Yeoman Elegance 200, Elegance 270, Elegance 280, Elegance 210, Elegance 220 Installation, Servicing And User Instructions

...
Page 1
Elegance by Haas & Sohn
Freestanding Multi-Fuel Stove
INSTALLATION, SERVICING AND USER INSTRUCTIONS
Models 200 / 210 / 220 / 240 / 250 / 270 / 280
This product is for use only in Great Britain and Ireland (GB, IE)
, should be read carefully and kept in a safe place. They will be necessary when servicing the appliance.
IMPORTANT
Before installation of this product please read these instructions fully.
The installer should complete the commissioning sheet at the star
t of the User Instr
uctions.
PM173 Issue 2 (August 2006)
Page 2
2
W
elcome to Yeoman
3
C
ommissioning Data
4
T
echnical Specification
5
SITE REQUIREMENTS
S
tove Dimensions
6
H
earth Dimensions
7
Walls adjacent to Hearths 7
PRE-INSTALLATION CHECKS
Flue or Chimney 8 Additional Ventilation 9
INSTALLATION INSTRUCTIONS
Installing the Stove 10 Commissioning 11
OPERATING INSTRUCTIONS
General 12 Using the stove for the first time 12 Burning Wood 12 Burning Solid Fuel 13 Ash Removal 13 Recommended Fuels 14
MAINTENANCE AND SERVICING
General Cleaning 15 Cleaning Glass 15 Chimney Sweeping 15 Annual Service 15
Contents
Page 3
3
Welcome to Yeoman
Your new Elegance multi-fuel stove is perhaps the most advanced design of modern stoves. Owning such a stove shows appreciation for e
xceptional quality.
Please read your manual thoroughly, its purpose is to familiarise you with your stove, and give guidelines for its installation, operation and maintenance. If after reading this manual you need further information, please do not hesitate to contact your Yeoman dealer.
IMPORTANT NOTICE
If your stove is installed correctly
, it will give you many years of excellent service for which it was designed. This appliance must be installed by a HETAS registered installer (GB only).
WARNING
All types of heating appliance can be potentially dangerous. Correct installation and operating procedures must be observed when fitting this stove. Some parts of your stove are protected on their surface with heat proof paint. When the stove is first used it is normal for it to emit some light smoke, with an unpleasant smell. Though unpleasant, this is non toxic and is produced only whilst the stove paint fully cures. W
e recommend that you ventilate the room until this
disappears.
Page 4
FOR YOUR RECORDS
YEOMAN DEALER APPLIANCE WAS PURCHASED FROM
Name: ..................................................................................................................................................................................................
Address:...............................................................................................................................................................................................
.
............................................................................................................................................................................................................
Telephone number:
....................................................................................................................................................
ESSENTIAL INFORMATION - MUST BE COMPLETED
Date installed:......................................................................................................................................................................................
Model Description:..............................................................................................................................................................................
Serial number:
..........................................................................................................................................................
INSTALLATION ENGINEER
Company name:...................................................................................................................................................................................
Address:...............................................................................................................................................................................................
.............................................................................................................................................................................................................
Telephone number:
....................................................................................................................................................................
COMMISSIONING CHECKS (TO BE COMPLETED AND SIGNED)
Is flue system correct for the appliance
YES NO
Flue swept and soundness test complete YES NO
Smoke test completed on installed appliance YES NO
Spillage test completed YES NO
Use of appliance and operation of controls explained YES NO
Instruction books handed to customer YES NO
Signature: ........................................................................................................ Print name:
......................................................
T
o assist us in any Guarantee claim please complete the following information:-
4
Page 5
TECHNICAL SPECIFICATION
5
Model
Elegance 200 YM-EL200 Elegance 210 YM-EL210 Elegance 220 YM-EL220 Elegance 240 YM-EL240 Elegance 250 YM-EL250 Elegance 270 YM-EL270 Elegance 280 YM-EL280
Elegance 200
Elegance 210
Elegance 220
Elegance 240
Elegance 250
Elegance 270
Elegance 280
Nominal Heat Output kW
4.9 4.9 7 4.9 6 6 8
Flue Draught at Nominal Heat Output
mm Wg
1.5 1.5 1.5 1.5 1.5 1.5 1.5
Inch Wg
0.06 0.06 0.06 0.06 0.06 0.06 0.06
Flue Gas Mass Flow g/s
6.3 6.3 6.3 6.8 6.8 6.8 7.4
Flue Gas Temperature at Spigot/Socket
°C
290 290 290 290 290 290 270
Flue Outlet Size
mm
150 150 150 150 150 150 150
inch
6 6 6 6 6 6 6
Flue Position
Top
Only
Top
Only
Top
Only
Top
Only
Top
Only
Top
Only
Top
Only
Weight kg
76 81 85 75 90 103 155
Recommended Fuels
Wood
Seasoned wood (less than 20% moisture content).
