LOW BODY (2 & 4 pipe system)
A complete range from 0.8 kW up to 2.7 kW
Technical features
YLVR - YLIVR
Model 110112114216218
Cooling capacity (1) 2 rows
Cooling capacity (1) 3 rows
Heating capacity (2) 1 row
Pressure drop (3)
Power supply
Sound power level (3)
Sound pressure level at 3 m
Water connections
Dimensions indicated next page
(1) Cooling capacities based on 7ºC EWT ∆t 5ºC indoor temperature 27ºC DB / 19ºC WB - (2 pipes - high speed fan)
(2) Heating capacities based on 70ºC EWT ∆t 10ºC indoor temperature 20ºC - (2 pipes - high speed fan)
(3) In cooling mode 2 rows
For other conditions contact York international
W8321054149320412356
W9131266179023272714
W11671691231930293552
kPa71.73.8911.7
V/Ph/Hz230 / 1 / 50 + E
dB(A)4950535355
dB(A)3132353537
inch1/2 “
Selection
software
Page 2
Fan Coil Unit LOW BODY
0.8 to 2.7 kW
Compatibility table / Codes
Model110112114216218
With Cabinet
YLVR
Without Cabinet
YLIVR
Options (Factory fitted)
Coil and heaters
1 row heatingBA1
Kit electrical heater (with relay and safety switch)KREL
Built in thermostat
Fan speed selector CSL00
Thermostat with manual fan speed and S/W change overCML00
Thermostat with manual fan speed, dead band, automatic
change over
Thermostat with automatic fan speed, dead band, automatic
change over
Thermostat with automatic fan speed, dead band, automatic
change over for modulating valve
Parallel connection
For ON/OFF valve one/FCUCBL20
For modulating valve one/FCUCBL30
3 way valve factory fitted
For 2 pipe systems ON/OFFJ3A2 (2p)
For 4 pipe systems ON/OFFJ3A2 (4p)
3 way modulating valve factory fitted
For 2 pipe systems ModulatingJ3AM (2p)
For 4 pipe systems ModulatingJ3AM (4p)
Shut off valves factory fitted
For 2 pipe systemsDT (2p)
For 4 pipe systems DT (4p)
2 rows
3 rows
4 rows
2 rows
3 rows
4 rows
CEL00
CEL20
CEL30
lllll
lllll
lllll
lllll
lllll
lllll
lllll
lllll
l
l
l
l
l
l
l
l
l
l
l
l
l
Condensate pump
WS sensor change over for CEL/CER
Minimum temperature thermostat
Accessories (Supplied loose)
Remote controllers and thermostat (wall mounted)
Fan speed selector CSR00
Thermostat with manual fan speed and S/W change overCMR00
Thermostat with manual fan speed, dead band, automatic
change over
Thermostat with automatic fan speed, dead band, automatic
change over
Thermostat with automatic fan speed, dead band, automatic
change over for modulating valve
(1) for check compatibility with the models of FCU see compatibility table
E-COM-H0702
PC
WS
TM
CER00
CER20
CER30
l
l
l
l
l
l
l
l
Page 3
Dimensions
LOW BODY: YLVR
WATER SYSTEMS
YLVR
w R= low body
w V= vertical
DIMENSIONS AND WEIGHTS
Dim 110 112 114 216 218
A
B
C
D
E
G
H
J
N
O
P
Q
R
S
T
U
V
W
X
Z
ø
kg
(All dimensions in mm)
648 773 898 10231148
374 499 624 749 874
254254254254254
174 174 174 174174
100 100 100 100 100
170170170170170
101 101 101 101 101
430430430430430
245245245245245
154154154154154
3131313131
4747474747
304304304304304
8888888888
8787878787
6565656565
4747474747
8484848484
214214214214214
109109109109109
20 20 2020 20
1517222326
YLIVR
w R= low body
w V= vertical
w I= without cabinet
Page 4
Fan Coil Unit LOW BODY
LOW BODY: YLIVR
DIMENSIONS AND WEIGHTS
Dim 110 112 114 216 218
A
B
C
D
E
G
H
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
ø
kg
(All dimensions in mm)
5556808059301055
374 499 624 749 874
230230230230230
108108108108108
7373737373
170170170170170
101 101 101 101 101
395395395395395
6161616161
349474599724849
127127127127127
245245245245245
154154154154154
3131313131
4747474747
304304304304304
8888888888
8787878787
6565656565
4747474747
8484848484
214214214214214
201201201201201
109109109109109
20 20 20 20 20
911141619
Page 5
Compatibility tables for FCU
LASER and LOW BODY
WATER SYSTEMS
Compatibility table Thermostats / Valves / Heaters / Parallel connection / Water sensor /
Minimum temperature thermostat
Factory fitted thermostat (built in)
CSL00
CML00
CEL00
CEL20
CEL30
CEL00 (Built in)
CER00 (Wall mounted)
Thermostat with manual
fan speed and automatic
change over
CEL20 (Built in)
CER20 (Wall mounted)
Thermostat with auto.
