YCL MF600SWE Datasheet

Product Specification
MF600SWE
Data sheet subject to change without notice RDPS-MF054(R0)09/23/2002
SHEET 1 OF 11
File No RDPS-MF054 Revision R0 System Application Asymmetric Digital Subscriber Line Product Type POTS Splitter Product Name MF600SWE Date Sep. 23th, 2002
Jay Hsieh - Design Engineer, R&D_1Issued By
jay@ycl.com.tw
Roger Wu – Manager, R&D_1Approved By
Roger@ycl.com.tw
Issued Date
YCL Electronics Co., Ltd.
No.95, Feng Jen Road. Feng Shan City, Kaohsiung, Taiwan, R.O.C.
This controlled document is the property of YCL Electronics Co., Ltd. Any duplication reproduction or transmission by unauthorized parties without the prior written permission of YCL Electronics Co., Ltd. is prohibited.
Product Specification
MF600SWE
Data sheet subject to change without notice RDPS-MF054(R0)09/23/2002
SHEET 2 OF 11
Table of contents
Item Description Page
1 Introduction
-----------------------------------------------
3
2 Reference
-----------------------------------------------
3
3 Abbreviations
-----------------------------------------------
4
4
Technical requirements
-----------------------------------------------
5
4.1. Schematic
-----------------------------------------------
5
4.2. ZHP-r definition
-----------------------------------------------
5
4.3. Electrical specification
-----------------------------------------------
6
4.4. DC characteristic
-----------------------------------------------
8
4.5. Test methodology
-----------------------------------------------
8
4.5.1. Insertion loss
-----------------------------------------------
8
4.5.2. Return loss
-----------------------------------------------
9
5 Environmental condition
-----------------------------------------------
10
5.1. Resistibility to overvoltage and overcurrents
-----------------------------------------------
10
5.2. Climatic condition
-----------------------------------------------
10
5.2.1. Operating temperature
-----------------------------------------------
10
5.2.2. Storage and transport
-----------------------------------------------
10
5.2.3. Operating humidity
6 Reliabilty conditions
-----------------------------------------------
10
6.1.Thermal shock
-----------------------------------------------
10
6.2. Temperature humidity exposure
-----------------------------------------------
10
6.3. Vibration test
-----------------------------------------------
10
7 Mechanical condition
-----------------------------------------------
11
7.1. Mechanical
-----------------------------------------------
11
Product Specification
MF600SWE
Data sheet subject to change without notice RDPS-MF054(R0)09/23/2002
SHEET 3 OF 11
1. Introduction:
The MF600SWE is a splitter module that has been specifically designed to implement the functionality of low pass filter in POTS over ADSL application.
Asymmetric Digital Subscriber Line (ADSL) technology is dedicated , point to point , public network access technology that allow multiple forms of data , voice , and video to be carried over twisted-pair copper wire on the local loop between a network service provider’s(NSP’S) central office and the customer site or on local loops created either intra-building or intra­campus. Best of all , ADSL delivers this high speed performance over existing copper telephone line all while allowing traditional voice service to coexist without interruption through POTS low pass filters. The POTS-splitter on the customer premises side consists of a lowpass section( installed in aseparated plastic box ).
The MF600SWE integrate low pass filter that block the high frequency energy from reaching the POTS device and provide isolation from impedance effects of the POTS device on ADSL.In addition , these filter will also attenuate any wideband impulse noise generated by the POTS device due to the interruption of loop current(e.g. pulse dialing or on hook / off hook transfer) Because the POTS splitter connects directly to the subscriber loop media , it must also provide some protection for externally induced line hits or faults which could damage any attached equipment or endanger humans interacting with the installed equipment. The circuit protection will be provided mostly by standard central office line protection means and additional protection measures built into POTS splitter to protect against line overstress which could damage the splitter itself. The electrical and transmission specification is based on ETSI TR 101 728 and castomer requird .
2. Reference:
Ref. 1 : ETS 300 019 Environmental conditions and environmental tests for Telecommunications equipment Ref. 2 : ETSI 101 728 Network and Customer Installation
Ref. 3 : ITU-T K20 Resistibility of telecommunication switching Equipment to overvoltages and overcurrents Ref. 4 : ITU-T K21 Resistibility of subscribers terminal to overvoltage and
overcurrents
Product Specification
MF600SWE
Data sheet subject to change without notice RDPS-MF054(R0)09/23/2002
SHEET 4 OF 11
3. Abbreviations:
ADSL Asymmetric Digital Subscriber Line CO Central Office CPE Customer Premise Equipment. POTS Plain Old Telephone Service RT Remote Terminal ADSL-NT Network termination of ADSL
Loading...
+ 7 hidden pages