Solid Fuel
Briquette smokeless fuel suitable for closed appliances.
(Ancit - Phurnacite - T
aybrite - Homefire Ovals).
Page 6
SITE REQUIREMENTS
B
efore installation of this product please read these
i
nstructions fully.
It is very important to also understand the requirements o
f the UK Building Regulations (England and Wales -
D
ocument J / Scotland - Part F), along with any local
r
egulations and working practices that may apply. Should any conflict occur between these instructions and these regulations then the regulations shall apply.
All electrical connections should meet the requirements of UK Building Regulations (England and Wales ­Document P / Scotland - Part N).
Your local Building Control Office would be happy to advise, should questions arise regarding the requirements of the regulations.
T
he Elegance Stove should be fitted by a HETAS (GB
o
nly) registered installer, or approved by your local building control officer. Your Yeoman dealer should be able to arrange this service for you.
Y
our building insurance company may also require you to i
nform them that you have installed a new heating appliance, so check with your insurers that your cover is still valid after installing the Elegance Stove.
When completing the installation and building works you should comply with your responsibilities under the Health and Safety at Work Acts, and any new regulations, which may be introduced during the lifetime of these instructions.
A faulty installation could cause danger to the inhabitants and structure of the building.
6
ELEGANCE STOVE DIMENSIONS
Elegance 200
Elegance 210
Elegance 220
Elegance 240
Page 7
SITE REQUIREMENTS
7
Elegance 250
Elegance 270
Elegance 280
Page 8
SITE REQUIREMENTS
8
A
dditional information covering the installation of the
E
legance stove may be found in the British Standard:
BS8303.
HEARTH DIMENSIONS
The appliance must stand on a constructional hearth with the minimum dimensions as shown in diagram b
elow.
If you are fitting the appliance into an existing hearth setting, check that it complies with the current construction regulations and is at least the minimum sizes shown.
If you have no existing fireplace or chimney, it is possible to construct a suitable non-combustible housing and hearth setting. However this should be constructed to comply with the requirements of both current national and local regulations with the design approved by your local building control officer
. Masonry chimney systems built with clay or concrete liners or pre-fabricated block systems should be constructed in accordance with B
S
6461 : Part 1. F
actory made insulated systems should comply with BS 4543 : Part 2 and be installed to BS 7566 : Parts 1 to 4.
Remember that any new chimney added to your property may also require planning permission.
WALLS ADJACENT TO HEARTHS
Location of hearth or Elegance Stove
Where the hearth abuts a wall and the Elegance Stove is not more than 50mm from the wall
Where the hearth abuts a wall and the Elegance Stove is more than 50mm but not more than 300mm from the wall
Where the hearth does not abut a wall and is no more than 150mm from the wall
Thickness (W)
200mm
75mm
75mm
Height (A)
At least 300mm above the Elegance Stove and 1200mm above the hearth
At least 300mm above the Elegance Stove and 1200mm above the hearth
A
t least 300mm
above the hearth
Solid, non-combustible material
Note: there is no requirement for protection of
the wall where C is more than 150mm
Yeoman Elegance
Wall Thickness W
Solid, non combustable m
aterial e.g concrete or
m
asonry
150mm
minimum
150mm
minimum
A
C
C
1
50mm minimum
Constructional hearth 840mm
m
inimum
Constructional
h
earth 840mm
minimum
Change in level to
mark safe perimeter
225mm
m
inimum
150mm
minimum
1
50mm minimum
Page 9
PRE-INSTALLATION CHECKS
9
I
t is important that adequate ventilation exists and the
f
lue or chimney system that is to be used is in good working condition. Products of combustion that enter the room could be a serious health risk. Before installation of this product we recommend that the flue or chimney system and ventilation requirements are inspected by a competent person, and passed as suitable for use with the appliance to be fitted. In particular the following should b
e checked: -
1. Flue or Chimney
1.1 The construction of the flue or chimney system should meet the requirements of the Building Regulations with sizes as shown: -
1.2 An approved, factory made system suitable for solid fuel use, complying with B
S 4543: P
art 2, may be used when installed to the requirements of BS 7566: Parts 1 to 4, the manufacturer’s instructions and the requirements of Building Regulations.