fan speed and automatic
change over
CEL30 (Built in)
CER30 (Wall mounted)
Thermostat with auto.
fan speed and automatic
change over for
modulating valve
Fan speed selector
Thermostat with manual fan speed and S/W
change over
Thermostat with manual fan speed, dead band,
automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over for modulating valve
CSL00 (Built in)
CSR00 (Wall mounted)
Fan speed selector
CML00 (Built in)
CMR00 (Wall mounted)
Thermostat with manual
fan speed and S/W
change over
• With Air sensor in the air intake destratication
function (CEL only)
Parallel connectionWater
ON/OFF
Modulating
ll
sensor
Min. Temp.
Thermostat
Remote controllers and thermostats (wall mounted)
CSR00
CMR00
CER00
CER20
CER30
Fan speed selector a
Thermostat with manual fan speed and S/W
change over
Thermostat with manual fan speed, dead band,
automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over for modulating valve
lCompatible
Not compatible
ll
llll
llllll
llllll
lllll
Page 6
Compatibility tables for FCU
LASER and LOW BODY
Compatibility Options / Accessories / Models
STANDARD
LASERCONCEALED
Code designation
Coils and heaters**
BA1**
KREL**
Factory fitted thermostat
CSL00
CML00
CEL00
CEL20
CEL30
Remote controllers and thermostats
CSR00
CMR00
CER00
CER20
CER30
CBL20
CBL30
Valves / Condensate pump / Water sensor / Minimum temperature thermostat (Factory fitted)
J3A2 (2p)
J3A2 (4p)
J3AM (2p)
J3AM (4p)
DT (2p)
DT (4p)
PC
WS
TM
Feets and panels
CP1
ZL1
PPV1
PPH1
External air intake
PA
PAS
PA90°
RCA
PM
PM90
lCompatible Compatible with conditions
Not compatible
** Maximum of rows is indicated in the documentation, the maximum number of rows includes the heating row or electrical heater.
Additionnal 1 row heating
Kit electrical heater with safety thermostat and relay
Fan speed selector (buit in)
Thermostat with manual fan speed and S/W change
over (buit in)
Thermostat with manual fan speed, dead band,
automatic change over (buit in)
Thermostat with automatic fan speed, dead band,
automatic change over (buit in)
Thermostat with automatic fan speed, dead band,
automatic change over for modulating valves (buit in)
Fan speed selector (wall mounted)
Thermostat with manual fan speed and S/W change
over (wall mounted)
Thermostat with manual fan speed, dead band,
automatic change over (buit in)
Thermostat with automatic fan speed, dead band,
automatic change over (buit in)
Thermostat with automatic fan speed, dead band,
automatic change over for modulating valves (buit in)
Parallel connection for ON/OFF valve
Parallel connection for modulating valve
3-way 4-ports on/off valves for 2-pipe systems
3-way 4-ports on/off valves for 4-pipe systems
3-way 4-ports modulating valves for 2-pipe systems
3-way 4-ports modulating valves for 4-pipe systems
Shut-off valves for 2-pipe systems
(in addition to J3A2/J3AM valves)
Shut-off valves for 4-pipe systems
(in addition to J3A2/J3AM valves)