
P1DUB16V G1FA048S17 1.00 1.00 0.98
P1DUB16V G1HD048 1.01 1.01 0.95
P1DUB16V G1UA048S17 1.00 1.00 0.98
P1DUB16V G2FD046(S,H)17 1.01 1.01 0.97
P1DUC20V G1FA048S21 1.04 1.04 0.96
P1DUC20V G1FA060S21 1.05 1.05 0.97
P1DUC20V G1HD048 1.01 1.01 0.97
P1XUC20V G2FD042(S,H)21 1.00 1.00 0.98
P1XUC20V G2FD048(S,H)21 1.04 1.04 0.95
P1DUC20V G1UA048S21 1.04 1.04 0.96
P1DUC20V G1UA060S21 1.05 1.05 0.97
P1DUC20V G2FD042(S,H)21 1.05 1.05 0.97
P1DUC20V G2FD048(S,H)21 1.04 1.04 0.95
P1XDD20V G2FD048(S,H)24 1.02 1.02 0.96
P1XUC16V G1FA048S21 1.02 1.02 0.95
P1XUC16V G1FA060S21 1.05 1.05 0.95
P1XUC16V G1UA048S21 1.02 1.02 0.95
P1XUC16V G1UA060S21 1.05 1.05 0.95
P1XUC16V G2FD042(S,H)21 1.00 1.00 0.95
P1XUC16V G2FD048(S,H)21 1.04 1.04 0.96
P1XUC20V G1FA048S21 1.04 1.04 0.96
P1XUC20V G1FA060S21 1.05 1.05 0.96
P1XUC20V G1UA048S21 1.04 1.04 0.96
P1XUC20V G1UA060S21 1.05 1.05 0.96
Coil
T.C. S.C. KW
16 Unitary Products Group
Page 17
COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H4DH048S06
INDOOR COIL MODEL NO. G1FA048S21
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
ID CFM 1450 1600 1750
ID DB 85 80 75 70 85 80 75 70 85 80 75 70
ID WB 72 67 62 57 72 67 62 57 72 67 62 57
T.C. 56.8 52.2 47.7 43.6 57.4 52.9 48.4 44.2 57.9 53.4 48.8 44.9
S.C. 35.8 36.0 36.4 36.6 37.2 37.4 37.9 38.0 38.6 38.8 39.3 39.7
K.W 3.71 3.68 3.65 3.63 3.77 3.74 3.71 3.68 3.84 3.80 3.77 3.75
T.C. 54.6 50.3 45.9 41.9 55.3 50.9 46.5 42.6 55.8 51.4 47.0 43.1
S.C. 35.1 35.2 35.8 35.9 36.7 36.9 37.3 37.5 38.1 38.3 38.8 39.1
K.W 4.12 4.09 4.05 4.02 4.17 4.14 4.11 4.08 4.24 4.20 4.17 4.15
T.C. 51.6 47.4 43.3 39.6 52.2 48.0 43.8 40.1 52.5 48.3 44.2 40.5
S.C. 34.2 34.3 34.7 35.1 35.8 36.0 36.4 36.6 37.2 37.3 37.9 37.9
K.W 4.58 4.54 4.51 4.47 4.63 4.60 4.56 4.53 4.70 4.66 4.63 4.60
T.C. 48.3 44.5 40.5 36.9 48.8 44.8 40.9 37.5 49.0 45.1 41.4 37.9
S.C. 33.2 33.5 33.9 33.8 34.8 34.9 35.4 35.4 36.3 36.4 37.0 36.9
K.W 5.10 5.06 5.02 4.98 5.15 5.12 5.08 5.04 5.22 5.18 5.14 5.11
T.C. 45.0 41.2 37.6 34.4 45.3 41.1 38.1 34.9 45.5 42.0 38.4 36.0
S.C. 32.2 32.2 32.6 32.8 33.8 33.5 34.4 34.3 35.4 35.7 35.7 36.0
K.W 5.69 5.65 5.59 5.54 5.75 5.67 5.65 5.60 5.81 5.76 5.72 5.69
T.C. 41.7 37.9 34.7 31.9 41.8 37.4 35.3 32.3 42.0 38.9 35.4 34.1
S.C. 31.2 30.9 31.3 31.8 32.8 32.1 33.4 33.2 34.5 35.0 34.4 35.1
K.W 6.28 6.24 6.16 6.10 6.35 6.22 6.22 6.16 6.40 6.34 6.30 6.27
036-21020-003 Rev. C (0203)
Multipliers for determining the performance with other indoor sections.