1.3 New masonry chimney systems built with clay or concrete liners or pre-fabricated block systems should be constructed in accordance with BS 6461 : Part 1, and the requirements of Building Regulations, may be used.
1.4 A flexible flue liner system may be used, if it is independently certified for use with solid fuel systems, and is installed according to the manufacturer’s instructions and the requirements of Building Regulations. If an appliance is being replaced on an e
xisting flexible flue liner system, the liner system should be replaced, unless it can be proved to be recently installed and can be seen to be in good condition.
1
.5 The flue exit from the building should be positioned to
c
omply with the requirements of the Building
Regulations.
1
.6 Any existing flue should be confirmed as suitable for the
n
ew intended use, as defined in the Building Regulations.
1.7 Any existing flue or chimney system must be inspected and swept by a NACS registered (GB only) chimney sweep, to confirm that the system is structurally sound and free from any obstructions.
1.8 Suitable access should be provided to enable the collection and removal of debris.
1.9 Provision should be made to sweep and inspect the flue when the appliance is installed.
1.10 No other heating appliances should be connected to, or share, the same flue or chimney system.
1.11 Check the flue draught. This should be done with all windows and doors closed and any e
xtraction fans in this
or adjoining rooms running at maximum speed (see ne
xt
section for additional ventilation requirements).
Note: A guide containing general information on chimneys and flues is obtainable from: -
The British Flue & Chimney Manufacturers’ Association, FETA
2 W
altham Court, Milley Lane Hare Hatch, Reading Bucks RG10 9TH
Tel : - 01189 403416 e-mail :- info@feta.co.uk
Model
Elegance 200
Elegance 210
Elegance 220
Elegance 240
Elegance 250
Elegance 270
Elegance 280
Flue/Chimney Size
Without liner system
Round (diameter)
mm
150 150 150 150 150 150 150
inch
6 6 6 6 6 6 6
Without liner
system Square
(minimum dimension).
mm
135 135 135 135 135 135 135
inch
5.5 5.5 5.5 5.5 5.5 5.5 5.5
With liner or factory
made system (diameter).
Installed in accordance with
manufacturer’s instructions
mm
150 150 150 150 150 150 150
inch
6 6 6 6 6 6 6
Flue/Chimney
minimum height*
m
4 4 4 4 4 4 4
feet
13 13 13 13 13 13 13
* When measured from the top of the stove to the top of the flue,
with no horizontal sections and a maximum of four bends with an angle of less than 45°
Page 10
PRE-INSTALLATION CHECKS
10
1
.12 Where a hearth, fireplace, flue or chimney is provided or
e
xtended (including cases where a flue is provided as part of refurbishment work), information essential to the correct appliance and use of these should be permanently posted in the building, to meet Requirement J4 of the Building Regulations (England and Wales), F3.12 (Scotland).
2. ADDITIONAL VENTILATION
2.1 Additional ventilation will be required to comply with the requirements of the Building Regulations. This should be provided using a permanently open air vent, of the size listed, which is positioned so that it is not liable to be blocked both inside and outside the building.
2.2 Extractor fans or cooker hoods should not be placed in the same room or space as the appliance.
2.3 If any of these checks reveal problems, do not proceed with the fitting of the appliance until they have been rectified.
Model
Elegance 200
Elegance 210
Elegance 220
Elegance 240
Elegance 250
Elegance 270
Elegance 280
Additional Ventilation
mm
none none 1100 none 550 550 1650
cm
- - 11 - 5.5 5.5 16.5
sq. inch
- - 4.33 - 2.17 2.17 6.50
Page 11
INSTALLATION INSTRUCTIONS
11
B
ecause each installation is unique to the property, it is
n
ot possible to give full details to suit every setting. However the installation should comply with the requirements of the Building Regulations and be made using ‘best practice’ construction methods.
R
emember that many fireplace openings will have a supporting lintel. Do not remove this without making provision to support the remaining structure of the building. The Elegance stove must not form any part of the supporting structure.
