For use in GB & IE (Great Britain and Republic of Ireland).
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated
instructions and in some cases the appliance will require modification. Contact Stovax for further information.
IMPORTANT
This appliance will become hot whilst in operation, it is therefore recommended that a suitable guard should be used for the
protection of young children, the elderly or infirm. Do not attempt to burn rubbish in this appliance.
Please read these Instructions carefully before installation or use.
Keep them in a safe place for future reference and when servicing the fire.
The commissioning sheet found on page 3 of these instructions should be completed by the Installer.
PM302 Issue 4 (October 2010)
CONTENTS
COVERING THE FOLLOWING MODELS:
YEOMAN DEVON/COUNTY 60/COUNTY 80
APPLIANCE COMMISSIONING CHECKLIST 3
USER INSTRUCTIONS 4
General Points 4
Heating Controls 5
Using the Appliance for the first time 6
Condensation 6
Recommended Fuels 6
Lighting the appliance 7
Running the appliance 7
Burning Tips 9
Ash Removal 10
Wood Burning Tray 10
Extended burning 11
Over-Firing 11
Chimney Fire 11
General Cleaning 12
Cleaning Glass 12
Chimney Sweeping 12
Care of Stove 12
Seasonal Use 13
Troubleshooting Tips 13
COMMISSIONING 30
MAINTENANCE & SERVICING 31
Annual Service 31
Removal of Log Guard 32
Removal of Baffle 32
Removal of Riddling grate 32
Fitting a New Door Glass 32
Fitting a New Door Seal 32
Adjusting Door Hinges 33
Adjusting Door Catch 33
BASIC SPARE PARTS LIST 34
SERVICE RECORDS 38
INSTALLATION INSTRUCTIONS 14
Technical Specifications 14
Boiler output charts 15
Standard Features 15
Packing List 15
Dimensions 16
SITE REQUIREMENTS 17
Flue & Chimney 17
Flue outlet positions 18
Hearth Dimensions 18
Walls Next to Hearth 19
PRE-INSTALLATION 20
Flues 20
Ventilation 21
INSTALLATION 22
Legal Requirements 22
Installing the Appliance 22
Top Flue Installation 22
Rear Flue Installation 23
Removal of Log Guard 24
Fitting & Removal of Baffle 24
Fitting & Removal of Multi-fuel grate 25
Central Heating System 26
Conventional pipe work system 27
Heating system controls 29
Link up system 29
w a r r a n t y
Your Yeoman retailer provides you with a Two Year Warranty
for your new stove. However, this specifically excludes naturally
wearing parts or consumables such glass, firebricks and rope
seal and the use of non-authorized fuel such as petro-cokes.
Furthermore, for the warranty to be valid, your stove must have
been installed in accordance with the manufacturer’s instructions
and the second year’s warranty is dependent on the appliance
being serviced 12 months after installation by a HETAS or other
similarly qualified engineer.
They also provide a Five Year Casting Warranty for the carcass of
all cast iron stoves and the cast iron door of steel stoves. Again, this
excludes naturally wearing cast parts such as grate, dampers, log
retainers and baffles.
You can help your retailer to provide their warranties by returning
the reply card or registering online at yeoman-stoves.co.uk.
2
APPLIANCE COMMISSIONING CHECKLIST
To assist us in any guarantee claim please complete the following information.
In the unlikely event of a problem, contact your installer or retailer for assistance:
Date installed: .....................................................................................................................................................
Model Description: ..............................................................................................................................................
Serial number: .....................................................................................................................................................
Installation Engineer
Company name: .....................................................................................................................................................................
1.1 Before use of this appliance please read these
instructions fully.
The appliance must be fitted by a registered installer* or
approved by your local building control officer.
1.2All local regulations, including those referring to national
and European Standards need to be complied with when
installing the appliance.
1.3 Only use for domestic heating. To achieve the optimum
performance from this appliance it must be installed and
operated according to these instructions burning the fuels
recommended.
1.4 You must burn only approved fuels. Do not use with liquid
fuels or as an incinerator.
1.5 Appliance surfaces become very hot when in use. Use
a suitable fireguard if young children, elderly or infirm
persons are present. Stovax offer firescreens, sparkguards
and hearthgate systems for protection‡. Your Yeoman
retailer can advise you about these products.
1.6 Do not place photographs, TV’s, paintings, porcelain or
other combustible items on the wall or near the appliance.
