This product is for use only in Great Britain and Ireland (GB, IE)
These instructions are to be left with the customer
carefully and kept in a safe place.
They will be necessary when servicing the appliance.
IMPORTANT
Before installation of this product please read these instructions fully.
The installer should complete the commissioning sheet at the star
, should be read
t of the User Instr
PM173 Issue 2 (August 2006)
uctions.
Contents
elcome to Yeoman
W
ommissioning Data
C
echnical Specification
T
SITE REQUIREMENTS
tove Dimensions
S
earth Dimensions
H
Walls adjacent to Hearths7
PRE-INSTALLATION CHECKS
Flue or Chimney8
Additional Ventilation9
3
4
5
6
7
INSTALLATION INSTRUCTIONS
Installing the Stove10
Commissioning11
OPERATING INSTRUCTIONS
General12
Using the stove for the first time12
Burning Wood12
Burning Solid Fuel13
Ash Removal13
Recommended Fuels14
MAINTENANCE AND SERVICING
General Cleaning15
Cleaning Glass15
Chimney Sweeping15
Annual Service15
2
Welcome toYeoman
Your new Elegance multi-fuel stove is perhaps the most
advanced design of modern stoves. Owning such a stove
shows appreciation for e
Please read your manual thoroughly, its purpose is to
familiarise you with your stove, and give guidelines for its
installation, operation and maintenance. If after reading this
manual you need further information, please do not hesitate
to contact your Yeoman dealer.
xceptional quality.
IMPORTANT NOTICE
If your stove is installed correctly
of excellent service for which it was designed. This appliance
must be installed by a HETAS registered installer (GB only).
, it will give you many years
WARNING
All types of heating appliance can be potentially dangerous.
Correct installation and operating procedures must be
observed when fitting this stove. Some parts of your stove are
protected on their surface with heat proof paint. When the
stove is first used it is normal for it to emit some light smoke,
with an unpleasant smell. Though unpleasant, this is non
toxic and is produced only whilst the stove paint fully cures.
e recommend that you ventilate the room until this
W
disappears.
3
FOR YOUR RECORDS
o assist us in any Guarantee claim please complete the following information:-
Date installed:......................................................................................................................................................................................
Model Description:..............................................................................................................................................................................
Company name:...................................................................................................................................................................................
Briquette smokeless fuel suitable for closed appliances.
(Ancit - Phurnacite - T
Top
Only
Top
Only
aybrite - Homefire Ovals).
Top
Only
Top
Only
Only
Top
5
SITE REQUIREMENTS
efore installation of this product please read these
B
nstructions fully.
i
It is very important to also understand the requirements
f the UK Building Regulations (England and Wales -
o
ocument J / Scotland - Part F), along with any local
D
egulations and working practices that may apply. Should
r
any conflict occur between these instructions and these
regulations then the regulations shall apply.
he Elegance Stove should be fitted by a HETAS (GB
T
nly) registered installer, or approved by your local
o
building control officer. Your Yeoman dealer should be
able to arrange this service for you.
our building insurance company may also require you to
Y
nform them that you have installed a new heating
i
appliance, so check with your insurers that your cover is
still valid after installing the Elegance Stove.
All electrical connections should meet the requirements
of UK Building Regulations (England and Wales Document P / Scotland - Part N).
Your local Building Control Office would be happy to
advise, should questions arise regarding the requirements
of the regulations.
ELEGANCE STOVE DIMENSIONS
Elegance 200
When completing the installation and building works you
should comply with your responsibilities under the Health
and Safety at Work Acts, and any new regulations, which
may be introduced during the lifetime of these
instructions.
A faulty installation could cause danger to the
inhabitants and structure of the building.
Elegance 220
Elegance 210
Elegance 240
6
SITE REQUIREMENTS
Elegance 250
Elegance 280
Elegance 270
7
SITE REQUIREMENTS
dditional information covering the installation of the
A
legance stove may be found in the British Standard:
E
BS8303.
HEARTH DIMENSIONS
The appliance must stand on a constructional hearth
with the minimum dimensions as shown in diagram
elow.
b
WALLS ADJACENT TO HEARTHS
50mm minimum
1
50mm minimum
1
Solid, non combustable
aterial e.g concrete or
m
asonry
m
150mm
minimum
C
A
Yeoman Elegance
C
150mm
minimum
Wall Thickness W
If you are fitting the appliance into an existing hearth
setting, check that it complies with the current
construction regulations and is at least the minimum sizes
shown.
