This product is suitable for use in the stated countries. T
product in other countries it is essential to obtain translated
instructions and in some cases the product may require modification.
Contact Yeoman to obtain further details.
o install the
IMPORTANT
The front and top of this cooker will become hot whilst in operation, it is therefore recommended
that a suitable guard should be used for the protection of young children, the elderly or infirm.
Before installation of this product please read these instructions fully.
The installer should complete the commissioning sheet at the start of the User Instructions
PM179 Issue 1 (October 2006)
Contents
Commissioning Data3
Technical Specification4
SITE REQUIREMENTS
Solid Fuel Cooker Dimensions5
Hearth Dimensions5
Walls adjacent to Hearths5
PRE-INSTALLATION CHECKS
Flue or Chimney7
Additional Ventilation8
INSTALLATION INSTRUCTIONS
Installing the Cooker9
Commissioning10
USER INSTRUCTIONS
General11
Care of the Cooker11
Using the stove for the first time11
Date installed:......................................................................................................................................................................................
Model Description:..............................................................................................................................................................................
Company name:...................................................................................................................................................................................
Briquetted smokeless fuel suitable for closed appliances.
(Ancit – Phurnacite – T
aybrite – Homefire ovals)
Top Flue
Flue By-pass
Side Flue
Oven
Cleaning Cover
4
SITE REQUIREMENTS
Before installation of this product please read these
instructions fully.
It is very important to also understand the requirements of the
UK Building Regulations (England and Wales – Document J /
Scotland - Part F), along with any local regulations, and
orking practices that may apply. Should any conflict occur
w
between these instructions and these regulations then the
regulations shall apply.
All electrical connections should meet the requirements of
UK Building Regulations (England and Wales – Document P /
Scotland - Part N).
Your local Building Control Office would be happy to advise
hould questions arise, regarding the requirements of the
s
regulations.
The Solid fuel cooker should be fitted by a HETAS (GB only)
registered installer, or approved by your local building control
officer. Your Stovax dealer should be able to arrange this
service for you.
Your building insurance company may also require you to
nform them that you have installed a new heating appliance,
i
so check with your insurers that your cover is still valid after
installing the Solid fuel cooker.
When completing the installation and building works you
should comply with your responsibilities under the Health and
Safety at Work Acts, and any new regulations, which may be
introduced during the lifetime of these instructions.
faulty installation could cause danger to the inhabitants
A
and structure of the building.
SOLID FUEL COOKER DIMENSIONS (Right hand cooker shown)
Top Flue
Additional information covering the installation the Solid fuel
cooker may be found in the following British Standard: BS8303.
Top Flue
5
SITE REQUIREMENTS
HEARTH DIMENSIONS
The appliance must stand on a constructional hearth with the
minimum dimensions as shown in diagram below.
If you are fitting the appliance into an existing hearth setting
check that it complies with the current construction
regulations and is the minimum sizes shown.
If you have no e
construct a suitable non-combustible housing and hearth
setting. However this should be constructed to comply with
the requirements of both current national and local
regulations with the design approved by your local building
xisting fireplace or chimney, it is possible to
control officer. Masonry chimney systems built with clay or
concrete liners or pre-fabricated block systems should be
constructed in accordance with BS 6461 : Part 1. Factory
made insulated systems should comply with BS 4543 : Part 2
and be installed to BS 7566 : Parts 1 to 4.
Remember that any new chimney added to your property may
also require planning permission.