These compact units (31-1/2" high) employ induced combustion, reliable electronic ignition and high heat transfer heat
exchangers. The units may be factory shipped for upflow/horizontal application and converted for downflow application.
These units may also be factory shipped for downflow application and converted for upflow/horizontal applications
Note: The 150 MBH input model is upflow/horizontal only and
may not be converted to the downflow position.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, or garage. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel
Gas Code.
1. 4-Position models may be factory configured as upflow (MU) or downflow (MD) models.
2. All models are supplied with 3" vent connections. An installer supplied transition to 4" or 5" must be used where necessary.
** 3-Position 150 MBH model available only in upflow/horizontal (UH) configuration.
Dimensions "B", "C", "D" & "E" are with duct flanges turned up. "F", "G", "H" & "J" are with flanges flat.
1
17-1/216-1/220-3/8201614-3/418-3/415-1/819
1
212020-3/82019-1/218-1/418-3/418-5/819
1
212020-3/82019-1/218-1/418-3/418-5/819
2
4
2
4
2
4
2
4
2
5
2
5
RATINGS & PHYSICAL/ELECTRICAL DATA
Heat
Model
Cap.
Input
MBH
G8C05012(MU,MD)B12
G8C07512(MU,MD)B12
G8C07516(MU,MD)C12
G8C10016(MU,MD)C12
G8C10020(MU,MD)D11
G8C12520(MU,MD)D11
G8C15020UHD11**15012040-701703/4(2) 10 x 610.31514
1. 4-Position models may be factory configured as upflow (MU) or downflow (MD) models.
** 3-Position 150 MBH model available only in upflow/horizontal (UH) configuration.
NOTE: For altitudes above 2,000 ft., reduce capacity 4% for each 1,000 ft. above sea level.
Wire size based on copper conductors, 60° C, 3% voltage drop.
Continuous return air temperature must not be below 55° F.
1
504030-601601/310 x 86.71514
1
756035-651651/310 x 86.71514
1
756030-601601/210 x 108.51514
1
1008040-701701/210 x 108.51514
1
1008035-651653/4(2) 10 x 610.31514
1
12510040-701703/4(2) 10 x 610.31514
2Unitary Products Group
Output
MBH
Air Temp
Rise °F
Max.
Outlet
Temp . °F
Blower
HPSize
Tota l
Unit
Amps
Max.
OverCurrent
Breaker
Min. Wire
Size (AWG)
@ 75 Ft.
One Way
BLOWER PERFORMANCE
TABLE 1: SINGLE SIDE RETURN -
All airflow is expressed in standard cubic feet per minute. Motor rated at 115 volts. No air filters.
MODEL
G8C05012(MU,MD)B12
G8C07512(MU,MD)B12
G8C07516(MU,MD)C12
G8C10016(MU,MD)C12
G8C10020(MU,MD)D11
G8C12520(MU,MD)D11
G8C15020UHD11
SPEED
TAP
HIGH141113601289121811541075983882
MEDIUM12131177113410851022960880782
LOW887884871848814775726656
HIGH15351470140813431275120211151014
MEDIUM121511991182115111061039976887
LOW875874864847827799736658
HIGH17921724163015521462136712641152
MEDIUM15971555149614441372128711901086
LOW1115114011671183114910931023939
HIGH18681781169016001498139612771156
MEDIUM16021553150314471376128711811060
LOW1147114711471147113210781009918
HIGH
MED. HI
MED.LO
LOW
HIGH
MED. HI
MED.LO
LOW
HIGH
MED. HI
MED.LO
LOW
036-21120-002 Rev. A (1102)
EXTERNAL STATIC PRESSURE, INCHES W.C.
0.10.20.30.40.50.60.70.8
NOT APPROVED
TABLE 2: DUAL RETURN (TWO SIDES OR ONE SIDE & BOTTOM)-
All airflow is expressed in standard cubic feet per minute. Motor rated at 115 volts. No air filters.