If you have no existing fireplace or chimney, it is possible
to construct a suitable non-combustible housing and
hearth setting. However this should be constructed to
comply with the requirements of both current national
and local regulations with the design approved by your
local building control officer
. Masonry chimney systems
built with clay or concrete liners or pre-fabricated block
systems should be constructed in accordance with B
6461 : Part 1. F
actory made insulated systems should
comply with BS 4543 : Part 2 and be installed to BS 7566
: Parts 1 to 4.
Remember that any new chimney added to your property
may also require planning permission.
225mm
inimum
Constructional
hearth 840mm
inimum
m
m
Location of hearth
or Elegance Stove
Where the hearth
abuts a wall and the
Elegance Stove is
not more than
50mm from the
Change in level to
mark safe perimeter
Solid, non-combustible material
Thickness (W)
200mm
150mm
minimum
At least 300mm
above the
Elegance Stove
and 1200mm
above the hearth
Constructional
earth 840mm
h
minimum
Height (A)
wall
Where the hearth
abuts a wall and the
Elegance Stove is
more than 50mm
75mm
but not more than
300mm from the
S
wall
At least 300mm
above the
Elegance Stove
and 1200mm
above the hearth
Where the hearth
t least 300mm
does not abut a wall
and is no more
75mm
A
above the hearth
than 150mm from
the wall
Note: there is no requirement for protection of
the wall where C is more than 150mm
8
PRE-INSTALLATION CHECKS
t is important that adequate ventilation exists and the
I
lue or chimney system that is to be used is in good
f
working condition. Products of combustion that enter the
room could be a serious health risk. Before installation of
this product we recommend that the flue or chimney
system and ventilation requirements are inspected by a
competent person, and passed as suitable for use with the
appliance to be fitted. In particular the following should
e checked: -
b
Model
.5 The flue exit from the building should be positioned to
1
omply with the requirements of the Building
c
Regulations.
.6 Any existing flue should be confirmed as suitable for the
1
ew intended use, as defined in the Building Regulations.
n
Without liner system
Round (diameter)
Without liner
Flue/Chimney Size
system Square
(minimum dimension).
With liner or factory
made system (diameter).
Installed in accordance with
manufacturer’s instructions
Flue/Chimney
minimum height*
* When measured from the top of the stove to the top of the flue,
with no horizontal sections and a maximum of four bends with an angle of less than 45°
1. Flue or Chimney
1.1 The construction of the flue or chimney system should
meet the requirements of the Building Regulations with
sizes as shown: -
1.2 An approved, factory made system suitable for solid fuel
use, complying with B
installed to the requirements of BS 7566: Parts 1 to 4, the
manufacturer’s instructions and the requirements of
Building Regulations.
1.3 New masonry chimney systems built with clay or concrete
liners or pre-fabricated block systems should be
constructed in accordance with BS 6461 : Part 1, and the
requirements of Building Regulations, may be used.
1.4 A flexible flue liner system may be used, if it is
independently certified for use with solid fuel systems,
and is installed according to the manufacturer’s
instructions and the requirements of Building
Regulations. If an appliance is being replaced on an
xisting flexible flue liner system, the liner system should
e
be replaced, unless it can be proved to be recently
installed and can be seen to be in good condition.
S 4543: P
art 2, may be used when
Elegance 200
mm
inch
mm
inch
mm
inch
m
feet
150150150150150150150
6666666
135135135135135135135
5.55.55.55.55.55.55.5
150150150150150150150
6666666
4444444
13131313131313
1.7 Any existing flue or chimney system must be inspected
and swept by a NACS registered (GB only) chimney
sweep, to confirm that the system is structurally sound
and free from any obstructions.
1.8 Suitable access should be provided to enable the
collection and removal of debris.
1.9 Provision should be made to sweep and inspect the flue
when the appliance is installed.
1.10 No other heating appliances should be connected to, or
share, the same flue or chimney system.
1.11 Check the flue draught. This should be done with all
windows and doors closed and any e
or adjoining rooms running at maximum speed (see ne
section for additional ventilation requirements).