Air Handler Coil
N1AHC16 G2FD048(S,H)21 1.01 1.01 1.00
N1AHD20 G2FD060(S,H)24 1.04 1.04 1.00
N1VSC16 G2FD048(S,H)21 1.02 1.02 0.96
N1VSD20 G2FD060(S,H)24 1.05 1.05 0.97
F2FP048 1.00 1.00 1.00
F2FP060 1.02 1.02 1.03
F2FV060 1.05 1.05 0.92
G1HD048 1.02 1.02 1.01
G1HD060 1.03 1.03 1.00
G1NA048S21D 0.98 0.98 0.99
G1UA048S17 1.00 1.00 1.00
G1UA048S21 1.00 1.00 1.00
G1UA060S21,24 1.03 1.03 1.00
G1FA060S21,24 1.03 1.03 1.00
G2FD046(S,H)17 0.98 0.98 1.00
G2FD048(S,H)21,24 1.01 1.01 1.00
G2FD060(S,H)24 1.04 1.04 1.00
G1FA048S17 1.00 1.00 1.00
T.C. S.C. KW
Variable Speed Furnace
P1DUB16V G1FA048S17 1.01 1.01 0.94
P1DUB16V G1UA048S17 1.01 1.01 0.94
P1DUC20V G1FA048S21 1.00 1.00 0.98
P1DUC20V G1FA060S21 1.03 1.03 0.98
P1DUC20V G1HD048 1.02 1.02 0.99
P1DUC20V G1UA048S21 1.00 1.00 0.98
P1DUC20V G1UA060S21 1.03 1.03 0.98
P1DUC20V G2FD048(S,H)21 1.01 1.01 0.98
P1XDD20V G2FD048(S,H)24 1.03 1.03 0.95
P1XUC16V G1FA048S21 1.00 1.00 0.98
P1XUC16V G1FA060S21 1.03 1.03 0.97
P1XUC16V G1UA048S21 1.00 1.00 0.98
P1XUC16V G1UA060S21 1.03 1.03 0.97
P1XUC16V G2FD048(S,H)21 1.01 1.01 0.97
P1XUC20V G1FA048S21 1.00 1.00 0.96
P1XUC20V G1FA060S21 1.03 1.03 0.98
P1XUC20V G1UA048S21 1.00 1.00 0.96
P1XUC20V G1UA060S21 1.03 1.03 0.98
P1XUC20V G2FD048(S,H)21 1.01 1.01 0.95
P1XUD20V G1FA060S24 1.03 1.03 0.98
P1XUD20V G1UA060S24 1.03 1.03 0.98
P1XUD20V G2FD048(S,H)24 1.01 1.01 0.99
P1XUD20V G2FD060(S,H)24 1.04 1.04 0.99
Coil
T.C. S.C. KW
Unitary Products Group 17
Page 18
036-21020-003 Rev. C (0203)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. H4DH060S06
INDOOR COIL MODEL NO. G1FA060S21,24
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
NOTE:
ID CFM 1600 1800 2000
ID DB 85 80 75 70 85 80 75 70 85 80 75 70
ID WB 72 67 62 57 72 67 62 57 72 67 62 57
T.C. 66.8 61.8 56.9 52.3 67.5 62.5 57.5 52.9 68.0 63.0 58.0 53.6
S.C. 42.8 43.2 43.9 44.3 44.3 44.7 45.4 45.8 45.7 46.1 46.9 47.7
K.W 4.44 4.40 4.35 4.30 4.50 4.46 4.41 4.37 4.56 4.51 4.47 4.42
T.C. 64.8 59.9 55.0 50.5 65.3 60.5 55.6 51.3 65.8 60.9 56.0 51.8
S.C. 42.4 42.8 43.4 43.8 44.0 44.3 45.0 45.6 45.5 45.9 46.6 47.2
K.W 4.90 4.86 4.81 4.76 4.97 4.92 4.87 4.82 5.02 4.98 4.93 4.88
T.C. 62.7 58.1 53.3 48.9 63.2 58.5 53.7 49.5 63.8 59.0 54.3 50.0
S.C. 41.9 42.5 42.9 43.3 43.6 43.9 44.6 45.2 45.5 45.8 46.5 46.8
