DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom- matched
with one of UPG’s complete line of evaporator sections, each
designed to serve a specific function.
WARRANTY
5-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
•QUALITY CONDENSER COILS - The coil is constructed of
aluminum microchannel tubing and enhanced aluminum fins for
increased efficiency and corrosion protection.
•COIL PROTECTION - Coils are protected from damage by a
polymer mesh applied between the coil face, and a coated steel coil
guard.
•PROTECTED COMPRESSOR - Compressors are internally
protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve
and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor.
•DURABLE FINISH - The cabinet is made of pre-painted steel.
The pre-treated flat galvanized steel provides a better paint-to-steel
bond, which resists corrosion and rust creep. Special primer formulas
and matted champagne finish insure less fading when exposed to
sunlight.
•LOWER INSTALLED COST - Installation time and costs are
reduced by easy power and control wiring connections. The small
base dimension means less space is required on the ground or roof.
•TOP DISCHARGE - The warm air from the top mounted fan is
blown away from the structure and any landscaping. This allows
compact location on multi-unit applications.
•LOW OPERATING SOUND LEVEL - The upward air flow car-
ries the normal operating noise away from the living area. The rigid
top panel effectively isolates any motor sound. Isolator mounted
compressor and the condenser coil muffle the normal fan motor and
compressor operating sounds.
•LOW MAINTENANCE - Long life permanently lubricated motor-
bearings need no annual servicing.
•EASY SERVICE ACCESS - Fully exposed refrigerant connec-
tions and a single panel covering the electrical controls make for
easy servicing of the unit.
•SECURED SERVICE VALVES - Secured re-usable service
valves are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
•U.L. AND C.U.L. LISTED - Approved for outdoor application.
Certified in accordance with the Unitary Small Equipment certification
program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
Unit Supply Voltage208 - 230V, 1 Phase, 60Hz
Minimum Circuit Ampacity8.99.512.014.518.2
Maximum Overprotection Device
Rated Load Amps6.77.28.91113.5
Compressor
Dimensions
Fan & Motor
OD Coil
Connection OD
Line Set OD
RefrigerantR-22R-22R-22R-22R-22
Unit Charge (lbs - oz)
2
Charge Per Foot - oz0.660.660.660.680.68
1. Dual element fuses or HACR circuit breaker.
2. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15
subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
1. Systems matched with furnace or air handlers not equipped with blower-off delays may re quire blower Time Delay Kit #6918A5011
2. These orifices are factory mounted in the flow device of each indoor coil
3. A TXV kit must be used with these coils to obtain system perf ormance (2A, 2B, and 2C indicate 1TVM series)
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for th e condenser, the smallest evaporator and for 15 feet of interconnecting line
tubing.
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tub i ng greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder
for line set.
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80ºF entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95ºF outdoor ambient divided by the total electric power in watt-hours at those conditions
SEER (Seasonal Energy Efficiency Ratio) is the t ot al coolin g ou tput in B UT’s during a normal annual usage period for cooli ng d i vided by t he total electric power
input in watt-hours during the same period.
1. G4FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
COOLING
NET MBH
TOTALSENS.
SEEREER
.
Unitary Products Group5