Note: A guide containing general information on
chimneys and flues is obtainable from: -
The British Flue & Chimney Manufacturers’
Association, FETA
2 W
Hare Hatch, Reading
Bucks RG10 9TH
Elegance 210
altham Court, Milley Lane
Elegance 220
Elegance 240
Elegance 250
xtraction fans in this
Elegance 270
Elegance 280
xt
Tel : - 01189 403416 e-mail :- info@feta.co.uk
9
PRE-INSTALLATION CHECKS
.12 Where a hearth, fireplace, flue or chimney is provided or
1
xtended (including cases where a flue is provided as part
e
of refurbishment work), information essential to the
correct appliance and use of these should be permanently
posted in the building, to meet Requirement J4 of the
Building Regulations (England and Wales), F3.12
(Scotland).
2. ADDITIONAL VENTILATION
2.1 Additional ventilation will be required to comply with
the requirements of the Building Regulations. This
should be provided using a permanently open air vent, of
the size listed, which is positioned so that it is not liable
to be blocked both inside and outside the building.
Model
Additional Ventilation
2.2 Extractor fans or cooker hoods should not be placed in
the same room or space as the appliance.
2.3 If any of these checks reveal problems, do not proceed
with the fitting of the appliance until they have been
rectified.
mm
cm
sq. inch
Elegance 200
Elegance 210
Elegance 220
Elegance 240
Elegance 250
Elegance 270
nonenone1100none5505501650
--11-5.55.516.5
--4.33-2.172.176.50
Elegance 280
10
INSTALLATION INSTRUCTIONS
ecause each installation is unique to the property, it is
B
ot possible to give full details to suit every setting.
n
However the installation should comply with the
requirements of the Building Regulations and be made
using ‘best practice’ construction methods.
emember that many fireplace openings will have a
R
supporting lintel. Do not remove this without making
provision to support the remaining structure of the
building. The Elegance stove must not form any part of
the supporting structure.
1. INSTALLING THE STOVE
1.1 Remove all packing and temporary transportation fixings
from the Elegance stove, check that no parts have been
left in the ashpan.
1.2 Lift the stove into position on the prepared hearth area,
taking care not to damage the hearth finish.
Connect the stove to the chimney system, using Stovax
1.3
enamelled flue pipe and seal the connecting joints.
Typical top and rear flue connections are shown.
.6 Typical top flue installation. Flue to be installed in
1
ccordance with manufacture’s instructions.
a
o chimney connection as
T
etailed in building regulations
d
35° Elbow
1
izeStovax Part No
S
”4512
5
”4612
6
600mm
inimum
m
1000mm
maximum
n-supported
u
lue Pipe 915mm (3ft)
F
izeStovax Part No
S
”4502
5
”4602
6
1.7 As it is not possible to fully sweep the flue through the
stove, provision must be made to clean the flue and
collect debris without removing the stove.
1.4 Top flue pipe installation
Flue Pipe 915mm (3ft)
SizeStovax Part No
5”4502
6”4602
Seal Collar with Fire Cement
Connect a flue pipe by inserting it into the flue spigot
1.5
and sealing using fire cement.
11
INSTALLATION INSTRUCTIONS
2. COMMISSIONING
2.1Before lighting the Elegance stove, check the following
items: -
a) Fit of internal parts (firegrate, firebricks, baffles, and
fuel retainer).
) Door alignment, seals and catch operation.
b
) Operation of air controls.
c
2.2If there are any problems with the fit or operation of any
of these items, this should be corrected before
continuing with the commissioning of the Elegance
tove.
s
2.3Carry out a final smoke draw test, by first warming the
lue with a blowlamp, or similar, for about 10 minutes.
f
Then place a smoke pellet on the centre of the grate,
with the air controls open, and close the door. Smoke
should now be drawn up the flue and be seen to exit
from the flue terminal. This test should be completed
with all doors and windows in the room where the stove
is fitted closed. Should this test fail, the suitability of the
flue system and ventilation should be re-checked.
2.4Light the appliance and gently allow the temperature to
increase slowly to operating levels. Check that no
combustion products are entering the room. When the
stove has reached a steady operating condition open the
main firedoor and carry out a spillage test with a smoke
match or pellet around the door opening.
2.5If excessive spillage does occur, allow the appliance to
cool and re-check the suitability of the flue system and
ventilation.
2.6Explain the safe operation of the stove and the use of
the controls to the user, along with the need to only use
suitable fuels. Also explain the cleaning and routine
maintenance requirements.
2.7Explain the requirements to use a suitable fireguard
when children, elderly or infirm persons may be near the
appliance.