1. INSTALLING THE STOVE
1.1 Remove all packing and temporary transportation fixings from the Elegance stove, check that no parts have been left in the ashpan.
1.2 Lift the stove into position on the prepared hearth area, taking care not to damage the hearth finish.
1.3
Connect the stove to the chimney system, using Stovax enamelled flue pipe and seal the connecting joints. Typical top and rear flue connections are shown.
1.4 Top flue pipe installation
1.5
Connect a flue pipe by inserting it into the flue spigot and sealing using fire cement.
1
.6 Typical top flue installation. Flue to be installed in
a
ccordance with manufacture’s instructions.
1.7 As it is not possible to fully sweep the flue through the stove, provision must be made to clean the flue and collect debris without removing the stove.
Seal Collar with Fire Cement
Flue Pipe 915mm (3ft)
Size Stovax Part No
5” 4502 6” 4602
F
lue Pipe 915mm (3ft)
S
ize Stovax Part No
5
4502
6
4602
1
35° Elbow
S
ize Stovax Part No
5
4512
6
4612
T
o chimney connection as
d
etailed in building regulations
600mm m
inimum
1000mm maximum u
n-supported
Page 12
INSTALLATION INSTRUCTIONS
12
2. COMMISSIONING
2.1 Before lighting the Elegance stove, check the following items: -
a) Fit of internal parts (firegrate, firebricks, baffles, and
fuel retainer).
b
) Door alignment, seals and catch operation.
c
) Operation of air controls.
2.2 If there are any problems with the fit or operation of any of these items, this should be corrected before continuing with the commissioning of the Elegance s
tove.
2.3 Carry out a final smoke draw test, by first warming the f
lue with a blowlamp, or similar, for about 10 minutes. Then place a smoke pellet on the centre of the grate, with the air controls open, and close the door. Smoke should now be drawn up the flue and be seen to exit from the flue terminal. This test should be completed with all doors and windows in the room where the stove is fitted closed. Should this test fail, the suitability of the flue system and ventilation should be re-checked.
2.4 Light the appliance and gently allow the temperature to increase slowly to operating levels. Check that no combustion products are entering the room. When the stove has reached a steady operating condition open the main firedoor and carry out a spillage test with a smoke match or pellet around the door opening.
2.5 If excessive spillage does occur, allow the appliance to cool and re-check the suitability of the flue system and ventilation.
2.6 Explain the safe operation of the stove and the use of the controls to the user, along with the need to only use suitable fuels. Also explain the cleaning and routine maintenance requirements.
2.7 Explain the requirements to use a suitable fireguard when children, elderly or infirm persons may be near the appliance.
2.8 Record dealer/supplier details and installer details in user instructions.
2.9 Record serial number in user instructions.
This number will be required when ordering spare parts and making warranty claims.
2.10 Give the copy of the user instructions to the customer
.
Page 13
OPERATING INSTRUCTIONS
1. GENERAL
1.1 This stove is designed for domestic heating and should
only be used for this purpose, and in accordance with the manufacturer’s operating instructions.
1.2 It should be installed by a competent installer (HETAS
registered GB only), in accordance with all local regulations, including those referring to national and European standards.
1.3 The stove should only be used to burn approved fuels
and should not be used with liquid fuels or used as an incinerator.
1.4 As with all heating stoves, the surfaces will become very
hot when in use, therefore due care should be taken when near the stove. If it is to be used in the presence of young children, elderly or infirm persons a suitable fireguard should be used. Care should also be taken with the placement of combustible items near the stove as conducted and radiated heat could cause a fire hazard.
Stovax offer a wide range of firescreens and sparkguards, along with a hearthgate system designed to offer full protection for a range of stoves and fireplaces. Your Stovax dealer can advise you on these products.
1.5 The additional ventilation required for the safe use of this
stove should be kept free of any obstructions, both inside and outside the building, at all times.
1.6 Have your Stovax product serviced annually by a
competent service engineer, and if repairs are required use only Stovax approved spare parts.
1.7 Do not make unauthorised modifications or changes to
the stove.
1.8 SERIAL NUMBER This number will be required when
ordering spare parts or making warranty claims.
1.9 AIR CONTROLS (typical layout)
2. USING THE STOVE FOR THE FIRST TIME
2.1 When new, it is best to burn the fire at a low output for the first few days of use. This will allow the construction to settle and all fixing glues and paint to fully cure.
2.2 Avoid touching the paint during the first period of use.
2
.3 During this time the stove may give off some unpleasant
o
dours, and we recommend that you keep the room well
ventilated during this period to avoid a build-up of fumes.
3. BURNING WOOD
3.1 Open the Airwash control fully and open the Primary air control
to approximately 25% open.
3.2 Place some pieces of firelighter or dry crumpled paper on the grate and cover with some small pieces of dry kindling wood. Light the paper or firelighters.
3.3 To avoid the build-up of condensation on the door glass it is advisable to leave the door slightly open as the fire establishes and the glass warms.
3.4 As the fire becomes established add larger pieces of wood and fully close the door.
Do not leave the stove with the door open as this could over-fire the stove and cause permanent damage.
3.5 As the fire becomes established, close the Primary air
control
and control the burn rate using the Airwash
control
only.
3.6 To burn wood efficiently it is best to allow a bed of ash to build-up on the grate, or the base of the stove, and control the combustion using the
Airwash control only.
3.7 Before re-fuelling the stove it is advisable to first rake the embers evenly over the firebed then open the
Airwash
control
fully for a few minutes, to establish a glowing bed
before adding new logs.
3.8 Allow the new logs to burn at high output for a few minutes before adjusting the burn rate, with the
Airwash
control
, to the desired setting. It is best to refuel little
and often to maintain clean and efficient burning
.
3.9 The ideal control settings to suit the particular installation and personal preferences will be established by experience in using the stove.
3.10 It is not recommended to load large amounts of logs and burn with the Airwash control on low settings for long periods of time as this will reduce the effectiveness of the glass cleaning effect of the airwash. Also this will cause large a build-up of tars and creosotes in the stove and flue system.
AIRWASH
CONTROL
Above door
PRIMARY AIR
CONTROL
On door
See instructions for
detailed use of
controls
13
Page 14
OPERATING INSTRUCTIONS
14
3
.11 We would recommend that the stove be burnt at high
o
utput for at least 30 minutes each day when it is in use. This will help reduce the build-up of tars and creosotes within the stove and flue system.
3
.14 Do not burn painted or impregnated wood,
m
anufactured board products, pallet wood or scrap
timber.
4. BURNING SOLID FUEL
4.1 Open the Airwash control to approximately 50% and Primary air control fully.
4.2 Place some pieces of firelighter or dry crumpled paper on the grate and cover with some small pieces of dry kindling wood. Light the paper or firelighters.
4.3 To avoid the build-up of condensation on the door glass it is advisable to leave the door slightly open as the fire establishes and the glass warms.
4.4 As the fire becomes established add pieces of solid fuel and fully close the door.
Do not leave the stove with the door open as this could over-fire the stove and cause permanent damage.
4.5 As the fire becomes established, reduce the Airwash air
control
to approximately 25% and control the burn rate
using the
Primary air control only.
4.6 To burn solid fuel efficiently it is best to control the combustion using the
Primary air control only.
4.7 Before re-fuelling the stove it is advisable to first de-ash the firebed, using the riddling grate system (if fitted) or a suitable poker.
Do not use bare hands to operate the
riddling system or if using a poker to clear the firebed.
4.8 Then open the Primary air control fully for a few minutes, to establish a glowing bed before adding new fuel. Allow the new fuel to burn at high output for a few minutes before adjusting the burn rate with the
Primary
air control
to the desired setting. It is best to refuel little
and often to maintain clean and efficient burning.
4.9 The ideal control settings to suit the particular installation and personal preferences will be established by experience in using the stove.
4.10 We would recommend that the stove be burnt at high output for at least 30 minutes each day when it is in use. This will help reduce the build-up of tars and creosotes within the stove and flue system.
4.11 Do not burn bituminous coal, ‘petro
-
cok
e’ or other petroleum based fuels, as this will invalidate the product guarantee.
O
VER-FIRING
4.12 Do not use the appliance at maximum output for prolonged periods of time, or over fill the firebox with f
uel, as this could result in over-firing. If the connecting
f
luepipe, appliance flue collar or top plate glow red with
h
eat the appliance is being over-fired and the air controls
should be closed to reduce the output.
4.13 If a chimney fire occurs shut all air controls immediately to close the appliance down, and evacuate all persons from the building before calling the fire brigade. Do not re-enter the building until it is confirmed safe to do so.