Exposure to hot temperatures will cause damage. Do not
place furniture, or other items such as drying clothing,
closer than 1m from the front of this appliance.
1
Data Plate
PR7517
THERMOSTAT
The stove is controlled by a thermostat which regulates
the rate in which the fuel is burned and the amount of
heat produced. A trial and error approach will establish
settings to suit personal preference.
AIR CONTROLS
Several Yeoman appliances have air systems providing
cleaner burning, and greater efficiency and control:
1) Airwash - air drawn over the window cleans the glass.
The source of Primary Combustion air when burning wood.
1.7 Extractor fans or cooker hoods must not be placed in the
same room or space as this can cause appliance to emit
fumes into the room.
1.8 Do not obstruct inside or outside ventilation required for
the safe use of this appliance.
1.9 Do not make unauthorised changes to the appliance.
1.10 The chimney must be swept at least once a year (see
Section 12).
1.11 Do not connect, or share, the same flue or chimney
system with another appliance.
1.12 Do not run the appliance without any water in the
system.
SERIAL NUMBER
1.13 This number is required when ordering spare parts or
making warranty claims. It is found on the appliance data
plate.
All models
For all models the data plate is found under the front of the
stove ashlip (see Diagram 1).
2) Primary Air - for use with solid fuel and when lighting
wood fires.
‡
In the U.K. these products must conform to BS 6539,
Fireguards for use with solid fuel appliances.
If appliance is operating unattended they must conform to
BS 3248
*Registered on the Competent Persons Scheme (GB only)
see page 14 / INFO (Republic of Ireland).
4
USER INSTRUCTIONS
AIRWASH & PRIMARY AIR CONTROLS
1.14 Use a gloved hand to operate air controls.
Airwash Control
OpenClose
Primary Air Control
Primary Control
OpenCloseOpen
DOOR HANDLE
1.15 Use a protected gloved hand to operate.
DO NOT OPEN THE DOOR WITH BARE HANDS
To Open and Close
Drop door tool over knob to fit.
1
/2 turn anti-clockwise to open.
Rotate
1
/2 turn clockwise to close.
Rotate
Lift up door tool to remove
Airwash Control
PR7519
HEATING SYSTEM CONTROLS
CONTROLS, GENERAL
1.18 The controls fitted to the system will provide two functions:
—To control the comfort level in the house.
—To maintain safety in the event of misuse or mechanical
failure.
COMFORT CONTROLS
1.19 A programmable timer switches the pump on when heat is
required and off when it is not.
The timer, when combined with a room thermostat and / or
thermostatic radiator valves, enhances the comfort levels in
the house.
Some room thermostats combine the function with
the timer and can be programmed to reduce the room
temperature rather than turning the system off. This is
effective in not allowing rooms to become too cold and
speeding up recovery time.
1.20 The hot water cylinder can also be fitted with a thermostatic
valve which turns off the flow when the cylinder has
reached the desired temperature, but the heat leak radiator
will have to be bigger to cope with the extra load when the
tank is isolated.
SAFETY CONTROLS
1.21 A high limit thermostat is fitted to the gravity flow pipe set
at 80˚C. This thermostat should be connected to the pump
so that the pump is turned on if the temperature exceeds
80˚C. This will prevent accidental boiling in the gravity
circuit.
1.22 It is also recommended to fit a low limit thermostat on the
central heating return set at 45˚C. This thermostat will turn
the pump off if the return temperature falls below 45C. This
will prevent corrosion and condensation within the stove.
1.16 Never open the door with your bare hands.
1.17 Closing the door is the reverse of the previous.
Open
PR7523
NOTE – Further information on solid fuel central heating
systems can be found in the HETAS engineers training
manual.
5
USER INSTRUCTIONS
WARNING
Properly installed, operated and maintained this
appliance will not emit fumes into the room.
Occasional fumes from de-ashing and refuelling may occur.
Persistent fume emission is potentially dangerous and
must not be tolerated.
If fume emission does persist:
—Open doors and windows to ventilate the room.
—Allow fire to burn out or safely dispose of fuel from the
appliance.
—Check for chimney blockage and clean if required.
—Do not attempt to relight until the cause of the emission
has been identified and corrected.
If necessary seek expert advice.
—All open flued appliances can be affected by
temporary atmospheric conditions which may
allow fumes to enter the house. Because of this it is
recommended that an electronic carbon monoxide
detector conforming to BSEN50291 be fitted and
maintained.