2.8 Record dealer/supplier details and installer details in
user instructions.
2.9 Record serial number in user instructions.
number will be required when ordering spare parts and
making warranty claims.
This
2.10 Give the copy of the user instructions to the
customer
.
12
OPERATING INSTRUCTIONS
1. GENERAL
1.1 This stove is designed for domestic heating and should
only be used for this purpose, and in accordance with the
manufacturer’s operating instructions.
1.2 It should be installed by a competent installer (HETAS
registered GB only), in accordance with all local
regulations, including those referring to national and
European standards.
1.3 The stove should only be used to burn approved fuels
and should not be used with liquid fuels or used as an
incinerator.
1.4 As with all heating stoves, the surfaces will become very
hot when in use, therefore due care should be taken
when near the stove. If it is to be used in the presence of
young children, elderly or infirm persons a suitable
fireguard should be used. Care should also be taken with
the placement of combustible items near the stove as
conducted and radiated heat could cause a fire hazard.
Stovax offer a wide range of firescreens and sparkguards,
along with a hearthgate system designed to offer full
protection for a range of stoves and fireplaces. Your
Stovax dealer can advise you on these products.
1.5 The additional ventilation required for the safe use of this
stove should be kept free of any obstructions, both inside
and outside the building, at all times.
2. USING THE STOVE FOR THE FIRST
TIME
2.1 When new, it is best to burn the fire at a low output for
the first few days of use. This will allow the construction
to settle and all fixing glues and paint to fully cure.
2.2 Avoid touching the paint during the first period of use.
.3 During this time the stove may give off some unpleasant
2
dours, and we recommend that you keep the room well
o
ventilated during this period to avoid a build-up of fumes.
3. BURNING WOOD
3.1 Open the Airwash control fully and open the Primary
air control
3.2 Place some pieces of firelighter or dry crumpled paper on
the grate and cover with some small pieces of dry
kindling wood. Light the paper or firelighters.
3.3 To avoid the build-up of condensation on the door glass
it is advisable to leave the door slightly open as the fire
establishes and the glass warms.
3.4 As the fire becomes established add larger pieces of wood
and fully close the door.
door open as this could over-fire the stove and cause
permanent damage.
to approximately 25% open.
Do not leave the stove with the
1.6 Have your Stovax product serviced annually by a
competent service engineer, and if repairs are required
use only Stovax approved spare parts.
1.7 Do not make unauthorised modifications or changes to
the stove.
1.8 SERIAL NUMBER This number will be required when
ordering spare parts or making warranty claims.
1.9 AIR CONTROLS (typical layout)
AIRWASH
CONTROL
Above door
PRIMARY AIR
CONTROL
On door
See instructions for
detailed use of
controls
3.5 As the fire becomes established, close the Primary air
and control the burn rate using the Airwash
control
only.
control
3.6 To burn wood efficiently it is best to allow a bed of ash to
build-up on the grate, or the base of the stove, and
control the combustion using the
3.7 Before re-fuelling the stove it is advisable to first rake the
embers evenly over the firebed then open the
fully for a few minutes, to establish a glowing bed
control
before adding new logs.
3.8 Allow the new logs to burn at high output for a few
minutes before adjusting the burn rate, with the
, to the desired setting. It is best to refuel little
control
and often to maintain clean and efficient burning
3.9 The ideal control settings to suit the particular
installation and personal preferences will be established
by experience in using the stove.
3.10 It is not recommended to load large amounts of logs and
burn with the Airwash control on low settings for long
periods of time as this will reduce the effectiveness of the
glass cleaning effect of the airwash. Also this will cause
large a build-up of tars and creosotes in the stove and
flue system.
Airwash control only.
Airwash
Airwash
.
13
OPERATING INSTRUCTIONS
.11 We would recommend that the stove be burnt at high
3
utput for at least 30 minutes each day when it is in use.
o
This will help reduce the build-up of tars and creosotes
within the stove and flue system.
.14 Do not burn painted or impregnated wood,
3
anufactured board products, pallet wood or scrap
m
timber.
4. BURNING SOLID FUEL
4.1 Open the Airwash control to approximately 50% and
Primary air control fully.
4.2 Place some pieces of firelighter or dry crumpled paper on
the grate and cover with some small pieces of dry
kindling wood. Light the paper or firelighters.
