York AM012M1021, AM018M1021, AM024M1021, AM030M1021 Technical Manual

Page 1
A
A
V
A
036-21573-001 Rev. A (0304)
®
TECHNICAL GUIDE
SPLIT-SYSTEM
IR CONDITIONERS
10 SEER
M012M102 THRU AM030M1021
O
T
A
R
D
I
E
I
A
F
S
I
T
R
C
E
O
C
M
A
P
I
R
R
-
L
C
E
O
Y
N
R
Y
I
D
R
I
U
A
T
T
I
C
N
U
A
F
U N
A
M
C E
R T
I
A
R
This product was manufactured in a plant whose quality system is certified/registered as being in conformity with ISO 9001.
I
Certification applies only
when the complete
system is listed
Due to continuous product improvement, sp e ci f ic a tio ns are subject to change without notice.
isit us on the web at www.york.com for the most
up-to-date technical information.
dditional rating information can be foun d at
www.ariprimenet.org.
R
E
Q
U
I
P
M
F
I
C
A
T
I
O
N
S
T
A
N
with ARI.
N
T
G
I
O
N I
W
N
I
G
T
H
T
F
N
E
O
S
N
O
I
T
0
C
E
S
1
2
D
R
A
D
LISTED
DESCRIPTION
The 10 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be cus­tom-matched with one of UPG’s complete line of evaporator sections, each designed to serve a specific function. Match­ing air handlers are available for upflow, downflow, or hori­zontal applications to provide a complete system. Electric heaters are available if required. Add-on coils are available for use with upflow, downflow, or horizontal furnaces and air handlers.
WARRANTY
5-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed of enhanced copper tube and aluminum fins.
COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard.
PROTECTED COMPRESSOR - Recip compressors are internally protected against high pressure and tempera­ture. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor.
DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a bet­ter paint-to-steel bond, which resists corrosion and rust creep. Special primer formulas and matted desert sand fin­ish insure less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connec­tions. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscap­ing. This allows compact location on multi-unit applica­tions.
LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the livi ng area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con­nections and a single panel covering the electrical controls make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser- vice valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.
U.L. AND C.U.L. LISTED - Approved for outdoor applica­tion.
Certified in accordance with the Unitary Small Equipment cer­tification program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
Page 2
036-21573-001 Rev. A (0304)
Physical and Electrical Data
MODEL
Unit Supply Voltage 208-230V, 1φ, 60Hz Normal Voltage Range
Minimum Circuit Ampacity 8.8 10.1 15.3 19.3 Max. Overcurrent Device Amps
Compressor Type Rotary Recip Recip Recip Compressor Amps Crankcase Heater No No No No
Fan Motor Amps Rated Load 0.5 0.5 0.9 0.9 Fan Diameter Inches 17-1/2 17-1/2 17-1/2 17-1/2
Fan Motor
Coil
Liquid Line OD 3/8 3/8 3/8 3/8 Vapor Line OD 5/8 5/8 5/8 3/4
Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz. 0.66 0.66 0.66 0.68 Operating Weight Lbs. 94 114 119 122
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker.
3. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
1
2
Rated Load 6.7 7.7 11.5 14.7 Locked Rotor 33486073
Rated HP 1/12 1/12 1/8 1/8 Nominal RPM 1,100 1,100 1,075 1,075
Nominal CFM 1,600 1,550 1,750 1,750 Face Area Sq. Ft. 7.22 7.22 7.22 7.94 Rows Deep 1111 Fins / Inch 14 16 20 20
3
AM012M1021 AM018M1021 AM024M1021 AM030M1021
187 to 252
15 15 20 25
3 - 2 3 - 1 3 - 4 3 - 9
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
C
A
Unit
Model
012 22 21-3/4 21-3/4 3/8” 5/8” 018 22 21-3/4 21-3/4 3/8” 5/8” 024 22 21-3/4 21-3/4 3/8” 5/8” 030 24 21-3/4 21-3/4 3/8” 3/4”
1. Including Fan Guard
Dimensions
1
A
(Inches)
B C Liquid Vapor
Refrigerant Connection
Line Size
B
2 Unitary Products Group
Page 3
036-21573-001 Rev. A (0304)
Additional R-22 Charge / Orifice Size for Various Matched Systems
ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS
Outdoor Unit AM012M1021 AM018M1021 AM024M1021 AM030M1021 Unit Orifice (s)
Factory R-22 Charge, lbs-oz 3 - 2 3 - 1 3 - 4 3 - 9
Indoor Coil
G2FD024(S,H)14/17 61 47 + 8 51 + 7 59 + 2 — G2FD030(S,H)17 65 63 + 2 G2FD035(S,H)14 65 63 + 1 G1HD024 59 47 + 7 53 + 6 59 + 3 — G1HD036 69 63 + 7 G1FA/G1UA024S14/17 59 47 + 6 51 + 5 59 + 0 — G1FA/G1UA030S14 65 63 + 3 G1FA/G1UA036S14 73 59 + 6 63 + 3 G1FA/G1UA03617/21 73 63 + 1 G1NA024S17G 51 47 + 0 51 + 0 — G1NA030S17H 57 59 + 2 — G1NA030S17K 63 63 + 2 G1NA030S21B 57 59 + 2 — G1NA030S21M 63 63 + 2 G1NF024SOF 63 59 + 2 63 + 0 F2RP/F2FP018 53 47 + 3 51 + 1 — F2RP/F2FP024 61 51 + 7 59 + 2 — F2RP/F2FP030 65 63 + 2 F2RP/F2FP036 75 63 + 8 MDD30BSD 57 59 + 2 — MDD30MSD 63 63 + 2
FOOTNOTES:
1. These orifices are packed in the customer packet of each outdoor unit.
2. These orifices are factory mounted in the flow control device of each indoor coil.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor, and 15 feet of inter-
2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table.
3. Add charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. T o t al System Charge = Base Charge (as shipped) + adder for
5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size .
1
connecting line tubing.
evaportor + adder for line set.
Coil Orifice
2
47 51 59 63
System Orifice - Additional Charge, Oz
Unitary Products Group 3
Page 4
036-21573-001 Rev. A (0304)
COOLING CAPACITY - With Air Handler Coils
AIR HANDLER
UNIT MODEL
AM012M1021 N1AHB0806 10 17 G2FD024(S,H)17 450 14.5 10.4 10.00 - 10.00 AM018M1021 N1AHB0806 10 17 G2FD024(S,H)17 650 18.6 13.4 10.00 - 9.50 AM024M1021 N1AHB0806 10 17 G2FD024(S,H)17 850 23.4 16.8 10.00 - 9.15 AM030M1021 N1AHB1206 10,15,18 17 G2FD030(S,H)17 1050 28.2 20.3 10.00 - 9.00
AM012M1021 F2RP018 2,5,8 18 - 500 14.5 10.6 10.00 - 9.70 AM018M1021 F2RP/F2FP018 2,5,8 18 - 650 17.4 12.6 10.00 - 9.35 AM018M1021 F2RP/F2FP024 5,8,10 18 - 650 18.6 13.4 10.00 - 9.50 AM024M1021 F2RP/F2FP024 5,8,10 18 - 850 23.4 16.8 10.00 - 9.15 AM030M1021 F2RP/F2FP030 5,8,10,15 18 - 1050 28.4 20.3 10.00 - 9.05 AM030M1021 F2RP/F2FP036 5,8,10,15,19 21 - 1050 29.0 20.7 10.00 - 9.15
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240. Cooling MBH based on 95°F outdoor ambient, 80°F entering air tempera ture, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price p ages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP
5. F2RP air handlers have B.O.D (Blower on Delay) standard.
- = Not applicable.
MODEL
ELECTRIC
HEAT KW
2
1 PH 10 SEER AC WITH N1AH / G2FD
W
1 PH 10 SEER AC / F2RP
. All ratings remain the same.
COIL
MODEL
1
RATED
CFM
4,5
NET MBH
TOTAL SENS.
COOLING
SEER
W/O TXV
SEER
+ TXV
EER
3
ACCESSORIES*
Refer to Price Manual for specific model numbers. Hard Start Kit - Provides increased starting torque for areas
with low voltage. Compressor Blanket - Designed to further reduce the nor-
mal compressor operating sound. Refer to price pages for specific match-ups.
Off Cycle Timer Delay - Provides a 5-minute off cycle to pre­vent rapid recycling of the compressor.
Room Thermostats - A wide selection of compatible thermo­sets are available to provide optimum performance and fea­tures for any installation.
1 Heat Stage only, manual, mechanical thermostat. Add sub­base for 1H/1C.
1H/1C, manual change-over electronic non-programmable thermostat.
1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable. * For the most current accessory information, refer to the
price book or consult factory.