2. USING THE APPLIANCE FOR THE
FIRST TIME
2.1 To allow the appliance to settle and fixing glues and paint
to fully cure:
—Operate the appliance at a low temperature for first few
days.
2.6 Precautions must be taken to ensure that this build up of
condensate does not overflow from the appliance onto any
surrounding fabric of the room e.g. carpets.
NOTE - THIS CONDENSATION IS NORMAL DURING
FILLING AND DOES NOT INDICATE A FAULTY OR
LEAKING STOVE.
NORMAL RUNNING
2.7 During normal running this condensation should be minimal
if the system is fitted with the low limit thermostat as
detailed in 1.22 (above). This low limit thermostat prevents
the system pump from running until the stove has reached
temperature.
SEASONAL USE
2.8 If this appliance is unused for lengthy periods of time it
should be periodically checked to ensure that condensation
is not building up within the stove.
NOTE – THIS CONDENSATION IS NORMAL AND DOES
NOT INDICATE A FAULTY OR LEAKING STOVE.
If the stove is going to be unused for very long periods of
time it is recommended to drain the system.
3. RECOMMENDED FUELS
3.1 Wood Logs:
Burn only seasoned timber with a moisture content of less
than 20%. To ensure this allow cut wood to dry for 12 to
18 months.
2
Wood Length
2.2 Do not touch the paint during the first period of use.
2.3 During this time the appliance may give off some
unpleasant odours:
—Keep the room well ventilated to avoid a build-up of
fumes.
CONDENSATION
CAUTION WHEN FILLING
2.4 When filling the boiler with water for the first time, the cold
water entering the water jacket can cause condensation to
form on the surfaces of the appliance (inside and outside).
2.5 In certain conditions this condensation could result in a
considerable amount of water, in some cases enough to fill
the bottom of the appliance. This could be even worse if
the house has recently been re-decorated, wet plastered or
any other work has been undertaken which could result in
high humidity.
—Produces harmful condensation.
—Reduces effectiveness of the airwash and life of the
appliance.
Do not burn construction timber, painted, impregnated
/ treated wood, manufactured board products or pallet
wood.
6
USER INSTRUCTIONS
3.2 Solid fuel:
—Burn only anthracite or manufactured briquette
smokeless fuels listed as suitable for use with closed heating
appliances
Do not burn bituminous coal, ‘petro-coke’ or other
petroleum based fuels as this will invalidate the product
guarantee.
Fuel Consumption
Description
Yeoman Devon4.82.1
Yeoman County 605.53.2
Yeoman County 806.64.5
3.4 For advice on suitable solid fuels contact your local
approved coal merchant*.
A number of factors can affect the performance of the
appliance (see User Instructions, Section 6).
Kg/hour
Wood
Kg/hour
Briquette
Smokeless fuel
4. LIGHTING THE APPLIANCE
4
—Leave the door slightly open as the fire establishes and
the glass warms to avoid the build-up of condensation.
—Add larger pieces of solid fuel once the fire is established
Do not add too much fuel initially as this may smother
the fire.
Do not load fuel above the log guard (see Diagram 5).
5
4.1 For best results:
—Set air controls (see Diagram 3).
3
Primary Air: Fully Open
4.2 Fully open the Airwash control and the Primary air control.
—Place firelighters or paper and dry kindling wood on the
grate.
—Light the paper or firelighters (see Diagram 4).
Airwash: Fully Open
PR7519
Base of baffle
Log guard
—Close the door.
Do not leave the door open as this may cause over-firing
which can damage the appliance.
PR8872
5. RUNNING THE APPLIANCE
BURNING WOOD:
5.1This appliance gives out its heat in two ways:
—Directly into the room in which it is fitted through
convection and radiation.
—Hot water to heat radiators and domestic hot water. The
output to hot water varies depending on how
quickly the fuel is being burnt. Fore more detail see the
graph on page 15.
*In the U.K:
• Ring the Solid Fuel Association advice line on 0845 601
4406 for details
• Visit their web site at www.solidfuel.co.uk
5.2 Only for use with recommended fuels, see Section 3 for full
details.
—Close the Primary aircontrol and use the Airwash to
control the burn rate when the appliance is at optimum
operating temperature (see Diagrams 6 & 7).