4.3 To avoid the build-up of condensation on the door glass
it is advisable to leave the door slightly open as the fire
establishes and the glass warms.
4.4 As the fire becomes established add pieces of solid fuel
and fully close the door.
door open as this could over-fire the stove and cause
permanent damage.
4.5 As the fire becomes established, reduce the Airwash air
to approximately 25% and control the burn rate
control
using the
4.6 To burn solid fuel efficiently it is best to control the
combustion using the
4.7 Before re-fuelling the stove it is advisable to first de-ash
the firebed, using the riddling grate system (if fitted) or a
suitable poker.
riddling system or if using a poker to clear the firebed.
4.8 Then open the Primary air control fully for a few
minutes, to establish a glowing bed before adding new
fuel. Allow the new fuel to burn at high output for a few
minutes before adjusting the burn rate with the
air control
and often to maintain clean and efficient burning.
4.9 The ideal control settings to suit the particular
installation and personal preferences will be established
by experience in using the stove.
4.10 We would recommend that the stove be burnt at high
output for at least 30 minutes each day when it is in use.
This will help reduce the build-up of tars and creosotes
within the stove and flue system.
4.11 Do not burn bituminous coal, ‘petro
petroleum based fuels, as this will invalidate the
product guarantee.
Primary air control only.
Do not use bare hands to operate the
to the desired setting. It is best to refuel little
Do not leave the stove with the
Primary air control only.
Primary
e’ or other
cok
-
VER-FIRING
O
4.12 Do not use the appliance at maximum output for
prolonged periods of time, or over fill the firebox with
uel, as this could result in over-firing. If the connecting
f
luepipe, appliance flue collar or top plate glow red with
f
eat the appliance is being over-fired and the air controls
h
should be closed to reduce the output.
4.13 If a chimney fire occurs shut all air controls immediately
to close the appliance down, and evacuate all persons
from the building before calling the fire brigade. Do not
re-enter the building until it is confirmed safe to do so.
4.14 Following a chimney fire do not use the appliance until it
is inspected, by a HETAS (GB only) registered installer,
to confirm that the appliance is safe to use, or make any
repairs required before re-use. Only genuine Stovax
replacement parts are to be used to keep your appliance
in safe and efficient working order
4.15 After any chimney fire it is recommended that the
chimney system be inspected and swept by a NACS
registered (UK only) chimney sweep, to confirm that the
system is structurally sound and free from any
obstructions before re-use.
SEASONAL USE
4.16 If the stove is not to be used during the warmer periods
of the year it is recommended to clean and service the
stove, as detailed in the maintenance and servicing
section of this booklet.
4.17 The air controls should be set in the 50% open position
to keep the appliance ventilated, and stop the build-up of
any moisture inside.
4.18 Before re-lighting the stove remove the baffles, clear any
debris that may have accumulated, and check the flue is
clear of any block
ages.
.
5. ASH REMOVAL
5.1 The burning of any fuel will produce ash, which will have
to be removed after a period of use. This time will depend
on the fuel used. Before removing the ash from the stove
it is advisable to let the fire burn down to a low level, or
even go out completely
from the stove after opening the door
As heat can remain in the ash for a long period after use
5.2
care must be tak
ashpan. We suggest that the ashpan be carried using
gloved hands, or the ash is placed directly into a Stovax
Ash Caddie.
. The ashpan can be removed
.
en when removing and carrying the full
14
OPERATING INSTRUCTIONS
.3 When burning wood the amount of ash will be smaller
5
nd may only need removal once every week. To do this,
a
allow the fire to burn out and cool. Then after removing
the log retainer scoop out the ash with a suitable shovel.
It is best to leave a layer of ash in the stove to form a bed
for the new fire.
5.4 Do not place ash in a bin made from plastic or any other
combustible material.
6. RECOMMENDED FUELS
6.1 Wood: - Burn only seasoned timber, with a moisture
content of less than 20%. In most cases, this would
require drying cut wood for at least 12 to 18 months
before use. Poor quality timber could cause low
combustion efficiency and produce large amounts of
harmful condensation, which could reduce the
effectiveness of the airwash system, and ultimately the life
of the stove.
6.2 Do not burn painted or impregnated wood or
manufactured board products.
The symptoms of poor performance related to wet wood
include: -
•difficulty getting a fire going and keeping it burning well
•smoky fires with little flame
•dirty glass
•rapid creosote build-up in the chimney
•low heat output
•short burn times, excessive fuel consumption and
blue/grey smoke from the chimney.
