DESCRIPTION
The 14 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be custom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-On coils are available for use
with upflow, downflow, or horizontal furnaces and air handlers.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed
of copper tube and aluminum fins.
• PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and desert sand matted-textured
finish insure less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls,
and the molex plug in the control box connecting the condenser fan make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
036-21004-002 Rev. B (0602)
h
.
Physical and Electrical Data
MODEL
Unit Supply Voltage208 / 230 - 1 – 60
Normal Voltage Range
Minimum Circuit Ampacity12.114.918.117.820.631.8
Max Overcurrent Device Amps
Compressor Type
Compressor Amps
Crankcase HeaterNoNoNoNoNoNo
Fan Motor AmpsRated Load.51.31.31.31.31.4
Fan Diameter Inches222222242424
Fan Motor
Coil
Liquid Line OD3/83/83/83/83/83/8
Vapor Line OD7/87/87/81 1/81 1/81 1/8
Unit Charge (Lbs - Oz)
Charge Per Foot, oz.0.700.700.700.760.760.76
Operating Weight Lbs209228219240264270
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker.
3. All scrolls listed with superscript “B” are Bristol scrolls. All scrolls listed with superscripts “C” are Copeland scrolls.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15
feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
Rated HP1/151/41/41/41/41/3
Nominal RPM8308258258258251100
Nominal CFM2,2603,3003,3003,3003,3003,500
Face Area Sq Ft19.6523.5823.5822.527.027.0
Rows Deep111222
Fin /Inch181818181818
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
F2FP0455,8,10,1524-140040.529.8-14.0012.00
F2FP0485,8,10,15,20,2524-140039.528.9-13.2511.30
F2FP0605,8,10,15,20,2524-160046.033.4-13.0011.25
F2FV0608,10,15,20,2524-162547.534.9-15.5013.20
F2FP06010,15,20,2524--190053.036.7-13.0011.60
F2FV06010,15,20,2524--190053.536.3-13.7512.35
EER
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
- = Not applicable
. models. All ratings remain the same.
Unitary Products Group3
036-21004-002 Rev. B (0602)
COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils