GAS-FIRED
HIGH EFFICIENCY SINGLE STAGE
DOWNFLOW FURNACES
80% AFUE
NATURAL GAS
40 - 130 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
036-21610-002 Rev. A (1104)
DESCRIPTION
These high efficiency, dedicated downflow compact units
employ induced combustion, reliable hot surface ignition and
high heat transfer tubular heat exchangers.
These furnaces are designed for residential installation in a
closet, attic or garage and are ideal for commerci al applications. All units are factory assembled, wired and tested to
assure safe dependable and economical installation and
operation.
These units are Category I listed and may be common
vented with another gas appliance as allowed by the
National Fuel Gas Code ANSI Z223.1 (latest edition).
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applica-
tions.
5-year limited parts warranty.
FEATURES
•Dedicated downflow models may be easily applied without any field conversion
•Top vent connection allows installation in narrow locations
•Electronic hot surface ignition with high reliability and
dependability
•100% shut off main gas valve for added safety
•High velocity filter provided for field installation
•"Diamond Tough" hot surface igniter
•High quality inducer motor for quiet operation
•Standard terminals for controlling humidifiers & EAC's
•40 VA control transformer, fuse protected
•Easy to connect power and control wiring
•Efficiency ratings of 80 AFUE attained by using tubular
heat exchangers
•Cooling relay standard for easy installation of add-on
cooling
•Blower off-delay for cooling SEER improvement
•Multi-speed PSC, direct-drive blower motors to match
cooling requirements
•Adjustable fan-off settings to eliminate "cold-blow"
•Compact 40-in height allows installation in small space
confines
•All models are propane convertible
Due to continuous product improvement, specific ations
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
PS8A12N040DN111501/36.210 x 8 9.01514100
PS8A12N060DN11155 1/36.210 x 8 9.01514110
PS8A12N080DN111651/36.210 x 8 9.01514120
PS8B16N080DN111603/411.011 x10 12.01514130
PS8B12N100DN11170 1/27.010 x 8 12.01514125
PS8C20N100DN11155112.211 x 10 14.02012140
PS8C16N115DN111653/411.011 x 10 12.01514150
PS8C20N115DN11160112.211 x 10 14.02012150
PS8D20N130DN11170112.211 x 10 14.02012160
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
FILTER SIZES
ModelsCabinet SizeTop Return Filter (in)
PS8A12N040DN11A(2) 14 x 20
PS8A12N060DN11A(2) 14 x 20
PS8A12N080DN11A(2) 14 x 20
PS8B16N080DN11B(2) 14 x 20
PS8B12N100DN11B(2) 14 x 20
PS8C20N100DN11C(2) 14 x 20
PS8C16N115DN11C(2) 14 x 20
PS8C20N115DN11C(2) 14 x 20
PS8D20N130DN11D(2) 14 x 20
* ESP (External Static Pressure ) .5" WG is at furnace outlet ahead of cooling coil.
NOTES:
1. All filters must be high velocity cleanable type.
1. Airflow expressed in standard cubic feet per minute (CFM).
2. Motor voltage at 115 V .
BLK
WHT
GRN
BLK (HOT)
WHT (NEUTRAL)
GRN
Line Wiring Connection
4Unitary Products Group
NOMINAL
120 VOLT
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table listed above represents blower performance
WITHOUT filters. To determine the appro ximate blower performance of the system, apply the filter drop value for the filter being used or select an appropriate value from the “Filter
Performance” table shown below.
NOTE: The filter pressure drop values in the “Fi l te r Perf ormance” table shown below are typical values for the type of
filter listed and should only be used as a guideline. Actual
pressure drop ratings for each filter type vary between filter
manufacturer.
* Washable Fiber are the type supplied with furnace (if supplied).
Opening Size
1 Opening 1 Opening1 Opening1 Opening
Disposable
APPLYING FILTER PRESSURE DROP TO
DETERMINE SYSTEM AIRFLOW
To determine the approximate airflow of the unit with a filter in
place, follow the steps below:
Filter Type
WASHABLE
FIBER*
Example: For a 130,000 Btuh furnace with operating on high
speed blower, it is found that total system static is 0.58" w.c.
To determine the system airflow, complete the following
steps:
1.Obtain the airflow values at 0.50" & 0.60" ESP.
1.Select the filter type.
2.Calculate the return opening size in square inches to
determine the proper filter pressure drop.
3.Determine the External System Static Pressure (ESP)
without the filter.
4.Select a filter pressure drop from the table based upon
return air opening size and add to the ESP from Step 3 to
determine the total system static.
5.If total system static matches a ESP value in the airflow
table (i.e. 0.20, 0.60, etc,) the system airflow corresponds to the intersection of the ESP column and Model/
Blower Speed row .
6.If the total system static falls between ESP values in the
table (i.e. 0.58, 0.75, etc.), the static pressure may be
rounded to the nearest value in the table determining the
airflow using Step 5 or calculate the airflow by using the
following example.
This accessory conversion kit may be used to convert natural
gas units for propane (LP) operation at altitudes up to 2,000
ft. Conversion should be made by qualified distributor or
dealer personnel.
COMBUSTIBLE FLOOR BASE
1CB0314 = For 14-1/4" cabinet models
1CB0317 = For 17-1/2" cabinet models
1CB0321 = For 21" cabinet models
1CB0324 = For 24-1/2" cabinet models