SOUND RATINGS*
SOUND
UNIT MODEL
012 72 018 74 024 75 030 76
*Rated in accordance with ARI Standard 270.
RATINGS
DBA
4 Unitary Products Group
Page 5
COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils
FURNACE
UNIT MODEL
CFM RANGE
(MIN.-MAX.)
AM012M1021
AM018M1021
AM024M1021
AM030M1021
1. Refer to Quick Selection Chart for specific furnace match-up.
2. TXV = Use 1TV700 Series Kit.
250 650
575 725
750 950
925
1175
1
WRATED CFM
COIL
MODEL
NET MBH
TOTAL SENS.
14,17 G1FA024S14,17 450 14.4 10.3 10.00 - 9.95
- G1HD024 450 14.6 10.4 10.00 - 10.00
17 G1NA024S17G 450 14.1 10.0 10.00 - 9.80 14,17 G1UA024S14,17 450 14.4 10.3 10.00 - 9.95 14,17 G2FD024(S,H)14,17 450 14.5 10.4 10.00 - 10.00 14,17 G1FA024S14,17 650 18.3 13.3 10.00 - 9.40
- G1HD024 650 18.5 13.5 10.00 - 9.50
17 G1NA024S17G 650 17.7 12.4 10.00 - 9.50 14,17 G1UA024S14,17 650 18.3 13.3 10.00 - 9.40 14,17 G2FD024(S,H)14,17 650 18.6 13.4 10.00 - 9.50 14,17 G1FA024S14,17 850 23.0 16.6 10.00 - 9.05
14 G1FA036S14 850 23.8 17.2 10.00 - 9.25
- G1HD024 850 23.6 17.0 10.00 - 9.25 17 G1NA030S17H 850 23.6 16.5 10.00 - 9.20 21 G1NA030S21B 850 23.6 16.5 10.00 - 9.20
14,17 G1UA024S14,17 850 23.0 16.6 10.00 - 9.05
14 G1UA036S14 850 23.8 17.2 10.00 - 9.25
14,17 G2FD024(S,H)14,17 850 23.4 16.8 10.00 - 9.15
14 G1FA030S14 1050 28.2 20.2 10.00 - 8.95 14 G1FA036S14 1050 28.2 20.2 10.00 - 8.95
17,21 G1FA036S17,21 1050 28.0 20.0 10.00 - 8.95
- G1HD036 1050 28.4 20.2 10.00 - 9.00 17 G1NA030S17K 1050 28.4 19.9 10.00 - 9.00 21 G1NA030S21M 1050 28.4 19.9 10.00 - 9.00 14 G1UA030S14 1050 28.2 20.2 10.00 - 8.95 14 G1UA036S14 1050 28.2 20.2 10.00 - 8.95
17,21 G1UA036S17,21 1050 28.0 20.0 10.00 - 8.95
17 G2FD030(S,H)17 1050 28.2 20.3 10.00 - 9.00 14 G2FD035(S,H)14 1050 28.0 20.0 10.00 - 8.95
COOLING
SEER
W/O TXV
036-21573-001 Rev. A (0304)
2
SEER + TXV
EER
COOLING PERFORMANCE
AIR TEMP ON CONDENSER
MODEL
SUCT. T/P @
COMPR.
AIR TEMP ON CONDENSER 75°F 95°F 115°F 75°F 95°F 115°F
MODEL
SUCT. T/P @
COMPR.
TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW
AM012M1021
AM018M1021
35 61.5 13.1 1.01 11.6 1.20 10.1 1.40 40 68.5 14.5 1.03 12.8 1.23 11.2 1.44 40 68.5 22.9 2.24 19.3 2.52 16.5 2.74 45 76.0 15.9 1.04 14.1 1.26 12.4 1.47 45 76.0 25.0 2.27 21.6 2.58 18.3 2.83 50 84.0 17.4 1.06 15.5 1.28 13.6 1.51 50 84.0 26.8 2.28 23.9 2.63 20.5 2.92 35 61.5 16.2 1.66 13.1 1.84 11.0 1.96 40 68.5 17.7 1.67 14.9 1.88 12.8 2.04 40 68.5 27.4 2.70 23.1 3.04 19.7 3.30 45 76.0 19.3 169 16.7 1.92 14.2 2.11 45 76.0 29.9 2.74 25.8 3.10 21.9 3.41 50 84.0 20.8 1.70 18.5 1.96 15.9 2.18 50 84.0 32.1 2.75 28.6 3.17 24.5 3.51
AM024M1021
AM030M1021
35 61.5 21.0 2.23 17.0 2.46 14.2 2.63
35 61.5 25.1 2.68 20.3 2.97 17.0 3.17
NOTES:
1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 1superheat and 1sub-cooling at condensing unit. a. Increase capacity 1% for each increase in sub-cooling. b. Decrease capacity 1% for each decrease in sub-cooling.