4.14 Following a chimney fire do not use the appliance until it is inspected, by a HETAS (GB only) registered installer, to confirm that the appliance is safe to use, or make any repairs required before re-use. Only genuine Stovax replacement parts are to be used to keep your appliance in safe and efficient working order
.
4.15 After any chimney fire it is recommended that the chimney system be inspected and swept by a NACS registered (UK only) chimney sweep, to confirm that the system is structurally sound and free from any obstructions before re-use.
SEASONAL USE
4.16 If the stove is not to be used during the warmer periods of the year it is recommended to clean and service the stove, as detailed in the maintenance and servicing section of this booklet.
4.17 The air controls should be set in the 50% open position to keep the appliance ventilated, and stop the build-up of any moisture inside.
4.18 Before re-lighting the stove remove the baffles, clear any debris that may have accumulated, and check the flue is clear of any block
ages.
5. ASH REMOVAL
5.1 The burning of any fuel will produce ash, which will have to be removed after a period of use. This time will depend on the fuel used. Before removing the ash from the stove it is advisable to let the fire burn down to a low level, or even go out completely
. The ashpan can be removed
from the stove after opening the door
.
5.2
As heat can remain in the ash for a long period after use care must be tak
en when removing and carrying the full ashpan. We suggest that the ashpan be carried using gloved hands, or the ash is placed directly into a Stovax Ash Caddie.
Page 15
OPERATING INSTRUCTIONS
15
5
.3 When burning wood the amount of ash will be smaller
a
nd may only need removal once every week. To do this, allow the fire to burn out and cool. Then after removing the log retainer scoop out the ash with a suitable shovel. It is best to leave a layer of ash in the stove to form a bed for the new fire.
5.4 Do not place ash in a bin made from plastic or any other combustible material.
6. RECOMMENDED FUELS
6.1 Wood: - Burn only seasoned timber, with a moisture content of less than 20%. In most cases, this would require drying cut wood for at least 12 to 18 months before use. Poor quality timber could cause low combustion efficiency and produce large amounts of harmful condensation, which could reduce the effectiveness of the airwash system, and ultimately the life of the stove.
6.2 Do not burn painted or impregnated wood or manufactured board products.
The symptoms of poor performance related to wet wood include: -
difficulty getting a fire going and keeping it burning well
smoky fires with little flame
dirty glass
rapid creosote build-up in the chimney
low heat output
short burn times, excessive fuel consumption and blue/grey smoke from the chimney.
6.3 To help avoid large build-ups of tars and creosote within in the stove and the flue system, it is recommended to burn at maximum output for at least 30 minutes each day
. The use of Stovax Protector chimney cleaner will
also help to reduce this problem.
6.4
Solid fuel: - Burn manufactured smok
eless fuels, listed as suitable for use with closed heating stoves. Do not burn bituminous coal, ‘petro-
cok
e’ or other petroleum based
fuels, as this will invalidate the product guarantee.
6.5 If you require advice on suitable solid fuels contact your local Approved Coal Merchant. Details can be obtained by ringing the Solid fuel Association advice line on Freephone 0800 600 000, or their web site at www
.solidfuel.co.uk
Page 16
MAINTENANCE AND SERVICING
16
1. GENERAL CLEANING
1.1 We would recommend that your Elegance stove be cleaned fully on a regular basis, according to the level of use. Attention should be given to cleaning the baffle system, flueways and removing ash. Regular cleaning and preventive maintenance will help give many years of safe use.
1.2 The external paintwork may be cleaned using warm soapy water and a soft clean cloth. Wipe dry with a soft c
lean cloth before re-lighting. Do not leave unit without
d
rying, as this may cause rust.
2. CLEANING GLASS
2.1 While the correct use of the Airwash system, and good quality fuel, will generally keep the glass clean when the appliance is used you may sometimes need to clean the glass.
2.2 This can be done as follows. Allow the Elegance stove to cool fully, never attempt to clean hot glass. Any deposits can then be removed using a soft cloth and Stovax Glass Cleaner.
2.3 Before re-lighting the appliance, dry the glass fully.
2.4 Do not use abrasive cleaner or cleaning pads.
3. CHIMNEY SWEEPING
3.1 We would recommend that to maintain the safe and efficient use of the appliance the flue / chimney is inspected and swept at least once a year, by a NACS registered (UK only) chimney sweep, to confirm that the system is clean, structurally sound and free from any obstructions.
