TECHNICAL GUIDE
ADD - ON COILS FOR USE WITH SPLIT -SYSTEM COOLING & HEAT PUMPS
MODELS: CF, CM, CU 600 - 2000 CFM 1.5 - 5 TON COILS
Due to continuous product improvement, specifications are subject to change without notice.
Visit us on the web at:
www.upgnet.com and www.york.com
Additional rating information can be found at:
www.ahridirectory.org
UPFLOW/DOWNFLOW
FULL CASED
CF
FULL CASED
MULTI-POSITION
CM
UPFLOW
UNCASED
CU
A0368-001
ISO 9001
Certified Quality
Management System
5005743-YTG-C-0815
DESCRIPTION
These indoor coils are designed to be installed with UPG fur­naces or modular air handlers and matched with UPG cooling and heat pump outdoor units. All coil models are available as “flex-coil” units without a factory installed metering device. Flex­coil models allow these coils to be used with R-410A or R-22 for added flexibility to meet refrigerant system choice. A piston or TXV metering device should be installed in the field to meet your system requirements.
CF Models, Full Case Coils - Full cased coils are suitable for use in upflow or downflow applications.
CM Models, Multi-Position Coils - CM coils have the added flexibility that allow them to be installed in any position - upflow, downflow, or horizontal (right or left). This coil can be easily installed with a UPG furnace or modular air handler in any con­figuration.
CU Models, Uncased Coils - These coils are designed for installation on top of upflow furnaces, and they are to be used for upflow only applications. The uncased coils require field modification of the furnace duct for the coil installation.
FEATURES
RC2 - Rigid Case Construction interior endoskeleton for struc-
tural support, flush side, and locks in insulation. Powder-painted - G30 galvanized steel case provide a coated
edge that resists corrosion and rust creep.
MaxAlloy
TM
Coil - Long life aluminum coils built to deliver last-
ing performance, efficiency and reliability. Quality Construction - Structural components are made of
Aluminum or G90 galvanized steel to prevent corrosion. Improved Insulation Design - Single piece with no external
screws to reduce thermal transmission paths to prevent sweat­ing. Foil faced insulation for ease of cleaning.
Thermostatic Expansion Valve - Bolt-on TXV provides easy installation to convert the indoor coil to the required refrigerant that does not require brazing to replace or install. Some models are available with factory installed TXVs.
Case Depth - These models have 20.5” casing which provide ease of attic access and tight applications.
Thermal Plastic Drain Pan
- Positive slope for drainage to
reduce cause for potential mold or contaminates.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ACCESSORIES
Refer to Price Manual for specific model numbers. TXV Kits - Thermal expansion valve kits are available for flex-
coil applications with R-410A refrigerant. All TXV kits are non­braze. All connections are bolt-on including the valve assembly and equalizer tube. No orifice or any other metering device is to be used in conjunction with the TXV.
Partial Case – Available to be used with CU coils in four widths. This option is intended for upflow applications where height lim­itations in the application prevent the installation of full cased coils. The partial case design allows the top section of the indoor coil to be installed in the duct or plenum.
Coil Casing Without Coil - Coil casings are available in four widths that can be installed with the furnace or modular air han­dler during initial installation. This option is available to allow the installer the flexibility to add the coil at a later date without duct modifications.
UVC Germicidal Light - The UVC technology effectively pre­vents mold, bacteria, and other microorganisms that develop in air handling systems. The UVC Light Kit provides safe, continu­ous cleaning while actually saving money by reducing HVAC system maintenance and energy consumption.
5005743-YTG-C-0815
A
19-1/8”
(OPENING)
C (OPENING)
19-1/8"
D (OPENING)
21-1/2”
A0322-001
BOTTOM OPENING
DIMENSIONS
20-1/2”
B
A
B
19-1/8”
(OPENING)
C
(OPENING)
19-1/8"
D (OPENING)
A0323-001
BOTTOM OPENING
DIMENSIONS
20-1/2”
21-1/2”
DIMENSIONS
1
Models
CF18A*A1 19-1/2 14-1/2 13-1/2 13-1/2
CF18BXA1 19 17-1/2 16-1/2 16-1/2
CF24A*A1 19-1/2 14-1/2 13-1/2 13-1/2 CF24BXA1 19 17-1/2 16-1/2 16-1/2 CF24CXA1 21 21 20 20 CF30AXA1 21-5/8 14-1/2 13-1/2 13-1/2
CF30B*A1 23 17-1/2 16-1/2 16-1/2 CF30CXA1 21 21 20 20 CF30DXA1 25 24/1/2 23-1/2 23-1/2 CF36AXA1 25-1/2 14-1/2 13-1/2 13-1/2
CF36B*A1 25-5/8 17-1/2 16-1/2 16-1/2 CF36CXA1 23 21 20 20 CF36DXA1 25 24-1/2 23-1/2 23-1/2 CF42BXA1 25 17-1/2 16-1/2 16-1/2