K.W 5.43 5.38 5.33 5.28 5.49 5.45 5.40 5.35 5.54 5.50 5.45 5.40
T.C. 60.3 55.7 51.1 47.0 60.6 56.1 51.6 47.4 61.0 56.5 52.0 47.8
S.C. 41.3 41.4 42.1 42.6 42.8 43.1 43.9 44.1 44.5 44.8 45.5 45.7
K.W 6.03 5.98 5.93 5.88 6.10 6.05 6.00 5.95 6.15 6.10 6.05 6.00
T.C. 57.3 53.0 48.5 44.5 57.6 53.3 49.1 45.1 58.0 53.6 49.5 45.4
S.C. 40.2 40.4 40.8 41.1 41.7 41.9 42.9 43.0 43.6 43.6 44.5 44.5
K.W 6.70 6.64 6.61 6.55 6.76 6.72 6.66 6.61 6.81 6.77 6.72 6.67
T.C. 54.3 50.3 45.9 42.0 54.6 50.5 46.6 42.8 55.0 50.7 47.0 43.0
S.C. 39.1 39.4 39.5 39.6 40.6 40.7 41.9 41.9 42.7 42.4 43.5 43.3
K.W 7.37 7.30 7.29 7.22 7.42 7.39 7.32 7.27 7.47 7.44 7.39 7.34
Multipliers for determining the performance with other indoor sections.
Air Handler Coil
N1AHD20 G2FD060(S,H)24 1.00 1.00 1.00
N1AHD20 G2FD061H24 1.03 1.03 1.01
N1VSD20 G2FD060(S,H)24 1.01 1.01 0.98
N1VSD20 G2FD061H24 1.03 1.03 0.97
F2FP060 1.01 1.01 1.02
F2FV060 1.01 1.01 0.95
G2FD061H24 1.03 1.03 1.01
G1HD060 1.01 1.01 1.00
G1UA060S21,24 1.00 1.00 1.00
G2FD060(S,H)24 1.00 1.00 1.00
T.C. S.C. KW
Variable Speed Furnace
P1DUC20V G1FA060S21 1.01 1.01 1.00
P1DUC20V G1HD060 1.01 1.01 0.97
P1XDD20V G2FD060(S,H)24 1.00 1.00 1.00
P1XUC20V G1FA060S21 1.01 1.01 1.00
P1XUC20V G1UA060S21 1.01 1.01 1.00
P1XUD20V G1FA060S24 1.01 1.01 1.00
P1XUD20V G1UA060S24 1.01 1.01 1.00
P1XUD20V G2FD060(S,H)24 1.01 1.01 1.00
P1XUD20V G2FD061H24 1.03 1.03 0.99
P1DUC20V G1UA060S21 1.01 1.01 1.00
Coil
T.C. S.C.
KW
18 Unitary Products Group
Page 19
MATCHING INDOOR COMPONENTS
ADD-ON COILS - FOR FURNACE APPLICATIONS
036-21020-003 Rev. C (0203)
G1UA 1/2 CASED UPFLOW
G1FA FULL CASED UPFLOW
* Available with factory installed horizontal drain pan.
G1HD HORIZONTAL DUCT
AIR HANDLERS - FOR NON-FURNACE APPLICATIONS
G1NA UNCASED UPFLOW
G2FD* MULTI-POSITION (UPFLOW, HORIZONTAL AND DOWNFLOW)
N1AH OR N1VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW)
G2FD COIL
F2RC / F2FC OR F2RC / F2FP / F2FV FAN COIL UNITS (UPFLOW, HORIZONTAL)
Unitary Products Group 19
Page 20
NOTES
Subject to change without notice. Printed in U.S.A. 036-21020-003 Rev. C (0203) Copyright © by York International Corp. 2003. All rights reserved. Supersedes: 036-21020-003 Rev. B (0702)
Unitary 5005 Norman Product York OK Group Drive 73069