3. Sub-cooling in excess of 2may result in excessively high condensing temperature with air on condenser above 115°F. Maximum recommended condensing temperature is 140°F.
Unitary Products Group 5
Page 6
036-21573-001 Rev. A (0304)
TYPICAL INSTALLATION
6” CLEARANCE
AROUND PERIMETER
NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF.
TYPICAL FIELD WIRING
MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE
60” OVERHEAD CLEARANCE
WEATHERPROOF DISCONNECT SWITCH
CONTROL ACCESS PANEL
THERMOSTAT
SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT
TO FURNACE OR AIR HANDLER TERMINAL BLOCK
NEC CLASS 1 WIRING
NEC CLASS 2 WIRING
TO INDOOR COIL
GND.
LUG
ALL FIELD WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (NEC) AND/OR LOCAL CODES
POWER WIRING
208-230, 1 , 60 Hzf
24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2)
FURNACE OR AIR HANDLER TERMINAL BLOCK
POWER WIRING CONTROL WIRING FACTORY WIRING
CYRGW
*
TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.
CONTACTOR TERMINALS
COIL
CONDENSING UNIT
YRGW
ROOM THERMOSTAT
*
ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.
6 Unitary Products Group
Page 7
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. AM012M1021 INDOOR COIL MODEL NO. G1NA024S17G
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
ID CFM 400 450 500
ID DB (°F) 85 80 70 85 80 70 85 80 70
ID WB (°F) 72 67 57 72 67 57 72 67 57
T.C. 15.4 14.6 13.8 15.4 14.7 14.0 15.5 14.8 14.2 S.C. 9.6 9.6 9.2 10.0 9.9 9.7 10.3 10.3 10.2 K.W 1.21 1.21 1.21 1.23 1.22 1.22 1.25 1.24 1.24
T.C. 15.2 14.2 13.1 15.3 14.4 13.3 15.4 14.6 13.6 S.C. 9.8 9.5 9.0 10.1 10.0 9.5 10.5 10.4 10.1 K.W 1.32 1.31 1.31 1.34 1.33 1.33 1.36 1.35 1.35
T.C. 15.1 13.8 12.4 15.2 14.1 12.7 15.3 14.4 13.0 S.C. 9.9 9.5 8.8 10.3 10.0 9.3 10.7 10.5 9.9 K.W 1.43 1.42 1.42 1.45 1.44 1.44 1.47 1.46 1.46
T.C. 14.2 13.0 11.6 14.3 13.2 11.9 14.5 13.4 12.1 S.C. 9.5 9.0 8.3 10.0 9.6 8.8 10.5 10.1 9.4 K.W 1.56 1.55 1.53 1.58 1.57 1.55 1.60 1.59 1.57
T.C. 13.3 12.1 10.9 13.5 12.2 11.1 13.6 12.4 11.2 S.C. 9.2 8.6 7.7 9.8 9.1 8.3 10.4 9.7 8.9 K.W 1.69 1.67 1.65 1.71 1.70 1.67 1.73 1.72 1.69
T.C. 12.5 11.3 10.2 12.6 11.3 10.3 12.8 11.3 10.4 S.C. 8.8 8.1 7.2 9.5 8.7 7.8 10.2 9.2 8.4 K.W 1.82 1.80 1.76 1.84 1.82 1.78 1.86 1.85 1.81
036-21573-001 Rev. A (0304)
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
N1AHB0806 G2FD024(S,H)17 1.03 1.04 1.01 F2RP018 1.03 1.06 1.04
G1FA024S14,17 1.02 1.03 1.01 G1HD024 1.04 1.04 1.01 G1UA024S14,17 1.02 1.03 1.01 G2FD024(S,H)14,17 1.03 1.04 1.01
T.C. S.C. KW
Unitary Products Group 7
Page 8
036-21573-001 Rev. A (0304)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. AM018M1021 INDOOR COIL MODEL NO. G1NA024S17G