CF42C*A1 25212020 CF42DXA1 25 24-1/2 23-1/2 23-1/2
CF48C*A1 27212020 CF48DXA1 27 24-1/2 23-1/2 23-1/2
CF60C*A1 33212020 CF60DXA1 32-3/4 24-1/2 23-1/2 23-1/2 CF64DXA1 32-3/4 24-1/2 23-1/2 23-1/2
1. Asterisk (*) denotes coil model is available as a flex coil or with factory installed TXV.
2. All dimensions are in inches.
3. Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077.
4. Adapter fitting must be field installed for other line set size.
5. See outdoor unit technical guide for proper line set size.
Height Width Opening Widths Line Size
ABCDLiquidVapor
Dimensions
2
Refrigerant
Connections
3,4,5
3/4
3/8
7/8
1
Models
Height Width Opening Widths Line Size
ABCDLiquidVapor
CM18A*A1 19-1/2 14-1/2 13-1/2 13-1/2
CM18BXA1 19 17-1/2 16-1/2 16-1/2
CM24A*A1 19-1/2 14-1/2 13-1/2 13-1/2 CM24B*A1 19 17-1/2 16-1/2 16-1/2
CM24CXA1 21 21 20 20
CM30A*A1 25-1/2 14-1/2 13-1/2 13-1/2
CM30B*A1 23 17-1/2 16-1/2 16-1/2 CM30CXA1 23 21 20 20 CM30DXA1 25 24/1/2 23-1/2 23-1/2 CM36AXA1 25-1/2 14-1/2 13-1/2 13-1/2
CM36B*A1 25-5/8 17-1/2 16-1/2 16-1/2
CM36C*A1 25 21 20 20 CM36DXA1 25 24-1/2 23-1/2 23-1/2
CM42C*A1 27 21 20 20 CM42DXA1 27 24-1/2 23-1/2 23-1/2
CM48C*A1 33 21 20 20
CM48D*A1 32-3/4 24-1/2 23-1/2 23-1/2
CM60C*A1 33 21 20 20
CM60D*A1 32-3/4 24-1/2 23-1/2 23-1/2 CM64DXA1 32-3/4 24-1/2 23-1/2 23-1/2
1. Asterisk (*) denotes coil model is available as a flex coil or with factory installed TXV.
2. All dimensions are in inches.
3. Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077.
4. Adapter fitting must be field installed for other line set size.
5. See outdoor unit technical guide for proper line set size.
Dimensions
2
Refrigerant
Connections
3,4,5
3/4
3/8
7/8
2 Johnson Controls Unitary Products
5005743-YTG-C-0815
A
A0350-002
B
21”
Dimensions
Models
Height Width Line Size
A B Liquid Vapor
CU18AXA1 13-3/8 13-3/8 CU18BXA1 13-1/4 CU24AXA1 15-3/8 CU24BXA1 15-1/4 CU24CXA1 14-7/8 CU30AXA1 19-3/8 CU30BXA1 19-1/2 CU30CXA1 19-1/4 CU30DXA1 19 CU36BXA1 21-1/2 CU36CXA1 21-1/8 CU36DXA1 21-1/4 CU42CXA1 23-1/8 CU42DXA1 22-7/8 CU48CXA1 25-1/8 CU48DXA1 25 CU60CXA1 29-1/4 CU60DXA1 29
1. All dimensions are in inches.
2. Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077.
3. Adapter fitting must be field installed for other line set size.
4. See outdoor unit technical guide for proper line set size.
16-3/8 13-3/8 16-3/8 19-7/8 13-3/8 16-3/8 19-7/8 23-3/8 16-3/8 19-7/8 23-3/8 19-7/8 23-3/8 19-7/8 23-3/8 19-7/8 23-3/8
1
Refrigerant
Connections
3/8
2,3,4
3/4
7/8
COOLING CAPACITY
UPFLOW "N" TYPE COIL - COOLING CAPACITY (Coil Only1)
Models Rated CFM
CF18A 600
CF18B 600
CF24A 800
CF24B 800
CF24C 800
CF30A 1000
CF30B 1000
For notes see Page 4.
