Yates Protect Y- 530 User Manual

Y- 530
PORTABLE THERMAL DETECTOR
Yates Protect Y-530 User Manual
2
Y- 530
PORTABLE THERMAL DETECTOR
Table of Contents
Product Introduction .................................................................................................................... 3
Product Highlights ....................................................................................................................... 4
Product Features ........................................................................................................................ 5
Product Familiarization ................................................................................................................ 6
Basic Operation .......................................................................................................................... 7
Startup..................................................................................................................................... 7
Shutdown ................................................................................................................................ 7
View version number .............................................................................................................. 7
Check the device ID ................................................................................................................ 7
How to change the temperature settings .................................................................................... 9
Enter the device password ...................................................................................................... 8
Change the temperature settings after entering the password ................................................. 9
How to change the device language ........................................................................................... 9
How to change the voice volume .............................................................................................. 10
How to set an ID number ........................................................................................................ 111
How to restore the factory settings ............................................................................................ 11
Installation note ................................................................................................ ......................... 12
Temperature Detection Operational Notes ................................................................................ 12
Technical Specifications ............................................................................................................ 13
Disclaimer ................................................................................................................................. 14
Technical Support……………………………………………………………………………………….14
3
Y- 530
PORTABLE THERMAL DETECTOR
Product Introduction
This unique thermal-detector can detect human body surface temperature from a safe distance and without physical contact. This method helps prevent the spread . of infectious diseases. This system uses the highest quality and most precise temperature sensor on the market today.
In addition to a green light signifying in-range temperatures and a red light indicating out-of­range body temperatures, this system also uses voice warningsThese voice warnings can be customized to your desired language.
This high-quality temperature sensor integrates into walk-thorough metal detectors, ordinary doors, intelligent access control systems, disinfection equipment, and other equipment that uses temperature measurement functions.
4
Y- 530
PORTABLE THERMAL DETECTOR
Product Highlights
Human Body Temperature Screening
Dynamically monitor and screen human body temperature
Infrared monitor takes precise temperature measurements
Built-in high-precision miniature monitor
High-quality Components
Highly accurate and reliable with stable performance.
Modular Component Design
Modular design allows the unit to be used as a stand-alone or integrated into other equipment and instruments
Durable, solid-metal case helps prevent damage to the unit
Easy to Use
Modular design allows the unit to be used as a stand-alone or integrated into other equipment and instruments
5
Y- 530
PORTABLE THERMAL DETECTOR
Product Features
Quick Screening
Easily and actively collect infrared temperature data
Human operator NOT required for temperature measurement
Temperature measurement completed in less than one second
Non-contact Temperature Measurement:
The infrared temperature sensor allows no contact temperature reading
No contact temperature reading helps to eliminate cross-contamination between people
Temperature read from the wrist or forehead
Voice Alarm
Voice alarm quickly states, “Your temperature is normal” or “Please check again”
Customize the voice alarm to speak different languages
Visual Notification
Green light for normal temperature
Red light for temperatures out-of-range
Application Environment
Operates normally in temperatures of 14°-104°F [-10°-40°C].
Panel Display
Easy-to-read, clear and bright digital display
Works in a wide range of ambient lighting conditions
Prevents False Alarms Due
Intelligent programming helps prevent false alarms due to high ambient temperatures or direct sunlight
6
Y- 530
PORTABLE THERMAL DETECTOR
Product Familiarization
Temperature Display
Easy-to-read, clear and bright digital display shows the temperature value in real time
Visual Notification
Green light for a normal temperature range of 95°F – 98.6°F (35°C-37°C)
Red light for temperatures outside of the normal range of 95°F – 98.6°F (35°C-37°C)
Distance Sensor
The infrared temperature sensor starts to work when a person or object gets to within approximately 7.9 inches (20cm)
Infrared Sensor
Detects body temperature in real time when a forehead or wrist comes into range of the infrared sensor
Voice Alarm
Voice alarm quickly states, “Your temperature is normal” when the sensor determines a normal temperature range of 95°F – 98.6°F (35°C-37°C)
Voice alarm quickly states, “Please check again” when the sensor determines the temperature is outside the normal range of 95°F – 98.6°F (35°C-37°C)
7
Y- 530
PORTABLE THERMAL DETECTOR
Basic Operation
Startup
Connect power
Press the POWER button to start the system; the device will display 0
Shutdown
Press the POWER button to power off the system
To view the version number of the program
Press the SELECT button twice. The device displays the program version number
Press the SELECT button again to return to the main screen
To check the device ID
Press the ADJUST button twice and the device will display the program version number
Press the ADJUST button again to return to the main screen
8
Y- 530
PORTABLE THERMAL DETECTOR
How to Change the Temperature Settings
These instructions show how to change the ambient and alarm temperature settings if necessary.
NOTE: All temperature settings are displayed in Celsius by default. The factory settings should work under most conditions and should not need to be changed.