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
ID CFM 500 650 800 ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57
T.C. 20.6 19.1 17.8 20.7 19.5 18.3 20.9 19.9 18.8 S.C. 11.311.110.812.012.012.112.713.013.4 K.W 1.59 1.58 1.56 1.66 1.64 1.63 1.72 1.71 1.70 T.C. 19.7 18.2 16.5 19.9 18.6 17.1 20.1 19.0 17.7 S.C. 11.3 10.9 10.4 12.3 12.2 11.8 13.4 13.5 13.2 K.W 1.70 1.68 1.66 1.77 1.75 1.73 1.84 1.82 1.80 T.C. 18.9 17.3 15.2 19.1 17.7 15.9 19.4 18.0 16.5 S.C. 11.3 10.8 9.9 12.6 12.4 11.5 14.0 13.9 13.0 K.W 1.81 1.79 1.76 1.88 1.86 1.83 1.95 1.92 1.90 T.C. 17.4 15.5 13.5 17.7 16.0 14.1 18.1 16.6 14.7 S.C. 10.7 10.0 9.2 12.4 11.7 10.8 14.0 13.4 12.3 K.W 1.92 1.88 1.84 1.99 1.95 1.91 2.06 2.02 1.98 T.C. 15.9 13.7 11.8 16.4 14.4 12.4 16.9 15.1 12.9 S.C. 10.2 9.2 8.5 12.1 11.1 10.1 14.0 12.9 11.6 K.W 2.02 1.96 1.92 2.09 2.04 1.99 2.17 2.12 2.06 T.C. 14.4 11.9 10.1 15.0 12.8 10.6 15.7 13.7 11.1 S.C. 9.7 8.4 7.8 11.8 10.4 9.4 14.0 12.4 10.9 K.W 2.12 2.05 1.99 2.20 2.13 2.07 2.28 2.22 2.15
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
N1AHB0806 G2FD024(S,H)17 1.05 1.08 1.05 F2RP/F2FP018 0.98 1.02 1.00 F2RP/F2FP024 1.05 1.08 1.05
G1FA024S14,17 1.03 1.07 1.04 G1HD024 1.05 1.09 1.05 G1NA024S17G 1.00 1.00 1.00 G1UA024S14,17 1.03 1.07 1.04 G2FD024(S,H)14,17 1.05 1.08 1.05
T.C. S.C. KW
8 Unitary Products Group
Page 9
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. AM024M1021 INDOOR COIL MODEL NO. G1NA030S17H
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
ID CFM 650 850 1050
ID DB (°F) 85 80 70 85 80 70 85 80 70
ID WB (°F) 72 67 57 72 67 57 72 67 57
T.C. 28.0 26.3 23.9 28.3 26.6 24.7 28.5 27.0 25.5 S.C. 15.5 15.3 14.6 16.9 16.9 16 .5 18.3 18.4 18.5 K.W 2.25 2.21 2.17 2.34 2.30 2.26 2.42 2.39 2.35
T.C. 26.6 24.5 22.5 26.9 25.1 23.1 27.2 25.7 23.7 S.C. 15.4 14.8 13.9 17.0 16.7 15 .9 18.7 18.5 17.8 K.W 2.39 2.33 2.28 2.48 2.43 2.38 2.57 2.53 2.47
T.C. 25.1 22.8 21.0 25.5 23.6 21.5 25.9 24.4 21.9 S.C. 15.2 14.4 13.1 17.1 16.5 15 .2 19.0 18.6 17.2 K.W 2.53 2.46 2.39 2.63 2.57 2.50 2.72 2.68 2.60
T.C. 23.1 20.7 18.5 23.5 21.5 19.1 24.0 22.2 19.7 S.C. 14.4 13.6 12.4 16.5 15.7 14 .4 18.6 17.8 16.3 K.W 2.73 2.64 2.57 2.84 2.75 2.67 2.94 2.85 2.77
T.C. 21.0 18.6 16.1 21.5 19.3 16.8 22.0 19.9 17.5 S.C. 13.7 12.8 11.7 16.0 14.9 13.5 18.3 16.9 15.4 K.W 2.93 2.81 2.75 3.04 2.92 2.84 3.16 3.03 2.94
T.C. 19.0 16.5 13.6 19.5 17.1 14.5 20.1 17.7 15.3 S.C. 13.0 12.1 11.0 15.5 14.1 12.7 18.0 16.1 14.4 K.W 3.122.992.923.253.103.023.383.213.11
036-21573-001 Rev. A (0304)
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