7
USER INSTRUCTIONS
6
PR8855
7
Airwash: Fully Open
Do not burn construction timber, painted,
impregnated / treated wood, manufactured board
products or pallet wood.
BURNING SOLID FUEL
5.7 To burn smokeless fuels a cast iron multi-fuel kit must be
fitted. Set air controls as shown in Diagram 7.
5.8 De-ash the firebed before re-fuelling (see User Instructions, Section 7).
Open the Primary air control fully to establish a glowing
bed before adding new fuel.
Burn new fuel at a high temperature (see Diagram 6) for a
few minutes before adjusting the Primary air control to the
desired setting.
Refuel little and often for clean, efficient burning.
5.9 Experience establishes settings to suit personal preference.
5.10 Do not burn large amounts of fuel with the Primary air control on a low combustion setting for long periods of
time. This reduces the glass cleaning effect of the Airwash
and causes tars and creosotes to build-up in the appliance
and flue system.
Primary Air: Fully Open
—Wood burns best on a bed of ash (approx. 25mm (1")
deep).
—Rake the embers evenly over the firebed and open the
Airwash control fully for a few minutes before
re-fuelling.
Do not refuel when a large amount of flames are present
in the firebox as this could cause smoke or flames to
spill into the room.
Close the doors immediately after refuelling.
5.3 Burn new logs at a high temperature for a few minutes
before adjusting the Airwash control. Refuel little and often
for clean, efficient burning.
Do not load above the log guard or base of baffle.
5.4 Do not burn large amounts of fuel with the Airwash control
closed for long periods of time. This reduces the glass
cleaning effect of the Airwash and causes tars and creosotes
to build-up in the appliance and flue system.
5.5 When in use, running the appliance at a high temperature
for a short period reduces tars and creosotes.
5.6 Experience establishes settings to suit personal preference.
PR7519
5.11 When in use, burning the appliance at a high temperature
for a short period reduces tars and creosotes.
5.12 Only anthracite or smokeless fuels suitable for use in closed appliances must be burned in this appliance.
5.13 Do not burn bituminous coal, ‘petro-coke’ or other
petroleum based fuels as this invalidates the product
guarantee.
5.14 Do not load fuel above the log guard and the Secondary
Air Inlets at the back of the firebox (see Diagram 5).
REFUELLING
5.15 De-ash the fire bed before refuelling, see Ash Removal
—Open the Primary air control fully to establish a glowing
bed before adding new fuel.
—Do not refuel when a large amount of flame is
present in the firebox as this could cause smoke or
flames to spill into the room.
—Close the doors immediately after refuelling.
—Burn new fuel at a high temperature for a few minutes
before adjusting the Primary air control to the desired
setting.
—Refuel little and often for clean, efficient burning.
5.16 Do not re-fuel the stove above the level of the log guard or
the base of the baffle.
8
USER INSTRUCTIONS
THERMOSTAT OPERATION
5.17 This appliance can be fitted with a thermostat kit to control
the temperature of the boiler. See the instructions included
in the kit for operation details.
6. BURNING TIPS
6.1 Fuel Quality (Wood)
Use wood with a moisture content of less than 20%.
Seasoned logs have the bark beginning to lift and peel away
and cracks radiating from the centre. They feel lighter than
fresh cut wood of a similar size and sound hollow when
struck against each other. Logs should not feel damp or have
moss or fungal growths.
Symptoms related to wet wood:
—Difficulty starting and keeping a fire burning well.
—Smoke and small flames.
—Dirty glass.
—Rapid creosote build-up in the chimney.
—Low heat output.
—Short burn times, excessive fuel consumption and blue/
grey smoke from the chimney.
Burn at a high temperature for a short period each day
to avoid large build-ups of tars and creosotes within the
appliance and the flue system.
Symptoms of poor performance related to flue draught
—Wind noise from air controls (high flue draught).
—Difficulty getting a fire going and keeping it burning well
(low flue draught).
—Low heat output (low flue draught).
—Smoke entering room when doors are opened (low flue
draught).
The construction, position, size and height of the chimney
all affect the performance of the flue draught.
Other factors effecting the flue draught include:
—Nearby trees or buildings causing turbulence.
—Outside temperature.
—Outside weather conditions.
—Incorrect additional ventilation to building.
—Blocked flue or chimney.
For advice on the correction of persistent flue problems
consult a qualified heating engineer before continuing to
use the appliance.
6.5 Weather conditions
The weather conditions outside the building can effect the
burning performance of the appliance. These could include:
Use Stovax Protector chimney cleaner to reduce this
problem.
6.2 Fuel Quality (Solid Fuel)
Use recommended solid fuels approved for use with closed
appliances.
Symptoms related to unsuitable fuels include:
—Difficulty starting and keeping a fire burning well.
—Smoke and small flames.
—Dirty glass and/or fire bricks.
—Short life span for grate and baffle.
—Permanent staining of glass.
6.3 Air inlets puffing smoke
Combustion gases can build up in the firebox and ignite
as small explosions, causing smoke to puff out of the air
inlets and other openings. This occurs if the air controls
are shut soon after adding new fuel to a very hot fire. Stop
by opening the air controls to increase combustion air and
burning rate.
6.4 Flue Draught
The chimney has two main functions:
1) To safely remove the smoke, gases and fumes from the
house.
2) To provide a sufficient amount of draught (suction) in the
appliance ensuring the fire keeps burning.
Weather Conditions ProblemEffect
Windy days
Calm days
Damp / Rainy days
To reduce these problems:
—Use good quality kindling wood to start the fire.
—Burn initially at a high temperature for a short period.
—Fit a rain cowl to the chimney.
Your installer should advise you on possible solutions.
If the appliance emits smoke into the room continuously:
—Close the air controls and allow the appliance to go out.
—Ventilate the room to clear the fumes.
Do not re-light the appliance until the problem is solved.
Buildings/obstacles
cause turbulent air
around chimney
Oversized chimneySmoky appliance
Flue temperature
not hot enough /
rain water inside
chimney
Smoky appliance
Lighting and
burning problems
Draught is caused by the rising hot air in the chimney when
the appliance is lit.
9
USER INSTRUCTIONS
7. ASH REMOVAL
Warning: Ash can remain hot long after appliance has
been in use.
7.1 Wood:
—Open Doors (see Section 1.14)
—Leave a layer of ash to start the new fire on. Wood burns
best on a bed of ash (approx. 25mm (1") deep).
—Remove ash with a small shovel and place into
a Stovax Ash Caddy (Stovax Part No. 4227) or other
suitable container.
Do not place hot ash in any container made from plastic
or any other combustible material.
—De-ash at least once a week.
7.2 Multi-fuel:
De-ash the appliance before filling with new fuel. Do not
allow ash to build up on the underside of the grate as this
can cause premature failure.
—Insert the Riddling Tool into the socket as shown in
Diagram 8.
8
9
Front plate
Ashpan
PR8881PR8880
—Using gloves, carefully remove ashpan (see Diagram 9).
—Place the ash into a Stovax Ash Caddy (Stovax Part No.
4227) or other suitable container.
—Check and remove ash as often as required when
burning solid fuel.
—De-ash at least once a week.
—Do not place hot ash in a container made from plastic or
any other combustible material.
8. WOOD BURNING TRAY
8.1 In order to burn wood continuously in this appliance a
Wood Burning Tray should be fitted (see Diagram 10).
Push/Pull to
operate
PR8874
—Rotate the Riddling Tool backward and forward
3 or 4 times to remove the ash. Do not force the handle
beyond its natural stop point. The ash will fall into the
ashpan.
—Open doors.
Warning: Ash can remain hot long after appliance has
been in use.
—Remove front plate (see Diagram 9).
10
PR8882
8.2 Remove the multi-fuel grate from the appliance (see
Installation Instructions, Section 4).
8.2 To fit the Wood Burning Tray:
—Remove the log bar and ashlip,
—Hold the tray flat with the front edge pointing forwards
(see Diagram 10).
—Tilt diagonally and insert through the front of the stove
(see Diagram 11).
10
USER INSTRUCTIONS
11
PR8883
—Place flat on the fixings on the bottom of the appliance
(see Diagram 12).
12
9. EXTENDED BURNING
9.1 It is possible to get the appliance to burn for extended
periods. In order to do this:
—De-ash prior to final refuelling.
—Set air controls to low combustion settings. This will
blacken the glass over night but it will clear when
operated at high output for a short period.
—Use smokeless fuel or small, thick logs depending on fuel
desired.
10. OVER-FIRING
10.1 Do not over-fill with fuel or use at maximum output for
long periods or over-firing can occur. If the flue pipe, flue
collar or top plate glow red the appliance is over-firing.
—Close the air controls to reduce the output.