Factory Settings
Alarm temperature: 98.6°F (37°C). [3700 in the display denotes that the alarm temperature is 37°C]
Ambient temperature: 77°F (25°C). [2500 in the display denotes that the alarm temperature is 25°C]
o For every 10 degrees the ambient temperature setting is lowered, the body
temperature setting drops 1°C
o For every 10 degrees the ambient temperature setting is raised, the body
temperature setting raises 0.5°C
To enter the device password
1. Press the ENTER button
2. Press the SELECT button to shift
3. Press the ADJUSTABLE button to adjust the number until it reads 1318
9
Y- 530
PORTABLE THERMAL DETECTOR
To change the temperature settings after entering the password
1. Press the ENTER button
2. Press the SELECT button to shift to the alarm or ambient temperature setting
3. After adjusting the setting, press the ENTER button to return to the main screen
How to change the device language
1. Press the ENTER button
2. Press the SELECT button to shift
3. Press the ADJUSTABLE button to adjust the number a. For English, input the number 1317 b. For Chinese, input the number 1316
4. The display shows the number 1111
BODY TEMPERATURE
BODY TEMPERATURE
NORMAL
ALARM
NORMAL
ALARM
NORMAL
ALARM
NORMAL
ALARM
INFRARED DETECTOR
INFRARED
SENSOR
INFRARED DETECTOR
INFRARED
SENSOR
INFRARED
DETECTOR
INFRARED
SENSOR
INFRARED
DETECTOR
INFRARED
SENSOR
1 2 3 4
C C C C
1 3 1 7
1 1 1 1
10
Y- 530
PORTABLE THERMAL DETECTOR
How to change the voice volume
1. Press the ENTER button
2. Press the SELECT button to shift
3. Press the ADJUSTABLE button to adjust the number
4. Input the number 1111
5. Press the ENTER button. The display shows 0000
Press the CONFIRMATION key and the display will show FFFF.
6. Press the ADJUSTMENT key to enter the volume setting screen
7. Press the ADJUSTABLE button to adjust the number a. Mute = 0 b. Normal = 1 c. Maximum = 3
8. Press the SELECT button to toggle between the temperature and the reserved function
11
Y- 530
PORTABLE THERMAL DETECTOR
a. Reserved
function =
1.0
How to set an ID number NOTE: Setting the ID number is only needed when adding the optional LAN network function.
1. Press the ENTER button
2. Press the SELECT button to shift
3. Press the ADJUSTABLE button to adjust the number
4. Input the number 1312
5. Press the ENTER button and the display will show 0000 a. Now you can modify the ID number
6. Press the ENTER button twice to save and return to the main screen
How to restore the factory settings NOTE: The following settings are not included in the factory reset: Temperature type AND
Voice language and volume
1. Press the ENTER button
2. Press the SELECT button to shift
3. Press the ADJUSTABLE button to adjust the number
4. Input the number 1264
12
Y- 530
PORTABLE THERMAL DETECTOR
5. Press the ENTER
button. The display shows FFFF to indicate factory settings have been restored
6. Press the ENTER button to return to the main screen
Installation Note
For best results, we recommend installing this equipment in an indoor area free from wind. A cold wind from outside might influence the temperature readings. We also recommend that the temperature measurement area is protected from bright sunlight to avoid false high results.
Temperature Detection Operational Notes
1. Normal ambient temperature is 32°F - 86°F [0°C - 30°C]. When using it at 14°F [-10°C],
you may have to increase the environmental temperature compensation value
a. Increase the value 5°C at a time, until the scanned result difference between it
and the forehead thermometer is within plus or minus 0.3°C
b. You can also use this method to calibrate the sensor if the scanned results of
many persons are low
2. Measurement method: Measure the forehead or the wrist surface
3. The standard measurement distance is 0.4-4.0 IN [1cm-10cm]
4. The measurement time is 0.5 seconds. After the measurement, advise people to leave
quickly. Otherwise the measurement may be repeated
13
Y- 530
PORTABLE THERMAL DETECTOR
Technical Specifications
Product weight: 1.3 lbs. [0.6kg] Power consumption: <8W Working temperature: 14°~ 104° F [-10°~40°C] Operating humidity: 95% [non-condensing environment] External power supply: AC 100-240V, 50 / 60Hz Working voltage: 12V Temperature measurement speed: <1 second Temperature measurement accuracy: ± 0.3 Temperature measurement distance: 0.4–7.9 in [1-20cm] Product size: 6.5 X 4.4 X 1.3in [164 X 113 X 33mm] (excluding bracket and power
adapter)
14
Y- 530
PORTABLE THERMAL DETECTOR
Disclaimer
The infrared temperature measuring device is the human body surface temperature screening instrument. The test results indicate the real-time temperature evaluation of objects or people in a specific environment. The selling company and the manufacturer shall not bear any responsibility for the direct or indirect loss caused by the use of these test results.
Technical Support
If you experience any issues, please send your email address and issue details to our technical support team at:
Email: support@yatesprotect.com
15
Y- 530
PORTABLE THERMAL DETECTOR
We welcome your comments and suggestions on how to improve our products.
Loading...