YCL DDE-007 Datasheet

Date: Sep 19,2003
49
20Watts 3.3V&5.0V Dual Output Power Supply
Model No.: DDE-007
Feature:
l UL safety meet. l EMI/RFI meet VDE & FCC limit B. l 20 Watts in 102×51.8×30mm size. l 2 Year Warranty.
Specifications: typical at nominal line, full load at 25°C.
Input Specifications: General Specifications:(at -48Vdc Input)
Input voltage: -38 to -72Vdc Efficiency: 70% typical at full load Input current: 0.57 A at -48Vdc EMI/RFI: VDE & FCC Class B limits
Output Voltage Accuracy: +3.3V: ± 2%
+5.0V: ± 2%
Dielectric Withstand:
Input/output: 1500Vdc
Output Specifications:(at -48Vdc Input)
Output Rating: Vo1:+ 5V /0.5A
Vo2:+3.3V /5A
Safety Meet: UL UL60950
Line Regulation: ± 2%
Switching frequency: 47kHz
Load Regulation (at full load to 1/2 load):
± 3%
Weight: 150g
Temperature Coefficient: ± 0.05% / °C
Environmental Specifications:
Ripple & Noise: 50mVp-p max
Operating temperature: 0 to +50 °C Storage temperature: -40 to +85°C Humidity: 5 to 95 % RH non-condensing
Vibration: 2.4G 5 TO 500 HZ
Protections: a. Over voltage protection
b. Over power protection c. Short circuit protection
Cooling: Free air convection
Note:
1. Vibration test: Three orthogonal axes, random vibration, 10 minutes for each axis.
2. Maximum output power is 20W.
3. At least 20% of load is required to obtain stable regulation.
4. Ripple & noise test method is measured at output terminal across a 0.1uF ceramic cap
& a 10uF tantalum cap in parallel with a 20MHz bandwidth oscilloscope direc tly.
¬ Please refer the safety approval status on appendix 1, For latest safety approval status
Please consult YCL or visit" www.ycl.com.tw "
Date: Sep 19,2003
50
20Watts 3.3V & 5V Dual output Power Supply
Model No.: DDE-007
Dimensions: mm ± 0.5mm
l AC input mating connector is 5096-02C or Ever 8763-03N2 or equivalent. l DC output mating connector is Molex 67280-0500,Ever 2532-05K or STM M241855 or
equivalent.
CON1
COM
-
Loading...