York 112, 114, 110, 218, 216 User Manual

Page 1
WATER SYSTEMS
Features
• 6 speed fan
• Cabinet factory tted
• Valve factory tted
• Electrical heater factory tted
• Thermal or modulating valve
• Service valve
Thermostats
CSL00 (Built in) CSR00 (Wall mounted)
Fan speed selector
CML00 (Built in) CMR00 (Wall mounted)
Thermostat with manual fan speed and S/W change over
CEL00 (Built in) CER00 (Wall mounted)
Thermostat with manual fan speed and automatic change over
CEL20 (Built in) CER20 (Wall mounted)
Thermostat with auto. fan speed and automatic change over
CEL30 (Built in) CER30 (Wall mounted)
Thermostat with auto. fan speed and automatic change over for modulating valve
Fan Coil Unit LOW BODY (2 & 4 pipe system)
A complete range from 0.8 kW up to 2.7 kW
Technical features
YLVR - YLIVR
Model 110 112 114 216 218
Cooling capacity (1) 2 rows
Cooling capacity (1) 3 rows
Heating capacity (2) 1 row
Pressure drop (3)
Power supply
Sound power level (3)
Sound pressure level at 3 m
Water connections
W 832 1054 1493 2041 2356
W 913 1266 1790 2327 2714
W 1167 1691 2319 3029 3552
kPa 7 1.7 3.8 9 11.7
V/Ph/Hz 230 / 1 / 50 + E
dB(A) 49 50 53 53 55
dB(A) 31 32 35 35 37
inch 1/2 “
Selection software
Page 2
Fan Coil Unit LOW BODY
0.8 to 2.7 kW
Compatibility table / Codes
Model 110 112 114 216 218
With Cabinet
YLVR
Without Cabinet
YLIVR
Options (Factory fitted)
Coil and heaters
1 row heating BA1
Kit electrical heater (with relay and safety switch) KREL
Built in thermostat
Fan speed selector CSL00
Thermostat with manual fan speed and S/W change over CML00
Thermostat with manual fan speed, dead band, automatic change over
Thermostat with automatic fan speed, dead band, automatic change over
Thermostat with automatic fan speed, dead band, automatic change over for modulating valve
Parallel connection
For ON/OFF valve one/FCU CBL20
For modulating valve one/FCU CBL30
3 way valve factory fitted
For 2 pipe systems ON/OFF J3A2 (2p)
For 4 pipe systems ON/OFF J3A2 (4p)
3 way modulating valve factory fitted
For 2 pipe systems Modulating J3AM (2p)
For 4 pipe systems Modulating J3AM (4p)
Shut off valves factory fitted
For 2 pipe systems DT (2p)
For 4 pipe systems DT (4p)
2 rows
3 rows
4 rows
2 rows
3 rows
4 rows
CEL00
CEL20
CEL30
l l l l l
l l l l l
l l l l l
l l l l l
l l l l l
l l l l l
l l l l l
l l l l l
l
l
l
l
l
l
l
l
l
l
l
l
l
Condensate pump
WS sensor change over for CEL/CER
Minimum temperature thermostat
Accessories (Supplied loose)
Remote controllers and thermostat (wall mounted)
Fan speed selector CSR00
Thermostat with manual fan speed and S/W change over CMR00
Thermostat with manual fan speed, dead band, automatic change over
Thermostat with automatic fan speed, dead band, automatic change over
Thermostat with automatic fan speed, dead band, automatic change over for modulating valve
(1) for check compatibility with the models of FCU see compatibility table
E-COM-H0702
PC
WS
TM
CER00
CER20
CER30
l
l
l
l
l
l
l
l
Page 3
Dimensions
LOW BODY: YLVR
WATER SYSTEMS
YLVR
w R= low body w V= vertical
DIMENSIONS AND WEIGHTS
Dim 110 112 114 216 218
A
B
C
D
E
G
H
J
N
O
P
Q
R
S
T
U
V
W
X
Z
ø
kg
(All dimensions in mm)
648 773 898 1023 1148
374 499 624 749 874
254 254 254 254 254
174 174 174 174 174
100 100 100 100 100
170 170 170 170 170
101 101 101 101 101
430 430 430 430 430
245 245 245 245 245
154 154 154 154 154
31 31 31 31 31
47 47 47 47 47
304 304 304 304 304
88 88 88 88 88
87 87 87 87 87
65 65 65 65 65
47 47 47 47 47
84 84 84 84 84
214 214 214 214 214
109 109 109 109 109
20 20 20 20 20
15 17 22 23 26
YLIVR
w R= low body w V= vertical w I= without cabinet
Page 4
Fan Coil Unit LOW BODY
LOW BODY: YLIVR
DIMENSIONS AND WEIGHTS
Dim 110 112 114 216 218
A
B
C
D
E
G
H
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
ø
kg
(All dimensions in mm)
555 680 805 930 1055
374 499 624 749 874
230 230 230 230 230
108 108 108 108 108
73 73 73 73 73
170 170 170 170 170
101 101 101 101 101
395 395 395 395 395
61 61 61 61 61
349 474 599 724 849
127 127 127 127 127
245 245 245 245 245
154 154 154 154 154
31 31 31 31 31
47 47 47 47 47
304 304 304 304 304
88 88 88 88 88
87 87 87 87 87
65 65 65 65 65
47 47 47 47 47
84 84 84 84 84
214 214 214 214 214
201 201 201 201 201
109 109 109 109 109
20 20 20 20 20
9 11 14 16 19
Page 5
Compatibility tables for FCU LASER and LOW BODY
WATER SYSTEMS
Compatibility table Thermostats / Valves / Heaters / Parallel connection / Water sensor / Minimum temperature thermostat
Factory fitted thermostat (built in)
CSL00
CML00
CEL00
CEL20
CEL30
CEL00 (Built in) CER00 (Wall mounted)
Thermostat with manual fan speed and automatic change over
CEL20 (Built in) CER20 (Wall mounted)