N1AHB0806 G2FD024(S,H)17 0.99 1.02 1.00 F2RP/F2FP024 0.99 1.02 1.00 F2RP/F2FP024 0.79 0.00 0.76
G1FA024S14,17 0.97 1.01 0.99 G1FA036S14 1.01 1.04 1.00 G1HD024 1.00 1.03 0.99 G1NA030S17H 1.00 1.00 1.00 G1NA030S21B 1.00 1.00 1.00 G1UA024S14,17 0.97 1.01 0.99 G1UA036S14 1.01 1.04 1.00 G2FD024(S,H)14,17 0.99 1.02 1.00
T.C. S.C. KW
Unitary Products Group 9
Page 10
036-21573-001 Rev. A (0304)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. AM030M1021 INDOOR COIL MODEL NO. G1NA030S17K
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
ID CFM 850 1050 1250 ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57
T.C. 32.8 31.3 29.0 33.2 31.8 29.9 33.7 32.3 30.7 S.C. 19.6 19.4 19.2 20.4 20.5 20 .5 21.3 21.7 21.9 K.W 2.75 2.72 2.68 2.85 2.81 2.78 2.94 2.90 2.87 T.C. 31.3 29.5 27.1 31.9 30.1 27.9 32.5 30.6 28.7 S.C. 19.2 19.0 18.6 20.4 20.2 20 .0 21.6 21.5 21.3 K.W 2.95 2.89 2.83 3.05 2.99 2.93 3.15 3.08 3.03 T.C. 29.9 27.7 25.3 30.6 28.4 26.0 31.2 29.0 26.7 S.C. 18.9 18.5 18.0 20.4 19.9 19 .4 21.9 21.3 20.7 K.W 3.14 3.06 2.98 3.24 3.16 3.09 3.35 3.27 3.20 T.C. 27.9 25.6 22.9 28.6 26.2 23.6 29.3 26.9 24.4 S.C. 18.1 17.6 16.9 19.7 19.0 18 .4 21.3 20.5 19.8 K.W 3.32 3.22 3.12 3.43 3.33 3.23 3.54 3.44 3.34 T.C. 25.9 23.4 20.5 26.6 24.1 21.3 27.4 24.9 22.1 S.C. 17.4 16.7 15.7 19.0 18.2 17 .3 20.6 19.7 19.0 K.W 3.50 3.37 3.27 3.61 3.49 3.38 3.72 3.60 3.49 T.C. 23.8 21.3 18.1 24.6 22.0 19.0 25.5 22.8 19.8 S.C. 16.7 15.7 14.6 18.3 17.3 16 .3 20.0 18.9 18.1 K.W 3.67 3.53 3.42 3.79 3.65 3.53 3.91 3.77 3.64
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler Coil
N1AHB1206 G2FD030(S,H)17 0.99 1.02 0.99 F2RP/F2FP030 1.00 1.02 0.99 F2RP/F2FP036 1.02 1.04 1.00
G1FA030S14 0.99 1.02 1.00 G1FA036S14 0.99 1.02 1.00 G1FA036S17,21 0.99 1.01 0.99 G1HD036 1.00 1.02 1.00 G1NA030S21M 1.00 1.00 1.00 G1UA030S14 0.99 1.02 1.00 G1UA036S14 0.99 1.02 1.00 G1UA036S17,21 0.99 1.01 0.99 G2FD030(S,H)17 0.99 1.02 0.99 G2FD035(S,H)14 0.99 1.01 0.99
T.C. S.C. KW
10 Unitary Products Group
Page 11
MATCHING INDOOR COMPONENTS
ADD-ON COILS - FOR FURNACE APPLICATIONS
036-21573-001 Rev. A (0304)
G1UA 1/2 CASED UPFLOW
G1FA FULL CASED UPFLOW
* Available with factory installed horizontal drain pan.
G1HD HORIZONTAL DUCT
AIR HANDLERS - FOR NON-FURNACE APPLICATIONS
N-AH OR N-VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW)
G1NA UNCASED UPFLOW
G2FD* MULTI-POSITION (UPFLOW, HORIZONTAL AND DOWNFLOW)
Unitary Products Group 11
G+FD COIL
F+RC / F+FC OR F+RC / F+FP FAN COIL UNITS (UPFLOW, HORIZONTAL)
Page 12
NOTES
Subject to change without notice. Printed in U.S.A. 036-21573-001 Rev. A (0304) Copyright © by York International Corp. 2004. All rights reserved. Supersedes: Nothing