10.2 Over-firing can cause permanent damage to the appliance.
11. CHIMNEY FIRE
PR8884
—Fit the plug supplied in the right hand side where the
riddling mechanism is located (see Diagram 13).
13
Clamp
Bolt
—Replace the log bar.
Plug
PR8454
11.1 If a chimney fire occurs:
—Shut all air controls immediately.
—Evacuate the building.
—Call the fire brigade.
—Do not re-enter the building until it is confirmed safe.
11.2 Do not use the appliance after a chimney fire until:
a) It has been inspected by a registered installer,
confirming the appliance is safe to use*.
b) The chimney system inspected and swept by a chimney
sweep, confirming the system is structurally sound and
free from obstruction before re-use**.
c) It is repaired as required before re-use. Use only
genuine Stovax replacement parts to keep your appliance
in safe and efficient working order.
* Registered on the Competent Persons Scheme (UK only)
see page 14 / INFO (Republic of Ireland).
**This should be done by a HETAS Approved Chimney
Sweep (UK only) see page 14 / INFO registered (Republic
of Ireland only) who will issue you with a certificate.
11
USER INSTRUCTIONS
12. GENERAL CLEANING
12.1 Clean and inspect the appliance regularly, especially in
periods of heavy use. Regular cleaning and maintenance
will help give many years of safe use.
Allow appliance to cool thoroughly to avoid risk of burns.
Clean regularly, according to level of use.
—Remove the ash completely (see User Instructions,
Section 7).
—Check the internal components for damage (grate,
baffle and log guard). Do not use the appliance
if any parts are broken or damaged. Replace damaged
parts with genuine Stovax replacement parts to keep the
appliance in safe, efficient working order.
—Check for obvious build up of soot, ash or debris above
the flue baffle(s) (these can be found in the upper part of
the firebox). Use a torch if necessary.
—If there are any signs of a build up of debris above the
flue baffle(s) either:
—Arrange for the chimney to be swept (see User
Instructions,Section 13).
—Remove the baffle and clear the debris (see Installation
Instructions, Section 4).
13. CLEANING GLASS
13.1 Keep the glass clean with correct use of the Airwash system
and good quality fuel. Sometimes additional cleaning may be
required. This can be done as follows:
—Allow appliance to cool fully. Do not clean hot glass.
—Use a soft cloth and Stovax Glass Cleaner.
13.2 Before re-lighting the appliance:
—Dry the glass fully.
13.3 Do not use abrasive cleaner or cleaning pads.
14. CHIMNEY SWEEPING
14.1 To maintain safe and efficient use of the appliance the
chimney/flue must be inspected and swept at least once a
year by a qualified chimney sweep.*
If the appliance is used continuously throughout the year
or it is used to burn wood or smokeless fuel, more frequent
sweeping is recommended.
The best time to have the chimney swept is at the start of
the heating season.
The above applies even if burning smokeless fuels.
—Clean matt black appliances using Stovax Colloidal black
or Stovax Grate Polish.
—To refresh painted finishes use Stovax Thermolac paint.
—Clean enamel finishes using warm soapy water and a soft
clean cloth.
—Wipe dry with a soft clean cloth be fore relighting.
Always dry appliance to avoid rust.
—Do not use abrasive cleaner or cleaning pads.
—Check that the door shuts properly and creates an
effective seal. Leaking door seals prevent the appliance
working properly.
—Do not use aerosol sprays near an operating
appliance.
In the U.K.
* registered with HETAS (GB only) see page 14 /
INFO (Republic of Ireland only)
** This should be done by a HETAS registered chimney
sweep who will issue you with a certificate.
14.2 The chimney, any connecting flue pipe and the appliance
flue ways if incorporated, must be regularly cleaned.
14.3 Ensure adequate access to cleaning doors where it is not
possible to sweep through the chimney.
14.4 If the appliance is believe to have previously served an
open fire the chimney must be swept a second time within
a month of regular use after installation.
15. CARE OF STOVE
Stovax has a range of cleaning and maintenance products
and accessories to keep your appliance in good working
order. Your Yeoman retailer can advise you on suitable
items for your stove and provide genuine spare parts such
as replacement glass, door sealing rope and rebricks. View
the extensive range at www.stovax.com by clicking on
Accessories. In addition, an annual service by a competent
engineer is recommended to keep your stove in the best
possible condition.
12
Loading...
+ 27 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.