Entering Air
Dry/Wet Bulb (°F)
85/72 45.7 41.6 36.8 30.5 80/67 38.5 33.9 28.5 22.3 75/62 31.5 26.5 20.5 15.9 70/57 24.4 19.5 15.2 11.5 85/72 45.7 41.6 36.8 30.5 80/67 38.5 33.9 28.5 22.3 75/62 31.5 26.5 20.5 15.9 70/57 24.4 19.5 15.2 11.5 85/72 52.2 47.5 41.8 35.0 80/67 43.6 38.3 31.9 24.5 75/62 35.2 29.5 22.7 16.2 70/57 27.1 20.7 15.5 11.4 85/72 52.2 47.5 41.8 35.0 80/67 43.6 38.3 31.9 24.5 75/62 35.2 29.5 22.7 16.2 70/57 27.1 20.7 15.5 11.4 85/72 52.2 47.5 41.8 35.0 80/67 43.6 38.3 31.9 24.5 75/62 35.2 29.5 22.7 16.2 70/57 27.1 20.7 15.5 11.4 85/72 75.3 67.8 56.8 47.1 80/67 62.6 54.6 44.2 34.5 75/62 50.2 41.3 32.0 22.9 70/57 37.8 30.1 21.5 16.2 85/72 75.3 67.8 56.8 47.1 80/67 62.6 54.6 44.2 34.5 75/62 50.2 41.3 32.0 22.9 70/57 37.8 30.1 21.5 16.2
MBH@ Evap. Temp. and Corresponding R-410A Pressure (°F/PSIG)
35/107.9 40/118.9 45/130.7 50/143.3
Johnson Controls Unitary Products 3
5005743-YTG-C-0815
UPFLOW "N" TYPE COIL - COOLING CAPACITY (Coil Only1)
Models Rated CFM
CF30C 1000
CF30D 1000
CF36A 1200
CF36B 1200
CF36C 1200
CF36D 1200
CF42B 1400
CF42C 1400
CF42D 1400
CF48C 1600
CF48D 1600
CF60C 1800
CF60D 1800
CF64D 1800
1. - See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.
Entering Air
Dry/Wet Bulb (°F)
85/72 75.3 67.8 56.8 47.1 80/67 62.6 54.6 44.2 34.5 75/62 50.2 41.3 32.0 22.9 70/57 37.8 30.1 21.5 16.2 85/72 75.3 67.8 56.8 47.1 80/67 62.6 54.6 44.2 34.5 75/62 50.2 41.3 32.0 22.9 70/57 37.8 30.1 21.5 16.2 85/72 91.6 82.4 71.3 59.4 80/67 76.5 65.4 54.6 42.8 75/62 61.3 51.2 40.0 30.5 70/57 47.5 38.1 28.7 22.3 85/72 91.6 82.4 71.3 59.4 80/67 76.5 65.4 54.6 42.8 75/62 61.3 51.2 40.0 30.5 70/57 47.5 38.1 28.7 22.3 85/72 91.6 82.4 71.3 59.4 80/67 76.5 65.4 54.6 42.8 75/62 61.3 51.2 40.0 30.5 70/57 47.5 38.1 28.7 22.3 85/72 91.6 82.4 71.3 59.4 80/67 76.5 65.4 54.6 42.8 75/62 61.3 51.2 40.0 30.5 70/57 47.5 38.1 28.7 22.3 85/72 100.6 89.8 78.2 64.7 80/67 83.5 73.7 59.8 48.0 75/62 67.8 55.8 44.7 32.5 70/57 52.3 41.5 30.7 23.7 85/72 100.6 89.8 78.2 64.7 80/67 83.5 73.7 59.8 48.0 75/62 67.8 55.8 44.7 32.5 70/57 52.3 41.5 30.7 23.7 85/72 100.6 89.8 78.2 64.7 80/67 83.5 73.7 59.8 48.0 75/62 67.8 55.8 44.7 32.5 70/57 52.3 41.5 30.7 23.7 85/72 115.2 105.0 93.9 79.0 80/67 88.3 78.2 65.5 52.6 75/62 72.7 60.8 50.1 37.6 70/57 57.7 46.9 36.6 29.7 85/72 115.2 105.0 93.9 79.0 80/67 88.3 78.2 65.5 52.6 75/62 72.7 60.8 50.1 37.6 70/57 57.7 46.9 36.6 29.7 85/72 115.1 103.0 91.7 78.6 80/67 96.8 85.9 73.7 60.5 75/62 80.7 69.4 57.5 43.5 70/57 58.7 48.9 37.7 32.7 85/72 115.1 103.0 91.7 78.6 80/67 96.8 85.9 73.7 60.5 75/62 80.7 69.4 57.5 43.5 70/57 58.7 48.9 37.7 32.7 85/72 133.6 118.5 103.2 86.6 80/67 111.4 96.2 80.3 62.8 75/62 90.7 75.1 60.0 43.5 70/57 70.6 56.9 42.5 32.8
MBH@ Evap. Temp. and Corresponding R-410A Pressure (°F/PSIG)
35/107.9 40/118.9 45/130.7 50/143.3
4 Johnson Controls Unitary Products