4. ANNUAL SERVICE
4.1 At the end of the heating season it is recommended to strip, inspect and clean the stove as detailed: -
4.2 Carefully remove all of the following internal parts. Internal Baffle, Firebricks, Complete grate, Ashpan, and V
acuum clean any remaining ash and debris from the
inside of the stove.
4.3 Clean the internal, metal, surfaces of the stove a using a wire brush and scraper as required and vacuum and brush the resulting debris from the stove.
4.4 Clean the Grate parts with a wire brush, check for any damage and replace any damaged parts as required.
4.5 Check and clean, with a soft brush the Firebricks. Replace any broken bricks. It is normal for some surface damage to occur during use.
4
.6 Re-fit cleaned internal parts.
4.7 Remove the glass from the door, and discard all old rope seals.
4.8 Remove the door rope seal from the outer edge of the door clean the old glue from the door sealing rope grove.
4.9 Clean the door glass using Stovax Stove Glass cleaner and a soft cloth. Do not use abrasive cleaners to remove t
ar or soot deposits from the glass.
4.10 Replace the glass edge seal with new and re-fit the glass into place in the door.
4.11 Fit new door rope seal, gluing it in place with Stovax Thermic Seal rope adhesive. When fitting new door seals we recommend closing the stove door and leaving for at least 12 hours before using. This allows the adhesive to fully bond to the seal before use.
4.12 Lightly oil the door catch mechanism and hinge pins. Avoid getting oil on to the door seals, glass and paintwork.
4.13 To refresh painted finishes it is possible to re-paint using Stovax Thermolac stove paint.
4.14 We recommend that only genuine Stovax replacement parts are use to keep your appliance in safe and efficient working order. Your local Stovax dealer will be able to provide you with the genuine parts you require.
4.15 When using the stove for the first time again it is best to burn the fire at a low output for the first day of use. This will allow the new seals to settle and all new fixing glues and paint to fully cure.
4.16 During this time, the stove may give off some unpleasant odours, and we recommend that you keep the room well ventilated during this period to avoid a build-up of fumes.
4.17 If you require help, your local Y
eoman dealer will be able to carryout all of your service and maintenance requirements for a reasonable cost.
Page 17
SPARE PARTS LIST
Elegance 200
17
Part No. Item Description Part No. Item Description
1 Stove body 183792 12 Glass pane curved 280x260 183793 2 Door - anthracite 183791 13 Deflection plate 420x145x19 183799 3 Ash pan 183795 14 Cover plate
4 W
ood storage compartment
183802 15 Door spring
5 Flue spigot 181938 16 Secondary air control (Airwash)
See detail list*
6 Firebrick 183949 17 Support deflection plate 180492 7 Grate 183950 18 Guard plate
8 183786 *181 Firebrick 300x300x30 183790 9 Log Guard 183787 *202 Firebrick 153x40x30 183963 10 Door Handle 183788 *205 Firebrick 345x60x30 181938 11 Primary air control 183789 *206 Firebrick 300x200x30
Page 18
SPARE PARTS LIST
Elegance 210
18
Part No. Item Description Part No. Item Description
1 Stove body 183792 12 Glass pane curved 280x260 183793 2 Door - anthracite 183791 13 Deflection plate 420x145x19 183799 3 Ash pan 183795 14 Cover plate
4 W
ood storage compartment
183802 15 Door spring
5 Flue spigot 181938 16 Secondary air control (Airwash)
See detail list*
6 Firebrick 183949 17 Support deflection plate 180492 7 Grate 183950 18 Guard plate
0065000015000
8 Warming compartment insert plate 183786 *181 Firebrick 300x300x30 183790 9 Log Guard 183787 *202 Firebrick 153x40x30 183963 10 Door Handle 183788 *205 Firebrick 345x60x30 181938 11 Primary air control 183789 *206 Firebrick 300x200x30