6.3 To help avoid large build-ups of tars and creosote within
in the stove and the flue system, it is recommended to
burn at maximum output for at least 30 minutes each
day
. The use of Stovax Protector chimney cleaner will
also help to reduce this problem.
Solid fuel: - Burn manufactured smok
6.4
suitable for use with closed heating stoves. Do not burn
e’ or other petroleum based
bituminous coal, ‘petrofuels, as this will invalidate the product guarantee.
cok
eless fuels, listed as
6.5 If you require advice on suitable solid fuels contact your
local Approved Coal Merchant. Details can be obtained
by ringing the Solid fuel Association advice line on
Freephone 0800 600 000, or their web site at
.solidfuel.co.uk
www
15
1. GENERAL CLEANING
MAINTENANCE AND SERVICING
.6 Re-fit cleaned internal parts.
4
1.1 We would recommend that your Elegance stove be
cleaned fully on a regular basis, according to the level of
use. Attention should be given to cleaning the baffle
system, flueways and removing ash. Regular cleaning and
preventive maintenance will help give many years of safe
use.
1.2 The external paintwork may be cleaned using warm
soapy water and a soft clean cloth. Wipe dry with a soft
lean cloth before re-lighting. Do not leave unit without
c
rying, as this may cause rust.
d
2. CLEANING GLASS
2.1 While the correct use of the Airwash system, and good
quality fuel, will generally keep the glass clean when the
appliance is used you may sometimes need to clean the
glass.
2.2 This can be done as follows. Allow the Elegance stove to
cool fully, never attempt to clean hot glass. Any deposits
can then be removed using a soft cloth and Stovax Glass
Cleaner.
4.7 Remove the glass from the door, and discard all old rope
seals.
4.8 Remove the door rope seal from the outer edge of the
door clean the old glue from the door sealing rope grove.
4.9 Clean the door glass using Stovax Stove Glass cleaner
and a soft cloth. Do not use abrasive cleaners to remove
ar or soot deposits from the glass.
t
4.10 Replace the glass edge seal with new and re-fit the glass
into place in the door.
4.11 Fit new door rope seal, gluing it in place with Stovax
Thermic Seal rope adhesive. When fitting new door seals
we recommend closing the stove door and leaving for at
least 12 hours before using. This allows the adhesive to
fully bond to the seal before use.
4.12 Lightly oil the door catch mechanism and hinge pins.
Avoid getting oil on to the door seals, glass and
paintwork.
4.13 To refresh painted finishes it is possible to re-paint using
Stovax Thermolac stove paint.
2.3 Before re-lighting the appliance, dry the glass fully.
2.4 Do not use abrasive cleaner or cleaning pads.
3. CHIMNEY SWEEPING
3.1 We would recommend that to maintain the safe and
efficient use of the appliance the flue / chimney is
inspected and swept at least once a year, by a NACS
registered (UK only) chimney sweep, to confirm that the
system is clean, structurally sound and free from any
obstructions.
4. ANNUAL SERVICE
4.1 At the end of the heating season it is recommended to
strip, inspect and clean the stove as detailed: -
4.2 Carefully remove all of the following internal parts.
Internal Baffle, Firebricks, Complete grate, Ashpan, and
acuum clean any remaining ash and debris from the
V
inside of the stove.
4.14 We recommend that only genuine Stovax replacement
parts are use to keep your appliance in safe and efficient
working order. Your local Stovax dealer will be able to
provide you with the genuine parts you require.
4.15 When using the stove for the first time again it is best to
burn the fire at a low output for the first day of use. This
will allow the new seals to settle and all new fixing glues
and paint to fully cure.
4.16 During this time, the stove may give off some unpleasant
odours, and we recommend that you keep the room well
ventilated during this period to avoid a build-up of fumes.
4.17 If you require help, your local Y
to carryout all of your service and maintenance
requirements for a reasonable cost.
eoman dealer will be able
4.3 Clean the internal, metal, surfaces of the stove a using a
wire brush and scraper as required and vacuum and brush
the resulting debris from the stove.
4.4 Clean the Grate parts with a wire brush, check for any
damage and replace any damaged parts as required.
4.5 Check and clean, with a soft brush the Firebricks.
Replace any broken bricks. It is normal for some surface