Thermostat with auto. fan speed and automatic change over
CEL30 (Built in) CER30 (Wall mounted)
Thermostat with auto. fan speed and automatic change over for modulating valve
Fan speed selector
Thermostat with manual fan speed and S/W change over
Thermostat with manual fan speed, dead band, automatic change over
Thermostat with automatic fan speed, dead band, automatic change over
Thermostat with automatic fan speed, dead band, automatic change over for modulating valve
CSL00 (Built in) CSR00 (Wall mounted)
Fan speed selector
CML00 (Built in) CMR00 (Wall mounted)
Thermostat with manual fan speed and S/W change over
FEATURES CEL/CER
• Dead band for change over 5°C or 2°C
(factory set 2°C for 4 pipes and 5ºC for 2 pipes)
• Manual fan speeds or automatic
(models 20 and 30)
• Thermostated fan control or continuous
fan running
• Option water sensor WS for change over
on coil (for 2 pipes)
• Led indicated status summer,
winter or dead band
Valves for 2 pipes Valves for 4 pipes Heaters
J3A2 (2p) J3AM (2p) J3A2 (4p) J3AM (4p) KREL CBL20 CBL30 WS TM
l l l l
l l l l l l
l l l l l l
l l l l l
• Temperature setting for 7 to 30°C
(comfort 20-25°C)
• Plastic pins for limiting temperature range
• Input for window contact
• Input for Economy/ occupancy mode
• Output for remote alarm
• Filter alarm 600 or 1200 running hours
(factory set 1200 hours)
• With electrical heater post ventilation
• With Air sensor in the air intake destratication
function (CEL only)
Parallel connection Water
ON/OFF
Modulating
l l
sensor
Min. Temp. Thermostat
Remote controllers and thermostats (wall mounted)
CSR00
CMR00
CER00
CER20
CER30
Fan speed selector a
Thermostat with manual fan speed and S/W change over
Thermostat with manual fan speed, dead band, automatic change over
Thermostat with automatic fan speed, dead band, automatic change over
Thermostat with automatic fan speed, dead band, automatic change over for modulating valve
l Compatible Not compatible
l l
l l l l
l l l l l l
l l l l l l
l l l l l
Page 6
Compatibility tables for FCU LASER and LOW BODY
Compatibility Options / Accessories / Models
STANDARD
LASER CONCEALED
Code designation
Coils and heaters**
BA1**
KREL**
Factory fitted thermostat
CSL00
CML00
CEL00
CEL20
CEL30
Remote controllers and thermostats
CSR00
CMR00
CER00
CER20
CER30
CBL20
CBL30
Valves / Condensate pump / Water sensor / Minimum temperature thermostat (Factory fitted)
J3A2 (2p)
J3A2 (4p)
J3AM (2p)
J3AM (4p)
DT (2p)
DT (4p)
PC
WS
TM
Feets and panels
CP1
ZL1
PPV1
PPH1
External air intake
PA
PAS
PA90°
RCA
PM
PM90
l Compatible Compatible with conditions Not compatible ** Maximum of rows is indicated in the documentation, the maximum number of rows includes the heating row or electrical heater.
Additionnal 1 row heating
Kit electrical heater with safety thermostat and relay
Fan speed selector (buit in)
Thermostat with manual fan speed and S/W change over (buit in)
Thermostat with manual fan speed, dead band, automatic change over (buit in)
Thermostat with automatic fan speed, dead band, automatic change over (buit in)
Thermostat with automatic fan speed, dead band, automatic change over for modulating valves (buit in)
Fan speed selector (wall mounted)
Thermostat with manual fan speed and S/W change over (wall mounted)
Thermostat with manual fan speed, dead band, automatic change over (buit in)
Thermostat with automatic fan speed, dead band, automatic change over (buit in)
Thermostat with automatic fan speed, dead band, automatic change over for modulating valves (buit in)
Parallel connection for ON/OFF valve
Parallel connection for modulating valve
3-way 4-ports on/off valves for 2-pipe systems
3-way 4-ports on/off valves for 4-pipe systems
3-way 4-ports modulating valves for 2-pipe systems
3-way 4-ports modulating valves for 4-pipe systems
Shut-off valves for 2-pipe systems (in addition to J3A2/J3AM valves)
Shut-off valves for 4-pipe systems (in addition to J3A2/J3AM valves)
Condensate pump
Water sensor Compatible with CEL/CER
Minimum temperature thermostat
Set of painted feet
Set of feet + frontal socle
Vertical painted back panel
Horizontal painted back panel
Air intake plenum
Air intake plenum collars
90° air intake plenum
Air intake duct fitting
Air delivery plenum with collars
90° air delivery plenum
YLV YLH YLV-AF YLH-AF YLIV YLIH YLIV-AF YLIH-AF YLVR YLIVR
l l l l l l l l l l
l l l l l l l l
l l l l l l l l l l
Compatible with electrical heaters
Compatible with electrical heaters
l l l l l l l l l l
Compatible with electrical heaters
Compatible with electrical heaters
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l
l l
l l l
l l
l l l l l
l l l l l
LOW BODY
l l
l l
l l
l l
l l
l l
l l
l l
l
l
l
l
Loading...