Page 19
SPARE PARTS LIST
Elegance 220
19
Part No. Item Description Part No. Item Description
1 Stove body 183792 12 Glass pane curved 280x260 183793 2 Door - anthracite 183791 13 Deflection plate 420x145x19 183799 3 Ash pan 14 Cover plate
4 W
ood storage compartment
183802 15 Door spring
5 Flue spigot 181938 16 Secondary air control (Airwash)*
See detail list*
6 Firebrick 183949 17 Support deflection plate 180492 7 Grate 183950 18 Guard plate
8 183786 *181 Firebrick 300x300x30 183790 9 Log Guard 183787 *202 Firebrick 153x40x30 183963 10 Door Handle 183788 *205 Firebrick 345x60x30 181938 11 Primary air control 183789 *206 Firebrick 300x200x30
Page 20
SPARE PARTS LIST
Elegance 240
20
Part No. Item Description Part No. Item Description
1 Stove body 181324 11 Glass curved 340x280 182554 2 Door - anthracite 183127 12 Baffle 430x210 181338 3 Ash pan 183128 13 Cover plate
4 Wood storage compartment 182557 14 Door spring
5 Flue spigot 182558 15 Door bolt
See detail list*
6 F
irebrick
16 Secondary air control (Airwash)* 180492 7 Grate 1825593 *163 Firebrick 260x62x30 181341 8 Log Guard 1825603 *164 Firebrick 275x60x30 182556 9 Door Handle 1825613 *165 Firebrick 280x250x30 181938 10 Primary air control 182623 *166 Firebrick 280x220x30
Page 21
SPARE PARTS LIST
Elegance 250
21
Part No. Item Description Part No. Item Description
1 Stove body 181938 11 Primary air control 183761 2 Door - anthracite 183765 13 Baffle 420x145x19 181338 3 Ash pan 183766 14 Baffle 420x80x19
4 Wood storage compartment 183767 15 Cover plate
5 Flue spigot 182557 16 Door spring
See detail list*
6 F
irebrick
17 Secondary air control (Airwash) 180492 7 Grate 1825593 *163 Firebrick 260x62x30 183762 8 Warming compartment insert plate 1825603 *164 Firebrick 275x60x30 183763 9 Log Guard 1825623 *166 Firebrick 280x220x30 183764 10 Door Handle 183768 *200 Firebrick 330x250x30
Page 22
SPARE PARTS LIST
Elegance 270
22
Part No. Item Description Part No. Item Description
1 Stove body 183765 13 Baffle rear 420x145x19 183761 2 Door - silver painted 183766 14 Baffle front 420x80x19 181338 3 Ash pan 183769 15 Top cover (silver)
4 Wood log compartment 182557 16 Spring (door)
5 Flue spigot 17 Secondary air control (Airwash)
See detail list*
6 Firebrick 183770 18 Side panel (silver) 180492 7 Grate 196914 Seal - door 8mm 183762 8 W
arming shelf inlay (silver)
196917 Seal glass pane 10x4mm 183763 9 Log Guard 1825593 *163 Firebrick 260x62x30 183764 10 Door Handle 1825603 *164 Firebrick 275x60x30 181938 11 Primary air control 1825623 *166 Firebrick 280x220x30 181984 12 Glass pane 370x340 183768 *200 Firebrick 330x250x30
Page 23
SPARE PARTS LIST
Elegance 280
23
Part No. Item Description Part No. Item Description
1 Stove body 182659 17 Lower baffle 385x290
183953 2 Door 181954 18 Base support framework
3 Warming shelf 183452 19 Side panel left 4 Wood log compartment 183453 20 Side panel right
183450 5 Ash pan 340x320 183454 21 T
op cover steel sheet
6 Flue spigot 196912 Seal door 10mm
See detail list*
7 Firebrick 196915 Seal glass
182641 8 W
arming shelf inlay ST
181353 *105 F
irebrick 173x97x30 180492 9 Grate 181354 *106 Firebrick 260x123x30 182654 10 Log retainer 181355 *107 Firebrick 276x45x30 181930 11 Door handle 181977 *152 F
irebrick 480x165x30 181938 12 Primary air control 181978 *153 Firebrick 480x165x30 181938 14 Secondary air control (Airwash) 182227 *158 Firebrick 370x120x30 182655 15 Glass pane 465x370 flat 182656 *174 Firebrick 360x220x30 181361 16 Upper baffle 375x160 183471 *191 Firebrick 425x115x30
Page 24
YEOMAN STOVES
A division of Stovax Ltd
Falcon Road, Sowton Industrial Estate, Exeter, EX2 7LF
Tel 01392 474500 Fax 01392 219932
www.yeoman-stoves.co.uk
Email: yeoman@stovax.com
Loading...